2013-10-18_B-1702_ACM_Survey_Report.pdf
PDF 998 KB Posted
- Attached to
- Demolition of Bldg. 1702 Federal contract opportunity
- Solicitation number
- FA462619Q0091
About this file
Pre-Demolition Asbestos Assessment which was preformed on October 18, 2013
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Q&A_2.pdf | ||
| B-1702_Water_Demolition.pdf | ||
| Q&A.pdf | ||
| Addendum__1.pdf | ||
| Building_Plans.pdf | ||
| Tab3-COMBO-Attachment_2.pdf | ||
| Tab3-COMBO-Attachment_1.pdf | ||
| Tab3-COMB-Attachment_3.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
LIMITED, PRE-DEMOLITION ASBESTOS ASSESSMENT
Building 2041 – Medical Readiness Facility 7300 N. Perimeter Road Malmstrom AFB, MT 59402
Prepared For:
VW International, Inc.
7300 North Perimeter Road Malmstrom AFB, Montana 59402
Prepared By:
CTA Construction & Environmental, LLC
219 Second Avenue South Great Falls, Montana 59405
(406) 452-3321 office
(406) 454-1873 fax www.ctagroup.com
CTA Project No. GF13076
October 18, 2013
Limited Pre-Demolition Asbestos Assessment – Building 1702
7300 N. Perimeter Rd, Malmstrom Air Force Base, MT, 59402
CTA Project No.:
GF13076
CTA Construction & Environmental, LLC i
TABLE OF CONTENTS
1.0 EXECUTIVE SUMMARY
2.0 INTRODUCTION
2.1 Scope of Work
3.0 SITE DESCRIPTION
4.0 REGULATORY CONSIDERATIONS
5.0 METHODS
6.0 RESULTS
7.0 RECOMMENDATIONS
8.0 LIMITATIONS
APPENDICES
Appendix A – Documentation of Accreditation Appendix B – Figure Appendix C – Data Summary Table Appendix D – Laboratory Analytical Reports
CTA Construction & Environmental, LLC 1
1.0 EXECUTIVE SUMMARY
VW International, Inc. (VWI), contracted with CTA Construction & Environmental, LLC (CTA), to complete a limited, Pre-Demolition Asbestos Assessment of the Bioenvironmental Engineering
Facility (Building 1702) located at 7300 N. Perimeter Road, Malmstrom Air Force Base, MT, 59402. The assessment was completed in accordance with VWI’s Purchase Order No. 6458-
12B-3021, Work Order Number 1301031 and associated CTA Work Order GF13076, dated
September 4, 2013.
A total of 24 separate homogeneous areas (HAs) of building materials were identified and sampled as being suspect asbestos-containing materials (ACM) during the assessment. None of the aforementioned HAs were lab-determined to contain asbestos; therefore, these materials have all been lab-determined to be non-ACM.
CTA Construction & Environmental, LLC 2
2.0 INTRODUCTION
VWI requested CTA perform a pre-renovation asbestos assessment to identify materials potentially containing asbestos at the site prior to future implementation of their planned demolition of the site building.
Scope of Work 2.1
The scope of work for this project included assessment of building materials and components throughout accessible interior and exterior areas of all site structures, including visual assessment, sampling, and documentation of suspect ACM.
CTA’s scope of work for this project did not include preparation of abatement plans or specification documents, nor did it include any abatement, oversight, or clearance monitoring activities.
CTA Construction & Environmental, LLC 3
3.0 SITE DESCRIPTION
Building 1702 is a two-level, slab-on-grade structure. Interior completions generally include the following: painted Gypsum Wallboard (GWB) system; a variety of sheet flooring, floor tiles, and carpeting, all with associated mastics; and, a variety of vinyl base coves with associated mastics. Exterior completions generally include: EPDMS roofing system; and, siding panels exhibiting a pebble-encased skim coat surface and tan caulking between adjoining panel areas.
CTA Construction & Environmental, LLC 4
4.0 REGULATORY CONSIDERATIONS
The Montana Department of Environmental Quality (DEQ) defines ACM as material containing more than 1% asbestos based on laboratory analysis of the material using the EPA Method
600/R-93/116 (“Method for the Determination of Asbestos in Bulk Building Materials”) by
Polarized Light Microscopy (PLM). Three categories of ACM have been defined in the National
Emissions Standards for Hazardous Air Pollutants (NESHAP) standard, which is established in
Title 40, Part 61, of the Code of Federal Regulations (40 CFR 61.141) and adopted by the DEQ in Title 17, Chapter 74, Subchapter 3, of the Administrative Rules of Montana (ARM 17.74.351).
The NESHAP category definitions are as follows:
� Category I Non-friable ACM mean asbestos-containing packings, gaskets, resilient floor coverings, and asphalt roofing products containing more than one (1) percent (%) asbestos as determined using the method specified in appendix E, subpart E, 40 CFR
763, section 1 (PLM).
� Category II Non-friable ACM means any material, excluding Category I Non-friable
ACM, containing more than 1% asbestos as determined using the method specified in appendix E, subpart E, 40 CFR 763, section 1, PLM that, when dry, cannot be crumbled, pulverized or reduced to powder by hand pressure.
