COMBINED SYNOPSIS/SOLICITATION

FA4620-16-T-A321

AMENDMENT 0002

WOOD SHOP CNC ROUTER

FAIRCHILD AFB

22 SEP 2016

This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice.

The purpose of this amendment is to answer questions posed by vendors.

Solicitation FA4620-16-T-A321 for CNC Router with 5’x10’ Vacuum Table and installation of 208v three phase outlet at Fairchild AFB. The project will require the delivery and setup of a CNC Router with 5’x10’ vacuum table and installation of a 208v three phase outlet in room 215 on the southwest side for the Fairchild AFB Wood Shop is hereby issued as a Request for Quotation (RFQ).

ITEM

NO

SUPPLIES/

SERVICES

QUANTITY UNIT UNIT PRICE AMOUNT

0002 1 Lot Install 208v Three-Phase Outlet

FFP

Contractor is to install one (1) 208v, three-phase electrical outlet on the southwest wall of room 215 in the Wood Shop, BLDG 2447B, connected to the service equipment located in room 214A, approximately 160’ away.

FOB: Destination

SIGNAL CODE: A

NET AMT

QUESTIONS AND ANSWERS

Question 1 Is the panel box capable of providing the 60 amps required for our product?

Answer 1 Yes, the main mechanical room switch gear room located in room 214A is capable of handling 60 amps. There are currently no 60 amp breakers in the main mechanical room. The amperage required for the provided machinery needs to have an amperage equivelant breaker box included and installed. The run from the switch gear is approximately 160’ to the outlet location.

SALIENT CHARACTERISTICS

WOOD SHOP CNC ROUTER

1. This requirement is for a Large 5’x10’ vacuum table CNC router for the 92d Force Support

Squadron (FSS) Wood Shop. Contractor shall provide one (1) large vacuum table CNC router with setup that meets the characteristics stated below, and install one (1) 208v three-phase electrical outlet.

2. The provided item shall meet or exceed the follow requirements:

- Spindle is to be used for woodworking.

- 60" x 120" x 6" axis travel.

- 900 in/min maximum rapid travel.

- 900 in/min maximum cutting speed.

- Min 7" clearance under gantry.

- Heavy-duty welded tubular steel frame.

- Vacuum table with T-slots.

- Gantry is driven on each end (two “helical” rack-and-pinion drives on “Y” axis).

- Variable frequency drive.

- Min 6 HP constant torque, high frequency liquid-cooled spindle (3,000 - 24,000 rpm)

- Hand Held controller

- Solid state limit switches.

- Manual Tool Change

- Capable of functioning with a 208v three-phase system

- Installation and training/ standard not proprietery software

- Compatible with the following software:

- Microsoft Windows based operating system

- Vcarve 8.0 and higher editions

- Aspire 8.0 or higher

- Cut 3D 1.110 or higher

- PhotCarve 1.102 or higher

-Tools to be provided: All bits shall be ½” shank bits with carbide blades/edges -(1) 90 degree V bit -(1) 60 degree V bit -(1) ball nose bit -(1) taper ball nose bit -(1) 1/8” flat tip spiral upcut bit -(1) ¼” flat tip spiral upcut bit -(1) ½” flat tip spiral upcut bit -(1) bottom clearing/spoilboard upshear design

Standard features should include:

Spindle speed control through programming.

Centralized lubrication system for all axes.

10 HP Vacuum Pump Included 10 HP Vacuum Accessories

3. Contractor is to install one (1) 208v, three-phase electrical outlet on the southwest wall of room

215 in the Wood Shop, BLDG 2447B. The outlet will require conduit ran from the main mechanical room located in room 214A to the outlet location. The conduit will require surface mounting to the interior of the building with approximately 160’ of conduit. An appropriate sized breaker box will be required to be installed to match the provided products amperage requirements.