Attachment_2_-_PRP_Furniture_Location_Sketch.pptx
PPTX presentation 49 KB Posted
- Attached to
- PRP Workstations & Modular Walls Federal contract opportunity
- Solicitation number
- FA4528-19-Q-CB02
About this file
Attachment 2 - PRP Furniture Location Sketch
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Attachment_1_-_Performance_Work_Statement_(PWS).docx | DOCX document | |
| CLS_Combined_Synopsis_and_Solicitation.pdf | ||
| Attachment_3_-_PRP_Security_Furniture_Drawings.pdf | ||
| Attachment_4_-_Quote_Sheet.xls | XLS spreadsheet | |
| Attachment_5_Mandatory_Clauses_and_Provisions.xlsx | XLSX spreadsheet |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
17 ½’ 9 ½’
Styles = District Enclosed 09, 10 Leverage with District Enclosed 02 Upstage 14 14 ½’ This door will be blocked, so space can be utilized Coffee Bar
Frosted Glass Wall Wardrobe Conference Table
Wardrobe
Barn Door Filing System w/ Mailing System /Printer
Coffee bar/microwave counter should tall and long enough to hold a full size countertop convection microwave, a coffee maker, a tea pot, with plenty of room to prepare food/drinks. It should also have drawer for silverware and cabinets for supplies.
Coffee Bar/Microwave Counter
Need this space To be at least 43” Cabinet depth must Be at least 21”
Filing System w/ Mailing System / Printer Mail/sorting slots Filing System/Mailing System/Printer should have lowers that are a combo of deep filing drawers that hold 9 x 12 document holders and be flanked by tall cabinets with shelves for supplies.
Shelves Cabinets
14’11’ 24’ 13’
14’11”
Frosted Glass Wall
District Enclosed 09, 10 Leverage with District Enclosed 02 Upstage 14
Barn Door
22 ½’ 10 ½’
Journal 02 District Private 01, 02, 09, 12 Expansion Casegoods Private 07, 08, 15 Expansion Desking Private 01
7” Deep x 1’ 6” Wide Ducting Wall Which is 2’10 ½” from left wall and 6’ from right wall.
9’4” 9’3” 2 Wardrobe Systems /Printer/TV Stand w/ shelving
Need this space To be at least 60+” to fit Television Cabinet depth must Be at least 21” Two Wardrobe / Printer / TV Stand Wardrobe/ Printer / TV Stand should have lowers that are a combo of deep filing drawers that hold 9 x 12 document holders and be flanked by tall cabinets with shelves for supplies.
Closet
Glass Modular Wall Old Wall to be removed
Filing System w/ Mailing System /Printer
Wardrobe System (Fitting 4-6)
22 ½’ 2 Wardrobe Systems /Printer/TV Stand w/ shelving 6’ 18’
Coffee Bar
10 ½ ‘
The offices need to be built using full privacy walls that extend to the ceiling (frosted glass), due to private and personal discussions with unit personnel.
Slide 1 and 4 show a total of 4 desks (all the same size) that eventually will be used to build an office space (by combining offices shown on slide 1 and 4) as shown on Slide 7.
Desk sizes would need to work in both spaces (possible 6’ x 7’+ desks allowing for 3’ walkway on each side and glass walls). Workstations need to have the capability to house one full time worker and one guest at any given time.
Would like frosted glass doors on any and all cabinets that come with this option. Need attached task lighting to all desk systems. Desks should also be a stand-up to sit-down conversion type where ever allowed in design.
Need pop-up charging systems and plugs. Anything attached is allowed, so add all the bells and whistles as long as they’re attached, so all bells and whistles. Should have CPU and Battery Back Up holders on all desks.