2_-_DBEH_10-1765_-_Repair_Generators_CCAFS_Drawings.pdf
PDF 3 MB Posted
- Solicitation number
- FA252119BA019
About this file
This pre-solicitation notice announces an anticipated Invitation for Bids for repair work at Cape Canaveral Air Force Station in Florida. Services include replacing generators at two buildings and upgrading electrical systems to provide redundant power sources. The acquisition is set aside for Service-Disabled Veteran-Owned Small Businesses. The solicitation number is FA252119BA019 and will be available on August 7, 2019. The performance period is 230 calendar days beginning within 10 days of notice to proceed. The Naval Facilities Engineering Command will award a firm-fixed-price construction contract. Interested parties should register at www.fbo.gov to receive procurement announcements. Questions must be submitted by email with the solicitation number to the points of contact listed by the specified due date.
Attachment 2 Project Drawings
View the file
Other files
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
S
K
I
D
T
R
I
P
B
A
N
R
V
E
L
C
O
PORT CANAVERAL
CCAFS
INDUSTRIAL AREA
TO
KENNEDY SPACE CENTER
INDUSTRIAL AREA
SOUTH GATE
PASS & ID
STATE RD 401
B
A
S
PATROL RD S
H O
U N
D
D
G
R
C L E
M
A
S
P
S
A
M
U
H
I L
L
I
W
Y
L
IG
H T
H O
U S
E R
D
S K
Y B
O
B
U
M
P
P
I
F S
A
R D
M
I S
S
I
N
T
R
F
L
I
G
N
T
R
I
R
M
L
IG
H T
H O
U S
E R
D
L
I
G
H
T
H
O
U
O
B
S
E
R
V
A
T
I
C
A
M
E
P
H
A
C
O
N
T
R
W
C
A
M
E
A
V
O
T
I
M
I
C
E
N
T
R
N
T
R
A
R
M
O
Y
A
Z
U
S
K
R
E
R
C
U
M
I
C
E
N
T
R
N
T
R
S A
M U
E L
I
N
D
U
S
T
H
A
N
G
T
I
T
N
A
W
I
T
T
E
I
C
F
R
E
E
D
B
E
A
PATROL RD
S A
M U
E
I L L I P
S
P
K W
Y
T
I T
I
R
D
C
E
N
T
A
U
R
O
C
K
S
A
M
U
I
L
L
I
W
Y
BO
UNDARY RD
P
I
H
E
A
U
N
F L I G
H
T
C
O
N
T R
O
L
R
D
P
I
OLD
SPIN TEST
FACILITY
MSA #5
CAMERA
PAD #21
SR 528 BEACHLINE
SR A1A TO COCOA BEACH
FSA #1
C
P
H
I L
L
I P
S
P
K
W
Y
HGR
C
LIGHT
HOUSE
STATE RD 401
CAPE CANAVERAL AIR FORCE STATION
DBEH 10-1765
CAPE CANAVERAL, FLORIDA
REPAIR GENERATORS,
CCAFS (LET)
BASE OPERATIONS:
COMMUNICATIONS:
PROJECT MANAGER:
CHIEF, ENGINEERING FLIGHT:
USER:
SAFETY:
SECURITY FORCES:
ATO:
OTHER:
ENVIRONMENTAL:
FIRE:
A
P
P
R
O
V
E
D
G-001
G
N
E U
H A
U S
L
C
O L E
M A
N
L O
C A
T I O
N
M
A P
P
R O
J E
E
D
D R
A W
I N
G
I N
D E
X
C
H
A R
T N
E T
T
D B
G
B
E A
R D
R E
P A
N
E R
A T
O R
S
C
C A
F
E T
D B
C C
A F
S
F
L U
S A
F
T
H
C
I V
I L
E
N G
I N
E E
R
S
Q U
A D
R O
N
I
T
E
D E
L I V
E R
Y
N
O
D R
A W
N
B
Y
D E
S I G
N E
D
B
Y
S U
B M
I T
T E
D
B
Y
R E
V I E
W E
D
B
Y
D A
T E
SHEET
IDENTIFICATION
C O
N T
R A
F
A
E I S
R A
N G
E
A
R C
H I T
E C
T E
N G
I N
E E
R
I N
S P
E C
T I O
N
S
E R
V I C
E S
F A
F n g i n e e r i n g I n c
L L
E N
E A
A
B
2 3
C
1 2 3
4 5
4 5
C
D
A
B
D
An O ne id a N at io n Co m pa ny
SCALE:
LOCATION MAP
NONE
PROJECT
AREA
PERMIT(S)/ENVIRONMENTAL ACTIONS
REQUIRED PRIOR TO CONSTRUCTION
ERP/STORMWATER
ERP/WETLANDS/DREDGE & FILL
FDEP/DRINKING WATER
FDEP/DOM. WASTE WATER ARCHEO./HISTORICAL
SURVEY/WILDLIFE
OTHER
NONE
FDEP/IND. WASTE WATER
IRP
FDEP/FUEL TANK
NOI/SWPPP
ASBESTOS
NOTE: IF IT IS SUSPECTED THAT ANY HAZARDOUS MATERIAL NOT
IDENTIFIED ON THESE DRAWINGS IS REQUIRED TO BE DISTURBED IN
ORDER TO PERFORM THE CONTRACT WORK, LEAVE MATERIAL
UNDISTURBED AND IMMEDIATELY INFORM THE CONTRACTING OFFICER.
HEAVY METALS
YES NO
LEAD
PCB
NOT
VERIFIED
HAZARDOUS MATERIALS
N
DRAWING INDEX
Sheet Number Sheet Title
GENERAL
G-001
LOCATION MAP, PROJECT AREAS AND DRAWING INDEX
HAZARDOUS MATERIALS
H-001
GENERAL HAZMAT NOTES, ABBREVIATIONS AND APPLICABLE CODES
H-101 HAZARDOUS MATERIALS PLAN - BLDG 54800 CHEM LAB
H-102 HAZARDOUS MATERIALS PLAN - BLDG 50225 RUNWAY VAULT
ELECTRICAL
E-001
ELECTRICAL NOTES, LEGEND AND ABBREVIATIONS
ED-101 ELECTRICAL PLAN - SITE 54800 - DEMOLITION
ED-102 ELECTRICAL PLAN - SITE 50225 - DEMOLITION
E-101 ELECTRICAL PLAN - SITE 54800 - NEW CONSTRUCTION
E-102 ELECTRICAL PLAN - SITE 50225 - NEW CONSTRUCTION
E-501
ELECTRICAL DETAILS
E-502
ELECTRICAL DETAILS
E-601 SINGLE-LINE DIAGRAM - SITE 54800
E-602 SINGLE-LINE DIAGRAM - SITE 50225
SCALE:
ENLARGED VIEW - BLDG 54800
NONE
N
S
C
R
J
54800
SCALE:
ENLARGED VIEW - BLDG 50225
NONE
R
50225
50216
50211
PROJECT
AREA
ABBREVIATIONS:
45 CES - 45TH CIVIL ENGINEERING SQUADRON
45 SW - 45TH SPACE WING
ACM - ASBESTOS CONTAINING MATERIAL
ACT - ACOUSTIC CEILING TILE
AFF - ABOVE FINISHED FLOOR
ALUM - ALUMINUM
ANOD - ANODIZED
BLDG - BUILDING
CFR - CODE OF FEDERAL REGULATIONS
CONC - CONCRETE
CONT - CONTINUOUS
CMDR - COMMANDER'S
CMU - CONCRETE MASONRY UNIT
CPT - CARPET
CT - CERAMIC TILE
DN - DOWN
DWGS - DRAWINGS
EPA - ENVIRONMENTAL PROTECTION AGENCY
ETR - EXISTING TO REMAIN
EXIST - EXISTING
EXT - EXTERIOR
F.A.C. - FLORIDA ADMINISTRATIVE CODE
F.G. - FIBERGLASS
FDEP - FLORIDA DEPARTMENT OF
ENVIRONMENTAL PROTECTION
FIN FL - FINISH FLOOR
F.V. - FIELD VERIFY
GA - GAUGE
GALV - GALVANIZED
GC - GENERAL CONTRACTOR
GRT - GROUT
GYP BD/GWB - GYPSUM WALL BOARD
H.M. - HOLLOW METAL
HAZMAT - HAZARDOUS MATERIALS
HW/HDW - HARDWARE
INSUL - INSULATION
INT - INTERIOR
MAX - MAXIMUM
MFR - MANUFACTURER
MIN - MINIMUM
M.O. - MASONRY OPENING
MTL - METAL
MRGWB - MOISTURE RESIST GYPSUM WALL BOARD
MTD - MOUNTED
NOM - NOMINAL
O.C. - ON CENTER
O.D. - OUTSIDE DIAMETER
OSHA - OCCUPATIONAL SAFETY AND HEALTH
ADMINISTRATION
PEL - PERMISSIBLE EXPOSURE LIMITS
P/PT - PAINT
P.T. - PRESSURE TREATED
PCB - POLYCHLORINATED BIPHENYLS
PLYWD - PLYWOOD
PL - PLASTIC LAMINATE
PLST - PLASTER
PPE - PERSONAL PROTECTIVE EQUIPMENT
PSI - POUNDS PER SQUARE INCH
PTS - POINTS
PVC - POLYVINYL CHLORIDE
REINF - REINFORCED
R.S. - RUBBER STRINGER
RTNR - RUBBER TREAD/NOSE/RISER
S.C. - SOLID CORE
SCHED/SCH - SCHEDULE
SDS - SAFETY DATA SHEETS
SMS - SHEET METAL SCREW
S.S. - SOLID SURFACE
ST. STL. - STAINLESS STEEL
TBB - TILE BACKER BOARD
TYP - TYPICAL
U.O.N. - UNLESS OTHERWISE NOTED
VWB - VINYL WALL BASE
VAT - VINYL ASBESTOS TILE
PROJECT SPECIFIC NOTES
1. GC SHALL COORDINATE DUST AND EQUIPMENT COVER INSTALLATION WITH
CONTRACTING OFFICER AND WITH FACILITY USER; EXISTING FACILITY FUNCTION
SHALL NOT BE COMPROMISED.
GENERAL HAZARDOUS MATERIAL NOTES:
REFER TO HAZMAT SPECIFICATIONS FOR ADDITIONAL INSTRUCTIONS.
NOTES: CONTRACTOR SUPPLIED MATERIALS:
1. THE CONTRACTOR SHALL COMPLY WITH, BUT NOT LIMITED TO: AFI 32-7086, HAZARDOUS MATERIALS MANAGEMENT, FEBRUARY 2015 AND THE 45TH SW HAZMAT TRACKING PROCEDURES FOR CONSTRUCTION AND SERVICE CONTRACTORS. NO
HAZARDOUS MATERIALS ARE ALLOWED TO BE BROUGHT ON TO ANY 45 SW INSTALLATION WITHOUT PRIOR APPROVAL. THE
CONTRACTOR SHALL CONTACT THE CONTRACTING OFFICER TO REVIEW HAZARDOUS MATERIALS AUTHORIZATION
PROCEDURES PRIOR TO HAZARDOUS MATERIALS BEING BROUGHT ON TO 45 SW FACILITIES. ALL CONSTRUCTION MATERIALS
REJECTED BY THE GOVERNMENT SHALL BE REMOVED FROM THE SITE IMMEDIATELY.
2. IF PRODUCTS ARE TO BE USED DURING THE PROJECT WHICH MAY CONTAIN HAZARDOUS CHEMICALS, THE SDS FOR THOSE
PRODUCTS SHALL BE SUBMITTED TO THE CONTRACTING OFFICER FOR REVIEW TO DETERMINE PERSONAL PROTECTIVE
EQUIPMENT REQUIREMENT FOR PERSONNEL USING PRODUCTS ALONG WITH GC'S SAFETY PLAN, PRIOR TO START OF WORK.
