Appendix B UNICOR 26782181A FURNITURE PLAN.pdf

PDF 2 MB Posted

Attached to
FA445226R0017_43d Air Mobility Operations Group_Building 720 Electrical
Solicitation number
FA445226R0017
Issued by

About this file

This is a furniture floor plan and design drawing for a federal office space at Pope Air Force Base (PAFF), NC prepared by UNICOR. The project covers approximately 49 cost per square foot and includes the design and installation of modular office furniture across multiple functional areas: Command and Control (CC) and Sales Executive (SEL) offices, a conference room, training and operations area, and a tactics workspace. The document indicates that certain areas fall outside UNICOR's scope of work and are marked as "to be determined."

Each of the 34 workstations specified in the design will be equipped with an electric height-adjustable sit/stand desk, dual monitor arm, desktop power module, tackboard, and task light. The floor plan details electrical infrastructure requirements including multiple basefeeds (power distribution points) with varying circuit counts ranging from 2 to 5 circuits per basefeed that require hardwiring by a customer-provided certified electrician to the building source. Panel heights vary throughout the design, with overhead cabinet supporting panels at 66 inches tall, standard panels at 54 inches tall, and a 42-inch tall reception counter. The customer is responsible for verifying existing building features including walls, columns, windows, doors, thermostats, HVAC systems, switches, and alarms to ensure proper furniture fit and for coordinating with telephone, computer, and electrical installers prior to installation. All drawings and price quotes are designated as proprietary UNICOR/OEI information until purchase by the intended government agency.

View the file

Other files

Show all 16

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SIDE A&B

C6

(1) 3'6"

SIDE A&B

C9

(94) 4'6"

SIDE A&B

C10

(22) 5'6"

SIDE A

C11

(24)

5'6"

SIDE B SIDE A

C12

(13)

4'6"

SIDE B

STORM

H:3'0"

STORM

H:4'0"

STORM

H:5'0"

OPEN

H:2'0"

STORM

H:3'0"

OPEN

H:2'0"

STORM

H:3'0"

OPEN

H:2'0"

STORM

H:2'0"

OPEN

H:2'0"

STORM

H:2'0"

15 18

3'

-8

TY

P

TA

C

TI

C S, 0"

TY

P

TA

C

TI

C S, 0"

3' -1" 5'

-1 0"

TY

P

AL

L

D O

/A D

O

7' -0

TYP 4 TACTICS 6' -0"

TYP ALL DO/ADO, 6' -0"

TYP 15, 6' -6"

JUST THIS 1, 5' -0"

TY

P

6' -6

TYP 3 TACTICS, 5' -6"

1' -6

8' -0"

6' -6

1/1

DIS5

*SIGNATURE BELOW DENOTES CUSTOMER'S

ACKNOWLEDGEMENT THAT THE DESIGN HAS

EXPLAINED THE DRAWINGS, AND THAT THE

CUSTOMER FULLY UNDERSTANDS ALL FURNITURE

COMPONENTS RELATIVE TO HEIGHTS, WIDTHS, AND

COLOR SELECTIONS SPECIFIED ETC...

*SIGNATURE BELOW DENOTES FULL

COMPREHENSION OF ELECTRICAL SPECIFICATIONS

NEEDED FOR POWER AND DATA INFEED

LOCATIONS AS REPRESENTED ON THE DRAWINGS.

*SIGNATURE BELOW DENOTES CUSTOMER HAS

VERIFIED THAT ALL FURNITURE AND/OR EXISTING

WINDOWS, COLUMNSM THERMOSTATS, HVAC,

SWITCHES, AND ALARMS HAVE BEEN ACCOUNTED

FOR ON THE DRAWINGS. ANY LOCATION CHANGES

OF THESE ITEMS THAT HAVE AN EFFECT ON THE

FURNITURE LAYOUT ARE THE SOLE RESPONSIBLITY

OF THE CUSTOMER.

DATE:

SIGNATURE:

FLOOR PLAN

BYNO.

26782181A.cmdrw

DRAWING REVIEW

02/18/2026

SWA

2:23:47 PM

DIS4

IT IS THE CUSTOMER'S RESPONSIBILITY TO HAVE

THEIR TELEPHONE AND COMPUTER INTSTALLERS,

AND THEIR ELECTRICIANS REVIEW THE FURNITURE

AND ELECTRICAL PLANS PRIOR TO THE ACTUAL

FURNITURE INSTALLATION TO DETERMINE THE

EXTENT OF RE-WIRING THAT WILL BE REQUIRED. A

CERTIFIED ELECTRICIAN MUST MAKE THE

HARD-WIRE CONNECTION FROM THE TOP/BASE

FEED TO THE BUILDING SOURCE.

