Attach_B_-_Drawings.pdf
PDF 3 MB Posted
- Solicitation number
- FA282318R4011
About this file
Attach B - Drawings
View the file
Other files
Show all 29
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CARRICO.STEPH
EN.P.1104609844
Digitally signed by
CARRICO.STEPHEN.P.11046098
Date: 2018.04.23 08:46:27 -05'00'
MILEY.JOHN.
K.1114537140
Digitally signed by
MILEY.JOHN.K.1114537140
Date: 2018.05.04 06:13:00 -05'00'
GRIM.ROBERT
.J.1148529910
Digitally signed by
GRIM.ROBERT.J.1148529910
Date: 2018.04.20 09:18:58 -05'00'
CHRISTMAN.DON
ALD.J.1145288246
Digitally signed by
CHRISTMAN.DONALD.J.11452882
Date: 2018.04.26 14:46:52 -05'00'
BROWN.RUSSEL
L.A.1230011881
Digitally signed by
BROWN.RUSSELL.A.1230011881
Date: 2018.04.25 10:19:51 -05'00'
MASSEY.MICHAEL.A.
1046155730
Digitally signed by
MASSEY.MICHAEL.A.1046155730
Date: 2018.04.23 05:54:58 -05'00'
FERNANDEZ.MICHAEL.J.
1230018720
Digitally signed by
FERNANDEZ.MICHAEL.J.1230018720
Date: 2018.05.03 13:59:10 -05'00'
MOORER.EUGENE.JR.1230
057237
Digitally signed by
MOORER.EUGENE.JR.1230057237
Date: 2018.05.07 08:32:59 -05'00'
ROBEEN.DANIEL.B.1230040679 Digitally signed by ROBEEN.DANIEL.B.1230040679 Date: 2018.05.21 13:30:43 -05'00'
SCHLUETER.MARK.A.1136656933 Digitally signed by SCHLUETER.MARK.A.1136656933 Date: 2018.05.22 07:49:33 -05'00'
BLALOCK.STEP
HEN.D.110312
Digitally signed by
BLALOCK.STEPHEN.D.11
03123000 Date: 2018.06.12 08:27:27 -05'00'
FP-001
FP-101
FP-102
FP-103
FP-104
FP-105
FP-106
FP-107
FP-501
N
FIRE ALARM PLAN - EQUIPMENT BUILDING
SCALE: 1/4" = 1''-0"
F A
C P
EXISTING FIRE ALARM CONTROL
PANEL - SIMPLEX # 4010.
F
EXTEND TO EXISTING FIRE ALARM CONTROL PANEL.
F
HEAT TRACE CONTROLLER W/ INTEGRAL
GROUND FAULT CIRCUIT PROTECTION -
SUPPLIED BY MECHANICAL CONTRACTOR.
EXTEND TO EXISTING FIRE ALARM CONTROL PANEL. THE
CONTRACTOR SHALL BE RESPONSIBLE FOR ANY ADDITIONAL
INTERFACE MODULES REQUIRED AND REPROGRAMMING OF THE
EXISTING FIRE ALARM PANEL TO PROVIDE A COMPLETE SYSTEM
IN ACCORDANCE WITH NFPA 72, AND MONITORING OF THE HEAT
TRACE SYSTEM IN ACCORDANCE WITH NFPA 13 AND NFPA 14.
HEAT TRACE FIRE ALARM RISER DIAGRAM
N.T.S.
T
S
TEMPORARILY DISCONNECT EXISTING FIRE ALARM
CONNECTION TO EXISTING TAMPER SWITCH & AND
FLOW SWITCH AND RECONNECT TO NEW TAMPER
SWITCH AND FLOW SWITCH.
F
S
T
S
F
S
T
S
J
J
X
X
F
F
F
N
FIRE ALARM PLAN - TOWER CONTROL AREA LEVEL
SCALE: 1/4" = 1''-0"
DISCONNECT EXISTING FIRE ALARM
CIRCUITS FROM EXISTING SPRINKLER
SYSTEM FLOW AND TAMPER SWITCH.
EXTEND FIRE ALARM CIRCUITS FROM
EXISTING JUNCTION BOX TO NEW
SPRINKLER SYSTEM FLOW AND
TAMPER SWITCH.
FIRE ALARM LEGEND:
J
J
FACP
T
S
F
S
T
S
F
S
EXISTING JUNCTION BOX - TO REMAIN.
NEW JUNCTION BOX - 4" SQUARE, UNLESS NOTED OTHERWISE.
EXISTING FIRE ALARM CONTROL PANEL - TO REMAIN.
EXISTING SPRINKLER SYSTEM FLOW SWITCH - REMOVE EXISTING CONNECTION.
EXISTING SPRINKLER SYSTEM TAMPER SWITCH - REMOVE EXISTING CONNECTION.
NEW SPRINKLER SYSTEM FLOW SWITCH CONNECTION.
NEW SPRINKLER SYSTEM TAMPER SWITCH CONNECTION.
EXISTING FIRE ALARM CONDUIT & WIRING - REMOVE.
F
NEW FIRE ALARM CONDUIT & WIRING - AS REQUIRED BY EXISTING SIMPLEX SYSTEM.
X X
F
S
FA-101
PENSACOLA, FLORIDA 32502
75 SOUTH "F" STREET
PETERSON ENGINEERING INC.
(850) 434-0513
F
S
T
S
J
F
F
F
S
T
S
F
S
T
S
J
J
X
X
F
F
F
TEMPORARILY DISCONNECT EXISTING FIRE ALARM
CIRCUITS FROM EXISTING SPRINKLER SYSTEM
TAMPER SWITCH & RECONNECT TO NEW TAMPER
SWITCH.
