Appendix B UNICOR 26782181A FURNITURE PLAN.pdf
PDF 2 MB Posted
- Solicitation number
- FA445226R0017
About this file
This is a furniture floor plan and design drawing for a federal office space at Pope Air Force Base (PAFF), NC prepared by UNICOR. The project covers approximately 49 cost per square foot and includes the design and installation of modular office furniture across multiple functional areas: Command and Control (CC) and Sales Executive (SEL) offices, a conference room, training and operations area, and a tactics workspace. The document indicates that certain areas fall outside UNICOR's scope of work and are marked as "to be determined."
Each of the 34 workstations specified in the design will be equipped with an electric height-adjustable sit/stand desk, dual monitor arm, desktop power module, tackboard, and task light. The floor plan details electrical infrastructure requirements including multiple basefeeds (power distribution points) with varying circuit counts ranging from 2 to 5 circuits per basefeed that require hardwiring by a customer-provided certified electrician to the building source. Panel heights vary throughout the design, with overhead cabinet supporting panels at 66 inches tall, standard panels at 54 inches tall, and a 42-inch tall reception counter. The customer is responsible for verifying existing building features including walls, columns, windows, doors, thermostats, HVAC systems, switches, and alarms to ensure proper furniture fit and for coordinating with telephone, computer, and electrical installers prior to installation. All drawings and price quotes are designated as proprietary UNICOR/OEI information until purchase by the intended government agency.
View the file
Other files
Show all 16
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SIDE A&B
C6
(1) 3'6"
SIDE A&B
C9
(94) 4'6"
SIDE A&B
C10
(22) 5'6"
SIDE A
C11
(24)
5'6"
SIDE B SIDE A
C12
(13)
4'6"
SIDE B
STORM
H:3'0"
STORM
H:4'0"
STORM
H:5'0"
OPEN
H:2'0"
STORM
H:3'0"
OPEN
H:2'0"
STORM
H:3'0"
OPEN
H:2'0"
STORM
H:2'0"
OPEN
H:2'0"
STORM
H:2'0"
15 18
3'
-8
TY
P
TA
C
TI
C S, 0"
TY
P
TA
C
TI
C S, 0"
3' -1" 5'
-1 0"
TY
P
AL
L
D O
/A D
O
7' -0
TYP 4 TACTICS 6' -0"
TYP ALL DO/ADO, 6' -0"
TYP 15, 6' -6"
JUST THIS 1, 5' -0"
TY
P
6' -6
TYP 3 TACTICS, 5' -6"
1' -6
8' -0"
6' -6
1/1
DIS5
*SIGNATURE BELOW DENOTES CUSTOMER'S
ACKNOWLEDGEMENT THAT THE DESIGN HAS
EXPLAINED THE DRAWINGS, AND THAT THE
CUSTOMER FULLY UNDERSTANDS ALL FURNITURE
COMPONENTS RELATIVE TO HEIGHTS, WIDTHS, AND
COLOR SELECTIONS SPECIFIED ETC...
*SIGNATURE BELOW DENOTES FULL
COMPREHENSION OF ELECTRICAL SPECIFICATIONS
NEEDED FOR POWER AND DATA INFEED
LOCATIONS AS REPRESENTED ON THE DRAWINGS.
*SIGNATURE BELOW DENOTES CUSTOMER HAS
VERIFIED THAT ALL FURNITURE AND/OR EXISTING
WINDOWS, COLUMNSM THERMOSTATS, HVAC,
SWITCHES, AND ALARMS HAVE BEEN ACCOUNTED
FOR ON THE DRAWINGS. ANY LOCATION CHANGES
OF THESE ITEMS THAT HAVE AN EFFECT ON THE
FURNITURE LAYOUT ARE THE SOLE RESPONSIBLITY
OF THE CUSTOMER.
DATE:
SIGNATURE:
FLOOR PLAN
BYNO.
26782181A.cmdrw
DRAWING REVIEW
02/18/2026
SWA
2:23:47 PM
DIS4
IT IS THE CUSTOMER'S RESPONSIBILITY TO HAVE
THEIR TELEPHONE AND COMPUTER INTSTALLERS,
AND THEIR ELECTRICIANS REVIEW THE FURNITURE
AND ELECTRICAL PLANS PRIOR TO THE ACTUAL
FURNITURE INSTALLATION TO DETERMINE THE
EXTENT OF RE-WIRING THAT WILL BE REQUIRED. A
CERTIFIED ELECTRICIAN MUST MAKE THE
HARD-WIRE CONNECTION FROM THE TOP/BASE
FEED TO THE BUILDING SOURCE.
