4 Classroom Layouts.pdf

PDF 73 KB Posted

Attached to
Classroom Desk Furniture
Solicitation number
FA3010_Classroom_Desk_Mendoza
Issued by

About this file

This document is a classroom layout specification for four training rooms (Rooms 121, 122, 123, and 125), each measuring 23 feet by 26 feet. All floors in these spaces are raised 6 inches, with specific non-raised floor and HVAC areas identified and marked in red/white gradient coloring. Each room is designed to accommodate multiple desk rows with student workstations, indicated by black squares representing individual seats or terminals, and instructor desks marked in white. The layouts maintain approximately 5-foot spacing between desk columns and feature a 3-foot gap between the middle row of desks for traffic flow and accessibility.

Ethernet cable infrastructure is provided from two designated locations per room, marked in green, with wall ports positioned by instructor decks and cable routing through metal panels or drilled holes. The rooms include bump-outs and HVAC units positioned along walls, with doorways clearly marked for access. Measurements throughout are approximate, and desk row staggering is noted as an optional configuration element. The layouts are designed to be approximately consistent across all four rooms, though each has slight variations in HVAC placement, non-raised floor areas, and Ethernet access point locations to accommodate individual room dimensions and structural features.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

• All measurements are approximate.

• All floors are raised 6”

• Should be a 3 ft gap between middle row

• Bump-outs, HVAC, and lower floors are colored red/white gradient.

• Ethernet Cables can come from two locations (colored green)

• Wall ports by instructor decks

• Metal panels or holes running cables

• Layouts will be approximately the same

• Staggering of desk rows can be an option

Non raised floor

23’

26’

5’ 5’ 5’ 5’

5’ 5’ 5’ 5’

Rm 125

6'

4' 7’

4'

6’

4’

HVAC

Doorway

Rm 122

5’ 5’

5’ 5’

5’ 5’

5’ 5’

6’

4’

4’

4’ 7'

4'

23’

26’

HVAC Non raised floor

Rm 123

5’ 5’ 5’ 5’

5’ 5’ 5’ 5’

7'

4'

5'

7'

6.5” 31”

6’

4’

HVAC Non raised floor

23’

26’

Non raised floor

23’

26’

Rm 121

HVAC

6’

4’

6.5” 10”

5’ 5’ 5’ 5’

5’ 5’ 5’ 5’

5’

6’

7’

5’

9” 32”

Slide Number 1
Slide Number 2
Slide Number 3
Slide Number 4
Slide Number 5

File details come from the government source that posted it. Updated .