This document contains the Salient Characteristics for SERE Escape Sheds required by the Department of the Air Force Air Mobility Command for SERE training at Fairchild AFB. The objectives are to create a modern training facility to teach Tactics, Techniques, and Procedures (TTPs) for combating the threat of modern holding facilities in the Urban/Captive Environment. The required Escape Sheds must meet specifications for size, construction, door/window requirements, lighting, ventilation, and transportability via forklift. This information is provided in support of Solicitation Number FA462024QA930 for the procurement of these SERE "Escape" sheds.

View the file

Other files

File Type Posted
Amendment 0001 SF-30 SERE Escape Sheds.pdf PDF
Attach 1 Salient Characteristics.pdf PDF
24QA930 Combo.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SALIENT CHARACTERISTICS

FOR

SERE Escape Sheds

June 6, 2024

Salient Characteristics For

SERE Escape Sheds

Fairchild AFB, WA

1. BACKGROUND: Current ‘Escape” training is becoming increasingly challenged by advanced capabilities and modern holding facilities of our ‘Peers’. To adequately train our aircrew and airmen, we are encouraged and required by DODI 5000.92, newly updated USAF course training standards, and AETC Instructor Guidance to update and innovate our training capability.

2. OBJECTIVES: To create a modern-day training facility able to facilitate the teaching, studying, and research Tactics, Techniques, and Procedures (TTPs) capable of combatting the ‘Peer Threat’ of modern holding facilities in the Urban/Captive Environment and the USAF increased training standards.

3. REQUIREMENTS:

Escape Sheds: These sheds are required to house and facilitate the training through practical exercises both ‘in’ and ‘out’ of training scenarios. Each shed must meet the following requirements:

a) Shed must be between 8’ x 8’ to 9’ x 9’ in dimensions. No taller than 12’.

b) Shed must be outdoor variety with waterproof roofing. Roof may be flat or angled.

c) Sheds must be transportable via forklift.

d) Exterior door must be between 30”-32” x 76”-80” in size. Must have a metal frame and metal hinges. Must have 2 locks, one a 5-pin pin-tumbler style keyed doorknob lock and other must have 5-pin pin-tumbler style dead bolt lock.

e) Must have two windows on different facing walls. They must be horizontal slide two pane glass or see through plastic. Size must be between 3’-4’wide by 3’-4’ tall.

f) Must have a flat ceiling covered with drywall or equivalent and have a small attic space at least 2’ in height at tallest point.

g) Must have basement crawl space minimum 6”.

h) Must have internal lighting with minimum of two functioning light fixtures that are able to be plugged in to external power source with standard 110v cord. No outlets in the shed are required.

i) Concept of design is a wood structure.

j) Must have 2 or more vents in the attic space to reduce heat.

k) Ceiling must be separated from attic with a removable material (Wood, dry wall...)