� Regulated ACM (RACM) means a) friable asbestos material; b) Category I Non-friable
ACM that has become friable; c) Category I Non-friable ACM that will be or has been subjected to sanding, grinding, cutting, or abrading; or d) Category II non-friable ACM that has a high probability of becoming or has become crumbled, pulverized, or reduced to powder by the forces expected to act on the material in the course of demolition or renovation operations regulated by the subpart.
The definition of RACM includes all ACM associated with a structure or space which will be impacted by renovation and/or demolition activities. In other words, even non-friable
Category I and Category II ACM may become RACM if disturbed during demolition or renovation activities.
An “asbestos project,” as defined by Montana Code Annotated (MCA) 75-2-502, means the encapsulation, enclosure, removal, repair, renovation, placement in new construction, demolition of asbestos in a building or other structure, or the transportation or disposal of asbestos-containing waste. The term does not include a project that involves less than 3 square feet in surface area or 3 linear feet of pipe. Based on DEQ correspondence and CTA’s understanding of DEQ’s interpretation of the MCA, the removal, transport, and/or disposal of
RACM (or ACM which may become friable) in amounts exceeding this threshold value constitutes an “asbestos project.”
Prior to undertaking a renovation or demolition project, DEQ requires an asbestos inspection to be performed for the structure or portion of the structure to be included in the renovation or demolition project, in accordance with ARM 17.74.354. The inspection must be completed by a
Montana-accredited Asbestos Inspector. Following completion of the inspection, DEQ’s notification requirements should be considered, as follows:
CTA Construction & Environmental, LLC 5
� Project Permit Application – This application should be used for a renovation project where quantities of RACM exceeding the “asbestos project” threshold will be or are likely to be dislodged, disturbed, or impacted (or where any non-friable ACM may be made friable). The application must be submitted to the DEQ at least 10 working days prior to initiation of any activities which will dislodge, disturb, or impact RACM (and/or make friable any ACM), including all transport and disposal activities.
� Demolition Notification – This notification must be submitted to the DEQ prior to demolition of a structure in which no ACM was identified by the inspection.
� Project Permit Application & Demolition Notification – This application & notification should be used where an asbestos project and subsequent demolition will be completed, as described above. The application & notification must be submitted to the DEQ at least 10 working days prior to initiation of any activities which will dislodge, disturb, or impact RACM (and/or make friable any ACM), including all transport and disposal activities.
Asbestos projects must be performed by individuals holding current accreditation as Montana
Asbestos Contractor/Supervisors and/or Asbestos Workers, as stipulated under ARM
17.74.362. Asbestos projects are not considered complete until they have been “cleared” in accordance with the requirements set forth in ARM 17.74.357. It is important to note that clearance monitoring must be completed by a party not contractually associated with the asbestos project contractor, and there may not be any common ownership or employment relationship between the person or entity carrying out the asbestos project and the person or entity conducting the final clearance monitoring or sample analyses.
Demolition projects which will include in-place demolition of non-friable ACM (i.e. non-friable
ACM which will not be rendered friable during demolition activities) require the full-time, on-site oversight of an individual holding a current Montana Asbestos Contractor/Supervisor accreditation to ensure any ACM remaining in the structure is not rendered friable during demolition activities. Friable ACM waste (RACM) must be disposed at a Montana-licensed, Class II landfill. Non-friable ACM waste (Category I or Category II ACM) may be disposed at a
Montana-licensed, Class IV landfill. It is important to note, however, that some landfills will not accept asbestos waste, even if it is non-friable. Arrangements should be made with the landfill prior to initiation of abatement and/or demolition activities.
Handling of RACM, ACM, and non-ACM materials which contain detectable asbestos is regulated by the Occupational Safety and Health Administration (OSHA), as stipulated in 29
CFR 1926.1101. At all times, such materials must be handled in generally the same fashion as
RACM unless a negative exposure assessment is completed to document workers will not be exposed to airborne fiber concentrations in exceedance of the OSHA permissible exposure limit
(PEL) of 0.1 fibers per cubic centimeter (f/cc) as an eight-hour time-weighted average (8-hour
TWA) and the 30-minute, short term excursion limit (STEL) of 1.0 f/cc.
CTA Construction & Environmental, LLC 6
5.0 METHODS
This assessment, including accessible portions of the exterior and interior, was completed in general accordance with the requirements of the Montana DEQ Asbestos Control Program as established in ARM 17.74.354. In addition to complying with the regulations cited above, CTA’s sampling methods generally conformed to the requirements set forth in the Asbestos Hazard
Emergency Response Act (AHERA) as outlined in 40 CFR 763.86; the AHERA sampling methods are generally accepted as the industry standard for asbestos inspections. CTA’s asbestos inspection was performed by a member of our industrial hygiene staff holding current
DEQ accreditation as asbestos inspector. Observations and sample locations were recorded on field forms. Documentation of our inspector’s DEQ accreditations is presented as Appendix A, and sample locations for suspect ACM are presented as Figure 1 in Appendix B.
Bulk samples of suspect ACM were placed in pre-labeled zip-top bags and shipped to SanAir
Technologies Laboratory, Inc. (SanAir), in Powhatan, Virginia, using chain-of-custody protocol.
