O N L I N E I N F O R M A T I O N

Andrews Air Force Base Building #3149

Andrews AFB, MD 20762

Tremco Incorporated 20 November 2014

TABLE OF CONTENTS

1. Introduction Explanation of report objectives, methods of data collection and explanation of the seven categories of maintenance recommendations.

2. Executive Summary Summarized information, presented in numeric and graphical formats, to provide an overview of your roofing inventory: number of roofs, square footage, age and condition by facility.

3. Budget Summary Summarized budget information in graphical format for each facility.

4. Roof Details - Andrews Air Force Base Full details of the roof data collected for Andrews Air Force Base

SECTION 1.

INTRODUCTION

Tremco

Incorporated Andrews Air Force Base Section 1, Introduction

REPORT CONTENT

Your report provides information essential to the analysis of your roofing investment and development of action plans. It will assist you to effectively and efficiently manage your roofing expenditures. The data you need in order to maintain your roofs in the optimum condition and preserve your substantial investment is provided.

Information is organized into the Executive Summary section followed by details for each roof. The Executive Summary provides overall information on your roofing inventory, asset value, the condition of roofs and budget amounts for maintenance, replacement and restoration work. Information is presented in numerical and graphical formats and is supported by data and recommendations for each individual roof area.

A roof area is defined by the following feature(s): An elevation change separation by walls, fire walls, expansion, control joints or a change of construction.

INFORMATION COLLECTION

Information collected includes historical data, construction and condition information. The information is collected by well trained, experienced roof inspectors. The inspection consists of on-site interviews whenever possible, a visual examination of the roof and extractions of roof samples for analysis. All accessible roof projections and equipment are inspected.

Information about the roof insulation and deck are based on what the inspector is able to determine by field examination of a core where possible and a visual examination of the underside of the deck if accessible.

This report and associated recommendations are based on the conditions at the time of the inspection. Both conditions and recommendations will change with time, weather and normal wear and tear associated with roofs.

CONDITION CATEGORIES

Your inspected roofing inventory has been classified into condition categories. Based on this analysis of certain key characteristics and noted conditions on each roof. Some conditions are clear indicators of future problems. Prompt attention to certain issues now may avoid or forestall a major expenditure later.

The condition categories are as follows: 1 . 0 - Red 2 . 10 - Red 3 . 20 - Red 4 . 30 - Amber 5 . 40 - Amber 6 . 50 - Amber 7 . 60 - Amber 8 . 70 - Amber 9 . 80 - Green

10. 90 - Green

11. 100 - Green

12. No Condition Recorded

The assignment of a roof to one of these categories is based on data collected. It does not take into account owner preferences or knowledge of a building or its anticipated future. These factors must be the subject of discussion using the inspection data as a base. This step may well result in a re-organization priority assessment.

FOLLOW-UP WORK

Expanded recommendations, comprehensive specifications and pertinent cost estimates will be provided to you upon request, based on a more exhaustive on-site examination of the roof areas identified as priorities.

Use the services of Tremco Incorporated Account Executive to supplement the information in this report to help in establishing priorities and in the management of your roofing investment.

Section 2.

Executive Summary

12.1 Overview

12.2 Roofing Inventory Examined

12.3 Roof Inventory Distribution

12.4 Square Footage Distribution

12.5 Age Analysis by Square Feet

12.6 Condition Category by Square Feet

12.7 Roof Membrane Type by Square Feet

12.8 Age Analysis by Membrane Type

12.9 Condition by Membrane Type

Andrews Air Force Base

2. Executive Summary

2.1 Overview

This section provides information in numeric and graphical formats to summarize the detailed data in the body of this report.

This section essentially answers four questions:

1. “What roofing inventory do we have?”

2. “What condition is it in?”

3. “What will it cost to undertake the necessary work?”

4. “Where can I save through maintenance and/or restoration?” The contents of this section are as follows:

1. Summary of the roofing inventory examined with total number of buildings and square footage.

2. Analysis based on number of roofs.

3. Analysis based on square footage.

4. Analysis based on condition categories.

5. Analysis based on roof type.

2.2 Roofing Inventory Examined

Number of Buildings

Number of Individual Roof Areas

Total Square Footage

5,523

Total Asset Value (replacement cost) removed

Building #3149

Andrews Air Force BaseAsset Value
Sq. Ft.

