Text version
SW
CCW
TGB
AUGUST 2012
AWUB-09-0176
ADD/ALTER
RECREATION VEHICLE (RV)
STORAGE LOT
MANUAL DOUBLE VEHICLE GATE
Post Cap (Typical)
NOTE:
All Gate Frames to be Welded at all pipe intersections.
Plunger Rod (Typical)
Catch Block (Typical)
Industrial Fork and Guide Assembly (Typical)
1. The fence installation and details are typical and may vary in accordance with different manufactures, provided that they meet the standard specifications.
2. Typical installation plan may vary as shown on the plans or as directed by Engineer. Location of gates to be shown on plans.
3. All connection methods to be approved by Project Engineer.
4. For gates widths - Single Gates = 13' Width Maximum.
Double Gates = 16' Width Maximum.
N O T E S
Plunger Rod Keeper
5. Gate Hinges to be tack welded to gate post and frames to prevent vandalism of gates.
See Isometric A
ISOMETRIC A
6. No more than one splice per panel (See Specifications for more
7. See Technical Specifications for Information regarding Fence Fasteners for this Sheet.
8. All Corner and Gate Post shall have 39" Deep by 12" Diameter Concrete Foundation. All Line Post shall have 33" Deep by 9" Diameter Concrete Foundation.
1" Minimum clearance
5"
12"
712"
16' - 0" Maximum
All Corner and Gate Posts to be a minimum of Schedule 40, 4" Ø Galvanized Steel Post.
7'-6" (typical)
2 3/8" Fence Post
LINE POST
4" Fence Post
GATE & CORNER POST
FOUNDATION DETAIL FOUNDATION DETAIL
OUTSIDE
DIA.
(INCHES)
POUNDS
PER
LIN. FT.
LINE
POST
CORNER
POST
2 3/8"
4" 9.10
3.65
T A B L E
GATE AND
FRAME
1 7/8" 2.71
GATE
1" x 6" x 6' Cedar Pickets #1 Western Red Cedar - Rough - Sawn Pickets are to be nailed to rails using 6d aluminum nails with screw shanks.
Galvanized Bolts post clamps (d-238-h) with 2-1/4" x 1" galvanized carriage
2" x 4" Cedar or Pressure Treated wooden rails
SIDE VIEW
Undisturbed soil shall be bolted to posts w/2-3/8" pipe to wood bolts and 4-1/4" x 1-1/2" lag screws for 2-3/8" Line Post
Pipe to wood post clamps (d-238)
Pipe to wood post clamps (d-238)
5/16" x 6" w/washer & nut for 4" Gate or Corner Post.
information).
N.T.S.
N.T.S.
N.T.S.
N.T.S.
N.T.S.
ELECTRICAL DOUBLE VEHICLE GATE
N.T.S.
Earth ground stake
Linear model SWD-211 gate operator or equivilant
Gate arm
24-7/8"
Top of gate plate 24-7/8" above the top of the pad
POWER SUPPLY CONDUIT
(SEE ELECTRIC SITE PLAN)
Master gate operator
FREE EXIT LOOP *
Slave gate operator
OBSTRUCTION LOOP
OBSTRUCTION LOOP
PIPE BOLLARDS SEE DETAILS
CARD READER SEE DETAILS
CENTERLINE OF PIPE AND
FRONT OF CARD FACE READER
4 PAIR #14 SHIELDED IN 1 1/2"
PVC CONDUIT BELOW GRADE
ELECTRICAL GATE PLAN
N.T.S.
1/2" SCHEDULE 40
OR 80 PVC (TYP.)
PLOT AT 1 to 1
Black Full
REFERENCED STANDARD:
STATE OF LOUISIANA DEPARTMENT OF TRANSPORTATION
AND DEVELOPMENT - STANDARD SPECIFICATIONS FOR
ROADS AND BRIDGES - 2006 EDITION.
DETAILS
FENCE AND GATE