SGER 17-0100 Combined Drawings

View the file

Other files for this federal contract opportunity

Other files attached to Repair Golf Course HVAC, newest first.
File Type Posted
OF_1419_-_Abstract_of_Offers_Combined.pdf PDF
FA4600-18-R-0015-0001.pdf PDF
Attch_1_-_Wage_Determinations.pdf PDF
FA4600-18-R-0015.pdf PDF
Attch_3_-_SGER_17_0100_Project_Manual_AREA_4_B9950.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1-800-331-5666

CALL BEFORE YOU DIG

EXISTING 6" PVC WATER MAIN

EXISTING 6" X 4" TEE WITH VALVE

(ASSUMED LOCATION OF EXISTING

WATER SERVICE LINE)

COORDINATE INSTALLATION OF

FIRE SERVICE LINE WITH

METROPOLITAN UTILITIES DISTRICT

INSTALL 310 LF OF 4" FIRE SERVICE

CONNECTION. PROVIDE AND INSTALL

FITTINGS AS NECESSARY. CONTRACTOR

CAN REDUCE THE FIRE SPRINKLER

SERVICE MAIN AS ALLOWED BY

AVAILABLE FLOW AND PRESSURE.

INSTALL POST INDICATOR VALVE

NOTE:

VALVE LOCATION SHALL MEET ALL LOCAL AND STATE

REQUIREMENTS. CONTRACTOR SHALL VERIFY LOCATION

WITH BUILDING INSPECTOR AND STATE FIRE MARSHAL

PRIOR TO INSTALLATION.

POST INDICATOR VALVE DETAIL

EXISTING END OF MAIN

HYDRANT

4" FIRE SERVICE, SEE

MECHANICAL PLAN FOR

CONTINUATION

REMOVE AND REPLACE

ASPHALT CART PATH AS

NECESSARY TO INSTALL FIRE

SERVICE CONNECTION AND

MECHANICAL ENCLOSURE.

FULL DEPTH SAWCUT REQUIRED

FOR ALL REMOVALS.

PROVIDE AND INSTALL 90 DEG

BEND

PROVIDE AND INSTALL 45 DEG

BEND

INSTALL 4" TEE, 4" VALVE AND 4"

X 3" REDUCER. CONNECT TO

EXISTING WATER SERVICE LINE

WIDEN CART PATH WITH 6" ASPHALT

PAVING TO PROVIDE 10' CLEARANCE

BETWEEN EDGE OF MECHANICAL

ENCLOSURE AND EDGE OF PAVED

SURFACE. FULL DEPTH SAWCUT

REQUIRED FOR ALL REMOVALS.

PROVIDE GRADING, SPRINKLER

RELOCATION, LANDSCAPE

RELOCATION AS NECESSARY TO

ACCOMMODATE CART PATH

WIDENING.

SEE MECHANICAL PLANS FOR

EQUIPMENT ENCLOSURE

DO NOT DISTURB EXISTING

UTILITY MANHOLES

REMOVE AND RECONSTRUCT

MODULAR BLOCK RETAINING WALL TO

ACCOMMODATE CART PATH

WIDENING. TRANSPLANT OR REPLACE

PLANTINGS.

CWPA#15112

DK

AP

8 OCT., 2015

DK

T

TRUE

NORTH

NSNS

H

TRUE

NORTH

NO SCALE

DUCT FITTINGS DETAIL

NO SCALE

WATER COIL DETAIL

NO SCALE

CONDENSATE DRAIN DETAIL

NO SCALE

AIR HANDLING UNIT DETAIL

NO SCALE

A

GRADE MOUNTED ROOFTOP UNIT DETAIL

NO SCALE

B

DIFFUSER CONNECTION DETAILS

B9950 SHEET 1 CC00-24X36
B9950 SHEET 2 C1.1 FIRE SERVICE CONNECTION SEALED_10-08-2015
B9950 SHEET 3 D10-24X36
B9950 SHEET 4 A11-24X36
B9950 Sheet 5 FP1.1
B9950 Sheet 6 FP1.2
B9950 Sheet 7 MD1.1
B9950 Sheet 8 MD1.2
B9950 Sheet 9 MD2.1
B9950 Sheet 10 M1.1
B9950 Sheet 11 M1.2
B9950 Sheet 12 M2.1
B9950 Sheet 13 M3.1
B9950 Sheet 14 M4.1
B9950 Sheet 15 ED1.1
B9950 Sheet 16 E1.1
B9950 Sheet 17 E2.1
B9950 Sheet 18 E3.1