Building #3149

Roof Aremoved
4,905
Roof Bremoved
143
Roof Cremoved
475
Building Total:3 roof area(s)removed
5,523

Tremco

Incorporated Tremco

Incorporated

2.3 Roof Inventory Distribution

Unable to generate graph check input values )Building #3149

1 2 3 4 5

Number of Roofs

2.4 ( to generate graph check input values )Square Footage Distribution

Building

#3149 5,523 2,000 4,000 6,000 8,000 10,000 Square Footage

Tremco

Incorporated Tremco

Incorporated

2.5 Age Analysis by Square Feet

to generate graph check input

)0-5 Years

0-5 Years

6-10 Years

6-10 Years

11-20 Years

>20 Years

11-20 Years

Unknown

5,523

Unknown

2,000 4,000 6,000 8,000 10,000

Square Feet

2.6 Condition Category by Square Feet

to generate graph check input

)0 - Red

10 - Red

20 - Red

30 - Amber

40 - Amber

50 - Amber

5,523

0 - Red

20 - Red 30 - Amber 40 - Amber 50 - Amber 60 - Amber 70 - Amber 80 - Green 90 - Green 100 - Green No Condition Recorded

60 - Amber

70 - Amber

80 - Green

90 - Green

100 - Green

No Condition Recorded

2,000 4,000 6,000 8,000 10,000

Square Footage

2.7 Roof Membrane Type by Square Feet

to generate graph check input

)Asphalt (BUR)

Asphalt (BUR)

5,048

2,000 4,000 6,000 8,000 10,000

2.8 Age Analysis by Membrane Type

to generate graph check input

2,000 4,000 6,000 8,000 10,000

2.9 Condition by Membrane Type

to generate graph check input

0 - Red

20 - Red 30 - Amber 40 - Amber 50 - Amber 60 - Amber 70 - Amber 80 - Green 90 - Green 100 - Green No Condition Recorded

2,000 4,000 6,000 8,000 10,000

3.1 Recommended Budget Summary by Roof

Andrews Air Force Base Building #3149

Building name
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023

Subtotal

Annual Total

Incorporated Tremco

Incorporated

3.2 Recommended Budget Summary by Task

Andrews Air Force Base Building #3149

Building name
Task
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023

Annual Total

Maintenance Summary - Work Performed

Andrews Air Force Base

Andrews Air Force Base
Type
Description
Completed

Building #3149

Roof A
TremCare
Repaired open gravel stop.
January 18,
Roof B
TremCare
No maintenance performed at this time.
December 27, 2012
Roof C
TremCare
No maintenance performed at this time.
December 27, 2012

Incorporated Tremco

Incorporated

Maintenance Summary - Customer's Responsibility

Andrews Air Force Base

Andrews Air Force Base
Type
DescriptionRecommended
Roof B
Repairs Required, Minor
Recommend replacing roof.
Roof C
Repairs Required, Minor
Recommend replacing roof. Recommend repairing interior ladder for access.

Overall Roof Condition

Number of Buildings1
Number of Individual Roof Areas3
Total Square Footage5,523
Andrews Air Force BaseBuilding #3149

20 - Red

Region/Facility

Building

Roof

Sq. Ft. Inspection Comments

Andrews Air Force Base

Building #3149

Roof A 4,905 The plys are brittle, the gravel stop is open and the flashings are in poor condition.

Leak in wall vent on the exterior wall. (not a roof leak)

Roof B143 The plys are brittle and flashings are open and brittle.
Roof C475 There is no safe access at this time. The inside ladder can not be used due to safety issues.

Roof(s) 5,523

Sq.

Ft.

Grand Total 3 Roof(s)

5,523 Sq. Ft.

Andrews Air Force Base

Andrews AFB, MD 20762

An escort is required to access the building.

Tremco Incorporated

Tremco

Incorporated Andrews Air Force Base Building #3149 Roof A

GENERAL INFORMATION

Roof NameRoof A
Service Activity TypeTremCare Gold Service Activity DateJan 18 2013
Job Number124427
Information SourceCore
Year of Installation1989 (Estimate)
Roof LeaksNo
Leak SensitivityMedium
Roof Size4,905 sq. ft.
# of Stories1
Is Ladder Required?Yes
Asset Valueremoved
Total Asset Valueremoved Overall Roof Condition20 - Red
Inspection CommentsThe plys are brittle, the gravel stop is open and the flashings are in poor condition.

Leak in wall vent on the exterior wall. (not a roof leak) Technician Todd Rexrode

ROOF CONSTRUCTION

SurfacingAggregate
MembraneAsphalt (BUR)
Ply Info4 plys Organic, Hot Adhered
Deck TypeLightweight Concrete

DRAINAGE AND SLOPE

DrainageDrains
Slope1/4" inch(es) per foot

Andrews Air Force Base Building #3149

PERIMETER, WALL AND COPING

Type
Condition(s)
Magnitude
Severity
Perimeter Type
Gravel Stop
Weathered
Moderate
Moderate

Non-Parapet Wall

Wall Type
Metal Clad Wall
Good Condition
Perimeter Wall and Flashing Type
Felt - Smooth
Brittle
Extensive
Critical
Cracked
Extensive
Critical
Weathered
Extensive
Critical

Metal

Counterflashing Type
Face Mount
Fair Condition
Counterflashing Material Type
Coated
Fair Condition
Copper
Weathered
Moderate
Moderate
Projection Flashings Type
Felt - Smooth
Brittle
Extensive
Critical
Cracked
Extensive
Critical
Weathered
Extensive
Critical
Lead
Weathered
Moderate
Moderate

PROJECTION AND EQUIPMENT

Type Total Require Attention

Drain(s)40
Soil Stack(s)10
Ventilator(s) (Curb)40

ROOF CONDITIONS

Defect(s)
Magnitude
Severity
Cracked
Extensive
Critical
Embrittlement
Extensive
Critical
Exposed Felt
Moderate
Moderate
Displaced Aggregate
Moderate
Moderate
Patches
Moderate
Moderate
Splits
Moderate
Moderate

MAINTENANCE SUMMARY

Work

Performed TremCare Repaired open gravel stop.