NOTES: HAZARDOUS MATERIALS ABATEMENT:
3. ABATEMENT CONTRACTOR IS RESPONSIBLE FOR VISITING THE SITE PRIOR TO PROVIDING BIDS FOR CONDUCTING
ABATEMENT WORK.
4. THERE SHALL BE NO HAZARDOUS AIR EMISSIONS FROM DEBRIS PER 29 CFR 1910. ANY SANDBLASTING OR NEEDLE-JET
OPERATIONS MUST BE APPROVED BY THE CONTRACTING OFFICER AND SHOULD HAVE FULL CONTAINMENT.
5. THE GC SHALL UTILIZE ASBESTOS AND HEAVY METALS SURVEY REPORTS ATTACHED TO THE SPECIFICATIONS IN ORDER TO
COMPLETE THE SCOPE OF WORK PER THE DRAWINGS AND SPECIFICATIONS. THE GC SHALL CONTACT THE CONTRACTING
OFFICER IF THE PRESENCE OF MATERIALS CONTAINING ACM, PCB OR HEAVY METALS, INCLUDING LEAD, CADMIUM, OR
CHROMIUM, IS SUSPECTED OR DISTURBED, AND HAS NOT BEEN IDENTIFIED BY THIS CONTRACT, BUT IS REQUIRED TO BE
DISTURBED IN ORDER TO:
· PERFORM THE CONTRACT WORK;
· SAFELY ACCESS THE AREA OF WORK WITHOUT EXPOSURE TO HAZMAT ABOVE THE PEL;
· HAVE WORKERS PERFORM THE CONTRACT WORK WITHOUT EXPOSURE TO HAZMAT ABOVE PEL.
UNDER NO CIRCUMSTANCES SHALL ANY MATERIALS CONTAINING HEAVY METALS OR ASBESTOS BE REMOVED WITHOUT THE
CONTRACTING OFFICER APPROVAL.
6. PREPARATION OF BUILDING SURFACES MAY CREATE DISTURBANCES OF NON-FRIABLE ACM. CAUTION MUST BE UTILIZED
DURING THE SUBJECT PREPARATIONS TO ENSURE THAT DAMAGE/DISTURBANCE TO ACM DOES NOT OCCUR. COATING OF
THE SUBJECT SURFACES SHALL BE PERFORMED IN ACCORDANCE WITH THE TRAINING AND HANDLING REQUIREMENTS OF 29
CFR 1926.1101 FOR CLASS II ASBESTOS WORK AND 29 CFR 1926.58, 40 CFR 763, HAZARDOUS WASTE MANAGEMENT PLAN, 45
SPACE WING, F.A.C. CHAPTER 62-257 AND FDEP FORM 62-257.900(1). FDEP FORM 62-257.900(1) (NOTICE OF DEMOLITION OR
ASBESTOS RENOVATION) MUST BE FORWARDED TO FDEP AT LEAST 10 DAYS PRIOR TO ACM REMOVAL.
7. THE REQUIREMENTS ESTABLISHED IN THE OSHA STANDARD FOR LEAD, CADMIUM AND CHROMIUM IN CONSTRUCTION, 29 CFR
1926.62, 29 CFR 1926.1127 AND 29 CFR 1926.1126, RESPECTIVELY, MUST BE COMPLIED WITH FOR ANY CONSTRUCTION, REFURBISHMENT, OR DEMOLITION OPERATIONS WHICH INVOLVES THE DISTURBANCE OF COATINGS WHICH MAY CONTAIN
HEAVY METALS. THE LEAD, CADMIUM AND CHROMIUM STANDARDS ESTABLISH SPECIFIC PERSONAL PROTECTIVE EQUIPMENT
TO INCLUDE RESPIRATORY PROTECTION BASED ON THE TYPE OF WORK TO BE PERFORMED (SEE SPECIFICATIONS FOR
ADDITIONAL DATA).
8. IF HEAVY METALS, INCLUDING LEAD, AND/OR PCB EXIST IN PAINTED SURFACES, THERE WILL BE CONCERNS ABOUT
PARTICULATE MATTER IN RINSATE AND ABOUT LEACHABILITY AND IMPACTS TO SURROUNDING ENVIRONMENTS. NON-LIQUID
PCB MATERIAL SHOULD BE HANDLED IN ACCORDANCE WITH 40 CFR 761. GC SHALL PROVIDE A SUBMITTAL FOR AN
ENVIRONMENTAL WORK PLAN TO ADDRESS THE IDENTIFIED BEST MEANS OF PRACTICE BY THE QUALIFIED CONTRACTOR IN
COMPLIANCE WITH FDEP, EPA AND OSHA. ONLY THOSE PERSONNEL TRAINED IN ABATEMENT HANDLING AND DISPOSAL MAY
PERFORM WORK AND SHALL DO SO IN A MANNER THAT MINIMIZES GENERATION OF AIR-BORNE DEBRIS. WATER AND DEBRIS
SHALL BE COLLECTED, TESTED, MANAGED AND DISPOSED OF IN ACCORDANCE WITH FEDERAL, STATE AND AIR FORCE
REGULATIONS.
9. PERSONNEL WHO UTILIZE RESPIRATORY EQUIPMENT SHALL COMPLY WITH OSHA STANDARD 29 CFR 1910.134. THE
REQUIREMENTS FOR PROTECTION OF PERSONNEL DURING DISTURBANCE OF COATINGS CONTAINING HEAVY METALS APPLY
WHEN THE CONTENT HAS BEEN IDENTIFIED AS "LOW". OSHA STANDARD 29 CFR 1926.62 DOES NOT INDICATE A LEVEL OF
CONTENT LIMIT. IF LEAD IS PRESENT AT ANY LEVEL, THE STANDARD SHALL BE ADHERED. FOLLOW 45 SW GUIDANCE FOR THE
REMOVAL OF MATERIALS AND COATINGS CONTAINING HEAVY METALS.
10. THE HAZMAT DRAWINGS ARE REPRESENTATIONS OF LOCATIONS CONTAINING HAZMAT AT LEVELS MEETING OR EXCEEDING
REGULATORY LEVELS. THE GC IS REQUIRED TO SUBMIT A WORK PLAN FOR THE ABATEMENT OF ACM, HEAVY METALS AND
PCB, WHERE APPLICABLE, FOR THIS PROJECT.
11. THE GC SHALL PROVIDE CERTIFICATION OF MONITORED AIR AND TESTING RESULTS PRIOR TO START OF DEMOLITION WORK.
12. WHERE APPLICABLE, CONTRACTOR SHALL REFER TO SPECIFICATIONS FOR DISPOSAL OF ACM, HEAVY METALS AND PCB.
13. QUALIFIED CONTRACTOR SHALL COORDINATE REMOVAL OF HAZMAT WITH ENVIRONMENTAL WORK PLAN AND CONTRACTING
OFFICER PRIOR TO COMMENCEMENT OF WORK AND REPORT THE PRESENCE OF ANY OTHER SUSPICIOUS HAZMAT IN AREAS
OF WORK PRIOR TO START OF REMOVAL/DEMOLITION.
14. WORKERS SHALL UTILIZE RESPIRATORY PROTECTION PER 29 CFR 1910.134 AND 29 CFR 1926.1153 AGAINST SILICA AND
PARTICULATES WHEN DISTURBING CONCRETE DURING BUILDING RENOVATION AND REPAIR ACTIVITIES.
H-001
J
B
A R
T O
N
J
M
C G
A N
N
G E
N E
R A
L
H
A Z
M A
T
N
O T
E S
A
B B
R E
V I A
T I O
N S
A N
D
A
P P
L I C
A B
D
E S
C
H
A R
T N
E T
T
D B
G
B
E A
R D
R E
P A
N
E R
A T
O R
S
C
C A
E T
D B
C C
A F
S
F
L U
S A
F
T
H
C
I V
G
I N
E E
R
S
Q U
A D
R O
N
I
T
E
D E
L I V
E R
Y
N
O
D R
A W
N
B
Y
D E
S I G
N E
D
B
Y
S U
B M
I T
T E
D
B
Y
R E
V I E
W E
D
B
Y
D A
T E
SHEET
IDENTIFICATION
C O
N T
R A
F
A
F
R A
E I S
R A
N G
E
A
R C
H I T
E C
T E
N G
I N
E E
R
I N
S P
E C
T I O
N
S
E R
V I C
E S
F A
F n g i n e e r i n g I n c
L L
E N
E A
A
B
2 3
C
1 2 3
4 5
4 5
C
D
A
B
D
An O ne id a N at io n Co m pa ny
APPLICABLE CODES
WORK SHALL BE IN COMPLIANCE WITH THE LATEST REVISION OF THE FOLLOWING CODES AND WITH PROJECT
SPECIFICATIONS:
OSHA STANDARD FOR RESPIRATORY PROTECTION, 29 CFR 1910.134
OSHA STANDARD FOR HAZARDOUS WASTE COMMUNICATION, 29 CFR 1910.1200
OSHA STANDARD FOR GASES, VAPORS, FUMES, DUSTS AND MISTS, 29 CFR 1926.55
OSHA STANDARD FOR LEAD, 29 CFR 1926.62
OSHA STANDARD FOR ASBESTOS, 29 CFR 1926.1101
OSHA STANDARD FOR CHROMIUM (VI), HEXAVALENT CHROMIUM, 29 CFR 1926.1126
OSHA STANDARD FOR CADMIUM, 29 CFR 1926.1127
OSHA STANDARD FOR RESPIRABLE CRYSTALLINE SILICA, 29 CFR 1926.1153
2018 INTERNATIONAL BUILDING CODE
2015 INTERNATIONAL MECHANICAL CODE
ASBESTOS ABATEMENT, FLORIDA STATUTES CHAPTER 469
ASBESTOS PROGRAM, F.A.C. CHAPTER 62-257
2016 GENERAL BUILDING REQUIREMENTS UFC 1-200-01
HAZARDOUS WASTE MANAGEMENT PLAN, 45TH SPACE WING
NATIONAL EMISSION STANDARD FOR ASBESTOS, 40 CFR 61 SUBPART M
EPA STANDARD FOR PCB, 40 CFR 761
SYNTHETIC ORGANIC CONTAMINANTS MONITORING REQUIREMENTS, F.A.C. 62-550.516
NFPA 30, FLAMMABLE AND COMBUSTIBLE LIQUIDS CODE
NFPA 70, NATIONAL ELECTRICAL CODE
NFPA 111, STANDARD ON STORED ELECTRICAL ENERGY EMERGENCY AND STANDBY POWER SYSTEMS
109 107
130 129
126125124135117
121A
121 122
107115114
U G
E
U
G
E
U G
E
H-101
J
B
A R
T O
N
J
M
C G
A N
N
H A
Z A
R D
O U
S
M
A T
E R
I A
A
N
B
L D
G
C H
B
C
H
A R
T N
E T
T
D B
G
B
E A
R D
R E
P A
N
E R
A T
O R
S
C
C A
E T
D B
C C
A F
S
F
L U
S A
F
T
H
C
I V
G
I N
E E
R
S
Q U
A D
R O
N
I
T
E
D E
L I V
E R
Y
N
O
D R
A W
N
B
Y
D E
S I G
N E
D
B
Y
S U
B M
I T
T E
D
B
Y
R E
V I E
W E
D
B
Y
D A
T E
SHEET
IDENTIFICATION
C O
N T
R A
F
A
F
R A
E I S
R A
N G
E
A
R C
H I T
E C
T E
N G
I N
E E
R
I N
S P
E C
T I O
N
S
E R
V I C
E S
F A
F n g i n e e r i n g I n c
L L
E N
E A
A
B
2 3
C
1 2 3
4 5
4 5
C
D
A
B
D
An O ne id a N at io n Co m pa ny
24'16'6' 2'4' 0' 8'
GRAPHIC SCALE 1/8" = 1'-0"
SCALE:
HAZARDOUS MATERIALS PLAN - BLDG 54800 CHEM LAB
1/8" = 1'-0"
T
R
U
E
N
O
R
T
H
NORTH
PLAN
GENERAL NOTES:
1. WORKERS SHALL UTILIZE RESPIRATORY PROTECTION PER OSHA STANDARDS 29
CFR 1910.134 AND 29 CFR 1926.1153 AGAINST SILICA AND PARTICULATES WHILE
DEMOLISHING CONCRETE PADS AND DISTURBING WALL CMU.
