Attachment_4_-_Range_Drawings.pdf

PDF 959 KB Posted

Attached to
Range Retrieval System Installation & Training Federal contract opportunity
Solicitation number
FA4659-16-Q-0027
Issued by
Department of the Air Force Air Mobility Command

About this file

Attachment 4 - Range Drawings

View the file

Other files for this federal contract opportunity

Other files attached to Range Retrieval System Installation & Training, newest first.
File Type Posted
Combo_amendment_0003.pdf PDF
Combo_amendment_0002.pdf PDF
Questions_and_Answers_2.docx DOCX document
Combo_amendment_0001.pdf PDF
Attachment_5_-_steel_plate.PNG PNG image
Attachment_3_-_Questions_and_Answers.pdf PDF
Attachment_6_-_List_of_Site_Visit_Attendees.pdf PDF
Combo.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A-1.7 A-3.5

AA

R-6

A-201 D1

A-201 C1

A-201 B1

A-201 A1

A4 A-301

C1 A-301

FIRING

PLATFORM

ELECTRICAL

STORAGE

DOWNRANGE

7A

107D

A4 A-301

1 2 3 4 5 6 7 8 9 10 11

A-3

B

A

107C

01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21

3'-4" 3'-4"

118'-0"

2'- 8"

8'- 0"

9'-

0"

RA

RB

A-2

RC

RD

RE

RF

RG

RH

7'- 0"

7'- 0"

1'- 8" 53'-11" 1'-3"

1'- 8"3'-9" 42'-9"

A5 A-301

R-1 9'-

4" 7"

3'-0"

3'-4" 5'-8"

AF1AF1

AF1AF1

AF1AF1

AF1AF1

AF1AF1

AF2 AF2

AF2AF2

AF2AF2

AF2AF2

AF3 AF3

TYP (9 THUS) TYP (9 THUS) AF4AF4

AF5AF5 AF5AF5

AF10 AF10

AF10 AF10

AF14AF14AF14

AF7

AF7AF7

AF8 TYP

AF8TYP

AF9

AF15

AF9

AF15

AF15

AF15

AF15

AF15

AF15

AF11AF11

25'-1" 65'-0" 25'-1"

'-0

'-0

7'- 7 1

/2" 2'-

8'- 0"

2'-

'-2

2'-

'-1 1"

2'-

7'-

0 1 /2"

'-6

M8 M8 M12G M8M8M12G

RANGE MASTER'S

CONTROL PLATFORM

7M TARGET LINE

10M TARGET LINE

15M TARGET LINE

25M TARGET LINE

AF2AF2AF2AF2AF2AF2

AF2AF2AF2

S4NS4NS4N

A5 A-301

AF2AF2

102'-0"

100'-0"

EX

IS

T

SL

OP

E

EX

IS

T

SL

OP

E

99'-5 3/4"

99'-5 3/4"

100'-0" 100'-0"

AF9AF9

READY LINE READY LINE

FIRING LINEFIRING LINE

AF13AF13

7B

M12G

M12G M12G

W1W1

AF7

AF7

AF7

AF7

AF7

AF7

B1

A-601 TYP

B1

A-601 TYP

A2

M-602

A2

M-602

AF5AF5 AF5AF5

1'- 4"

1'- 4"

TRAP

MAINTENANCE

TYP

AF12AF12 AF12

FEC FEC

FE

FE

AF2CHASE

CHASE

S4PS4P

S4N FE

NE

W

C

ON

ST

RU

CT

IO

N

EX

IS

T

RO

OF

S

TR

UC

TU

RE

T

O

RE

M

AI

N

A-601 B2

A-601 B2

TYP

AF9

AF9 AF9

AF9

AF9

AF9

AF9

AF9

AF9

AF9

AF9

AF9 AF9

AF9

M8H M8H

1'-0" 9'-2" 9'-2" 1'-0"

AF12

3'-0" 3'-4" 2'-0" 3'-0" 3'-4"3'-4" 2'-8" 4'-8" 3'-4" 5'-8"

AF12 AF12

AF8

TYP AF8

TYP

AF6 AF6

3'-0"

2'- 8"

8'- 0"

6'- 0"

3'-4" 3'-4"

6'- 0"

9'- 4"

7"

6'- 0"

6'- 0"

13'-0"13'-0"7'-0" 7'-0"

AF8AF8

AF9

AF15

A-601 C1

TYP

A-601 C2

TYP

AF9

A-601 C2

SIMA-601

C2

SIM

'-8

AF7

1. FINISH FLOOR ELEVATION (FFE) 100'-0" EQUALS 893.95' ON THE CIVIL

DRAWINGS.