Tremco

Incorporated Tremco

Incorporated Andrews Air Force Base Building #3149

CONTRACTOR OPEN ITEMS

Contractor Responsibility

Title TremCare

Date Recorded January 18, 2013

Description Recommend replacing the roof. Recommend sealing vent on exterior wall.

Service Activity Photos

Overview. Overview. Overview. Overview.

Building #3149 Roof A

Tremco

Incorporated Tremco

Incorporated

Leaking area of roof repaired by other contractor. Open perimeter edge metal.

Repaired perimeter edge metal.

Curb flashing detail.

Cracks in roof surface. Cracks in roof surface.

Andrews Air Force Base Building #3149 Roof B

Roof NameRoof B
Service Activity TypeTremCare Gold Service Activity DateDec 27 2012
Job Number124427
Information SourceCore
Year of Installation1989 (Estimate)
Roof LeaksNo
Leak SensitivityMedium
Roof Size143 sq. ft.
# of Stories2
Is Ladder Required?Yes
Asset Valueremoved
Total Asset Valueremoved Overall Roof Condition20 - Red
Inspection CommentsThe plys are brittle and flashings are open and brittle. TechnicianTodd Rexrode

ROOF CONSTRUCTION

SurfacingAggregate
MembraneAsphalt (BUR)
Ply Info4 plys Organic, Hot Adhered
Deck TypeLightweight Concrete

DRAINAGE AND SLOPE

DrainageDrains
Slope1/4" inch(es) per foot

Andrews Air Force Base Building #3149

PERIMETER, WALL AND COPING

Type
Condition(s)
Magnitude
Severity
Perimeter Type
Gravel Stop
Fair Condition
Moderate
Moderate
Leaking
Moderate
Moderate
Weathered
Moderate
Moderate
Non-Parapet Wall
Good Condition
Wall Type
Metal Clad Wall
Good Condition
Perimeter Wall and Flashing Type
Felt - Smooth
Brittle
Moderate
Moderate
Cracked
Moderate
Moderate
Leaking
Moderate
Moderate
Missing
Moderate
Moderate

Metal

Counterflashing Type
Face Mount
Good Condition
Counterflashing Material Type
Coated
Good Condition
Projection Flashings Type
Modified Bitumen
Brittle
Moderate
Moderate
Kickholes
Moderate
Moderate
Leaking
Moderate
Moderate
Weathered
Moderate
Moderate

PROJECTION AND EQUIPMENT

Type Total Require Attention

Drain(s)10
Soil Stack(s)10
Ventilator(s) (Curb)10

ROOF CONDITIONS

Defect(s)
Magnitude
Severity
Cracked Embrittlement Weathered
Extensive Extensive Extensive
Critical Critical Critical

Work

Performed TremCare No maintenance performed at this time.

Tremco

Incorporated Tremco

Incorporated Andrews Air Force Base Building #3149

Work

Beyond

Scope of

Maintenance Agreement

(Customer

Responsibility)

)OUTSTANDING BUDGET

Task
Year
Project $
Task Description

Repairs Required, Minor

Recommend replacing roof.

Overview. Overview.

Deteriorated curb flashing.

Andrews Air Force Base Building #3149 Roof C

Roof NameRoof C
NotesThere is no safety access at this time. Service Activity TypeTremCare Gold
Service Activity DateDec 27 2012
Job Number124427
Information SourceCore
Year of Installation1989 (Estimate)
Roof LeaksNo
Leak SensitivityMedium
Roof Size475 sq. ft.
# of Stories6
Is Ladder Required?No
Asset Valueremoved
Total Asset Valueremoved Overall Roof Condition20 - Red
Inspection CommentsThere is no safe access at this time.

The inside ladder can not be used due to safety issues.

Technician Todd Rexrode

Work

Performed

TremCare No maintenance performed at this time.

OUTSTANDING BUDGET

Work

Beyond

Scope of

Maintenance Agreement

(Customer

Responsibility) Task Year Project

Task Description Repairs Required, Minor Recommend replacing roof.

Recommend repairing interior ladder for access.

Roof C

No safe access.

Leaking vent on exterior wall.

image2.jpeg image3.png image4.jpeg image5.png image6.jpeg image7.jpeg image8.jpeg image9.jpeg image10.jpeg image11.jpeg image12.jpeg image13.jpeg image14.jpeg image15.jpeg image16.png image17.jpeg image18.jpeg image19.jpeg image20.png image21.jpeg image22.jpeg image1.jpeg