2. ASBESTOS AND HEAVY METALS INFORMATION IS BASED ON THE FIELD SAMPLING
AND TESTING REPORT PROVIDED AS ATTACHMENT I TO THE SPECIFICATIONS.
CONTRACTOR SHALL FIELD VERIFY TEST RESULTS AS ACCURATE AND COMPLETE
PRIOR TO INITIATING WORK AND PERFORM ANY ADDITIONAL TESTING REQUIRED TO
SAFELY PERFORM WORK AND PROPERLY DISPOSE OF DEMOLITION MATERIALS.
SEE TABLE 1 FOR ASBESTOS RESULTS SCHEDULE. SEE TABLE 2 FOR HEAVY
METALS RESULTS SCHEDULE.
FLAG NOTES:
1. WHEN REMOVING GENERATORS, SUB-BASE FUEL TANK AND ASSOCIATED PIPING
AND EQUIPMENT, CONTRACTOR SHALL HANDLE AND DISPOSE OF ALL WASTE
PETROLEUM PRODUCTS IN ACCORDANCE WITH 40 CFR 260-279, FAC 62-730, FAC
62-762 AND THE 45 SW HAZARDOUS WASTE MANAGEMENT PLAN.
2. LEAD AND CHROMIUM HAVE BEEN DETECTED IN EXTERIOR PAINT AT BUILDING
54800. WHERE WALL PENETRATION IS REQUIRED TO COMPLETE THE REPAIR, WORK
SHALL BE CONDUCTED IN SUCH A MANNER AS TO AVOID GENERATING PAINT DUST.
WORKERS SUBJECT TO EXPOSURE TO LEAD AND CHROMIUM IN PAINT SHALL
COMPLY WITH 29 CFR 1926.62, OSHA STANDARD FOR LEAD AND 29 CFR 1926.1126,
OSHA STANDARD FOR CHROMIUM.
G E
N E
R A
T O
R
P A
D
Facility 54800, AF Chem Lab, CCAFS Asbestos Containing Materials Results
Sample ID Material Type
Asbestos
Sample Date
Test Date
B54800-A02 Inner Generator Concrete Pad No 12/15/2017 12/15/2017
B54800-A03 Outer Generator Concrete Pad No 12/15/2017 12/15/2017
B54800-A04 Sidewalk Concrete No 12/15/2017 12/15/2017
B54800-A05 CMU Wall No 12/15/2017 12/15/2017
B54800-A06 Exterior Stucco No 12/15/2017 12/15/2017
B54800-A07 Elec Room Joint Compound No 12/15/2017 12/15/2017
B54800-A08 Elec Room Drywall No 12/15/2017 12/15/2017
Facility 54800, AF Chem Lab, CCAFS Heavy Metals Results
Sample ID Material Type
Barium Chromium Lead
Sample Date
Test Date
B54800-P01 Exterior Paint/Stucco 14.1 ppm 6.13 6.4 12/15/2017 12/19/2017
B54800-P02 Elec Room Wall Paint 13.2 ppm ND ND 12/15/2017 12/19/2017
TABLE 1 - ASBESTOS RESULTS SCHEDULE
TABLE 2 - HEAVY METALS RESULTS SCHEDULE
XFMR PAD
ETR
T
B
LP LP-1
GENERATOR
CU
CU
EXISTING
MANHOLE
S W
G R
U P
S
CONCRETE PAD - ETR
XFMR 'SKSI' - ETR
F
A T
S
300 GAL
DIESEL
FUEL TANK
CONCRETE
PADS - ETR
600A
208V
J
B
A R
T O
N
J
M
C G
A N
N
H A
Z A
R D
O U
S
M
A T
E R
I A
A
N
B L
N
W A
Y
V
A U
L T
C
H
A R
T N
E T
T
D B
G
B
E A
R D
R E
P A
N
E R
A T
O R
S
C
C A
E T
D B
C C
A F
S
F
L U
S A
F
T
H
C
I V
G
I N
E E
R
S
Q U
A D
R O
N
I
T
E
D E
L I V
E R
Y
N
O
D R
A W
N
B
Y
D E
S I G
N E
D
B
Y
S U
B M
I T
T E
D
B
Y
R E
V I E
W E
D
B
Y
D A
T E
SHEET
IDENTIFICATION
C O
N T
R A
F
A
F
R A
E I S
R A
N G
E
A
R C
H I T
E C
T E
N G
I N
E E
R
I N
S P
E C
T I O
N
S
E R
V I C
E S
F A
F n g i n e e r i n g I n c
L L
E N
E A
A
B
2 3
C
1 2 3
4 5
4 5
C
D
A
B
D
An O ne id a N at io n Co m pa ny
12'8'4'1'2' 0'
GRAPHIC SCALE 1/4" = 1'-0"
SCALE:
HAZARDOUS MATERIALS PLAN - BLDG 50225 RUNWAY VAULT
1/4" = 1'-0"
T R
U E
N O
R T
H
NORTH
PLAN
GENERAL NOTES:
1. WORKERS SHALL UTILIZE RESPIRATORY PROTECTION PER OSHA
STANDARDS 29 CFR 1910.134 AND 29 CFR 1926.1153 AGAINST SILICA AND
PARTICULATES WHILE DEMOLISHING CONCRETE PADS AND DISTURBING
WALL CMU.
2. ASBESTOS AND HEAVY METALS INFORMATION IS BASED ON THE FIELD
SAMPLING AND TESTING REPORT PROVIDED AS ATTACHMENT I TO THE
SPECIFICATIONS. CONTRACTOR SHALL FIELD VERIFY TEST RESULTS AS
ACCURATE AND COMPLETE PRIOR TO INITIATING WORK AND PERFORM ANY
ADDITIONAL TESTING REQUIRED TO SAFELY PERFORM WORK AND
PROPERLY DISPOSE OF DEMOLITION MATERIALS. SEE TABLE 3 FOR
ASBESTOS RESULTS SCHEDULE.
FLAG NOTE:
1. WHEN REMOVING GENERATORS AND ASSOCIATED PIPING AND EQUIPMENT,
CONTRACTOR SHALL HANDLE AND DISPOSE OF ALL WASTE PETROLEUM
PRODUCTS IN ACCORDANCE WITH 40 CFR 260-279, FAC 62-730, FAC 62-762
AND THE 45 SW HAZARDOUS WASTE MANAGEMENT PLAN.
H-102
TABLE 3 - ASBESTOS RESULTS SCHEDULE
Facility 50225, Skid Strip UPS Building, CCAFS Asbestos Containing Materials Results
Sample ID Material Type
Asbestos
Sample Date
Test Date
B50225-A01 Concrete Generator Pad No 12/15/2017 12/15/2017
E-001
G
B
O G
I A
T Z
I D
I S
L
C
O L E
M A
N
E L
E C
T R
I C
T
E S
L
E G
E N
D
A
N D
A B
B R
E V
I A
T I O
N S
C
H
A R
T N
E T
T
D B
G
B
E A
R D
D B
C C
A F
S
F
L U
S A
F
T
H
C
I V
G
I N
E E
R
S
Q U
A D
R O
N
I
T
E
D E
L I V
E R
Y
N
O
D R
A W
N
B
Y
D E
S I G
N E
D
B
Y
S U
B M
I T
T E
D
B
Y
R E
V I E
W E
D
B
Y
D A
T E
SHEET
IDENTIFICATION
C O
N T
R A
F
A
F
R A
E I S
R A
N G
E
A
R C
H I T
E C
T E
N G
I N
E E
R
I N
S P
E C
T I O
N
S
E R
V I C
E S
F A
F n g i n e e r i n g I n c
L L
E N
E A
A
B
2 3
C
1 2 3
4 5
4 5
C
D
A
B
D
An O ne id a N at io n Co m pa ny
R E
P A
N
E R
A T
O R
S
C
C A
E T
BRANCH CIRCUIT CONDUIT RUN. ARROW
INDICATES HOME RUN, MINIMUM CONDUIT SIZE
SHALL BE 3/4". HOME RUNS LONGER THAN 100'
SHALL USE #10 CONDUCTOR (MIN).
ABOVE GROUND ELECTRICAL CONDUIT
LIGHTNING #2/0 BARE COPPER CONDUCTOR
GROUNDING CONDUCTOR, BELOW GRADE
208/120V PANELBOARD
TRANSFORMER (LOW VOLTAGE)
GROUND ROD WITH EXOTHERMIC WELD
CONNECTION
24" AIR TERMINAL
GROUNDING TEST WELL WITH GROUND ROD
LP
G
A - AMPERES, AMPS
AASHTO - AMERICAN ASSOCIATION OF
STATE HIGHWAY &
TRANSPORTATION OFFICIALS
AFG - ABOVE FINISHED GRADE
AIC - AMPS INTERRUPTING CAPACITY
ANN - ANNUNCIATOR
ATS - AUTOMATIC TRANSFER SWITCH
AUX - AUXILIARY
BFF - BELOW FINISHED FLOOR
BFG - BELOW FINISHED GRADE
BRKR - BREAKER
BSD - BARE SOFT DRAWN
C - CONDUIT
CB - CIRCUIT BREAKER
CKT - CIRCUIT
CMU - CONCRETE MASONRY UNIT
CONC - CONCRETE
CU - COPPER
DIA - DIAMETER
DISC - DISCONNECT
DWG - DRAWING
ECS - ENVIRONMENTAL CONTROL SHELTER
ELEC - ELECTRIC
EMT - ELECTRICAL METALLIC TUBING
EQPM - EQUIPMENT
EXH - EXHAUST
EXST - EXISTING
FACP - FIRE ALARM CONTROL PANEL
GFCI - GROUND FAULT CIRCUIT INTERRUPTER
GND - GROUND
IAW - IN ACCORDANCE WITH
ID - INSIDE DIAMETER
KCMIL - THOUSAND CIRCULAR MILS
KV - KILOVOLTS
KW - KILOWATT
MTR - MOTOR
MTS - MANUAL TRANSFER SWITCH
N/A - NOT APPLICABLE
NC - NORMALLY CLOSED
NESHAP - NATIONAL EMISSIONS STANDARDS
FOR HAZARDOUS AIR POLLUTANTS
NIC - NOT IN CONTRACT
NO - NORMALLY OPEN
NTS - NOT TO SCALE
OC - ON CENTER
OD - OUTSIDE DIAMETER
Ø - PHASE
PNL - PANEL/PANELBOARD
PVC - POLYVINYL CHLORIDE
QTY - QUANTITY
REF - REFERENCE
RGS - RIGID GALVANIZED STEEL
RICE - RECIPROCATING INTERNAL
COMBUSTION ENGINE
SWBD - SWITCHBOARD
TMCB - THERMAL MAGNETIC CIRCUIT BREAKER
TTB - TELEPHONE TERMINAL BOARD
TYP - TYPICAL
UG - UNDERGROUND
UGE - UNDERGROUND ELECTRIC
UON - UNLESS OTHERWISE NOTED
UPS - UNINTERRUPTIBLE POWER SUPPLY
V - VOLTS
W - WATTS
WWF - WELDED WIRE FRAME
XFMR - TRANSFORMER
SEQUENCE OF CONSTRUCTION FOR 54800 GENERATOR AND
AUTOMATIC TRANSFER SWITCH INSTALLATION:
THE CONTRACTOR SHALL SUBMIT A PROPOSED SEQUENCE OF CONSTRUCTION FOR
APPROVAL. SEQUENCE OF CONSTRUCTION SHALL COMPLY WITH THE FOLLOWING
GUIDELINES:
1. NOTIFY THE 45TH SPACE WING ENVIRONMENTAL OFFICE 14 DAYS PRIOR TO THE START
OF CONSTRUCTION.
