Questions and Answers #5 and 6.

Q5: “….interprets “Median Height” as meaning ±12” when 24” over vertical height is requested. Points 4 & 5 (see below) indicate a maximum + travel of 5” for F-15 and, + travel of 8” for F-16. Please clarify”

A5: The solicitation has been modified to remove the maximum height verbiage from points 4 and 5 of the minimum requirements/salient characteristics section, and the solicitation deadline has been extended to 17 APR 19, by 10:00 A.M., Central Daylight Time (CDT) to account for the change.

Points 4 and 5, minimum requirements/salient characteristics section of solicitation, have been modified in the solicitation as stipulated below:

4. Must have Adjustable Height within plus (+) or minus (-) 12 inches from a Median Height of 105 inches for the F-15C/D/E.

5. Must have Adjustable Height within plus (+) or minus (-) 12 inches from a Median Height of 65 inches for the F-16C/D.

Q6: “Also, pint 14 “ All maintenance platform stands mush have all removable pins/railings attached with lanyards to prevent FOD”……Point 22 “ This requirement does not require lanyards” Which is it?”

A6: We do not require personal fall arrest lanyards of any kind, but we do require lanyards for removable bolts/pins/railings as stipulated in solicitation. Point 22 of minimum requirements/salient characteristics section of solicitation has been modified to state that personal fall arrest lanyards are not required.

Point 22, minimum requirements/salient characteristics section of solicitation, has been changed to read as follows:

22. This Requirement Does Not Require Personal Fall Arrest Lanyards of any kind.