FA301618R00080003_-_Amendment_Large_Capacity_Washer-Dryer.pdf

PDF 52 KB Posted

Attached to
JBSA - Fort Sam Houston Washer and Dryer Lease and Maintenance
Solicitation number
FA301618R0008
Issued by

About this file

Amendment 0003

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT

Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.

15A. NAME AND TITLE OF SIGNER (Type or print)

30-105-04EXCEPTION TO SF 30

APPROVED BY OIRM 11-84

STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA

FAR (48 CFR) 53.243

1. To incorporate new PWS dated 9 April 2018 w hich adds paragraphs 1.1.5.1 Large Capacity Washers along w ith additon of paragraph

1.1.6.1 Large Capacity Dryers. Appendix A and B have been adjusted. Appendix A adds equipment w hile Appendix B adds information on Large capacity Washers and and Large capacity Gas Dryers.

2. To extend the response date to 25 April 2018 at 12:00pm CST

Contracting Officer: Timothy J. Hull, timothy.hull.6@us.af.mil, (210)671-1717 Contract Specialist: Jack A. Caniglia, jack.caniglia.3@us.af.mil, (210)671-1721

1. CONTRACT ID CODE PAGE OF PAGES

J 1 6

16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)

16C. DATE SIGNED

BY 17-Apr-2018

16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR

(Signature of Contracting Officer)(Signature of person authorized to sign)

8. NAME AND ADDRESS OF CONTRACTOR (No., Street, County, State and Zip Code) X FA301618R0008

X 9B. DATED (SEE ITEM 11)

05-Mar-2018

10B. DATED (SEE ITEM 13)

9A. AMENDMENT OF SOLICITATION NO.

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer X is extended, is not extended.

Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:

(a) By completing Items 8 and 15, and returning 1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;

or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

12. ACCOUNTING AND APPROPRIATION DATA (If required)

13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.

IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.

A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE

CONTRACT ORDER NO. IN ITEM 10A.

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER (Specify type of modification and authority)

E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

10A. MOD. OF CONTRACT/ORDER NO.

2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)

6. ISSUED BY

3. EFFECTIVE DATE

16-Apr-2018

CODE

502D CONTRACTING SQUADRON

1655 SELFRIDGE AVE

JBSA LACKLAND TX 78236-5253

FA3016 7. ADMINISTERED BY (If other than item 6)

4. REQUISITION/PURCHASE REQ. NO.

CODE

See Item 6

FACILITY CODECODE

EMAIL:TEL:

FA301618R0008

SECTION SF 30 BLOCK 14 CONTINUATION PAGE

SUMMARY OF CHANGES

SECTION SF 1449 - CONTINUATION SHEET

SOLICITATION/CONTRACT FORM

The required response date/time has changed from 03-Apr-2018 02:00 PM to 25-Apr-

2018 12:00 PM.

SUPPLIES OR SERVICES AND PRICES

CLIN 0011 is added as follows:

ITEM NO SUPPLIES/SERVICES ESTIMATED

QUANTITY

UNIT UNIT PRICE ESTIMATED AMOUNT

0011 72 Each Large Capacity Washers/Dryers

FFP

Large Capacity Washers - Washers listed on Appendix A as “large capacity” shall be hard mount machines with no smaller than 30 lb capacity. Contractor shall be responsible for installing a 6” steel base under each washer to allow for convenience of use. At installation, contractor shall bolt/secure washers to the concrete floor to ensure safety during use of the machines. IAW PWS 1.1.5.1. 3 Each X 12 months Large Capacity Dryers. Dryers shall be as indicated on Appendix A and shall be no smaller than 30 lb capacity. Dryers shall have a “push to start” button/panel, which operates only when door is closed.

IAW PWS 1.1.6.1 3 each X 12 months FOB: Destination

ESTIMATED

NET AMT

CLIN 0110 is added as follows:

UNIT UNIT PRICE ESTIMATED AMOUNT

0110 72 Each Large Capacity Washers/Dryers

FFP

Large Capacity Washers - Washers listed on Appendix A as “large capacity” shall be hard mount machines with no smaller than 30 lb capacity. Contractor shall be responsible for installing a 6” steel base under each washer to allow for convenience of use. At installation, contractor shall bolt/secure washers to the concrete floor to ensure safety during use of the machines. IAW PWS 1.1.5.1. 3 Each X 12 months Large Capacity Dryers. Dryers shall be as indicated on Appendix A and shall be no smaller than 30 lb capacity. Dryers shall have a “push to start” button/panel, which operates only when door is closed.