2. PROVIDE A 125 KW TEMPORARY GENERATOR WITH 24 HOUR FUEL TANK AND A
TEMPORARY AUTOMATIC TRANSFER SWITCH TO FEED PANEL 'EDP' PROVIDE
TEMPORARY CONDUCTORS AS REQUIRED.
3. ALL THE NECESSARY PERSONNEL, TOOLS, AND MATERIAL REQUIRED FOR THE WORK
BEING DONE THAT DAY SHALL BE ON SITE PRIOR TO STARTING WORK.
4. MAXIMUM OUTAGE TIME SHALL NOT EXCEED 4 HOURS. COORDINATE OUTAGE
REQUESTS WITH THE CONTRACTING OFFICER AT LEAST 14 WORKING DAYS IN ADVANCE
OF ANY OUTAGE.
5. GENERATOR AND AUTOMATIC TRANSFER SWITCH SHALL BE TESTED AND ACCEPTED
PRIOR TO CONNECTION OF LOADS.
T
G GENERATOR - SINGLE-LINE DIAGRAM
UNDERGROUND ELECTRICAL CONDUIT
ELECTRICAL NOTES:
1. IT IS THE INTENT OF THESE CONTRACT DRAWINGS TO PROVIDE A COMPLETE AND
WORKABLE FACILITY.
2. DESIGN DRAWINGS ARE DIAGRAMMATIC AND DO NOT SHOW ALL OFFSETS, BENDS,
ELBOWS, OR OTHER SPECIFIC ELEMENTS THAT MAY BE REQUIRED FOR PROPER
INSTALLATION OF THE WORK. SUCH WORK SHALL BE VERIFIED AT THE SITE.
ADDITIONAL BENDS, OFFSETS, AND CONDUIT AS REQUIRED BY VERTICAL AND
HORIZONTAL EQUIPMENT LOCATIONS OR OTHER JOB CONDITIONS, SHALL BE
PROVIDED TO COMPLETE THE WORK AT NO ADDITIONAL COST TO THE GOVERNMENT.
3. EXCEPT WHERE SHOWN IN DIMENSIONAL DETAIL, THE LOCATIONS OF EQUIPMENT
SHOWN ON PLANS ARE APPROXIMATE. SUCH ITEMS SHALL BE PLACED TO ELIMINATE
INTERFERENCE WITH OTHER EQUIPMENT. THE EXACT LOCATIONS SHALL BE
DETERMINED IN THE FIELD.
4. ALL WORK SHALL BE IN ACCORDANCE WITH THE 2017 EDITION OF THE NATIONAL
ELECTRICAL CODE (NFPA 70).
5. MATERIALS SHALL BE LISTED BY THE UNDERWRITER'S LABORATORIES, INC. OR
ANOTHER APPROVED/CERTIFIED TESTING LABORATORY. SHOULD PLANS AND CODES
CONFLICT, CONTACT THE CONTRACTING OFFICER. MAKE NO CHANGES, EVEN IN CASE
OF CONFLICT, WITHOUT FIRST OBTAINING THE APPROVAL OF THE CONTRACTING
OFFICER.
6. A GREEN, COPPER GROUND WIRE SHALL BE INSTALLED IN ALL CONDUIT SYSTEMS AND
SHALL BE BONDED TO ALL ENCLOSURES, BOXES, AND EQUIPMENT. RECEPTACLES
WITH GREEN WIRE SHALL BE BONDED TO BOX THEN TO RECEPTACLE SUCH THAT
REMOVAL OF RECEPTACLE DEVICE SHALL NOT INTERRUPT GREEN WIRE BOND TO
METALLIC BOX OR ENCLOSURE.
7. BONDING JUMPERS SHALL BE USED TO BOND CONDUIT TO ENCLOSURES, BOXES, AND
EQUIPMENT WHERE CONCENTRIC OR ECCENTRIC KNOCKOUTS ARE USED.
8. EQUIPMENT SIZES INDICATED ARE MINIMUM, BEFORE INSTALLING ANY WIRE OR
CONDUIT, THE CONTRACTOR SHALL OBTAIN THE EXACT EQUIPMENT REQUIREMENTS
AND SHALL INSTALL WIRE, CONDUIT, CIRCUIT BREAKERS AND OTHER ITEMS OF THE
CORRECT SIZE FOR THE EQUIPMENT ACTUALLY INSTALLED. HOWEVER, WIRE AND
CONDUIT SIZES FOR THE EQUIPMENT SHALL BE TAKEN AS A MINIMUM AND SHALL NOT
BE REDUCED WITHOUT WRITTEN APPROVAL.
9. THE INSTALLATION OF THE ELECTRICAL WORK SHALL BE COORDINATED WITH THE
WORK OF THE OTHER TRADES.
10. 'PROVIDE', AS USED HERE ON THE DRAWINGS, IS AN ALL-INCLUSIVE TERM REQUIRING
CONTRACTOR TO FURNISH, INSTALL, WIRE, AND CONNECT ALL SPECIFIED EQUIPMENT
AS WELL AS COMPONENTS, ACCESSORIES, WIRING, AND MOUNTING HARDWARE TO
INSURE THAT SPECIFIED EQUIPMENT FUNCTIONS TO MEET SYSTEM(S) REQUIREMENTS.
11. WHERE NEW-TO-EXISTING CONNECTIONS ARE INDICATED, THE CONTRACTOR SHALL
PROVIDE ALL MATERIALS (JUNCTION BOXES, CONDUIT, WIRE, AND CONNECTIONS) AND
LABOR REQUIRED TO MAKE THE CONNECTIONS.
12. UNLESS OTHERWISE NOTED, ALL POWER CIRCUIT CONDUCTORS SHALL BE COPPER
AND MINIMUM #12AWG. CONDUITS SHALL BE 3/4" MINIMUM.
13. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROTECT EXISTING
UTILITIES FROM DAMAGE. THE CONTRACTOR SHALL BEAR ALL EXPENSE FOR REPAIR
OR REPLACEMENT OF THE UTILITIES OR OTHER PROPERTY DAMAGED BY OPERATIONS
IN CONJUNCTION WITH THE COMPLETION OF THIS WORK.
14. ALL BOLTS, NUTS, WASHERS, ETC. USED FOR GROUNDING AND BONDING
CONNECTIONS SHALL BE COPPER. CONTRACTOR SHALL UTILIZE CONNECTORS TO
PREVENT GALVANIC ACTION.
15. FINAL ACCEPTANCE WILL DEPEND UPON SATISFACTORY PERFORMANCE OF
EQUIPMENT. NO CONDUCTOR SHALL BE ENERGIZED UNTIL THE INSTALLATION HAS
BEEN APPROVED.
16. CONDUITS SHALL BE SUPPORTED BY SUITABLE CLAMPS, HANGERS OR STRAPS TO
PROVIDE A RIGID INSTALLATION. CONDUIT SUPPORTS SHALL NOT BE FASTENED OR
ATTACHED TO OTHER PIPES. PERFORATED STRAP HANGERS WILL NOT BE ALLOWED.
EMPTY CONDUIT SHALL BE THOROUGHLY SWABBED OUT WITH DRY SWAB TO REMOVE
MOISTURE AND DEBRIS BEFORE WIRE IS DRAWN IN. END OF CONDUIT SHALL BE
TIGHTLY PLUGGED UNTIL WIRE IS PULLED. NO CONDUIT SHALL BE LOCATED TO IMPAIR
THE STRENGTH OF STRUCTURAL MEMBERS. MAKE CHANGES IN DIRECTION OF RUNS
WITH SYMMETRICAL BENDS. MAKE FIELD MADE BENDS AND OFFSETS WITH HICKEY OR
CONDUIT BENDING MACHINE. DO NOT INSTALL CRUSHED OR DEFORMED CONDUITS.
AVOID TRAPPED CONDUITS. PREVENT PLASTER, DIRT, OR TRASH FROM LODGING IN
CONDUIT, BOXES, FITTINGS. FREE CLOGGED CONDUITS OF OBSTRUCTIONS.
17. IN ACCORDANCE WITH NFPA 70, GROUND EXPOSED, NON-CURRENT CARRYING
METALLIC PARTS OF ELECTRICAL EQUIPMENT, METALLIC RACEWAY SYSTEMS,
GROUNDING CONDUCTOR IN METALLIC RACEWAYS.
18. FASTEN CONDUITS TO SHEET METAL BOXES AND CABINETS WITH TWO LOCKNUTS
WHERE REQUIRED BY NFPA 70, WHERE INSULATED BUSHINGS ARE USED, AND WHERE
BUSHINGS CANNOT BE BROUGHT INTO FIRM CONTACT WITH THE BOX; OTHERWISE, USE
MINIMUM SINGLE LOCKNUT AND BUSHING. LOCKNUTS SHALL HAVE SHARP EDGES FOR
DIGGING INTO WALLS OF METAL ENCLOSURE. INSTALL BUSHINGS ON ENDS OF
CONDUITS, AND PROVIDE INSULATING TYPE WHERE REQUIRED BY NFPA 70.
19. PROVIDE AND INSTALL AT WALL OR FLOOR PENETRATIONS A PERMANENT FIRE STOP
SYSTEM. THE SYSTEM SHALL CONSIST OF A WATER BASED FIRE STOP COMPOUND AS
THE FILL, VOID, OR CAVITY MATERIAL ALONG WITH APPROPRIATE DAMMING MATERIAL
(AS PER MANUFACTURER'S INSTRUCTIONS). THE FIRE STOP COMPOUND SHALL NOT
CONTAIN ANY SOLVENTS, INORGANIC FIBERS, OR SILICONE COMPOUNDS AND SHALL
NOT REQUIRE HEAT TO ACTIVATE THE SEAL. THE FIRE STOP COMPOUND SHALL BE
ONE-PART MATERIALS, REQUIRING NO CRITICAL MIXING. THE PENETRATION SEAL
MATERIAL MUST BE UNAFFECTED BY MOISTURE AND MUST MAINTAIN THE INTEGRITY
OF THE FLOOR OR WALL ASSEMBLY FOR ITS RATED TIME PERIOD WHEN TESTED IN
ACCORDANCE WITH ASTM E84. THE SYSTEM SHALL BE UL CLASSIFIED AND INSTALLED
TO PROVIDE A 2 HOUR FIRE RATING. THE PENETRATION FIRE STOP MATERIAL SHALL
BE FLAME-SAFE FS1900 SERIES COMPOUND AS MANUFACTURED BY GRACE
CONSTRUCTION PRODUCTS OR EQUAL.
20. DAMAGE DONE TO ZINC COATING OF GALVANIZED CONDUIT, BOXES, AND FITTINGS,
INCLUDING EXPOSED CONDUIT THREADS AND ZINC FINISHES SCRATCHING, SHALL BE
REPAIRED BY CLEANING, PREPPING, AND COATING DAMAGED SURFACE WITH
INORGANIC ZINC COMPOUND.
