Attachment 6 - RFIs and Maps.pdf
PDF 3 MB Posted
- Attached to
- Access Control System Federal contract opportunity
- Solicitation number
- FA441724Q0237
About this file
This document contains a series of Requests for Information (RFIs) related to a federal contract opportunity for an Access Control System at Hurlburt Field Air Force Base. The RFIs cover details such as the availability of scaled drawings, ceiling types, existing cable trays and wiring, UPS requirements, equipment substitutions, wire types, after-hours access, camera heights, equipment lists, pipe chases, budget information, progress payments, and the number of readers required. The related federal contract opportunity is for the installation, setup, programming, and training of an Access Control System, including the provision of all necessary supervision, labor, tools, equipment, supplies, badge printer, computer, server, badge readers, and other items. The solicitation number is FA441724Q0237 and is being issued by the Department of the Air Force Special Operations Command.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Amendment 1 - RFQ_FA441724Q0237.pdf | ||
| Attachment 2 - Provisions and Clauses.pdf | ||
| Attachment 3 - Statement of Work - ACS.pdf | ||
| Attachment 5 - SCA Wage Determination - ACS.pdf | ||
| Attachment 1 - RFQ_FA441724Q0237.pdf | ||
| Attachment 4 - Site Visit Instructions.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FA441724Q0237 – Access Control System RFIs
1. Are Scaled Drawings available, if so please post. See attachment
2. Are Ceilings Suspended? Or Hard Lid? Suspended
3. Are there existing Cable Trays for wiring above ceilings? Yes
4. Can Existing Wiring be utilized? Yes
5. Is a “UPS” required? If so, What Time/Power Duration is required? UPS required for Bldg 90063 with 2 hr duration. Bldg 90005 has backup power already
6. Are “Or Equal” Equipment substitutions allowed? Yes
7. Is “Plenum Wire” acceptable? Yes
8. Is “After Hours Access” for said work, available to contractor at no additional cost to the
Government? Possible. Would have to coordinate with us on requested hours
9. What is the height of Exterior Cameras? (If any) None yet
10. Please provide/post other “Q & A” requests. Unable to answer question
11. Please provide a list of equipment to be installed. Please refer to the statement of work
12. Are there pipe chases between floors? No
13. What is the range of the budget for this project, and is it already appropriated? Due to this being a service requirement, a range is not given.
14. Because of the high cost of the parts can we bill when parts arrive on site, or in the alternative are progress payments allowed? Progress payments are not allowed.
15. How many feet of new wire will have to be run? Unknown
16. What kind of cipher lock and quantities are required e.g. X-10 Cypher locks are already installed
17. What is the total number of readers that will be connected to this active control system? 19
18. Will Base Comm provide the network from Bldg 90063 to Bldg 90005 for the connection required to control the ACS System from one workstation? Yes
Map 90005 1st Floor
05/31/2013
Map 90005 2nd Floor