Attachment_3_-_Questions_and_Answers.pdf

PDF 182 KB Posted

Attached to
Range Retrieval System Installation & Training Federal contract opportunity
Solicitation number
FA4659-16-Q-0027
Issued by
Department of the Air Force Air Mobility Command

About this file

Attachment 3 - Questions and Answers

View the file

Other files for this federal contract opportunity

Other files attached to Range Retrieval System Installation & Training, newest first.
File Type Posted
Combo_amendment_0003.pdf PDF
Questions_and_Answers_2.docx DOCX document
Combo_amendment_0002.pdf PDF
Attachment_4_-_Range_Drawings.pdf PDF
Attachment_5_-_steel_plate.PNG PNG image
Attachment_6_-_List_of_Site_Visit_Attendees.pdf PDF
Combo_amendment_0001.pdf PDF
Combo.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Questions and Answers to RFQ FA4659-16-Q-0027 dated 7 Sep 2016

Q.1. Can you provide current drawings of the range so that dimensions can be verified?

A.1. See the attached range drawings.

Q.2. What is the distance between each of the baffles as well as the distance from the last baffle to the start of the bullet trap?

A.2. See the attached range drawings.

Q.3. One of our target retriever options requires a 220-volt, two phase outlet. Is this power available on the range?

A3. There is no 220 power available for them. See the attached range drawings.

Q.4. I just have a question regarding the above referenced RFQ for a Target System at the Grand Forks AFB range. The bid specifications identify that the system needs to be made from “rust proof / resistant steel or a durable like material that is weather resistance”. We have 2 versions of target system that will fit your specification requirements, they are: Indoor target system or Outdoor target system. Which target system do you want me to bid?

A.4. Weather resistant is required due to the extreme temperature change from hot too cold with weather here that will cause condensation on the equipment.

Q.5. The Statement of Work for this solicitation states that "The carrier should be faced with a minimum of 3/8" steel plate on the front of the carrier facing the shooters". Our target retriever has been designed with a carefully engineered angle to deflect rifle and handgun bullet impacts toward the trap and away from the shooters. With the angle of this design, we have found that a 1/4" AR500 deflector plate is sufficient for both handgun and rifle rounds and would like to know if this will meet the minimum requirement.

A.5. See the attached excerpt from ETL 11-18 with required steel plate thickness. 3/8" or 10mm is minimum. Nothing about angles stated in ETL just the minimum thickness.

Q.6. Is there a requirement/qualification that the provider demonstrate past performance in providing targetry for the Military?

A.6. Past performance is not required to be submitted in response to this solicitation.