2. ALL PENETRATIONS THROUGH NON-RATED FLOORS, WALLS AND

OTHER ASSEMBLIES SHALL BE SEALED AT BOTH SIDES WITH

MATERIALS APPROPRIATE TO THE ASSEMBLY CONSTRUCTION TO

REDUCE SOUND TRANSMISSION.

3. ALL PENETRATIONS THROUGH FIRE-RATED FLOORS, WALLS, AND

OTHER ASSEMBLIES SHALL BE PROTECTED BY MATERIALS AND

INSTALLATION DETAILS THAT CONFORM TO UL OR OTHER APPROVED

LISTINGS AND MATCH THE RATING OF THE CONSTRUCTION BEING

PENETRATED.

4. PROVIDE SOLID WOOD BLOCKING AS REQUIRED TO SUPPORT ALL

WALL MOUNTED ITEMS (INCLUDING, BUT NOT LIMITED TO, MAP

RAILS, MARKER BOARDS, SIGNAGE, CASEWORK, MILLWORK, AND

TOILET ACCESSORIES).

5. PROVIDE SOLID WOOD BLOCKING AT RAILINGS AND GUARDRAILS

CAPABLE OF SUPPORTING THE POINT AND UNIFORM LOADS

REQUIRED BY CODE.

6. VERIFY CLEARANCES REQUIRED FOR INSTALLATION OF ALL

RECESSED OR SEMI-RECESSED EQUIPMENT AND FIXTURES (E.G.

CABINETS, DISPENSERS, PANELS, ETC.). NOTIFY ARCHITECT

IMMEDIATELY IF SPECIFIED WALL TYPES DO NOT PROVIDE

ADEQUATE SPACE FOR PROPER INSTALLATION.

7. FLOOR PLAN DIMENSIONS ARE LOCATED FROM THE FINISHED FACE

OF PARTITIONS, UNLESS NOTED OTHERWISE.

8. ALL MASONRY DIMENSIONS ARE NOMINAL UNLESS NOTED

OTHERWISE.

9. DO NOT SCALE DRAWINGS; DIMENSIONS SHALL GOVERN.

10. EXTERIOR WALL CONSTRUCTION SHOWN ON WALL SECTIONS.

11. LOCATE DOOR FRAMES 4” CLEAR FROM ADJACENT PERPENDICULAR

WALLS UNLESS NOTED OTHERWISE.

FLOOR PLAN GENERAL NOTES

G - GROUT SOLID

PARTITION TYPE SYMBOL

PARTITION

DESIGNATION M12G

MATERIAL

NOMINAL

THICKNESS OPTION(S)

STUDS

CMU

S =

M = 7 5/8" MASONRY8 =

11 5/8" MASONRY12 =

3 5/8" STUD4 =

P - 3/16 PERFORATED

METAL BOTH SIDES

BRACE TO EXT

WALL AS REQUIRED

PARTITION TYPES LEGEND

ALL PARTITIONS EXTEND TO STRUCTURE UNLESS NOTED OTHERWISE

N - NON-PERFORATED

METAL SHEET

H - PARTIAL HEIGHT

WALL TO 7'-0"

FLOOR PLAN LEGEND

EXISTING WALL

NEW WALL

EXISTING DOOR

NEW DOOR

LEO A DALY Company 2014

A

B

C

D

A

B

C

D

2 3 4 5

P L

A N

N I N

G A

R C

H I T

E C

T U

R E

E N

G I N

E E

R I N

G I

N T

E R

I O

R S

ES

T

S ec o n d A ve n u e

So u th

Su it e

M in n ea p o li s, M N

-2

U

SA

T el

-3

-8

F ax

-3

-4

GR

AN

D

FO

RK

S

AF

B, N D

CO

NT

RA

CT

S

EL

EM

EN

T

9 C

IV

IL

EN

GI

NE

ER

S

QU

AD

RO

N

AI

R

MO

BI

LIT

Y

CO

MM

AN

D

DE

PA

RT

ME

NT

O

F

TH

E

AI

R

FO

RC

E

PR

OJ

EC

T

NU

MB

ER

PL

OT

S

CA

LE

A S

IN

DI

CA

TE

D

PL

OT

D

AT

E:

CH

K

BY

DW

N

BY

DE

SI

GN

ED

B Y:

FI

LE

N

AM

E:

DA

TE

1 2 3 4 5

Sheet of 36

/1

/2

:0 :0

P

M

FL

OO

R

PL

AN

A-101

JF

SD

A

DD

/R

EP

AI

R

SM

AL

L A

RM

S

RA

NG

E

GR

AN

D

FO

RK

S

AF

B, N

OR

TH

D

AK

OT

A

1-

5-

/23

/1

RF

B

JR

G

JM

T

ISSUED FOR BID/

CONSTRUCTION

JF

SD

_B

4_ A-

/23

/1

SCALE: 1/8" = 1'-0"A-101

A1 LEVEL 1 - FLOOR PLAN

FLOOR PLAN KEYNOTES

AF1 INSTALL METAL WALL PANELS ON EXISTING WOOD SIDING,

ENTIRE FIRING PLATFORM BUILDING.

AF2 WALL SHEATHING INFILL AT REMOVED WINDOWS OR DOORS.

MATCH ADJACENT CONSTRUCTION OF 1/2" EXTERIOR PLYWOOD,

2 X 6 WOOD FRAMING & 1/2" INTERIOR WOOD PANELING. STAIN

PANELING TO MATCH EXISTING WHERE VISIBLE.

AF3 STAINLESS STEEL LOADING COUNTER

AF4 MECHANICAL PLENUM WALL

AF5 RUBBER TILE FLOORING TO EXTENTS SHOWN.

AF6 EQUIPMENT STOOP

AF7 REPLACE 2 LAYERS OF PLYWOOD ON FRONT FACE OF EXISTING

BAFFLE WITH 2 LAYERS FIRE RETARDANT PLYWOOD SHEATHING

ABOVE. STAGGER JOINTS.

AF8 2" THICK ACOUSTIC BALLISTIC PANELS OVER CMU WALLS FROM

T.O. FLOOR SLAB TO ROOF DECK.

AF9 2" THICK ACOUSTIC BALLISTIC PANELS OVER COLUMN.

AF10 CONCRETE STOOP

AF11 NEW CONCRETE SLAB THROUGHOUT DOWNRANGE & TRAP

MAINTENANCE AREA. SEE STRUCTURAL FOR THICKNESS.

AF12 DOWNSPOUT & CONCRETE SPLASH BLOCK.

AF13 GRANULAR RUBBER BULLET TRAP

AF14 REPLACE 2 LAYERS OF 3/4" PLYWOOD ON EXISTING OVERHEAD

CANOPY WITH 2 LAYERS FIRE RETARDANT PLYWOOD

SHEATHING. STAGGER JOINTS.

AF15 2" THICK ACOUSTIC BALLISTIC PANELS OVER 2 LAYERS OF 3/4"

PLYWOOD OVER EXISTING COLUMN FURRING.

NTRUE

NORTH

N O

D

ES

C

R

IP

T

IO

N D

A T E

IS

SU

ED

F O

R B

ID

C

O N

ST

R U

C T

IO

N /2

/1

LEVEL 1

100'-0"

A-1.7

VARIES

TOW

CONCRETE SLAB,

SEE STRUCTURAL

2" ACOUSTIC BALLISTIC PANEL

TO ROOF DECK

12" CMU WALL

GROUT SOLID

EXISTING METAL ROOF

A-301 A3

NOTE: MODIFY EXISTING

ROOF STRUCTURE/ROOFING

TO BEAR ON NEW FRAMING

NOTE: CUT AT BALLISTIC PANEL

AROUND ALL OBSTACLES, INSTALL

TIGHT & TRUE TO ALL

PENETRATIONS

LEVEL 1

100'-0"

AAR-6

ROOF

118'-3"

BARARBRCRDRERFRGRHR-1

113'-6"

