The document is a Statement of Need (SON) for the 60 MXS/MXMD (TMDE Flight) seeking a replacement 3-Phase AC Voltage power supply. The required equipment is critical for calibrating test equipment supporting multiple airframes including U-2, F-15, F-16, C-130, and C-17. The power supply must be capable of providing single-phase and 3-phase AC voltage outputs, operate on 120V/60Hz input power, and have specific technical capabilities including power line disturbance analysis, output sequencing, and harmonic analysis.

Key technical specifications include a 320 Vrms output, 3 kVA capacity, voltage range of 0-320V, maximum frequency of 5000 Hz, and safety features such as current protection, over/under-voltage monitoring, and soft start/stop functionality. The unit can be brand new or refurbished, with a desired warranty of 3-5 years. The contractor is required to ship the equipment within 30 days after contract award, and the power supply must be able to operate despite existing laboratory outlet issues with 3-phase and single-phase 400Hz facilities.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Statement of Need (SON) For

60 MXS/MXMD (TMDE Flight) Amendment 1

Description:

The 60 MXS TMDE Flight requires a replacement 3-Phase AC Voltage power supply. Currently the TMDE flight does not have an operational 3-phase power supply and is down a critical capability. Unit may be brand new or refurbished. The desired warranty for this product is 3-5 years.

Scope

The power supply simulates aircraft power and is used to calibrate test equipment supporting U-2, F-15 and F-16, C-130 and C-17 airframes. The power supply must be able to sustain power for calibration and the maintenance for test sets. The power supply must be able to operate off 120V/60Hz input power as there are issues in the laboratory with nearly all 3-phase and single phase 400Hz facility outlets. The power supply must be capable of producing both single-phase and 3-phase outputs.

This statement of need is not a request for fixing facility outlets; this request is for a stand-alone piece of equipment that is required regardless of the issues with the outlets.

The Contractor Shall Provide the Following:

1. Equipment

- Power Line Disturbance

- Output Sequencing

- Harmonic Analysis

- Built-In Waveform Generation

2. Safety

- Current Protection, Over, and Under-Voltage

- Output Inhibit Programming

- Soft Start / Stop Function

- Analog And Digital Control

- Lan (Lxi Core), USB, And Optional GPIB

2. Salient Characteristics:

- Capable of providing single phase and 3-Phase AC Voltage outputs

- 320 Vrms (Volts Root Mean Square)

- 3 kVA (Kilovolt-ampere)

- Voltage Range: Min. - 0V, Max - 320V

- Frequency Max: 5000 Hz

- Operate off 120V/60Hz input power

3. Shipping

1. Ship within 30 days after award of contract.

File details come from the government source that posted it. Updated .