CTA requested that SanAir analyze the samples using the EPA Method 600/R-93/116 by polarized light microscopy (PLM), which has an analytical sensitivity of 1% asbestos by visual estimate. Where appropriate, CTA also requested that samples found to contain asbestos in concentrations less than 1% be analyzed using the 400 Point Count stipulation of the EPA PLM method to achieve an analytical sensitivity of 0.25%. All samples were analyzed using positive stop analysis. SanAir is accredited by the National Institute of Standards and Technology’s
(NIST) National Voluntary Laboratory Accreditation Program (NVLAP) for PLM analysis and therefore meets the proficiency requirements of the DEQ.
CTA Construction & Environmental, LLC 7
6.0 RESULTS
A total of 24 separate HAs of building materials were identified and sampled as being suspect -
ACM during the assessment. None of the aforementioned HAs were lab-determined to contain asbestos; therefore, these materials have all been classified as non-ACM.
A complete summary of all HAs of suspect ACM is presented in Table 1 of Appendix C. The summary tables includes descriptive locations of where each material sampled and additional locations where each was observed. The laboratory analytical reports are presented as
Appendix D.
CTA Construction & Environmental, LLC 8
7.0 RECOMMENDATIONS
Based on the aforementioned findings, and with consideration to the applicable regulations described herein, CTA presents the following recommendations.
CTA recommends that VWI proceed with their future-planned demolition of the site building without any special considerations for asbestos.
CTA further recommends that if additional (i.e materials not identified in this report) suspect materials are encountered (or are likely to be encountered) during future renovation and/or demolition activities, they should be sampled and analyzed to determine whether they are ACM, prior to being impacted by those activities.
CTA Construction & Environmental, LLC 9
8.0 LIMITATIONS
This report was prepared specifically for use by VWI, Inc. Use by any other entity is at the sole risk of the user(s). CTA’s assessment was completed with a standard of care meeting or exceeding that of other consultants performing similar work in this area. Our findings and recommendations are based on observations and data collected during our site visits and our professional interpretation of laboratory analytical data for samples collected during the project, as described above.
The scope of our building assessment was limited to those areas of the site as described in this report. Some portions of the site and/or specific materials were not sampled or analyzed during the assessment, for the reasons stated herein. If additional suspect materials are encountered
(or are likely to be encountered) during future renovation and/or demolition activities, they should be sampled and analyzed to determine whether they are ACM, prior to being impacted by those activities. The findings and conclusions of this report may not apply to future conditions at the site which we have not had the opportunity to evaluate.
We appreciate the opportunity to provide these industrial hygiene consulting services to VWI, Inc. If you have any questions regarding this project, or if we can be of service in another industrial hygiene and/or environmental consulting capacity, please contact our Great Falls office (406.452.3321).
Report Prepared By: Report Reviewed By:
Nathan Shumate Keith Cron, CIH
Environmental Scientist / Inspector Environmental Division Director
NateS@ctagroup.com KeithC@ctagroup.com
APPENDIX A
Documentation of Accreditation
APPENDIX B
Figure
APPENDIX C
Data Summary Table
HA
Number Material Description Location
Percent & Type of
Asbestos
In-Place
Condition
Anticipated
Abatement
Condition
B1.1 Black, 4-inch vinyl base cove. Room: Vest 100. Non-Detect NF Non-ACM
B1.2 Beige, 4-inch vinyl base cove. Rooms: Recept 100, 101-105, C1, 109, and 202. Non-Detect NF Non-ACM
B1.3 Brown, 4-inch vinyl base cove. Room: 106A. Non-Detect NF Non-ACM
B1.4 White, 4-inch vinyl base cove. Room: 109. Non-Detect NF Non-ACM
F2.1
Lavender-hued, 12 by 12-inch floor tiles with wavy mottles. Room: (2/3)101. Non-Detect NF Non-ACM
F4.1
Off-white sheet floor with small squared mottles and gray backing. Rooms: 106, 107, 109A (under carpet), and 202. Non-Detect NF/F Non-ACM
F4.2
Gray-hued sheet floor with multicolored, 1/4-inch mottles and gray backing. Room: 108. Non-Detect NF/F Non-ACM
G1.1
Gypsum wallboard system with tape and mud. Throughout all rooms. Non-Detect F Non-ACM
H3.1 Gray HVAC duct seam paste.
Room: 202, although assumed throughout ductwork. Non-Detect NF Non-ACM
M2.1 Light tan mastic located beneath F2.1. Room: (2/3)101. Non-Detect NF Non-ACM
M4.1
Light tan sheet flooring mastic located beneath F4.1. Rooms: 106, 107, 109A (under carpet), and 202. Non-Detect F Non-ACM
M4.2
Tan and amber sheet flooring mastics located beneath F4.2. Room: 108. Non-Detect NF Non-ACM
M5.1
Cream and residual tan base cove mastics located behind B1.1. Room: Vest 100. Non-Detect NF Non-ACM
M5.2
Cream base cove mastic located behind
B1.2. Rooms: Recept 100, 101-105, C1, 109, and 202. Non-Detect NF Non-ACM
M5.3
Dark brown base cove mastic located behind B1.3. Room: 106A. Non-Detect NF Non-ACM
TABLE 1
Summary of Homogenous Areas of Suspect ACM Building 1702 - Bioenvironmental Engineering, Malmstrom Air Force Base, Montana
Bldg 1702 - CTA Project GF13076 Page 1 of 2
HA
Number Material Description Location
Percent & Type of
Asbestos
In-Place
Condition
Anticipated
Abatement
Condition
M6.1 Beige and historic tan carpet mastics. Room: Vest 100. Non-Detect NF Non-ACM
M6.2
Clear to amber carpet mastics over historic tan mastic.