CLIN 0210 is added as follows:

UNIT UNIT PRICE ESTIMATED AMOUNT

0210 72 Each Large Capacity Washers/Dryers

FFP

Large Capacity Washers - Washers listed on Appendix A as “large capacity” shall be hard mount machines with no smaller than 30 lb capacity. Contractor shall be responsible for installing a 6” steel base under each washer to allow for convenience of use. At installation, contractor shall bolt/secure washers to the concrete floor to ensure safety during use of the machines. IAW PWS 1.1.5.1. 3 Each X 12 months Large Capacity Dryers. Dryers shall be as indicated on Appendix A and shall be no smaller than 30 lb capacity. Dryers shall have a “push to start” button/panel, which operates only when door is closed.

CLIN 0310 is added as follows:

UNIT UNIT PRICE ESTIMATED AMOUNT

0310 72 Each Large Capacity Washers/Dryers

FFP

Large Capacity Washers - Washers listed on Appendix A as “large capacity” shall be hard mount machines with no smaller than 30 lb capacity. Contractor shall be responsible for installing a 6” steel base under each washer to allow for convenience of use. At installation, contractor shall bolt/secure washers to the concrete floor to ensure safety during use of the machines. IAW PWS 1.1.5.1. 3 Each X 12 months Large Capacity Dryers. Dryers shall be as indicated on Appendix A and shall be no smaller than 30 lb capacity. Dryers shall have a “push to start” button/panel, which operates only when door is closed.

CLIN 0410 is added as follows:

UNIT UNIT PRICE ESTIMATED AMOUNT

0410 72 Each Large Capacity Washers/Dryers

FFP

Large Capacity Washers - Washers listed on Appendix A as “large capacity” shall be hard mount machines with no smaller than 30 lb capacity. Contractor shall be responsible for installing a 6” steel base under each washer to allow for convenience of use. At installation, contractor shall bolt/secure washers to the concrete floor to ensure safety during use of the machines. IAW PWS 1.1.5.1. 3 Each X 12 months Large Capacity Dryers. Dryers shall be as indicated on Appendix A and shall be no smaller than 30 lb capacity. Dryers shall have a “push to start” button/panel, which operates only when door is closed. IAW PWS 1.1.6.1 3 each X 12 months

DELIVERIES AND PERFORMANCE

The following Delivery Schedule for CLIN 0011 has been added:

DELIVERY DATE QUANTITY SHIP TO ADDRESS DODAAC /

CAGE

POP 01-MAY-2018 TO

30-APR-2019

N/A 502 CES/CE F2MRAA

CARMEN LEAL

2202 15TH ST STE 7

JB FORT SAM HOUSTON TX 78234-5007

210-221-3956

F2MRAA

The following Delivery Schedule for CLIN 0110 has been added:

CAGE

POP 01-MAY-2019 TO

30-APR-2020

N/A 502 CES/CE F2MRAA

CARMEN LEAL

2202 15TH ST STE 7

JB FORT SAM HOUSTON TX 78234-5007

210-221-3956

The following Delivery Schedule for CLIN 0210 has been added:

CAGE

POP 01-MAY-2020 TO

30-APR-2021

N/A 502 CES/CE F2MRAA

CARMEN LEAL

2202 15TH ST STE 7

JB FORT SAM HOUSTON TX 78234-5007

210-221-3956

The following Delivery Schedule for CLIN 0310 has been added:

CAGE

POP 01-MAY-2021 TO

30-APR-2022

N/A 502 CES/CE F2MRAA

CARMEN LEAL

2202 15TH ST STE 7

JB FORT SAM HOUSTON TX 78234-5007

210-221-3956

The following Delivery Schedule for CLIN 0410 has been added:

CAGE

POP 01-MAY-2022 TO

30-APR-2023

N/A 502 CES/CE F2MRAA

CARMEN LEAL

2202 15TH ST STE 7

JB FORT SAM HOUSTON TX 78234-5007

210-221-3956

INSPECTION AND ACCEPTANCE

The following Acceptance/Inspection Schedule was added for CLIN 0011:

INSPECT AT INSPECT BY ACCEPT AT ACCEPT BY

Destination Government Destination Government

The following Acceptance/Inspection Schedule was added for CLIN 0110:

The following Acceptance/Inspection Schedule was added for CLIN 0210:

The following Acceptance/Inspection Schedule was added for CLIN 0310:

The following Acceptance/Inspection Schedule was added for CLIN 0410:

The following have been added by full text:

ATTACHMENTS

DOCUMENT NAME DATE PAGES

Performance Work Statement 9 April 2018 14

(End of Summary of Changes)

File details come from the government source that posted it.