Questions and Answers - Crash Net.pdf
PDF 72 KB Posted
- Attached to
- Secondary Crash Net (SCN) Console
- Solicitation number
- FA446025Q0046
About this file
This document is a Questions file addressing two specific line items in a potential contract or procurement. The first question concerns line number 0003 for a Rack Mount UPS, with a clarification that the requirement is for a 1500-watt uninterruptible power supply. The second question pertains to line item number 0006 for a Fiber Switch, where the inquiry seeks confirmation about the acceptability of a switch with 10 SFP ports and 1 network port. The response indicates a preference to maintain the current specification of 3 units of part number 911-830-003.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Questions
- First, regarding line number 0003: Rack Mount UPS: How many Watts are you looking for in this UPS?
o 1500 watts
- Second, regarding line item number 0006: Fiber Switch: What exactly are you looking for? Is 10 SFP Ports w/ 1 Network Port sufficient?
o We are looking to stay with the qty 3 of part number 911-830-003.