FA3099-17-R-0005 Question and Answers.

1. It is noticed that MIL-STD-704 has not used 28.5 volts as the nominal since 1959 when it changed to

28.0 nominal. Is the output nominal voltage 28.5 voltage or 28 volts, or does it make any difference?

A: Our current units are set at 28.5 VDC. That is what we are told the aircraft requires.