Rooms: Recept 100, 101-105, C1, 109, 200-201
(tan only), C2, C2A (tan only), 203-204 (tan only), 100A, and 109A (tan only). Non-Detect NF Non-ACM
R5.1
2-layered EPDMS membrane and particle board over felt paper. Exterior: Throughout roof. Non-Detect NF Non-ACM
S7.1 Pebble-encased skim coating. Exterior: Throughout siding. Non-Detect F Non-ACM
T2.1 Heavy orange-peel texturing. Rooms: Generally throughout interior. Non-Detect F Non-ACM
X1.1 Concrete. Throughout slab-on-grade, and sidewalks. Non-Detect NF Non-ACM
X3.1
Tan caulking for adjoining exterior siding panels. Exterior: Throughout siding panels. Non-Detect NF Non-ACM
X7.1 Black, spray-on sink undercoating. Room: (1)105. Non-Detect NF Non-ACM
X7.2 Black foundation sealant.
Exterior: Observed on SW portion of foundation, although assumed througout. Non-Detect F Non-ACM
Notes:
1 -
2 -
3 -
4 -
Material locations are based on arbitrary room designations assigned in the field by CTA for this assessment. When present, numbers in parentheses indicate the number of items identified in a given room; and fractions indicate an approximate portion of the respective room which contains the material.
The percentage of asbestos is reported based on PLM analysis using the EPA Method 600/R-93/116, with a limit of detection (LOD) of 1% by volume.
The In-Place Condition for each material was determined in the field by CTA's Montana-Accredited Asbestos Inspector(s). Materials are classified as either "F" for
"friable" or "NF" for "non-friable" based on their in-place condition at the time of the assessment , in accordance with the Montana Department of Environmental
Quality (DEQ) definitions for the respective terms.
The Anticipated Abatement Condition is based on the National Emissions Standards for Hazardous Air Pollutants (NESHAP) definitions for Category I (non-friable), Category II (non-friable), and Regulated Asbestos-Containing Material (RACM; friable), which have been adopted by the DEQ. For the purpose of this report, the
Anticipated Abatement Condition represents the anticipated condition of the material during removal . These determinations have been made by CTA based on the in-place condition and the professional experience and judgment of CTA's industrial hygienists. Materials assumed to contain greater than one percent (1%) asbestos may be referred to as Presumed Asbestos-Containing Material (PACM). Materials determined to contain less than 1% asbestos are non-asbestos-containing materials (Non-ACM) unless noted otherwise.
Bldg 1702 - CTA Project GF13076 Page 2 of 2
APPENDIX D
Laboratory Analytical Reports
SanAir Technologies LaboratorySanAir Technologies Laboratory
Analysis Report prepared for
CTA Construction & Environmental, LLC
Report Date: 10/15/2013 Project Name: WVI-Bldg 1702 Project #: GF 13076 SanAir ID#: 13024035
804.897.1177 www.sanair.com804.897.1177 www.sanair.com
SanAir Technologies Laboratory, Inc.
1551 Oakbridge Drive, Suite B, Powhatan, VA 23139
804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070
Web: http://www.sanair.com E-mail: iaq@sanair.com
CTA Construction & Environmental, LLC 219 2nd Ave South Great Falls, MT 59405
October 15, 2013
SanAir ID # 13024035 Project Name: WVI-Bldg 1702 Project Number: GF 13076
Dear Nate Shumate, We at SanAir would like to thank you for the work you recently submitted. The 76 sample(s) were received on Tuesday, October 08, 2013 via FedEx. The final report(s) is enclosed for the following sample(s): G1.1A, G1.1B, G1.1C, T2.1A, T2.1B, T2.1C, T2.1D, T2.1E, T2.1F, T2.1G, B1.1A, B1.1B, B1.1C, M5.1A, M5.1B, M5.1C, M6.1A, M6.1B, M6.1C, S7.1A, S7.1B, S7.1C, X3.1A, X3.1B, X3.1C, X1.1A, X1.1B, X1.1C, X7.2A, X7.2B, X7.2C, R5.1A, R5.1B, R5.1C, B1.2A, B1.2B, B1.2C, M5.2A, M5.2B, M5.2C, M6.2A, M6.2B, M6.2C, F2.1A, F2.1B, F2.1C, M2.1A, M2.1B, M2.1C, X7.1A, X7.1B, X7.1C, F4.1A, F4.1B, F4.1C, M4.1A, M4.1B, M4.1C, B1.3A, B1.3B, B1.3C, M5.3A, M5.3B, M5.3C, B1.4A, B1.4B, B1.4C, H3.1A, H3.1B, H3.1C, F4.2A, F4.2B, F4.2C, M4.2A, M4.2B, M4.2C.
These results only pertain to this job and should not be used in the interpretation of any other job.
This report is only complete in its entirety. Refer to the listing below of the pages included in a complete final report.