21. PROVIDE ELECTRICAL CONDUIT AS FOLLOWS:
- RGS - ABOVE GRADE OUTSIDE, INSIDE WHERE SUBJECT TO PHYSICAL DAMAGE, OR
IN HAZARDOUS LOCATIONS
- EMT - ABOVE GRADE INSIDE WHERE NOT SUBJECT TO PHYSICAL DAMAGE
- PVC SCHEDULE 40 - BELOW GRADE WHERE NOT SUBJECT TO PHYSICAL DAMAGE
- PVC SCHEDULE 80 - BELOW GRADE WHERE SUBJECT TO PHYSICAL DAMAGE
22. EMT CONDUIT SHALL USE COMPRESSION FITTINGS. SET SCREW FITTINGS ARE NOT
ALLOWED.
TRANSFORMER (MEDIUM VOLTAGE)
APPLIES TO ALL ELECTRICAL SHEETS
ELECTRICAL LEGEND
ABBREVIATIONS:
APPLIES TO ALL ELECTRICAL SHEETS; SOME SYMBOLS MAY NOT BE USED.
DASHED SYMBOLS INDICATE DEMOLITION.
UGE
E
AUTOMATIC OR MANUAL TRANSFER SWITCH
- SINGLE-LINE DIAGRAM
480/277V PANELBOARD
ATS
AUTOMATIC TRANSFER SWITCH
ANNUNCIATOR - REMOTE
F
FIRE ALARM CONTROL PANEL - FACP
MANUAL TRANSFER SWITCH
MTS
FUSED SAFETY SWITCH/
FUSED DISCONNECT SWITCH
SEQUENCE OF CONSTRUCTION FOR 50225 GENERATOR
INSTALLATION:
THE CONTRACTOR SHALL SUBMIT A PROPOSED SEQUENCE OF CONSTRUCTION FOR
APPROVAL. SEQUENCE OF CONSTRUCTION SHALL COMPLY WITH THE FOLLOWING
GUIDELINES:
1. NOTIFY THE 45TH SPACE WING ENVIRONMENTAL OFFICE 14 DAYS PRIOR TO THE START
OF CONSTRUCTION.
2. PROVIDE A 250 KW TEMPORARY GENERATOR WITH 24 HOUR FUEL TANK. CONNECT
GENERATOR TO EXISTING AUTOMATIC TRANSFER SWITCH (ATS) LOCATED INSIDE
BUILDING. CONNECT GENERATOR FOR AUTO START USING SIGNAL FROM EXISTING 'ATS'.
3. ALL THE NECESSARY PERSONNEL, TOOLS, AND MATERIAL REQUIRED FOR THE WORK
BEING DONE THAT DAY SHALL BE ON SITE PRIOR TO STARTING WORK.
4. MAXIMUM OUTAGE TIME SHALL NOT EXCEED 4 HOURS. COORDINATE OUTAGE
REQUESTS WITH THE CONTRACTING OFFICER AT LEAST 14 WORKING DAYS IN ADVANCE
OF ANY OUTAGE.
5. GENERATOR AND AUTOMATIC TRANSFER SWITCH SHALL BE TESTED AND ACCEPTED
PRIOR TO CONNECTION OF LOADS.
SF
SILT FENCE
B
BATTERY CHARGER/MONITOR FOR GENERATOR
EXOTHERMIC WELD TO GROUNDING
COUNTERPOISE
ANN
EMERGENCY MAIN DISCONNECT
APPLICABLE CODES
WORK SHALL BE IN COMPLIANCE WITH THE LATEST REVISION OF THE FOLLOWING CODES AND WITH PROJECT SPECIFICATIONS:
NFPA 30, FLAMMABLE AND COMBUSTIBLE LIQUIDS CODE
NFPA 70, NATIONAL ELECTRICAL CODE
NFPA 111, STANDARD ON STORED ELECTRICAL ENERGY EMERGENCY AND STANDBY POWER SYSTEMS
E U
G E
U G
E
PNL 'MEP1'
PNL 'MEP2'
S W
P
E
T R
XFMR
'CHMI' - ETR
PNL 'LA'
PNL 'LB'
PNL 'ELP'
UGE
121A
F
PNL 'HA'
PNL 'LD'
PNL 'EDP'
B
A T
S
U
G
E
SF SF
S
F
ED-101
G
B
O G
I A
T Z
I D
I S
L
C
O L E
M A
N
E L
E C
T R
I C
A
N
S
I T
E
E
M O
L I T
I O
N
C
H
A R
T N
E T
T
D B
G
B
E A
R D
R E
P A
N
E R
A T
O R
S
C
C A
E T
D B
C C
A F
S
F
L U
S A
F
T
H
C
I V
G
I N
E E
R
S
Q U
A D
R O
N
I
T
E
D E
L I V
E R
Y
N
O
D R
A W
N
B
Y
D E
S I G
N E
D
B
Y
S U
B M
I T
T E
D
B
Y
R E
V I E
W E
D
B
Y
D A
T E
SHEET
IDENTIFICATION
C O
N T
R A
F
A
F
R A
E I S
R A
N G
E
A
R C
H I T
E C
T E
N G
I N
E E
R
I N
S P
E C
T I O
N
S
E R
V I C
E S
F A
F n g i n e e r i n g I n c
L L
E N
E A
A
B
2 3
C
1 2 3
4 5
4 5
C
D
A
B
D
An O ne id a N at io n Co m pa ny
24'16'6' 2'4' 0' 8'
GRAPHIC SCALE 1/8" = 1'-0"
T
R
U
E
N
O
R
T
H
NORTH
PLAN
GENERAL NOTES:
1. CONTRACTOR SHALL VERIFY EXISTING CONDITIONS PRIOR
TO ANY FABRICATION OR CONSTRUCTION.
2. DEVICE LOCATIONS AND CONDUIT/CONDUCTOR ROUTING
ARE DIAGRAMMATIC AND MAY DIFFER FROM FIELD
CONDITIONS.
FLAG NOTES:
1. DISCONNECT AND REMOVE EXISTING 50 KW GENERATOR WITH
SUB-BASE FUEL TANK, INCLUDING ASSOCIATED CONDUCTORS
AND JUNCTION BOX.
2. REMOVE EXISTING CONCRETE PAD AND CURBING.
3. EXISTING MANUAL TRANSFER SWITCH (MTS) FOR PORTABLE
GENERATOR CONNECTION SHALL REMAIN.
4. DISCONNECT AND REMOVE EXISTING UNDERGROUND ELECTRICAL
(UGE) WIRING - (4) #3, #8 GND IN 1-1/4" CONDUIT. ROUTING SHOWN
IS DIAGRAMMATIC. EXISTING CONDUIT SHALL HAVE END CAPPED
AND SHALL BE ABANDONED IN PLACE.
5. DISCONNECT AND REMOVE EXISTING AUTOMATIC TRANSFER
SWITCH (ATS), INCLUDING WIRING TO EXISTING SWITCHBOARD
'MP' AND EXISTING PANEL 'EDP'. UNDERGROUND CONDUIT TO
EXISTING SWBD 'MP' SHALL BE ABANDONED IN PLACE.
6. DISCONNECT AND REMOVE EXISTING GENERATOR BATTERY
CHARGER MOUNTED ABOVE 'ATS'. CHARGER FED FROM EXISTING
PANEL 'ELP', BRANCH CIRCUIT 17. RETAIN CIRCUIT FOR REUSE.
7. PROVIDE AND MAINTAIN EROSION CONTROL MEASURES. REFER
TO DETAIL 6 ON SHEET E-502 FOR ADDITIONAL INFORMATION.
8. EXISTING BOLLARDS SHALL REMAIN.
9. DISCONNECT GENERATOR JACKET HEATER CIRCUIT IN EXISTING
PANEL 'ELP', BRANCH CIRCUIT 13. RETAIN CIRCUIT FOR REUSE.
SCALE:
ELECTRICAL PLAN - SITE 54800 - DEMOLITION
1/8" = 1'-0"
E-502
T T
B
LP LP-1
GENERATOR
300 GAL
DIESEL
FUEL TANK
CU
CU
CONCRETE
PADS - ETR
CONCRETE PAD - ETR
S W
G R
U P
S
XFMR 'SKSI' - ETR
U
G
E
E
E
G
EXISTING
MANHOLE
A T
S
600A
208V
ED-102
G
B
O G
I A
T Z
I D
I S
L
C
O L E
M A
N
E L
E C
T R
I C
A
N
S
I T
E
E
M O
L I T
I O
N
C
H
A R
T N
E T
T
D B
G
B
E A
R D
R E
P A
N
E R
A T
O R
S
C
C A
E T
D B
C C
A F
S
F
L U
S A
F
T
H
C
I V
G
I N
E E
R
S
Q U
A D
R O
N
I
T
E
D E
L I V
E R
Y
N
O
D R
A W
N
B
Y
D E
S I G
N E
D
B
Y
S U
B M
I T
T E
D
B
Y
R E
V I E
W E
D
B
Y
D A
T E
SHEET
IDENTIFICATION
C O
N T
R A
F
A
F
R A
E I S
R A
N G
E
A
R C
H I T
E C
T E
N G
I N
E E
R
I N
S P
E C
T I O
N
S
E R
V I C
E S
F A
F n g i n e e r i n g I n c
L L
E N
E A
A
B
2 3
C
1 2 3
4 5
4 5
C
D
A
B
D
An O ne id a N at io n Co m pa ny
12'8'4'1'2' 0'
GRAPHIC SCALE 1/4" = 1'-0"
T R
U E
N O
R T
H
NORTH
PLAN
FLAG NOTES:
1. DISCONNECT AND REMOVE EXISTING 180 KW GENERATOR.
2. REMOVE EXISTING UNDERGROUND ELECTRICAL (UGE) CONDUCTORS TO
SAFETY SWITCH. REMOVAL OF 'UGE' SHALL AVOID EXISTING
COUNTERPOISE.
3. PARTIAL EXISTING COUNTERPOISE, GROUNDING TEST WELL AND GROUND
ROD SHOWN FOR REFERENCE.
4. DISCONNECT AND DISCARD GROUNDING CONDUCTOR AND POWER
CONDUCTORS FROM SAFETY SWITCH. EXISTING (2) CONDUIT STUB-UPS
INTO SAFETY SWITCH SHALL BE CUT TO TOP OF EXISTING CONCRETE SLAB
AND FILLED WITH GROUT. REMOVE EXISTING SAFETY SWITCH INCLUDING
SUPPORT STRUCTURE (NOT SHOWN).
5. REMOVE EXISTING ABOVE GROUND CONDUCTORS BETWEEN SAFETY
SWITCH AND GENERATOR BEING REMOVED.
6. EXISTING AUTOMATIC TRANSFER SWITCH (ATS) SHALL REMAIN.
7. EXISTING FUEL TANK SHALL REMAIN.
8. DISCONNECT EXISTING FUEL PIPING FROM GENERATOR BEING REMOVED.
REMOVE EXISTING PIPING ALONG GENERATOR CONCRETE PAD TO ALLOW
FOR REMOVAL OF GENERATOR. PIPING SHALL BE CAPPED AND PROTECTED
FROM DEMOLITION DEBRIS.
9. DISCONNECT GENERATOR JACKET/BLOCK HEATER IN EXISTING PANEL 'LP'.
RETAIN CIRCUIT FOR REUSE.
10. DISCONNECT GENERATOR BATTERY CHARGER IN EXISTING PANEL 'LP'.
RETAIN CIRCUIT FOR REUSE.
