Attachment_1.xlsx
XLSX spreadsheet 15 KB Posted
- Attached to
- Fire Protection And Emergency Services Federal contract opportunity
- Solicitation number
- FA4659-15-R-0016
About this file
Attachment 1 for Amendment 0004.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Attachment_2.pdf | ||
| Attachment_3.pdf | ||
| Fire_Amendment_0004.pdf | ||
| Correct_Fire_CBA_April_2014.pdf | ||
| Fire_Financial_Institution_Reference_Sheet.pdf | ||
| Solicitation_FA4659-15-R-0016.pdf | ||
| PWS_dated_8_June_2015.pdf | ||
| QASP_25_March_2015.pdf | ||
| Fire_Solicitation_Cover_Letter.pdf | ||
| Fire_CBA_April_2014.pdf | ||
| Wage_Determination_05-2407_Dated_8_June_2015.pdf | ||
| FIRE_Past_Performance_Questionnaire.pdf | ||
| FA4659-15-R-0016_Solicitation.pdf |
Show all 13
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Year Condition
| Note: | ||||||||
| TURN-OUT (COATS) | CONDITON | 1. The NFPA requirements for PPE is ten years from manufacture date for in service. | ||||||
| Year Mfg | No. | Good | Fair | Poor | O/S | 2. NFPA requires all PPE to be fitted to the user. | ||
| 1992 | 1 | 1 | 3. NFPA requires the thermal liners to be annual hydro tested. | |||||
| 2001 | 1 | 1 | 4. NFPA requires annual cleaning and as needed. This can reduce the in-service life 50-60 percent. | |||||
| 2002 | 1 | 1 | 5. DoD and AF Fire training requirements are comprehensive, stringent, realistic and aggressive. “Train how we fight” These requirements are more stringent and comprehensive than any other agency, whether federal, state or local. | |||||
| 2003 | 2 | 2 | 6. Gloves and Nomex Hoods usually last 12-15 months. Gloves need to match type of ensemble issued…wristlet or gauntlet style. | |||||
| 2010 | 17 | 7 | 10 | 7. Suspenders last 24-48 months. | ||||
| 2011 | 19 | 17 | 1 | 1 | 8. Helmets the hard shell normally will last 7-10 years, inside head gear will last 4-5 years and cannot be re-issued | |||
| 2015 | 9 | 9 | 9. Boots last 5-6 years and cannot be re-issued and have to be sized correctly. | |||||
| Old - No Data | 1 | 1 | Due to the past history of GFE funded PPE. There has been short falls at contract re-bid time. I have personally inspected every GFE PPE piece and assigned a condition code to assist in correcting these shortfalls. | |||||
| TOTAL | 51 | 33 | 11 | 7 | Good | This means it should last 4 or more years | ||
| Fair | This means it should last up to 2 years | |||||||
| TURN-OUT (Pants) | CONDITON | Poor | This means it will need replacing 3-6 months | |||||
| Year Mfg | No. | Good | Fair | Poor | O/S | Date | Out of Service | |
| 1992 | 1 | 1 | Repair | Out of Service | ||||
| 2000 | 1 | 1 | ||||||
| 2001 | 1 | 1 | There are current sizing, out-dated and non-compliant issues currently in-service issues with several firefighters: | |||||
| 2002 | 1 | 1 | 1. Coats: Need 1 Globe coat 44 X 32 | |||||
| 2003 | 2 | 2 | 2. Pants: Need 5 Globe pants 40 X 30, 44 X 34, 46 X 32, 44 X 32, 40 X 32 | |||||
| 2010 | 18 | 6 | 11 | 1 | 3. Boots: All compliant | |||
| 2011 | 20 | 19 | 1 | 4. Gloves: Need 1 (M) 1 (L) Gauntlet, 1 (XL) 1 (M) wristlet | ||||
| 2015 | 9 | 9 | 5. Helmets: Need 8 out-dated currently in service | |||||
| TOTAL | 53 | 34 | 12 | 0 | 7 | 6. Nomex Hoods: 24 hoods need replacing | ||
| Required for a 20% bench stock on on. All out of service items need to be turned in and replaced with compliant items. | ||||||||
| HELMETS | CONDITON | The Chart on left includes bench stock items. Listed below are the numbers of each and condition in bench stock: (RESERVE STOCK & OUT OF SERVICE STOCK) | ||||||
| Year Mfg | No. | Good | Fair | Poor | O/S | 1. Coats: 5 are in good condition, but sizing on 3 are way too large, fits no one and do not see them fitting anyone in the future. 3 are in fair conditions, with 1 having a sizing issue. 7 are out of service needing replacement, with 1 needing repair to return to service | ||
| 1992 | 5 | 5 | 2. Pants: 6 are in good condition, sizing issue with 2, 4 are fair condition, with two sizing issues, 8 are out of service needing replacement | |||||
| 1994 | 7 | 7 | 3. Boots: 7 sets are good conditions, 3 being new. There are 8 that out of service; need replacing. | |||||
| 2003 | 3 | 1 | 2 | 4. Gloves: 2 used sets in good condition. Sizes do not fit | ||||
| 2009 | 2 | 2 | 5. Helmets: 3 are new, but have no face shields, 8 are out of service and need replacing | |||||
| 2011 | 20 | 17 | 3 | 6. Nomex hoods: There are zero in supply, need to have 8 for bench stock. . | ||||
| 2015 | 9 | 9 | ||||||
| Old - No Data | 1 | 1 | ||||||
| TOTAL | 47 | 28 | 0 | 1 | 18 |
| Structural Fire Boots | CONDITON | ||||
| Year Mfg | No. | Good | Fair | Poor | O/S |
| 2003 | 2 | 2 | |||
| 2007 | 4 | 4 | |||
| 2010 | 9 | 8 | 1 | ||
| 2011 | 20 | 20 | |||
| 2013 | 1 | 1 | |||
| 2014 | 9 | 9 | |||
| Old - No Data | 6 | 6 | |||
| TOTAL | 51 | 42 | 1 | 0 | 8 |
| Nomex Hoods | CONDITON | ||||
| Year Mfg | No. | Good | Fair | Poor | O/S |
| 1996 | 1 | 1 | |||
| 2002 | 2 | 2 | |||
| 2004 | 1 | 1 | |||
| 2009 | 1 | 1 | |||
| 2010 | 1 | 1 | |||
| 2011 | 16 | 12 | 4 | ||
| 2015 | 7 | 7 | |||
| Old - No Data (N/C) | 7 | 7 | |||
| TOTAL | 36 | 7 | 12 | 12 | 5 |
| Structural Fire Gloves | CONDITON | ||||
| Year Mfg | No. | Good | Fair | Poor | O/S |
| 2006 | 4 | 2 | 2 | ||
| 2007 | 1 | 1 | |||
| 2009 | 2 | 2 | |||
| 2010 | 3 | 3 | |||
| 2011 | 19 | 17 | 2 | ||
| 2013 | 2 | 2 | |||
| 2014 | 7 | 7 | |||
| TOTAL | 38 | 33 | 5 | 0 | 0 |
File details come from the government source that posted it. Updated .