Sincerely, Sandra Sobrino Asbestos & Materials Laboratory Manager SanAir Technologies Laboratory
Final Report Includes:
- Cover Letter
- Analysis Pages
- Disclaimers and Additional Information sample conditions:
76 sample(s) in Good condition
804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070
Web: http://www.sanair.com E-mail: iaq@sanair.com
Name:
Address:
CTA Construction & Environmental, LLC 219 2nd Ave South Great Falls, MT 59405
Project Number:
P.O. Number:
Project Name:
GF 13076
WVI-Bldg 1702
Collected Date:
Received Date:
Report Date:
Analyst:
10/4/2013
10/8/2013 10:00:00 AM
10/15/2013 4:35:50 PM
Childress, Susan
Asbestos Bulk PLM EPA 600/R-93/116 Stereoscopic Components Asbestos
SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers G1.1A / 13024035-001 Various < 1% Cellulose 100% Other None Detected GWB With Tape And Mud/ 100 Non-Fibrous < 1% Glass
Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers G1.1B / 13024035-002 Various < 1% Cellulose 100% Other None Detected GWB With Tape And Mud/ 101 Non-Fibrous < 1% Glass
Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers G1.1C / 13024035-003 Various < 1% Cellulose 100% Other None Detected GWB With Tape And Mud/ 100A Non-Fibrous < 1% Glass
Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers T2.1A / 13024035-004 White 100% Other None Detected Heavy Texturing/V100 Non-Fibrous
Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers T2.1B / 13024035-005 White 100% Other None Detected Heavy Texturing/100B Non-Fibrous
Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers T2.1C / 13024035-006 White 100% Other None Detected Heavy Texturing/106 Non-Fibrous
Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers T2.1D / 13024035-007 White 100% Other None Detected Heavy Texturing/108 Non-Fibrous
Homogeneous
13024035 SanAir ID Number
FINAL REPORT
Certification
Signature: Reviewed:
Date: 10/15/2013 Date: 10/15/2013 Page 1 of 12
804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070
Web: http://www.sanair.com E-mail: iaq@sanair.com
Name:
Address:
CTA Construction & Environmental, LLC 219 2nd Ave South Great Falls, MT 59405
Project Number:
P.O. Number:
Project Name:
GF 13076
WVI-Bldg 1702
Collected Date:
Received Date:
Report Date:
Analyst:
10/4/2013
10/8/2013 10:00:00 AM
10/15/2013 4:35:50 PM
Childress, Susan
Asbestos Bulk PLM EPA 600/R-93/116 Stereoscopic Components Asbestos
SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers T2.1E / 13024035-008 White 100% Other None Detected Heavy Texturing/109A Non-Fibrous
Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers T2.1F / 13024035-009 White 100% Other None Detected Heavy Texturing/202 Non-Fibrous
Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers T2.1G / 13024035-010 White 100% Other None Detected Heavy Texturing/C2A Non-Fibrous
Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers B1.1A / 13024035-011 Black 100% Other None Detected 4-Inch Base Cove Over Residual Non-Fibrous Mastics/ V100 Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers B1.1B / 13024035-012 Black 100% Other None Detected 4-Inch Base Cove Over Residual Non-Fibrous Mastics/ V100 Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers B1.1C / 13024035-013 Black 100% Other None Detected 4-Inch Base Cove Over Residual Non-Fibrous Mastics/ V100 Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers M5.1A / 13024035-014 Various 100% Other None Detected 4-Inch Base Cove Over Residual Non-Fibrous Mastics/ V100 Homogeneous
13024035 SanAir ID Number
FINAL REPORT
Certification
Date: 10/15/2013 Date: 10/15/2013 Page 2 of 12
804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070
Web: http://www.sanair.com E-mail: iaq@sanair.com
Name:
Address:
CTA Construction & Environmental, LLC 219 2nd Ave South Great Falls, MT 59405
Project Number:
P.O. Number:
Project Name:
GF 13076
WVI-Bldg 1702
Collected Date:
Received Date:
Report Date:
Analyst:
10/4/2013
10/8/2013 10:00:00 AM
10/15/2013 4:35:50 PM
Childress, Susan
Asbestos Bulk PLM EPA 600/R-93/116 Stereoscopic Components Asbestos
SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers M5.1B / 13024035-015 Various 100% Other None Detected 4-Inch Base Cove Over Residual Non-Fibrous Mastics/ V100 Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers M5.1C / 13024035-016 Various 100% Other None Detected 4-Inch Base Cove Over Residual Non-Fibrous Mastics/ V100 Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers M6.1A / 13024035-017 Various 100% Other None Detected Flooring Mastics/ V100 Non-Fibrous
Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers M6.1B / 13024035-018 Various 100% Other None Detected Flooring Mastics/ V100 Non-Fibrous
Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers M6.1C / 13024035-019 Various 100% Other None Detected Flooring Mastics/ V100 Non-Fibrous
Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers S7.1A / 13024035-020 Beige 100% Other None Detected Pebble-Encased Skim Coating On Non-Fibrous Exterior Panels/ Exterior Fac Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers S7.1B / 13024035-021 Beige 100% Other None Detected Pebble-Encased Skim Coating On Non-Fibrous Exterior Panels/ Exterior Fac Homogeneous
13024035 SanAir ID Number
