This document is a Salient Characteristics specification for a 750 kVA three-phase transformer, revised on 9 September 2025. The transformer has a 65-degree average winding rise and KNAN cooling class, with no specific insulating/cooling fluid requirement. It operates at 13200 Delta Volts on the high voltage side (15 kV class, 95 kV BIL) with a dead front primary termination and loop feed, featuring a 5-position tap changer with 2.5% taps above and below nominal. The low voltage side is 480Y/277 volts (1.2 kV class, 30 kV BIL) with a live front secondary termination and radial feed.
Key technical specifications include 200 amp bushing wells, 15-38kV load break switches, bayonet fuses for over-current protection, and a 20-inch-deep IEEE/ANSI cabinet in Munsell Green. The transformer is UL Listed, uses copper coils and windings, and includes features like a magnetic liquid level gauge, pressure/vacuum gauge, dial thermometer, drain and fill valves, and two-hole ground pads. Additional components include load break inserts, removable studs, and a cabinet door pocket for spare fuses. The transformer is designed to meet DOE 2016 efficiency standards and has a k 4.5 loop feed configuration per IEEE specifications.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SALIENT CHARACTERISTICS
FOR
750 kVA Transformers
Revised:
9 September 2025
1523970069A Highlight
Detail Description kVA 750kVA 3 Phase Temp Rise 65-degree average winding rise Cooling Class KNAN Insulating/Cooling Fluid Fluid; No specific requirement Efficiency Standard DOE 2016 High Voltage 13200 Delta Volts High Voltage kV Class 15 kV Class High Voltage kV BIL 95 kV BIL Primary Termination Style Dead Front Primary Feed Type Loop Feed Taps 2ea 2.5% Taps above and 2EA 2.5% Taps below nominal Tap Changer 5-position tap changer Tap Changer Switch Location Front Plate HV Compartment High Voltage Bushings 200 Amp bushing wells with removeable studs (6ea) High Voltage Inserts 15kV, 95kV BIL load break inserts (6ea) Load Break Switch(es) 15-38kV, 300 Amp, 2 position (3ea) Load Break Switch Location Front Plate HV Compartment Switch Cover Padlock provision on switch handle (inside HV compartment) Arresters None Over Current Protection Bayonet fuses in series with partial-range current limiting fuses (3ea) Expulsion fuses bayonet fuses(3a) Bayonet Holder bayonet fuse holder (3ea) Spare Expulsion Fuses bayonet fuses(3a) Low Voltage 480Y/277 Low Voltage kV Class 1.2 kV Class Low Voltage kV BIL 30 kV BIL Secondary Termination Style Live front Secondary Feed Radial Feed Low Voltage Bushing Location LV front Plate Low Voltage Bushings 1" copper stud with 12-hole screw on spade bushings (4ea) Bushing supports Standard LV bushing support assembly Cabinet 20-inch-deep cabinet Cabinet hardware Penta-head cabinet door bolts Cabinet Types IEEE/ANSI Infrared Viewing Window Not required Cabinet accessories pocket on compartment door for spare fuses Bushing layout k 4.5 Loop feed per IEEE Coatings Munsell Green - Munsell 7GY 3.29/1.5 FM/UL certifications UL Listed Liquid Level Gauge Magnetic Liquid level gauge Pressure Vacuum gauges Pressure/Vacuum gauge Thermometer Dial Type Drain Valve Drain Valve with sampler in LV compartment Fill Valve Fill Plug in LV compartment Pressure Relief Device 50 SCFM Gound Pads two-hole ground pads (3ea) Coil Material Copper Winding Material Copper
1523970069A Highlight
1523970069A Highlight