TOW

12" CMU

GROUT SOLID

GRANULAR RUBBER

BULLET TRAP &

FRAME

EXISTING ROOFNEW ROOF

2" ACOUSTIC BALLISTIC

PANELS OVER COLUMN

TO ROOF DECK BEYOND CONCRETE SLAB,

SEE STRUCTURAL

B.O. DUCT

EXIST HM FRAME

AT REMOVED

FIRING LINE DOOR

METAL PANEL OVER EXISTING SHEATHING

PERFORATED METAL

PLENUM WALL

STANDING SEAM

METAL ROOF

EXISTING ASPHALT

SHINGLE ROOF

2" ACOUSTIC BALLISTIC

PANELS OVER COLUMNS

TO ROOF DECK BEYOND

107'-3"

EXISTING FOUNDATION

7'- 6"

REPLACE 2 LAYERS

OF 3/4" PLYWOOD

WITH FIRE RETARDANT

PLYWOOD SHEATHING

ON FRONT FACE

STAGGER JOINTS

REPLACE 2 LAYERS

OF 3/4" PLYWOOD

WITH FIRE RETARDANT

PLYWOOD SHEATHING

STAGGER JOINTS

REPLACE 2 LAYERS

OF 3/4" PLYWOOD

WITH FIRE RETARDANT

PLYWOOD SHEATHING

ON FRONT FACE

STAGGER JOINTS

OVERHEAD

BAFFLES

DESIGNED BY

SUPPLIER

2" ACOUSTIC BALLISTIC

PANELS FULL HEIGHT

FROM FLOOR SLAB TO

ROOF DECK

A-301 B2

A-301 A2

EXISTING METAL

ROOF TO REMAIN

SLOPE +/1 1/2"/FT

EXISTING STRUCTURE/ROOF

ASSEMBLY TO REMAIN

BLACKOUT COATING

ON EXISTING SKYLIGHT

NEW CMU WALL (IN FRONT OF

PLANE AT SECTION CUT)

ALIGN FRAME WITH

ACOUSTIC BALLISTIC

PANELS ON COLUMN

HANGER AS REQUIRED

FOR SUPPORT

6" 6"

8'- 0"

12.00°

LINE OF FIRE

SLOTTED CHANNEL FRAMING

PROVIDED BY OVERHEAD

BAFFLE INSTALLER PER

SPEC SECTION 05 43 00

10"

LEVEL 1

100'-0"

A-1.7

VARIES

TOW

8'- 0"

12" CMU WALL

GROUT SOLID

CONCRETE

STOOP

NEW STANDING SEAM

METAL ROOF

CONCRETE SLAB,

SEE STRUCTURAL

A-601 B4

A-301 B3

OVERHEAD SECTIONAL DOOR

1"

NEW STANDING SEAM METAL ROOFING

ASSEMBLY. SEE /A1 A-301

2x PRESSURE TREATED BLOCKING

MAINTAIN CLEAR

SEALANT

NEW CMU WALL WITH 2" ACOUSTIC

BALLISTIC PANEL ON INTERIOR FACE

.040" ALUM PLATE (CONT.)

CONTINUOUS TRIM

MA

TC

H

FA

CI

A

PR

OF

ILE

D

EP

TH

A T

EX

IS

T

RO

OF

EXTEND WATER BARRIER DOWN ROOF

EDGE AS SHOWN

3"

1"

1"

SEALANT

NEW CMU WALL WITH 2" ACOUSTIC

BALLISTIC PANEL ON INTERIOR FACE

EXIST 6" Z PURLIN

EXIST METAL ROOF

12 GA STEEL ANGLE, SEE STRUCTURAL

MAINTAIN CLEAR

NEW 2x PRESSURE TREATED

BLOCKING (CONTINUOUS)

CUT BACK EXIST METAL ROOF AS

REQUIRED TO CREATE CONT HEM AS

SHOWN

CUT T.O. CMU TO SLOPE AS REQUIRED

SEALANT AT HEM JOINT (TYP)

CONTINUOUS FASCIA TRIM W/ 1"

EXPANSION SLOT AS SHOWN

.040" ALUM PLATE (CONT.)