FINAL REPORT
Certification
Date: 10/15/2013 Date: 10/15/2013 Page 3 of 12
804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070
Web: http://www.sanair.com E-mail: iaq@sanair.com
Name:
Address:
CTA Construction & Environmental, LLC 219 2nd Ave South Great Falls, MT 59405
Project Number:
P.O. Number:
Project Name:
GF 13076
WVI-Bldg 1702
Collected Date:
Received Date:
Report Date:
Analyst:
10/4/2013
10/8/2013 10:00:00 AM
10/15/2013 4:35:50 PM
Childress, Susan
Asbestos Bulk PLM EPA 600/R-93/116 Stereoscopic Components Asbestos
SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers S7.1C / 13024035-022 Beige 100% Other None Detected Pebble-Encased Skim Coating On Non-Fibrous Exterior Panels/ Exterior Fac Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers X3.1A / 13024035-023 Tan 100% Other None Detected Exterior Panel Caulking/ Non-Fibrous Exterior Facad Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers X3.1B / 13024035-024 Tan 100% Other None Detected Exterior Panel Caulking/ Non-Fibrous Exterior Facad Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers X3.1C / 13024035-025 Tan 100% Other None Detected Exterior Panel Caulking/ Non-Fibrous Exterior Facad Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers X1.1A / 13024035-026 Grey 100% Other None Detected Concrete/ Exterior Foundation Non-Fibrous
Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers X1.1B / 13024035-027 Grey 100% Other None Detected Concrete/ Exterior Foundation Non-Fibrous
Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers X1.1C / 13024035-028 Grey 100% Other None Detected Concrete/ Exterior Sidewalk Non-Fibrous
Homogeneous
13024035 SanAir ID Number
FINAL REPORT
Certification
Date: 10/15/2013 Date: 10/15/2013 Page 4 of 12
804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070
Web: http://www.sanair.com E-mail: iaq@sanair.com
Name:
Address:
CTA Construction & Environmental, LLC 219 2nd Ave South Great Falls, MT 59405
Project Number:
P.O. Number:
Project Name:
GF 13076
WVI-Bldg 1702
Collected Date:
Received Date:
Report Date:
Analyst:
10/4/2013
10/8/2013 10:00:00 AM
10/15/2013 4:35:50 PM
Childress, Susan
Asbestos Bulk PLM EPA 600/R-93/116 Stereoscopic Components Asbestos
SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers X7.2A / 13024035-029 Black 2% Wollastonite 98% Other None Detected Foundation Sealant/ Exterior Non-Fibrous Foundation Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers X7.2B / 13024035-030 Black 2% Wollastonite 98% Other None Detected Foundation Sealant/ Exterior Non-Fibrous Foundation Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers X7.2C / 13024035-031 Black 2% Wollastonite 98% Other None Detected Foundation Sealant/ Exterior Non-Fibrous Foundation Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers R5.1A / 13024035-032 Brown 100% Other None Detected 2-Layered EPDMS, Roofing Non-Fibrous
Heterogeneous
R5.1A / 13024035-032 Brown 85% Cellulose 15% Other None Detected 2-Layered EPDMS, Insulation Fibrous
Heterogeneous
R5.1A / 13024035-032 Black 65% Cellulose 35% Other None Detected 2-Layered EPDMS, Felt Fibrous
Heterogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers R5.1B / 13024035-033 Brown 100% Other None Detected 2-Layered EPDMS, Roofing Non-Fibrous
Heterogeneous
R5.1B / 13024035-033 Brown 85% Cellulose 15% Other None Detected 2-Layered EPDMS, Insulation Fibrous
Heterogeneous
R5.1B / 13024035-033 Black 65% Cellulose 35% Other None Detected 2-Layered EPDMS, Felt Fibrous
Heterogeneous
13024035 SanAir ID Number
FINAL REPORT
Certification
Date: 10/15/2013 Date: 10/15/2013 Page 5 of 12
804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070
Web: http://www.sanair.com E-mail: iaq@sanair.com
Name:
Address:
CTA Construction & Environmental, LLC 219 2nd Ave South Great Falls, MT 59405
Project Number:
P.O. Number:
Project Name:
GF 13076
WVI-Bldg 1702
Collected Date:
Received Date:
Report Date:
Analyst:
10/4/2013
10/8/2013 10:00:00 AM
10/15/2013 4:35:50 PM
Childress, Susan
Asbestos Bulk PLM EPA 600/R-93/116 Stereoscopic Components Asbestos
SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers R5.1C / 13024035-034 Brown 100% Other None Detected 2-Layered EPDMS, Roofing Non-Fibrous
Heterogeneous
R5.1C / 13024035-034 Brown 85% Cellulose 15% Other None Detected 2-Layered EPDMS, Insulation Fibrous
Heterogeneous
R5.1C / 13024035-034 Black 65% Cellulose 35% Other None Detected 2-Layered EPDMS, Felt Fibrous
Heterogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers B1.2A / 13024035-035 Beige 100% Other None Detected 4-Inch Base Cove Over Mastic/ Non-Fibrous 100 Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers B1.2B / 13024035-036 Beige 100% Other None Detected 4-Inch Base Cove Over Mastic/ Non-Fibrous 101 Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers B1.2C / 13024035-037 Beige 100% Other None Detected 4-Inch Base Cove Over Mastic/ C1 Non-Fibrous
Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers M5.2A / 13024035-038 Cream 100% Other None Detected 4-Inch Base Cove Over Mastic/ Non-Fibrous 100 Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers M5.2B / 13024035-039 Cream 100% Other None Detected 4-Inch Base Cove Over Mastic/ Non-Fibrous 101 Homogeneous
13024035 SanAir ID Number