DIS8
NOTES:
1. (#) INDICIATES WORKSTATION (WS) NUMBER.
2. EACH WORKSTATION GETS AN ELECTRIC HEIGHT-ADJUSTABLE (SIT/STAND) DESK, DUAL MONITOR
ARM, DESKTOP POWER MODULE, TACKBOARD & TASKLIGHT.
3. CUSTOMER-PROVIDED ELECTRICIAN WILL HARDWIRE UNICOR-SUPPLIED POWER INFEEDS
("BASEFEED") TO BUILDING WHERE SHOWN ON FURNITURE PLAN. BASEFEEDS GET HARDWIRED TO BUILDING WALL. QUANTITY OF CIRCUITS THAT ELECTRICIAN WILL NEED TO HARDWIRE PER BASEFEED IS
NOTED IN PARENTHESIS.
4. BOTTOM-OPEN PANELS PROVIDED ALONG BUILDING WALLS TO PROVIDE EASIER ACCESS TO THE NEW
BASEFEEDS & EXISTING BUILIDNG WALL OUTLETS.
5. OVERHEAD CABINET SUPPORTING PANELS ARE 66" TALL. ALL OTHER PANELS (EXCEPT FOR 42" TALL
RECEPTION COUNTER) ARE 54" TALL.
ANY CONSTRUCTION DONE AFTER THE SITE VISIT:
IT WILL BE THE CUSTOMER'S RESPONSIBILITY TO
VERIFY ALL WALL, DOOR, COLUMN AND WINDOW
LOCATIONS TO ENSURE THE FURNITURE WILL FIT
PROPERLY. IF OEI IS NOT NOTIFIED OF ALL WALL
OBSTRUCTIONS SUCH AS THERMOSTATS, ANY
PRODUCTS AND/OR INSTALLATION CHARGES
NECESSARY DUE TO OBSTRUCTIONS WILL BE THE
CUSTOMER'S RESPONSIBILITY TO PURCHASE.
POPE AFB, NC
Sam Andrew
ALL DRAWINGS AND PRICE QUOTES RECEIVED ARE
CONSIDERED PROPRIETARY INFORMATION,
PROPERTY OF OEI/UNICOR AND CAN NOT BE
SHARED WITH ANY OTHER OUTSIDE ENTITY OTHER
THAN THE GOVERNMENT AGENCY TO WHICH THIS
INFORMATION WAS SENT UNTIL PRODUCT AND/OR
DESIGN IS PURCHASED BY THE INTENDED
GOVERNMENT AGENCY. AT THIS TIME IT BECOMES
THE PROPERTY OF THE PURCHASEER AND CAN BE
SHARED AS DEEMED NECESSARY BY THE
PURCHASER.
DESCRIPTIONDATE
TO ENSURE PROPER FIT OF FURNITURE VERIFY:
WALLS, COLUMNS, WINDOWS, DOORS, WINDOW
SILL HEIGHTS, ALL WALL FEATURES IE:
THERMOSTATS, LIGHT SWITCHES, ELECTRICAL,
HVAC, FIRE EXTINGUISERS, ALARMS
PANELS
BUILDING VERIFICATION
49 CTS
2/18/2026
DATE:
TRAINING & OPERATIONS RENDERING
TYPICAL WORKSTATION RENDERING
OPTION #:
CONFERENCE ROOM RENDERING
FLOOR PLAN
FLOOR/AREA:
SALESFORCE #:
DRAWN BY:
CC & SEL OFFICES RENDERING
PANEL KEY
SCALE:
REVISIONS:
FINISHES
V1.0
SHEET:
* SIZE VARIES TO FIT ROOMS
AS NOTED
FLOOR PLAN
DO/ADO RENDERING
DRAWING #:
TACTICS RENDERING
PROJECT TITLE:
U1 36/64
BASEFEED
(3 CIRCUITS)
BASEFEED
(2 CIRCUITS)
BASEFEED
(2 CIRCUITS)
DO/ADO
THIS ROOM NOT IN
UNICOR'S SCOPE
OF WORK
BASEFEED
(3 CIRCUITS)
TO BE DETERMINED
CONFERENCE ROOM
BASEFEED
(2 CIRCUITS)
RECEPTION
COUNTER
TACTICS
THIS AREA NOT IN
UNICOR'S SCOPE
OF WORK
TRAINING & OPERATIONS
SEL
THIS ROOM NOT IN
UNICOR'S SCOPE
OF WORK
BASEFEED
(5 CIRCUITS)
BASEFEED
(5 CIRCUITS)
CC
BASEFEED
(2 CIRCUITS)
INDICATES THE 'A SIDE'
INDICATES THE SIZE
File details come from the government source that posted it. Updated .