Attch_2_-_SGER_17-0100_Combined_Drawings.pdf
PDF 14 MB Posted
- Attached to
- Repair Golf Course HVAC Federal contract opportunity
- Solicitation number
- FA4600-18-R-0015
About this file
SGER 17-0100 Combined Drawings
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| OF_1419_-_Abstract_of_Offers_Combined.pdf | ||
| FA4600-18-R-0015-0001.pdf | ||
| Attch_1_-_Wage_Determinations.pdf | ||
| FA4600-18-R-0015.pdf | ||
| Attch_3_-_SGER_17_0100_Project_Manual_AREA_4_B9950.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1-800-331-5666
CALL BEFORE YOU DIG
EXISTING 6" PVC WATER MAIN
EXISTING 6" X 4" TEE WITH VALVE
(ASSUMED LOCATION OF EXISTING
WATER SERVICE LINE)
COORDINATE INSTALLATION OF
FIRE SERVICE LINE WITH
METROPOLITAN UTILITIES DISTRICT
INSTALL 310 LF OF 4" FIRE SERVICE
CONNECTION. PROVIDE AND INSTALL
FITTINGS AS NECESSARY. CONTRACTOR
CAN REDUCE THE FIRE SPRINKLER
SERVICE MAIN AS ALLOWED BY
AVAILABLE FLOW AND PRESSURE.
INSTALL POST INDICATOR VALVE
NOTE:
VALVE LOCATION SHALL MEET ALL LOCAL AND STATE
REQUIREMENTS. CONTRACTOR SHALL VERIFY LOCATION
WITH BUILDING INSPECTOR AND STATE FIRE MARSHAL
PRIOR TO INSTALLATION.
POST INDICATOR VALVE DETAIL
EXISTING END OF MAIN
HYDRANT
4" FIRE SERVICE, SEE
MECHANICAL PLAN FOR
CONTINUATION
REMOVE AND REPLACE
ASPHALT CART PATH AS
NECESSARY TO INSTALL FIRE
SERVICE CONNECTION AND
MECHANICAL ENCLOSURE.
FULL DEPTH SAWCUT REQUIRED
FOR ALL REMOVALS.
PROVIDE AND INSTALL 90 DEG
BEND
PROVIDE AND INSTALL 45 DEG
BEND
INSTALL 4" TEE, 4" VALVE AND 4"
X 3" REDUCER. CONNECT TO
EXISTING WATER SERVICE LINE
WIDEN CART PATH WITH 6" ASPHALT
PAVING TO PROVIDE 10' CLEARANCE
BETWEEN EDGE OF MECHANICAL
ENCLOSURE AND EDGE OF PAVED
SURFACE. FULL DEPTH SAWCUT
REQUIRED FOR ALL REMOVALS.
PROVIDE GRADING, SPRINKLER
RELOCATION, LANDSCAPE
RELOCATION AS NECESSARY TO
ACCOMMODATE CART PATH
WIDENING.
SEE MECHANICAL PLANS FOR
EQUIPMENT ENCLOSURE
DO NOT DISTURB EXISTING
UTILITY MANHOLES
REMOVE AND RECONSTRUCT
MODULAR BLOCK RETAINING WALL TO
ACCOMMODATE CART PATH
WIDENING. TRANSPLANT OR REPLACE
PLANTINGS.
CWPA#15112
DK
AP
8 OCT., 2015
DK
T
TRUE
NORTH
NSNS
H
TRUE
NORTH
NO SCALE
DUCT FITTINGS DETAIL
NO SCALE
WATER COIL DETAIL
NO SCALE
CONDENSATE DRAIN DETAIL
NO SCALE
AIR HANDLING UNIT DETAIL
NO SCALE
A
GRADE MOUNTED ROOFTOP UNIT DETAIL
NO SCALE
B
DIFFUSER CONNECTION DETAILS
| B9950 SHEET 1 CC00-24X36 |
| B9950 SHEET 2 C1.1 FIRE SERVICE CONNECTION SEALED_10-08-2015 |
| B9950 SHEET 3 D10-24X36 |
| B9950 SHEET 4 A11-24X36 |
| B9950 Sheet 5 FP1.1 |
| B9950 Sheet 6 FP1.2 |
| B9950 Sheet 7 MD1.1 |
| B9950 Sheet 8 MD1.2 |
| B9950 Sheet 9 MD2.1 |
| B9950 Sheet 10 M1.1 |
| B9950 Sheet 11 M1.2 |
| B9950 Sheet 12 M2.1 |
| B9950 Sheet 13 M3.1 |
| B9950 Sheet 14 M4.1 |
| B9950 Sheet 15 ED1.1 |
| B9950 Sheet 16 E1.1 |
| B9950 Sheet 17 E2.1 |
| B9950 Sheet 18 E3.1 |
File details come from the government source that posted it.