FINAL REPORT
Certification
Date: 10/15/2013 Date: 10/15/2013 Page 6 of 12
804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070
Web: http://www.sanair.com E-mail: iaq@sanair.com
Name:
Address:
CTA Construction & Environmental, LLC 219 2nd Ave South Great Falls, MT 59405
Project Number:
P.O. Number:
Project Name:
GF 13076
WVI-Bldg 1702
Collected Date:
Received Date:
Report Date:
Analyst:
10/4/2013
10/8/2013 10:00:00 AM
10/15/2013 4:35:50 PM
Childress, Susan
Asbestos Bulk PLM EPA 600/R-93/116 Stereoscopic Components Asbestos
SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers M5.2C / 13024035-040 Cream 100% Other None Detected 4-Inch Base Cove Over Mastic/ C1 Non-Fibrous
Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers M6.2A / 13024035-041 Various 100% Other None Detected Carpet Mastic Over Historic Non-Fibrous Mastic/ 102 Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers M6.2B / 13024035-042 Various 100% Other None Detected Carpet Mastic Over Historic Non-Fibrous Mastic/ 103 Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers M6.2C / 13024035-043 Various 100% Other None Detected Carpet Mastic Over Historic Non-Fibrous Mastic/ C1 Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers F2.1A / 13024035-044 Purple 100% Other None Detected Hued, 12x12-Inch Floor Tiles Non-Fibrous Over Light Mastic/ 101 Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers F2.1B / 13024035-045 Purple 100% Other None Detected Hued, 12x12-Inch Floor Tiles Non-Fibrous Over Light Mastic/ 101 Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers F2.1C / 13024035-046 Purple 100% Other None Detected Hued, 12x12-Inch Floor Tiles Non-Fibrous Over Light Mastic/ 101 Homogeneous
13024035 SanAir ID Number
FINAL REPORT
Certification
Date: 10/15/2013 Date: 10/15/2013 Page 7 of 12
804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070
Web: http://www.sanair.com E-mail: iaq@sanair.com
Name:
Address:
CTA Construction & Environmental, LLC 219 2nd Ave South Great Falls, MT 59405
Project Number:
P.O. Number:
Project Name:
GF 13076
WVI-Bldg 1702
Collected Date:
Received Date:
Report Date:
Analyst:
10/4/2013
10/8/2013 10:00:00 AM
10/15/2013 4:35:50 PM
Childress, Susan
Asbestos Bulk PLM EPA 600/R-93/116 Stereoscopic Components Asbestos
SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers M2.1A / 13024035-047 Yellow 3% Cellulose 97% Other None Detected Hued, 12x12-Inch Floor Tiles Non-Fibrous Over Light Mastic/ 101 Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers M2.1B / 13024035-048 Yellow 3% Cellulose 97% Other None Detected Hued, 12x12-Inch Floor Tiles Non-Fibrous Over Light Mastic/ 101 Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers M2.1C / 13024035-049 Yellow 3% Cellulose 97% Other None Detected Hued, 12x12-Inch Floor Tiles Non-Fibrous Over Light Mastic/ 101 Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers X7.1A / 13024035-050 Black 100% Other None Detected Sink Undercoating/ 105 Non-Fibrous
Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers X7.1B / 13024035-051 Black 100% Other None Detected Sink Undercoating/ 105 Non-Fibrous
Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers X7.1C / 13024035-052 Black 100% Other None Detected Sink Undercoating/ 105 Non-Fibrous
Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers F4.1A / 13024035-053 Off-White 30% Cellulose 60% Other None Detected Sheet Floor With Backing Over Non-Fibrous 10% Glass Mastic/ 106 Homogeneous
13024035 SanAir ID Number
FINAL REPORT
Certification
Date: 10/15/2013 Date: 10/15/2013 Page 8 of 12
804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070
Web: http://www.sanair.com E-mail: iaq@sanair.com
Name:
Address:
CTA Construction & Environmental, LLC 219 2nd Ave South Great Falls, MT 59405
Project Number:
P.O. Number:
Project Name:
GF 13076
WVI-Bldg 1702
Collected Date:
Received Date:
Report Date:
Analyst:
10/4/2013
10/8/2013 10:00:00 AM
10/15/2013 4:35:50 PM
Childress, Susan
Asbestos Bulk PLM EPA 600/R-93/116 Stereoscopic Components Asbestos
SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers F4.1B / 13024035-054 Off-White 30% Cellulose 60% Other None Detected Sheet Floor With Backing Over Non-Fibrous 10% Glass Mastic/ 10 Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers F4.1C / 13024035-055 Off-White 30% Cellulose 60% Other None Detected Sheet Floor With Backing Over Non-Fibrous 10% Glass Mastic/ 202 Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers M4.1A / 13024035-056 Tan 100% Other None Detected Sheet Floor With Backing Over Non-Fibrous Mastic/ 106 Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers M4.1B / 13024035-057 Tan 100% Other None Detected Sheet Floor With Backing Over Non-Fibrous Mastic/ 106 Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers M4.1C / 13024035-058 Tan 100% Other None Detected Sheet Floor With Backing Over Non-Fibrous Mastic/ 202 Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers B1.3A / 13024035-059 Brown 100% Other None Detected Base Cove Over Mastic/ 106A Non-Fibrous
Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers B1.3B / 13024035-060 Brown 100% Other None Detected Base Cove Over Mastic/ 106A Non-Fibrous
Homogeneous
13024035 SanAir ID Number
