Equipment_Specifications.pdf

PDF 161 KB Posted

Attached to
Lektriever File System
Solicitation number
FA4407-18-Q-2030
Issued by

View the file

Other files

File Type Posted
SOW.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Equipment Specifications Overall Unit Specifications:

Base Unit includes lockable bi‐parting door (unless automatic door has been chosen), dust cover/top, all safety circuits, safety light curtain, emergency stop left & right side, touch bars (upper and lower), motor, manual handcrank, electronics and TUV label.

Quantity of Carousels : 1

Model Number : 125‐1311S Overall Unit Width : 103.54 inches (2630 mm)

Overall Unit Depth (without posting board) : 47.32 inches (1202 mm) Work Counter (posting board) Depth : 11.02 in. (280 mm)

Overall Unit Height : 90.56 inches (2300 mm) Minimum Ceiling Height: 91.35 inches (2320 mm) Unit Weight Empty (includes carrier weight) : 2346 lbs.

Unit Weight ‐ Fully Loaded : 5505 lbs.

Max. Total Load (including carrier dead weight) : 4070 kg (8,973 lb)

Top Tolerance at Balanced Load : +/‐ 15mm (.059")

*Units can be placed side by side, or back to back. When a unit is to be installed through a ceiling or in a niche, free space of approximately 1.2" (30 mm) is required all around the unit.

Average Floor Load (based on Unit weight‐‐fully loaded )

Supporting contact surface Dynamic Unit Weight (Newtons)

Dynamic Floor Load Bearing Capacity

1.12 lbs./in² (161.8 lbs./ft² )

130.5 in² /842 cm²

33,070

1.52 lbs./in² (218.88 lbs./ft² )

Maximum Imbalance Load Cycle Speed

Average Access Time (1/4 carousel revolution) Color Selection (Endframes)

Color Selection (Panels) Noise Level

300 kg (660 lbs)

7.0 inches / second

5.1 seconds Select Color Select Color < 60 db(A)

Access Opening Information:

Work Counter Type & Height

Work Counter Finish Door Type

Opening Clear Height Access Lighting

Mechanically Adjustable Between 30.31 in. and 39.37 in. (770mm and 1000mm) Light Gray Standard Manual Bi‐parting Door w/Keylock Maximum of 29.25 in. (743mm) or Minimum of 19.41 in. (493mm) Full Width Light Above Access Opening

Power & Controls:

Power Supply

Drive, Gear Motor AMP Draw

Average Power Consumption Control

Controller Location E‐Stop

Emergency Service Switch Computer Interface

110 Volt /1‐/60 Hz AC ‐ Gear Motor ‐ 1.5 kva 16 AMP Breaker Size: 20*

2.0 KVA *Cannot be wired to a breaker or outlet that uses a GFI circuit.

T0 Control Work Counter Included Left & Right Side of Access Opening Included No

Standard Safety Features Expanded Error Indicator Safety Light Curtain E‐ Stop Left & Right Side

Upper and Lower Mechanical Safety Bars (Doors) Safety Switches for Lower Front Access Panel and Hand Crank Opening Emergency Service Switch

Standard Features included in Base unit Electronics Located in the Bottom Access Panel Hand Crank for Installation of Carriers and Service Top Dust Cover

Access for Service from Front Additional Features and Options

Plastic Carrier Dividers, (2) Packs of 35

Carrier Specifications:

Specifications Per Carrier

Carousel's Carrier Configuration Qty Clear Height Clear

Width Clear Depth Max. Capacity *Avg. Capacity LFI Per Carrier Total LFI Per

Carrier Style Letter Lateral Carrier w/4 fixed dividers & BRF : Legal Lateral Carrier w/4 fixed dividers : 13 10.23 89.37 15.19 242 lbs. 242 lbs. 89 1157

Letter Tray Carrier w/4 fixed dividers : Legal Tray Carrier w/4 fixed dividers‐ Top Tab Trays : Legal Tray Carrier w/4 fixed dividers‐ Hanging Trays : Carrier with 60 deg.Lip : : : : Letter File Drawer Carrier (3+4 Configuration) : Legal File Drawer Carrier (3+2 Configuration) : Letter Hanging Frame Carrier (3+3 Configuration) : Legal Hanging Frame Carrier (2+3 Configuration) :

Useful height / drawer Clear width / drawer Clear depth

/ drawer # of Drawers / Carrier Avg. Capacity /

Drawer

LFI Per Carrier

: N/A Total Linear Filing Inches (LFI) for 1 unit(s) : 1157 Multimedia Carriers/Drawers are not included in Total LFI calculation

(Does not include carriers with additional shelves or drawers) *Avg. capacity is based on a unit configured with one carrier type.

File details come from the government source that posted it.