DIS8

NOTES:

1. (#) INDICIATES WORKSTATION (WS) NUMBER.

2. EACH WORKSTATION GETS AN ELECTRIC HEIGHT-ADJUSTABLE (SIT/STAND) DESK, DUAL MONITOR

ARM, DESKTOP POWER MODULE, TACKBOARD & TASKLIGHT.

3. CUSTOMER-PROVIDED ELECTRICIAN WILL HARDWIRE UNICOR-SUPPLIED POWER INFEEDS

("BASEFEED") TO BUILDING WHERE SHOWN ON FURNITURE PLAN. BASEFEEDS GET HARDWIRED TO BUILDING WALL. QUANTITY OF CIRCUITS THAT ELECTRICIAN WILL NEED TO HARDWIRE PER BASEFEED IS

NOTED IN PARENTHESIS.

4. BOTTOM-OPEN PANELS PROVIDED ALONG BUILDING WALLS TO PROVIDE EASIER ACCESS TO THE NEW

BASEFEEDS & EXISTING BUILIDNG WALL OUTLETS.

5. OVERHEAD CABINET SUPPORTING PANELS ARE 66" TALL. ALL OTHER PANELS (EXCEPT FOR 42" TALL

RECEPTION COUNTER) ARE 54" TALL.

ANY CONSTRUCTION DONE AFTER THE SITE VISIT:

IT WILL BE THE CUSTOMER'S RESPONSIBILITY TO

VERIFY ALL WALL, DOOR, COLUMN AND WINDOW

LOCATIONS TO ENSURE THE FURNITURE WILL FIT

PROPERLY. IF OEI IS NOT NOTIFIED OF ALL WALL

OBSTRUCTIONS SUCH AS THERMOSTATS, ANY

PRODUCTS AND/OR INSTALLATION CHARGES

NECESSARY DUE TO OBSTRUCTIONS WILL BE THE

CUSTOMER'S RESPONSIBILITY TO PURCHASE.

POPE AFB, NC

Sam Andrew

ALL DRAWINGS AND PRICE QUOTES RECEIVED ARE

CONSIDERED PROPRIETARY INFORMATION,

PROPERTY OF OEI/UNICOR AND CAN NOT BE

SHARED WITH ANY OTHER OUTSIDE ENTITY OTHER

THAN THE GOVERNMENT AGENCY TO WHICH THIS

INFORMATION WAS SENT UNTIL PRODUCT AND/OR

DESIGN IS PURCHASED BY THE INTENDED

GOVERNMENT AGENCY. AT THIS TIME IT BECOMES

THE PROPERTY OF THE PURCHASEER AND CAN BE

SHARED AS DEEMED NECESSARY BY THE

PURCHASER.

DESCRIPTIONDATE

TO ENSURE PROPER FIT OF FURNITURE VERIFY:

WALLS, COLUMNS, WINDOWS, DOORS, WINDOW

SILL HEIGHTS, ALL WALL FEATURES IE:

THERMOSTATS, LIGHT SWITCHES, ELECTRICAL,

HVAC, FIRE EXTINGUISERS, ALARMS

PANELS

BUILDING VERIFICATION

49 CTS

2/18/2026

DATE:

TRAINING & OPERATIONS RENDERING

TYPICAL WORKSTATION RENDERING

OPTION #:

CONFERENCE ROOM RENDERING

FLOOR PLAN

FLOOR/AREA:

SALESFORCE #:

DRAWN BY:

CC & SEL OFFICES RENDERING

PANEL KEY

SCALE:

REVISIONS:

FINISHES

V1.0

SHEET:

* SIZE VARIES TO FIT ROOMS

AS NOTED

FLOOR PLAN

DO/ADO RENDERING

DRAWING #:

TACTICS RENDERING

PROJECT TITLE:

U1 36/64

BASEFEED

(3 CIRCUITS)

BASEFEED

(2 CIRCUITS)

BASEFEED

(2 CIRCUITS)

DO/ADO

THIS ROOM NOT IN

UNICOR'S SCOPE

OF WORK

BASEFEED

(3 CIRCUITS)

TO BE DETERMINED

CONFERENCE ROOM

BASEFEED

(2 CIRCUITS)

RECEPTION

COUNTER

TACTICS

THIS AREA NOT IN

UNICOR'S SCOPE

OF WORK

TRAINING & OPERATIONS

SEL

THIS ROOM NOT IN

UNICOR'S SCOPE

OF WORK

BASEFEED

(5 CIRCUITS)

BASEFEED

(5 CIRCUITS)

CC

BASEFEED

(2 CIRCUITS)

INDICATES THE 'A SIDE'

INDICATES THE SIZE

File details come from the government source that posted it. Updated .