11. EXISTING 4" CONDUIT TO ATS. DEMO A SECTION OF THIS CONDUIT AT THE
DISCONNECT SWITCH AND RETAIN REMAINDER FOR
EXTENSION/REROUTING AS SHOWN ON SHEET E-102.
GENERAL NOTES:
1. CONTRACTOR SHALL VERIFY EXISTING CONDITIONS PRIOR TO ANY
FABRICATION OR CONSTRUCTION.
2. DEVICE LOCATIONS AND CONDUIT/CONDUCTOR ROUTING ARE
DIAGRAMMATIC AND MAY DIFFER FROM FIELD CONDITIONS.
SCALE:
ELECTRICAL PLAN - SITE 50225 - DEMOLITION
1/4" = 1'-0"
PNL 'LA'
PNL 'LB'
PNL 'ELP'
PNL 'MEP1'
PNL 'MEP2'
S W
P
E
T R
U G
E
C B
G E
N E
R A
T O
R
XFMR
'CHMI' - ETR
B
A T
S
121A 121
F
PNL 'HA'
PNL 'LD'
PNL 'EDP'
EDGE OF PAVEMENT
U
G
E
U G
E
SF SF
S
F
E-101
G
B
O G
I A
T Z
I D
I S
L
C
O L E
M A
N
E L
E C
T R
I C
A
N
S
I T
E
E W
C O
N S
T R
U C
T I O
N
C
H
A R
T N
E T
T
D B
G
B
E A
R D
R E
P A
N
E R
A T
O R
S
C
C A
E T
D B
C C
A F
S
F
L U
S A
F
T
H
C
I V
G
I N
E E
R
S
Q U
A D
R O
N
I
T
E
D E
L I V
E R
Y
N
O
D R
A W
N
B
Y
D E
S I G
N E
D
B
Y
S U
B M
I T
T E
D
B
Y
R E
V I E
W E
D
B
Y
D A
T E
SHEET
IDENTIFICATION
C O
N T
R A
F
A
F
R A
E I S
R A
N G
E
A
R C
H I T
E C
T E
N G
I N
E E
R
I N
S P
E C
T I O
N
S
E R
V I C
E S
F A
F n g i n e e r i n g I n c
L L
E N
E A
A
B
2 3
C
1 2 3
4 5
4 5
C
D
A
B
D
An O ne id a N at io n Co m pa ny
24'16'6' 2'4' 0' 8'
GRAPHIC SCALE 1/8" = 1'-0"
T
R
U
E
N
O
R
T
H
NORTH
PLAN
SCALE:
ELECTRICAL PLAN - SITE 54800 - NEW CONSTRUCTION
1/8" = 1'-0"
GENERAL NOTES:
1. CONTRACTOR SHALL VERIFY EXISTING CONDITIONS PRIOR
TO ANY FABRICATION OR CONSTRUCTION.
2. DEVICE LOCATIONS AND CONDUIT/CONDUCTOR ROUTING
ARE DIAGRAMMATIC AND MAY DIFFER FROM FIELD
CONDITIONS.
3. CCAFS STATIONARY GENERATORS ARE SUBJECT TO 'RICE
NESHAP' REQUIREMENTS OF 40 CFR 64, SUBPART ZZZZ.
THE GENERATOR(S) SHOULD BE COORDINATED WITH 45
CES ENVIRONMENTAL TO ENSURE THE 'RICE NESHAP'
REQUIREMENTS ARE MET BEFORE THE SYSTEM IS
BROUGHT ON SITE.
#FLAG NOTES:
1. PROVIDE NEW 125 KW GENERATOR WITH SUB-BASE FUEL TANK.
CIRCUIT BREAKER SHALL BE PROVIDED WITH NEW GENERATOR.
BASIS OF DESIGN IS CUMMINS C125D6C.
2. PROVIDE NEW CONCRETE PAD FOR NEW GENERATOR. NEW
CONCRETE PAD SHALL BE APPROXIMATELY 13'-10" LONG x 4'-4"
WIDE. COORDINATE EXACT DIMENSIONS WITH GENERATOR
BEING PROVIDED. CONCRETE PAD SHALL NOT EXCEED 62.1
SQUARE FEET MAXIMUM. REFER TO SHEET E-501 FOR DETAILS.
3. EXISTING MANUAL TRANSFER SWITCH (MTS) FOR PORTABLE
GENERATOR CONNECTION SHALL REMAIN.
4. THE FOLLOWING SHALL BE INCLUDED WITHIN NEW TRENCH:
- PROVIDE (4) #1, #6 GND IN 2" UG C (ATS TO MTS)
- PROVIDE (2) #14, #14 GND IN 1" UG C (ATS START SIGNAL)
- PROVIDE (4) #12, (2) #12 GND IN 1" UG C (BATTERY CHARGER &
JACKET HEATER)
ALL UG CONDUITS SHALL STUB-UP ONTO EXTERIOR WALL OF
BUILDING. LENGTH OF EXPOSED CONDUIT SHALL ALLOW FOR
WALL PENETRATION TO BE ABOVE HARD CEILING OF
ELECTRICAL ROOM 121A.
5. PROVIDE NEW 4-POLE AUTOMATIC TRANSFER SWITCH (ATS).
PROVIDE (4) #1, #6 GND IN 1-1/2" CONDUIT, ROUTED WITHIN
ELECTRICAL ROOM, TO EXISTING SWITCHBOARD 'MP'. PROVIDE
(4) #1, #6 GND IN 1-1/2" CONDUIT TO EXISTING PANEL 'EDP'.
6. PROVIDE NEW BATTERY CHARGER FOR GENERATOR. MOUNT
ABOVE NEW ATS. CONNECT BATTERY CHARGER TO EXISTING
PANEL 'ELP', BRANCH CIRCUIT 17.
7. PROVIDE COUNTERPOISE OF #2/0 BARE COPPER GROUNDING
CONDUCTOR, BURIED 30" BELOW FINISHED GRADE AND OFFSET
APPROXIMATELY 2 FEET FROM NEW CONCRETE PAD.
8. PROVIDE 3/4" DIAMETER x 20' DEEP GROUND ROD WITH
SECTIONS EXOTHERMICALLY WELDED TOGETHER.
9. PROVIDE #2/0 BARE COPPER GROUNDING CONDUCTOR FROM
GROUND ROD AND BOND TO FRAME OF NEW GENERATOR, AND
TO EXISTING 'MTS' FRAME.
10. PROVIDE AND MAINTAIN EROSION CONTROL MEASURE. REFER
TO DETAIL 6 ON SHEET E-502 FOR ADDITIONAL INFORMATION.
11. EXISTING BOLLARDS SHALL REMAIN.
12. CONNECT GENERATOR JACKET HEATER TO EXISTING PANEL
'ELP', BRANCH CIRCUIT 13.
13. PROVIDE (4) #1, #6 GND IN 2" CONDUIT BETWEEN EXISTING
MANUAL TRANSFER SWITCH (MTS) AND NEW GENERATOR.
TYPICAL
E-502
12 6
E-501
E-501
E-502
E-502
E-501
T
B
LP LP-1
GENERATOR
CU
CU
EXISTING
MANHOLE
S W
G R
U P
S
CB
CONCRETE PAD - ETR
XFMR 'SKSI' - ETR
F
A T
S
300 GAL
DIESEL
FUEL TANK
CONCRETE
PADS - ETR
G
U
G
E
U
G
E
E
G
600A
208V
E-102
G
B
O G
I A
T Z
I D
I S
L
C
O L E
M A
N
E L
E C
T R
I C
A
N
S
I T
E
E W
C O
N S
T R
U C
T I O
N
C
H
A R
T N
E T
T
D B
G
B
E A
R D
R E
P A
N
E R
A T
O R
S
C
C A
E T
D B
C C
A F
S
F
L U
S A
F
T
H
C
I V
G
I N
E E
R
S
Q U
A D
R O
N
I
T
E
D E
L I V
E R
Y
N
O
D R
A W
N
B
Y
D E
S I G
N E
D
B
Y
S U
B M
I T
T E
D
B
Y
R E
V I E
W E
D
B
Y
D A
T E
SHEET
IDENTIFICATION
C O
N T
R A
F
A
E I S
R A
N G
E
A
R C
H I T
E C
T E
N G
I N
E E
R
I N
S P
E C
T I O
N
S
E R
V I C
E S
F A
F n g i n e e r i n g I n c
L L
E N
E A
A
B
2 3
C
1 2 3
4 5
4 5
C
D
A
B
D
An O ne id a N at io n Co m pa ny
12'8'4'1'2' 0'
GRAPHIC SCALE 1/4" = 1'-0"
T R
U E
N O
R T
H
NORTH
PLAN
GENERAL NOTES:
1. CONTRACTOR SHALL VERIFY EXISTING CONDITIONS PRIOR TO ANY
FABRICATION OR CONSTRUCTION.
2. DEVICE LOCATIONS AND CONDUIT/CONDUCTOR ROUTING ARE
DIAGRAMMATIC AND MAY DIFFER FROM FIELD CONDITIONS.
3. CCAFS STATIONARY GENERATORS ARE SUBJECT TO 'RICE NESHAP'
REQUIREMENTS OF 40 CFR 64, SUBPART ZZZZ. THE GENERATOR(S)
SHOULD BE COORDINATED WITH 45 CES ENVIRONMENTAL TO ENSURE
THE 'RICE NESHAP' REQUIREMENTS ARE MET BEFORE THE SYSTEM IS
BROUGHT ON SITE.
4. GENERATOR WILL BE PLACED ON THE EXISTING PAD. NO NEW
IMPERVIOUS SURFACES WILL BE CREATED BY THIS PROJECT.
FLAG NOTES:
1. PROVIDE NEW 250 KW GENERATOR. CIRCUIT BREAKER SHALL BE PROVIDED
WITH NEW GENERATOR. BASIS OF DESIGN IS CUMMINS 250DQDAA.
2. PROVIDE NEW UNDERGROUND CONDUCTORS FROM EXISTING 'ATS', INSIDE
BUILDING, TO CIRCUIT BREAKER IN NEW GENERATOR. INSTALLATION OF
NEW UNDERGROUND CONDUCTOR SHALL AVOID EXISTING COUNTERPOISE.
REFER TO SINGLE-LINE DIAGRAM ON SHEET E-602 FOR ADDITIONAL
INFORMATION.
3. TRANSITION FROM UNDERGROUND ELECTRICAL (UGE) CONDUIT TO ABOVE
GROUND ELECTRICAL CONDUIT. PROVIDE PIPE SUPPORTS AS REQUIRED TO
RAISE CONDUIT ABOVE EXISTING CONCRETE SLAB.
4. PARTIAL EXISTING COUNTERPOISE, GROUNDING TEST WELL AND GROUND
ROD SHOWN FOR REFERENCE.
5. PROVIDE #2/0 BARE COPPER GROUNDING CONDUCTOR FROM EXISTING
GROUND ROD AND BOND TO FRAME OF NEW GENERATOR. CONTRACTOR
SHALL PERFORM A 'GROUND TEST' PRIOR TO REUSE OF EXISTING GROUND
ROD. TEST PER SPEC SECTION 26 20 00 INTERIOR DISTRIBUTION SYSTEM.
6. EXISTING AUTOMATIC TRANSFER SWITCH (ATS) SHALL REMAIN. PROVIDE (2)
#14, #14 GND IN 1" UG CONDUIT TO NEW GENERATOR FOR START SIGNAL.
UTILIZE EXISTING PATCHED WALL PENETRATION NEXT TO 'ATS' NEAR
FLOOR. PROVIDE FIRESTOP, OR EQUAL, TO SEAL PENETRATION. PATCH
AND PAINT TO MATCH EXISTING EXTERIOR FINISH.