2"

7"

MAINTAIN CLEAR

1"

SS ROOF ASSEMBLY

SEE

TRIM AT ROOFING & GUTTER

GUTTER SPACER ALIGN

WITH BRACKETS OC

NEW CMU WALL

ALUM GUTTER (CONT)

GUTTER BRACKET @ 18" OC.

MIN 16 GA ALUM, COLOR TO

MATCH TRIM, MECH FASTEN TO

STL ANGLE AT ROOF DECK LIMIT

NOTE: TOTAL (6) 4"x6" DOWNSPOUTS

SEE BUILDING ELEVATION.

/A1 A-301

1"

7"

CONTINUOUS METAL FLASHING

AT TOP OF NEW SHEATHING

NEW FRAMING AS REQUIRED AT

FOUR SIDES OF OPENING

NEW METAL WALL PANEL ASSEMBLY

SEE

NEW SHEATHING

/B5 A-201

1"

+/- 8" 1/2"EPDM MIN 6"

WATER BARRIER

EXTEND ACROSS

MODIFY EXISTING ROOFING TO

RECEIVE FASCIA TRIM AS SHOWN,

TRIM & CRIMP

NEW PRESSURE TREATED WOOD

BLOCKING (CONTINUOUS)

T.O. CMU (BEYOND)

.60" EPDM - ATTACH AT NEW BLOCKING,

EXTEND ACROSS NEW ROOF SHEATHING

AS SHOWN

MAINTAIN CLEAR

T.O. CMU BEYOND

NEW STANDING SEAM METAL

ROOF ASSEMBLY

2"

STANDING SEAM METAL ROOF PANELS

SLIP SHEET

WATER BARRIER

3/4" PLYWOOD ROOF SHEATHING

METAL DECK, SEE STRUCTURAL

LEO A DALY Company 2014

A

B

C

D

A

B

C

D

2 3 4 5

P L

A N

N I N

G A

R C

H I T

E C

T U

R E

E N

G I N

E E

R I N

G I

N T

E R

I O

R S

ES

T

S ec o n d A ve n u e

So u th

Su it e

M in n ea p o li s, -2

U

SA

T el

-3

-8

F ax

-3

-4

GR

AN

D

FO

RK

S

AF

B, N D

CO

NT

RA

CT

S

EL

EM

EN

T

9 C

IV

IL

EN

GI

NE

ER

S

QU

AD

RO

N

AI

R

MO

BI

LIT

Y

CO

MM

AN

D

DE

PA

RT

ME

NT

O

F

TH

E

AI

R

FO

RC

E

PR

OJ

EC

T

NU

MB

ER

PL

OT

S

CA

LE

A S

IN

DI

CA

TE

D

PL

OT

D

AT

E:

CH

K

BY

DW

N

BY

DE

SI

GN

ED

B Y:

FI

LE

N

AM

E:

DA

TE

1 2 3 4 5

Sheet of 36

/1

/2

:0 :3

P

M

W

AL

L S

EC

TI

ON

S

DE

TA

ILS

A-301

JF

SD

A

DD

/R

EP

AI

R

SM

AL

L A

RM

S

RA

NG

E

GR

AN

D

FO

RK

S

AF

B, N

OR

TH

D

AK

OT

A

1-

5-

/23

/1

RF

B

JR

G

JM

T

ISSUED FOR BID/

CONSTRUCTION

JF

SD

_B

4_ A-

/23

/1

SCALE: 1/4" = 1'-0"A-301

A4 WALL SECTION AT EXISTING ROOF

SCALE: 3/16" = 1'-0"A-301

C1 BUILDING SECTION

SCALE: 1/4" = 1'-0"A-301

A5 WALL SECTION AT NEW ROOF

SCALE: 3" = 1'-0"A-301

B3 ROOF EDGE AT NEW ROOF

SCALE: 3" = 1'-0"A-301

A3 ROOF EDGE AT EXISTING ROOF

SCALE: 3" = 1'-0"A-301

A2 ROOF EDGE AT GUTTER

SCALE: 3" = 1'-0"A-301

B1 HEAD DETAIL AT WALL INFILL

SCALE: 3" = 1'-0"A-301

B2 NEW & EXISTING ROOF

SCALE: 3" = 1'-0"A-301

A1 NEW STANDING SEAM METAL ROOF ASSEMBLY

N O

D

ES

C

R

IP

T

IO

N D

A T E

IS

SU

ED

F O

R B

ID

C

O N

ST

R U

C T

IO

N /2

/1

LEO A DALY Company 2014

A

B

C

D

A

B

C

D

2 3 4 5

P L

A N

N I N

G A

R C

H I T

E C

T U

R E

E N

G I N

E E

R I N

G I N

T E

R I O

R S

ES

T

S ec o n d A ve n u e

So u th

Su it e

M in n ea p o li s, -2

U

SA

T el

-3

-8

F ax

-3

-4

1 2 3 4 5

/1

/2

:2

:1

A

M

E-121

N

FLOOR PLAN KEYNOTES

EP01 PROVIDE WEATHERPROOF DUPLEX GFI RECEPTACLE WITH

ALUMINUM EXTRA-DUTY "IN-USE" COVER FOR OWNER'S TARGET

RETRIEVAL SYSTEM. COVER SHALL BE EXTRA DEEP TYPE TO

ENSURE COVER WILL CLOSE WITH CORDS AND PLUGS INSERTED.

EP02 EXISTING RECEPTACLE LOCATIONS AT RANGE CONTROL STATION

TO REMAIN. CONNECT TO BRANCH CIRCUITING INDICATED.

EP03 EXISTING TELEPHONE LOCATION TO REMAIN. PROVIDE 3/4"

CONDUIT WITH CAT-5E CABLE TO RELOCATED TELEPHONE

ENCLOSURE IN ROOM 104.

EP04 PROVIDE CONNECTION TO INFRARED HEATER AND ASSOCIATED

CONTROLLER MOUNTED ADJACENT TO UNIT. COORDINATE

CONNECTIONS AND LOCATIONS WITH MECHANICAL

CONTRACTOR. PROVIDE #10 AWG CONDUCTORS IN HOMERUN.

EP05 PROVIDE DOUBLE DUPLEX RECEPTACLES FOR OWNER'S SOUND

SYSTEM. VERIFY LOCATION AND MOUNTING HEIGHT WITH

OWNER.

EP06 PROVIDE 240V, 3 POLE, NEMA 3R, NON-FUSED DISCONNECT

SWITCH AT UNIT. COORDINATE INSTALLATION AND CONNECTION

REQUIREMENTS WITH MECHANICAL CONTRACTOR. SEE DETAIL

1/E-601 FOR ADDITIONAL INFORMATION.

EP07 PROVIDE INTERMATIC #FF4H, SPRING WOUND, 0 - 4 HOUR,

WALLBOX TIMER TO OPERATE INFRARED HEATERS. PROVIDE

CONNECTION TO INFRARED HEATER CONTACTOR. COORDINATE

LOCATION WITH USER. LABEL "INFRARED HEATERS".

EP08 PROVIDE 240V, 3P, NEMA 1, SIZE 2, FUSIBLE COMBINATION

STARTERS FOR MAU-1, MAU-2, EF-1 & EF-2. PROVIDE TIME DELAY

FUSES. PROVIDE WITH H-O-A SWITCHES AND GREEN LED

RUNNING LIGHTS. MOUNT AT 66" TO TOP OF ENCLOSURE.

COORDINATE INSTALLATION WITH MECHANICAL CONTRACTOR.

SEE DETAIL 1/E-601 FOR ADDITIONAL INFORMATION.

EP09 PROVIDE 120V POWER CONNECTION TO HVAC SYSTEM CONTROL

PANEL. COORDINATE LOCATION WITH MECHANICAL

CONTRACTOR.

EP10 NOT USED

EP11 OWNER'S SOUND SYSTEM SPEAKER. PROVIDE 1/2" CONDUIT

FROM OWNER'S SPEAKER LOCATIONS TO ROOM 104. PROVIDE

PULLCORD IN CONDUIT. VERIFY SPEAKER LOCATIONS WITH

OWNER.

N O

D

ES

C

R

IP

T

IO

N D

A T E

IS

SU

ED

F O

R B

ID

C

O N

ST

R

U C

T

IO

N /2

/1

R

EV

IS

ED

F O

R N

A T G

A S

-J

U N

-1

File details come from the government source that posted it. Updated .