19-1043B_Site_Visit_Minutes.pdf
PDF 145 KB Posted
- Attached to
- 19-1043B, Replace Door with Automatic Door, Bldg. 6670 Federal contract opportunity
- Solicitation number
- FA4610-19-R-A041
About this file
Site visit Minutes
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 19-1043B_RFI_Response.pdf | ||
| 19-1043B_SV_Sign_In.pdf | ||
| Atch_1_SOW_20190812.pdf | ||
| Solicitation_Amendment_FA461019RA0410001_SF_30.pdf | ||
| Atch_5_QC_Plan_01_45_00.pdf | ||
| FA461019RA041_19-1043B_Solicitation.pdf | ||
| Atch_2_Door_Photos.pdf | ||
| Atch_3_General_Requirements_01_00_00.pdf | ||
| Atch_6_Environmental_01_57_20.pdf | ||
| Atch_4_Submittal_Procedures_01_33_00.pdf | ||
| Atch_1_SOW_20190620.pdf |
Show all 11
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DEPARTMENT OF THE AIR FORCE
30TH SPACE WING (AFSPC)
GUARDIANS OF THE HIGH FRONTIER
20 Aug 2019
MEMORANDUM FOR RECORD
SOLICITATION NUMBER: FA4610-19-R-A041
SUBJECT: XUMU 19-1043B, Replace Door with Automatic Door, Bldg. 6670
1. On 8 Aug 2019, Mr. Rolando Quizon from Civil Engineering requested a Site Validation Visit.
A Site Validation Visit was scheduled for 20 Aug 2019 at 9:30 AM PDT.
2. A Site Validation Visit was conducted on 20 Aug 2019 for titled project. The following representatives were in attendance:
Name/Rank Squadron/Office Symbol/Company/Organization
Email Address
Rolando Quizon 30 CES/CENMP rolando.quison@us.af.mil Willie Nadal 30 CES/CENMP wilfredo.nadal@us.af.mil Ainsley Allen AFPET ainsley.allen.3@us.af.mil Alyson Kolding 30 CONS/PKA alyson.kolding@us.af.mil Jose Rodriguez Specialty Construction Services jose@specialtyconstruction.net Mateo Perez Ruprecht Construction mateo@ruprechtconstruction.com
a. During the Site Validation Visit, the following items were discussed:
i) The door should open automatically using either a motion sensor or a wall push putton.
ii) The buttons/sensor must be on both sides of the door.
iii) No center divider.
iv) Small windows on both door panels conforming to the required specifications.
v) The panic bar does not need to be automatic, must have a manual method of operating.
vi) A power source is available in the hallway.
vii) Finishings/colors shall match required base specifications.
3. Please submit all questions in the form of Requests for Information (RFI) no later than 22 Aug 2019, 2:00PM PDT. Information discussed at the site visit is not confirmed unless it has been addressed formally in response to RFIs.
ALYSON KOLDING
Contract Specialist
Attachment:
1. Site Visit Sign-In Sheet
| 2019-08-20T11:42:41-0700 | |
| KOLDING.ALYSON.R.1525848902 |