7. EXISTING FUEL TANK SHALL REMAIN.
8. PROVIDE NEW FUEL PIPING AND SUPPORTS AS REQUIRED TO EXTEND
EXISTING PIPING TO THE NEW GENERATOR. PIPING SHOWN IS
DIAGRAMMATIC. FUEL CONNECTION POINTS AND INSTALLATION SHALL BE
COORDINATED WITH GENERATOR MANUFACTURER'S REQUIREMENTS.
FIELD ROUTE PIPING TO MEET MANUFACTURER'S REQUIREMENTS.
9. PROVIDE (2) #12, #12 GND IN 1" UG CONDUIT TO NEW GENERATOR. UTILIZE
EXISTING PATCHED WALL PENETRATION NEXT TO 'ATS' NEAR FLOOR. NEW
UG CONDUIT SHALL BE SHARED WITH BATTERY CHARGER. CONNECT
GENERATOR JACKET/BLOCK HEATER TO CIRCUIT RETAINED IN EXISTING
PANEL 'LP'.
10. PROVIDE (2) #12, #12 GND IN 1" UG CONDUIT; SHARED WITH JACKET/BLOCK
HEATER. CONNECT GENERATOR BATTERY CHARGER TO CIRCUIT RETAINED
IN EXISTING PANEL 'LP'.
11. REROUTE/EXTEND EXISTING 4" CONDUIT TO NEW GENERATOR. NO NEW
WALL PENETRATION IS REQUIRED.
12. EXISTING POWERWARE UPS 9390-160. PROGRAM UPS FOR 0% BATTERY
CHARGING WHEN GENERATOR IS RUNNING.
SCALE:
ELECTRICAL PLAN - SITE 50225 - NEW CONSTRUCTION
1/4" = 1'-0"
E-502
10 11
12 5
E-502
SCALE:
GROUND ROD DETAIL
NONE
E-101
'CADWELD' TYPE
EXOTHERMIC WELD, TYPICAL
3/4" x 20' CU CLAD
STEEL GND RODS
MINIMUM OF 2
#2/0 BSD CU GROUNDING
CONDUCTOR - MIN 24" BFG
#2/0 BSD CU TO EQPM GND
BUS OR GENERATOR FRAME
TYPICAL
G G
G
G
GG
G
24"
TYP ALL
SIDES
3/4" x 20' CU CLAD
STEEL GND ROD
G G
L
C
O L E
M A
N
24" MIN
SOD
E-501
G
B
O G
I A
T Z
I D
I S
E L
E C
T R
I C
T
A I L
S
U S
T
H
C
I V
G
I N
E E
R
S
Q U
A D
R O
N
I
T
E
D E
L I V
E R
Y
N
O
D R
A W
N
B
Y
D E
S I G
N E
D
B
Y
S U
B M
I T
T E
D
B
Y
R E
V I E
W E
D
B
Y
D A
T E
SHEET
IDENTIFICATION
C O
N T
R A
F
A
F
R A
E I S
R A
N G
E
A
R C
H I T
E C
T E
N G
I N
E E
R
I N
S P
E C
T I O
N
S
E R
V I C
E S
F A
F n g i n e e r i n g I n c
L L
E N
E A
A
B
2 3
C
1 2 3
4 5
4 5
C
D
A
B
D
An O ne id a N at io n Co m pa ny
C
H
A R
T N
E T
T
D B
G
B
E A
R D
R E
P A
N
E R
A T
O R
S
C
C A
E T
D B
C C
A F
S
F
L
SCALE:
SECTION
NONE
A
SCALE:
TYPICAL PAD MOUNTED EQPM GROUNDING DETAIL
NONE
E-101
#2/0 BSD CU GND
CONDUCTOR
'CADWELD' TYPE
EXOTHERMIC WELD
8"
3'-0" +/-
TYPICAL TIE-DOWN PER
MANUFACTURERS
RECOMMENDATION
12"
MIN
FINISHED GRADE
SCALE:
TYPICAL CONCRETE SLAB DETAIL
NONE
E-101
3/4" CHAMFER
TYPICAL ALL SIDES 4 x 4-W 2.9 x W 2.9 W W F
2 LAYERS; (1) TOP, (1) BOTTOM
CONDUIT STUB-UPS PER
MANUFACTURERS
RECOMMENDATION
TYPICAL GROUND CABLE
STUB-UP (MINIMUM OF 2
REQUIRED)
SCREW ANCHORS DEEPER INTO
GROUND FOR EYE TO PROJECT
JUST ABOVE NEW SLAB HEIGHT
12" COMPACTED BACKFILL
4 x 4 - W2.9 x W2.9 WWF
A
LIMIT OF EXCAVATION LEVEL
TIE DOWN STRAPS OR FASTENERS PER
MANUFACTURERS RECOMMENDATION
6"
3" CLR
CONSTRUCTION NOTES:
1. EXCAVATE EXISTING SOIL MATERIAL TO ELEVATION SHOWN.
2. COMPACT TOP 12" OF SUB-GRADE TO 95% OF MAXIMUM DENSITY
OBTAINED BY THE MODIFIED PROCTOR METHOD 'B' OR 'D'.
3. SOIL TESTING SERVICE TO SAMPLE AND DETERMINE WHETHER
EXCAVATED MATERIAL IS ACCEPTABLE BACKFILL.
4. PLACE BACKFILL MATERIAL AND COMPACT GRADE UNDER PAD TO 98%
MODIFIED PROCTOR DENSITY. BACKFILL PAD PERIMETER AT 4:1 SLOPE
TO EXISTING GRADE.
5. GRADE AND COMPACT ADJACENT AREAS FOR SMOOTH FINISHED
SURFACE. PLACE TOPSOIL BLEND OVER FINISHED AREAS AND COVER
WITH ARGENTINE BAHIA SOD.
6. CONCRETE PAD SHALL BE LIMITED TO 62.1 SQUARE FEET MAXIMUM.
STRUCTURAL NOTES:
1. CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3,000
PSI AT 28 DAYS.
2. JOINT SEALANT MATERIAL SHALL CONFORM TO ASTM D 1850 AND BE
USED TO SEAL ALL SAWED JOINTS.
3. MOISTURE BARRIER, 6 MIL POLYETHYLENE FILM, SHALL BE INSTALLED
UNDER ALL CONCRETE SLABS/FOUNDATIONS ON GRADE.
ELECTRICAL NOTES:
1. NEW #2/0 BARE COPPER CONDUCTORS SHALL BE BONDED TO THE
EQUIPMENT SUPPORT STRUCTURES AND THE NEW GENERATOR FRAME.
2. GROUND CONNECTION BELOW GRADE SHALL BE EXOTHERMIC WELD
TYPE. ABOVE GROUND CONNECTIONS SHALL BE BOLTED TERMINAL OR
CLAMP TYPE.
3. TOP OF GROUND RODS SHALL BE 24" BELOW GRADE. TEST AND RECORD
RESISTANCE OF EACH GROUND ROD PRIOR TO CONNECTING CABLES.
TEST PER SPEC SECTION 26 20 00 INTERIOR DISTRIBUTION SYSTEM.
EARTH
VAPOR BARRIER
CONDUIT STUB-UPS PER
MANUFACTURERS RECOMMENDATION
ALL SIDES OF CONCRETE PAD
SHALL BE 6" LARGER THAN
GENERATOR
THICKENED EDGES ALL
SIDES WITH #4 HOOK BARS
& (2) #4 CONTINUOUS BARS
FINISHED GRADE
G
GROUND CABLE
STUB-UP, TYPICAL
H
A R
T N
E T
T
E-502
G
B
O G
I A
T Z
I D
I S
L
C
O L E
M A
N
E L
E C
T R
I C
T
A I L
S
U S
T
H
C
I V
G
I N
E E
R
S
Q U
A D
R O
N
I
T
E
D E
L I V
E R
Y
N
O
D R
A W
N
B
Y
D E
S I G
N E
D
B
Y
S U
B M
I T
T E
D
B
Y
R E
V I E
W E
D
B
Y
D A
T E
SHEET
IDENTIFICATION
C O
N T
R A
F
A
F
R A
E I S
R A
N G
E
A
R C
H I T
E C
T E
N G
I N
E E
R
I N
S P
E C
T I O
N
S
E R
V I C
E S
F A
F n g i n e e r i n g I n c
L L
E N
E A
A
B
2 3
C
1 2 3
4 5
4 5
C
D
A
B
D
An O ne id a N at io n Co m pa ny
D B
G
B
E A
R D
R E
P A
N
E R
A T
O R
S
C
C A
E T
D B
C C
A F
S
F
L
SCALE:
FOR PARKING LOTS & DRIVEWAYS
NONE
E-101
TYPICAL PAVEMENT RESTORATION
EXISTING
ASPHALT
SURFACE
TACK
COAT
VARIES
9"
MIN
VARIES
12"
MIN
12"
MIN
VARIES
12"
7" MIN
12"
7" MIN
ID
FLAG NOTES:
1. ASPHALT SHALL BE ASPHALTIC CONCRETE SUPERPAVE SP-12.5;
CONCRETE SHALL BE 3000 PSI MINIMUM.
2. A SLOPE OF 2:1 RATIO SHALL BE USED ONLY WHEN SOIL CONDITIONS DO
NOT ALLOW VERTICAL TRENCHING.
3. COMPACTED SUB-BASE MATERIAL SHALL BE FREE OF ASPHALT, LARGE
ROCKS (1-1/2" DIAMETER MAXIMUM), WOOD, ROOTS AND OTHER ORGANIC
MATTER.
4. NEW ASPHALT SURFACE SHALL BE MINIMUM OF 2" THICKNESS, OR SHALL
MATCH EXISTING THICKNESS FOR CONCRETE PAVEMENT.
5. CONTRACTOR SHALL EXCAVATE BOTTOM OF TRENCH TO ALLOW FOR
BELL SECTION OF PIPE.
6. PROVIDE 12" OF COMPACTED SUB-BASE MATERIAL BENEATH THE
HAUNCHES OF THE PIPE USING MECHANICAL TAMPS. THIS COMPACTION
APPLIES TO THE MATERIAL PLACED BENEATH THE HAUNCHES OF THE
PIPE AND ABOVE ANY BEDDING REQUIRED. COMPACTION SHALL BE DONE
IN 3" LAYERS. BACKFILL SHALL BE COMPACTED TO 98% MAXIMUM
DENSITY UNDER ROADS, CURB AND GUTTER, OR 98% MAXIMUM DENSITY
IN SHOULDERS AND OUTSIDE ROAD RIGHT OF WAY. MAXIMUM DENSITY
SHALL BE AS DETERMINED BY THE MODIFIED PROCTOR COMPACTION
TEST, AASHTO T-180, EVERY 500'.
7. PROVIDE 9" OF LBR40 LIMEROCK UNDER ROADWAY. BASE MATERIAL
REPLACED OVER DITCH SHALL BE TWICE THE THICKNESS OF THE
ORIGINAL BASE, OR 12" MINIMUM.
8. ASPHALT CONCRETE PAVEMENT JOINTS SHALL BE MECHANICALLY
SAWED. SURFACE TREATED PAVEMENT JOINTS SHALL BE LAPPED AND
FEATHERED.
9. BASE MATERIALS SHALL BE EITHER OF THE SAME TYPE AND
COMPOSITION AS THE MATERIALS REMOVED OR, EQUAL OR GREATER
STRUCTURAL ADEQUACY. BASE MATERIAL SHALL BE COMPACTED TO 98%
MAXIMUM DENSITY DETERMINED BY AASHTO T-180, EVERY 500'.