FINAL REPORT
Certification
Date: 10/15/2013 Date: 10/15/2013 Page 9 of 12
804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070
Web: http://www.sanair.com E-mail: iaq@sanair.com
Name:
Address:
CTA Construction & Environmental, LLC 219 2nd Ave South Great Falls, MT 59405
Project Number:
P.O. Number:
Project Name:
GF 13076
WVI-Bldg 1702
Collected Date:
Received Date:
Report Date:
Analyst:
10/4/2013
10/8/2013 10:00:00 AM
10/15/2013 4:35:50 PM
Childress, Susan
Asbestos Bulk PLM EPA 600/R-93/116 Stereoscopic Components Asbestos
SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers B1.3C / 13024035-061 Brown 100% Other None Detected Base Cove Over Mastic/ 106A Non-Fibrous
Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers M5.3A / 13024035-062 Brown 100% Other None Detected Base Cove Over Mastic/ 106A Non-Fibrous
Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers M5.3B / 13024035-063 Brown 100% Other None Detected Base Cove Over Mastic/ 106A Non-Fibrous
Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers M5.3C / 13024035-064 Brown 100% Other None Detected Base Cove Over Mastic/ 106A Non-Fibrous
Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers B1.4A / 13024035-065 White 100% Other None Detected 4-Inch Vinyl Base Cove/ 109 Non-Fibrous
Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers B1.4B / 13024035-066 White 100% Other None Detected 4-Inch Vinyl Base Cove/ 109 Non-Fibrous
Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers B1.4C / 13024035-067 White 100% Other None Detected 4-Inch Vinyl Base Cove/ 109 Non-Fibrous
Homogeneous
13024035 SanAir ID Number
FINAL REPORT
Certification
Date: 10/15/2013 Date: 10/15/2013 Page 10 of 12
804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070
Web: http://www.sanair.com E-mail: iaq@sanair.com
Name:
Address:
CTA Construction & Environmental, LLC 219 2nd Ave South Great Falls, MT 59405
Project Number:
P.O. Number:
Project Name:
GF 13076
WVI-Bldg 1702
Collected Date:
Received Date:
Report Date:
Analyst:
10/4/2013
10/8/2013 10:00:00 AM
10/15/2013 4:35:50 PM
Childress, Susan
Asbestos Bulk PLM EPA 600/R-93/116 Stereoscopic Components Asbestos
SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers H3.1A / 13024035-068 Grey 100% Other None Detected HVAC Seam Paste/ 202 Non-Fibrous
Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers H3.1B / 13024035-069 Grey 100% Other None Detected HVAC Seam Paste/ 202 Non-Fibrous
Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers H3.1C / 13024035-070 Grey 100% Other None Detected HVAC Seam Paste/ 202 Non-Fibrous
Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers F4.2A / 13024035-071 Grey 15% Cellulose 83% Other None Detected Hued S. Floor Tile/Mastics Non-Fibrous 2% Glass
Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers F4.2B / 13024035-072 Grey 15% Cellulose 83% Other None Detected Hued S. Floor Tile/Mastics Non-Fibrous 2% Glass
Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers F4.2C / 13024035-073 Grey 15% Cellulose 83% Other None Detected Hued S. Floor Tile/Mastics Non-Fibrous 2% Glass
Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers M4.2A / 13024035-074 Various < 1% Cellulose 100% Other None Detected Hued S. Floor Tile/Mastics Non-Fibrous
Homogeneous
13024035 SanAir ID Number
FINAL REPORT
Certification
Date: 10/15/2013 Date: 10/15/2013 Page 11 of 12
804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070
Web: http://www.sanair.com E-mail: iaq@sanair.com
Name:
Address:
CTA Construction & Environmental, LLC 219 2nd Ave South Great Falls, MT 59405
Project Number:
P.O. Number:
Project Name:
GF 13076
WVI-Bldg 1702
Collected Date:
Received Date:
Report Date:
Analyst:
10/4/2013
10/8/2013 10:00:00 AM
10/15/2013 4:35:50 PM
Childress, Susan
Asbestos Bulk PLM EPA 600/R-93/116 Stereoscopic Components Asbestos
SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers M4.2B / 13024035-075 Various < 1% Cellulose 100% Other None Detected Hued S. Floor Tile/Mastics Non-Fibrous
Homogeneous
Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers M4.2C / 13024035-076 Various < 1% Cellulose 100% Other None Detected Hued S. Floor Tile/Mastics Non-Fibrous
Homogeneous
13024035 SanAir ID Number
FINAL REPORT
Certification
Date: 10/15/2013 Date: 10/15/2013 Page 12 of 12
Disclaimer
The final report cannot be reproduced, except in full, without written authorization from SanAir.
Fibers smaller than 5 microns cannot be seen with this method due to scope limitations. The accuracy of the results is dependent upon the client’s sampling procedure and information provided to the laboratory by the client. SanAir assumes no responsibility for the sampling procedure and will provide evaluation reports based solely on the sample and information provided by the client. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government.
For NY state samples, method EPA 600/M4-82-020 is performed.
Polarized- light microscopy is not consistently reliable in detecting asbestos in floor covering and similar non-friable organically bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos containing.
NY ELAP lab ID 11983
| Appendix C - Data Summary Table.pdf |
| Table 1 - ACM |
File details come from the government source that posted it.