DISCONNECT EXISTING FIRE ALARM
CIRCUITS FROM EXISTING SPRINKLER
SYSTEM FLOW AND TAMPER SWITCH.
EXTEND FIRE ALARM CIRCUITS FROM
EXISTING JUNCTION BOX TO NEW
SPRINKLER SYSTEM FLOW AND
TAMPER SWITCH.
N
FIRE ALARM PLAN - TOWER EQUIPMENT AREA LEVEL
SCALE: 1/4" = 1''-0" N
FIRE ALARM PLAN - TOWER MAINTENANCE AREA LEVEL
SCALE: 1/4" = 1''-0"
TEMPORARILY DISCONNECT EXISTING FIRE ALARM
CIRCUITS AND HYDRAULIC POWER UNIT
INTERLOCK FROM EXISTING SPRINKLER SYSTEM
FLOW SWITCH & RECONNECT TO NEW FLOW
SWITCH. NEW FLOW SWITCH SHALL BE PROVIDED
WITH AUXILIARY CONTACTS FOR INTERLOCK WITH
HYDRAULIC POWER UNIT.
PENSACOLA, FLORIDA 32502
75 SOUTH "F" STREET
PETERSON ENGINEERING INC.
FA-102
N
ELECTRICAL PLAN - EQUIPMENT BUILDING
SCALE: 1/4" = 1''-0"
EXISTING PANEL "DP-EM"
EXISTING MAIN SWITCHBOARD "SE"
EXISTING PANEL "DP-N"
EXISTING PANEL "RP-EM-ER"
EXISTING PANEL "LP-EM-ER"
EXISTING PANEL "RP-ER"
HOMERUN 2 # 10 & 1 # 10 GND. - 3/4" C. TO NEW 30 A., 2 P. BKR. IN
EXISTING PANEL "RP-EM-ER." REMOVE EXISTING 20 A., 2 P. SPARE
BKR. & INSTALL NEW BREAKER IN EXISTING PANEL.
T
NEW HEAT TRACE TEMPERATURE
SENSOR - SEE "HEAT TRACE
RISER DIAGRAM," THIS SHEET.
HEAT TRACE POWER CONNECTOR -
FURNISHED BY MECHANICAL CONTRACTOR.
HEAT TRACE CONTROLLER W/ INTEGRAL
GROUND FAULT CIRCUIT PROTECTION -
SUPPLIED BY MECHANICAL CONTRACTOR.
HOMERUN 2 # 10 & 1 # 10 GND. - 3/4" C. TO NEW 30 A., 2 P. BKR. IN
EXISTING PANEL "RP-EM-ER." REMOVE EXISTING 20 A., 2 P. SPARE
BKR. & INSTALL NEW BREAKER IN EXISTING PANEL.
HEAT TRACE POWER JUNCTION BOX -
FURNISHED BY MECHANICAL CONTRACTOR.
3/4" FIBERGLASS CONDUIT W/ WIRING
SUPPLIED BY MECHANICAL CONTRACTOR.
FLOOR
HEAT TRACE POWER RISER DIAGRAM
N.T.S.
APPROXIMATE LOCATION OF HEAT TRACE POWER
JUNCTION BOX BELOW EQUIPMENT BUILDING FLOOR.
COORDINATE EXACT LOCATION W/ MECHANICAL
CONTRACTOR PRIOR TO ROUGHING IN CONDUIT.
ELECTRICAL LEGEND:
J
J
EXISTING PANELBOARD - TO REMAIN.
EXISTING JUNCTION BOX - TO REMAIN.
NEW JUNCTION BOX - 4" SQUARE, UNLESS NOTED OTHERWISE.
NEW CONDUIT & WIRING - AS DESCRIBED ON PLANS.
EXISTING PANEL "RP-EM-EL"
REMOVE EXISTING HEAT TRACE PUSHBUTTON
STATION & POWER CONDUIT & WIRING BACK
TO EXISTING 20 A., 2 P. BREAKER IN PANEL
"RP-EM-EL."
N
ELECTRICAL PLAN - TOWER EQUIPMENT AREA LEVEL
SCALE: 1/4" = 1''-0"
T
3/4" FIBERGLASS CONDUIT W/ WIRING
SUPPLIED BY MECHANICAL CONTRACTOR.
NEW HEAT TRACE
TEMPERATURE SENSOR
E-101
PENSACOLA, FLORIDA 32502
75 SOUTH "F" STREET
PETERSON ENGINEERING INC.
| FTFA 17-1109_FINAL |
| FTFA 17-1109 Drawings Final |
| 17152FP001-- |
| Sheets and Views |
| 17152FP001-- |
| 17152FP101-- |
| Sheets and Views |
| 17152FP101-- |
| 17152FP102-- |
| Sheets and Views |
| 17152FP102-- |
| 17152FP103-- |
| Sheets and Views |
| 17152FP103-Work |
| 17152FP104- |
| Sheets and Views |
| 17152FP104-Work |
| 17152FP105-- |
| Sheets and Views |
| 17152FP105-- |
| 17152FP106-- |
| Sheets and Views |
| 17152FP106-- |
| 17152FP107-- |
| Sheets and Views |
| 17152FP107-- |
| 17152FP501- |
| Sheets and Views |
| 17152FP501-Work |
| 17152 FA101-FA101 |
| Sheets and Views |
| 17152 FA101-FA101 |
| 17152 FA102-FA102 |
| Sheets and Views |
| 17152 FA102-FA102 |
| 17152 E101-E101 |
| Sheets and Views |
| 17152 E101-E101 |
File details come from the government source that posted it.