10. DETECTABLE TYPE MARKER TAPE WITH 0.35 MIL THICK METALLIC FOIL
CORE PLACED AT 12" BELOW FINISHED GRADE.
11. PROVIDE 316 STAINLESS STEEL UNISTRUT SUPPORT FRAME TO KEEP PIPE
AT 8", ON CENTER, ABOVE FINISHED CONCRETE.
UNDISTURBED
EARTH
1 6 9
SILT FLOW
18" MIN
FILTER FABRIC
ELEVATION
SECTION
EROSION CONTROL NOTES:
1. AFTER EACH STORM EVENT, THE SILT FENCE SHALL BE INSPECTED. SEDIMENT
DEPOSITS SHALL BE REMOVED AND WASHOUTS/STRUCTURAL FAILURES SHALL BE
REPAIRED IMMEDIATELY.
2. TWO SILT FENCES SHALL BE ATTACHED BY PLACING THE END POST OF THE SECOND
FENCE INSIDE THE END POST OF THE FIRST FENCE. BOTH POSTS SHALL BE
ROTATED AT LEAST 180° IN A CLOCKWISE DIRECTION TO CREATE A TIGHT SEAL WITH
THE FABRIC MATERIAL. DRIVE BOTH POSTS 18" INTO THE GROUND AND BURY FLAP.
3. SILT FENCES SHALL BE REMOVED ONLY AFTER DISTURBED AREAS HAVE BEEN
STABILIZED.
WOOD POST @ 10' OC
MIN 1" x 2" x 3'
TRENCH MIN 4" x 4" BURY MIN 8" OF
FABRIC IN TRENCH
GEOTEXTILE SILT SCREEN
STAPLE TO POST
SCALE:
EROSION CONTROL MEASURES - SILT FENCE DETAIL
NONE
ED-101
E-101
FRONT VIEW
SCALE:
THRU-WALL CONDUIT PENETRATION DETAIL
NONE
E-101
E-102
A
SCALE:
SECTION
NONE
A
THRU-WALL PENETRATION NOTES:
1. EXISTING CMU WITH STUCCO FINISH EXTERIOR WALL.
2. WALL PENETRATING SLEEVE - EXTERIOR TO INTERIOR.
3. CONDUIT WITHIN WALL SLEEVE.
4. FLEXIBLE FIRESTOP SEALANT SURROUNDING WALL PENETRATING SLEEVE;
HILTI CP 606 OR EQUAL.
4 TYPICAL
SCALE:
PIPE MOUNTING DETAIL
NONE
E-102
316 STAINLESS
STEEL PIPE CLAMP
STAINLESS STEEL
CHANNEL
316 STAINLESS STEEL
3/8" DIAMETER x
4" LONG ANCHOR
TYPICAL STOP LOCK
8"
36"
100A ATS
3P
SCALE:
SINGLE-LINE DIAGRAM - SITE 54800 - EXISTING & NEW
NONE
SWBD 'MP' 2000A
480Y/277V, 3Ø, 4W
(4) #3, (1) #8 GND IN 1-1/4" C
G
20A 20A 350A 70A 30A
200A 125A 100A 350A 70A 30A 100A
PANEL 'EDP' 100A
480Y/277V, 3Ø, 4W
E-601
G
B
O G
I A
T Z
I D
I S
L
C
O L E
M A
N
S I N
G L
E L
I N
E
D
I A
G R
I T
E
C
H
A R
T N
E T
T
D B
G
B
E A
R D
D B
C C
A F
S
F
L U
S A
F
T
H
C
I V
G
I N
E E
R
S
Q U
A D
R O
N
I
T
E
D E
L I V
E R
Y
N
O
D R
A W
N
B
Y
D E
S I G
N E
D
B
Y
S U
B M
I T
T E
D
B
Y
R E
V I E
W E
D
B
Y
D A
T E
SHEET
IDENTIFICATION
C O
N T
R A
F
A
E I S
R A
N G
E
A
R C
H I T
E C
T E
N G
I N
E E
R
I N
S P
E C
T I O
N
S
E R
V I C
E S
F A
F n g i n e e r i n g I n c
L L
E N
E A
A
B
2 3
C
1 2 3
4 5
4 5
C
D
A
B
D
An O ne id a N at io n Co m pa ny
R E
P A
N
E R
A T
O R
S
C
C A
E T
PORTABLE
GENERATOR
NIC
G
EMERGENCY SERVICE GENERATOR
125KW, 480Y/277V, 3Ø, 4P, 4W, 0.8 PF
WEATHER PROOF ENCLOSURE WITH
BASE MOUNTED 274 GALLON FUEL TANK
MTS - ETR
ANN
CB
GENERAL NOTES:
1. CONTRACTOR SHALL VERIFY EXISTING CONDITIONS PRIOR TO ANY
FABRICATION OR CONSTRUCTION.
2. DEVICE LOCATIONS AND CONDUIT/CONDUCTOR ROUTING ARE
DIAGRAMMATIC AND MAY DIFFER FROM FIELD CONDITIONS.
FLAG NOTES:
1. DISCONNECT AND REMOVE EXISTING 50 KW GENERATOR. REMOTE
ANNUNCIATOR AND CIRCUIT BREAKER ARE INTEGRAL TO GENERATOR
BEING REMOVED.
2. DISCONNECT AND REMOVE EXISTING 100A, 480V, 3 POLE, 3Ø, 4 WIRE,
AUTOMATIC TRANSFER SWITCH (ATS) LOCATED IN ELECTRICAL ROOM
121A.
3. DISCONNECT AND REMOVE EXISTING BATTERY CHARGER LOCATED
ABOVE 'ATS' BEING REMOVED, IN ELECTRICAL ROOM 121A.
4. PROVIDE NEW 125 KW GENERATOR WITH SUB-BASE FUEL TANK.
CIRCUIT BREAKER AND REMOTE ANNUNCIATOR ARE INTEGRAL TO
NEW GENERATOR.
5. PROVIDE NEW 100A, 4-POLE AUTOMATIC TRANSFER SWITCH (ATS).
6. PROVIDE NEW GENERATOR BATTERY CHARGER. LOCATE IN
ELECTRICAL ROOM 121A. PROVIDE (2) #12, #12 GND IN 1" UG C;
CONDUIT SHARED WITH JACKET HEATER CIRCUIT.
7. PROVIDE (2) #14, #14 GND IN 1" UG C FOR 'ATS' START SIGNAL.
BATTERY
CHARGER
(4) #3, (1) #8 GND IN 1-1/4" C
SCALE:
SINGLE-LINE DIAGRAM - SITE 54800 - EXISTING & DEMO
NONE
160A ATS
4P
SWBD 'MP' 2000A
480Y/277V, 3Ø, 4W
(4) #1, (1) #6 GND IN 1-1/2" C
G
20A 20A 350A 70A 30A
200A 125A 100A 350A 70A 30A 100A
PANEL 'EDP' 100A
480Y/277V, 3Ø, 4W
PORTABLE
GENERATOR
NIC
G
MTS - ETR
CB
BATTERY
CHARGER
(4) #1, (1) #6 GND IN 1-1/2" C
(4) #1, (1) #6
GND IN 2" UG C
(4) #3, (1) #8 GND IN 1-1/4" C
E-602
G
B
O G
I A
T Z
I D
I S
L
C
O L E
M A
N
S I N
G L
E L
I N
E
D
I A
G R
I T
E
C
H
A R
T N
E T
T
D B
G
B
E A
R D
D B
C C
A F
S
F
L U
S A
F
T
H
C
I V
G
I N
E E
R
S
Q U
A D
R O
N
I
T
E
D E
L I V
E R
Y
N
O
D R
A W
N
B
Y
D E
S I G
N E
D
B
Y
S U
B M
I T
T E
D
B
Y
R E
V I E
W E
D
B
Y
D A
T E
SHEET
IDENTIFICATION
C O
N T
R A
F
A
F
R A
E I S
R A
N G
E
A
R C
H I T
E C
T E
N G
I N
E E
R
I N
S P
E C
T I O
N
S
E R
V I C
E S
F A
F n g i n e e r i n g I n c
L L
E N
E A
A
B
2 3
C
1 2 3
4 5
4 5
C
D
A
B
D
An O ne id a N at io n Co m pa ny
R E
P A
N
E R
A T
O R
S
C
C A
E T
ATS
600A
CCT3
SPARESPARE
SCALE:
SINGLE-LINE DIAGRAM - SITE 50225 - EXISTING, DEMO & NEW
NONE
FLAG NOTES:
1. DISCONNECT AND REMOVE EXISTING 180 KW GENERATOR. PROVIDE NEW
250 KW GENERATOR. CIRCUIT BREAKER IS INTEGRAL TO NEW
GENERATOR.
2. EXISTING CIRCUIT FROM 'UPS' TO AUTOMATIC TRANSFER SWITCH (ATS)
SHALL REMAIN. PROGRAM 'UPS' FOR 0% BATTERY CHARGING WHEN
GENERATOR IS RUNNING.
3. PROVIDE (2) #14, #14 GND IN 1" UG C FOR 'ATS' START SIGNAL.
GENERAL NOTES:
1. CONTRACTOR SHALL VERIFY EXISTING CONDITIONS PRIOR TO ANY
FABRICATION OR CONSTRUCTION.
2. DEVICE LOCATIONS AND CONDUIT/CONDUCTOR ROUTING ARE
DIAGRAMMATIC AND MAY DIFFER FROM FIELD CONDITIONS.
TO 20A BRKR
IN PANEL 'P1'
UPS 600A INPUT
BYPASS
DISTRIBUTION
SWITCHBOARD
UPS-1
POWERWARE
208-208V
TO 225A BRKR
IN PANEL 'LP'
30 KVA XFMR
208V - 480Y/277V
PNL
'PS'
BLDG
50210
300AT
400AF
IBC-L J-47
CABINET 1
IBC-L J-47
CABINET 2
RMP
BLDG
50211
OUTDOOR
ECB
UTILITY POWER
SOURCE
BATTERY
CONVERTER
RECTIFIER
FUSE
RIB1
600A
'NC'
MBP
600A
'NO'
MIS
600A
'NC'
STATIC
SWITCH
INVERTER
FUSE
PNL 'LP-1'
450A, 208Y/120V, 3Ø, 4W
450AT
600AF
100A 100A 225A 20A
(K1) (K5)
FUSE
(K3)
300A300A
DCM
SKRU
G
(8) #350, (1) #1/0 GND IN
EXISTING/EXTENDED 4" C
| Sheets and Views |
| G-001 LOCATION MAP, PROJECT AREAS AND DRAWING INDEX |
| H-001 GENERAL HAZMAT NOTES, ABBREVIATIONS AND APPLICABLE CODES |
| H-101 HAZARDOUS MATERIALS PLAN - BLDG 54800 CHEM LAB |
| H-102 HAZARDOUS MATERIALS PLAN - BLDG 50225 RUNWAY VAULT |
| E-001 ELECTRICAL NOTES, LEGEND AND ABBREVIATIONS |
| ED-101 ELECTRICAL PLAN - SITE 54800 - DEMOLITION |
| ED-102 ELECTRICAL PLAN - SITE 50225 - DEMOLITION |
| E-101 ELECTRICAL PLAN - SITE 54800 - NEW CONSTRUCTION |
| E-102 ELECTRICAL PLAN - SITE 50225 - NEW CONSTRUCTION |
| E-501 ELECTRICAL DETAILS |
| E-502 ELECTRICAL DETAILS |
| E-601 SINGLE-LINE DIAGRAM - SITE 54800 |
| 1 |
| E-602 SINGLE-LINE DIAGRAM - SITE 50225 |
| 1 |
File details come from the government source that posted it. Updated .