Attach 1 SoW - Training Facility 30 Dec 19.docx
DOCX document 369 KB Posted
- Attached to
- Training Facility with internet connectivity Federal contract opportunity
- Solicitation number
- FA2518-20-Q-0003
About this file
This solicitation and statement of work describe requirements for a training facility space and internet connectivity. The Air Force Space Command seeks a facility within 10 miles of Peterson Air Force Base to host up to five eight-week intermediate cybersecurity courses per year for 20 students and two instructors. The contractor must provide a secure room meeting audio/visual, seating, desk, and temperature requirements; internet bandwidth of at least 75Mbps; and connectivity for each student and instructor workstation. Quotes are due by February 3rd, 2020 and the base period of performance is February 17, 2020 to February 16, 2021, with four optional one-year extensions. The acquisition will be set aside for small businesses and awarded on a lowest price technically acceptable basis.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Question and Answers to RFQ Amendment 1.pdf | ||
| RFQ FA2518-20-Q-0003 Facility Space Amendment 1.rtf | RTF text file | |
| Attach 1 SoW - Training Facility 9 Jan 2020 Anendment 1.docx | DOCX document | |
| Attach 2 Pricing Summary Amendment 1.xlsx | XLSX spreadsheet | |
| Attach 2 Pricing Summary.xlsx | XLSX spreadsheet | |
| RFQ FA2518-20-Q-0003 Facility Space.rtf | RTF text file |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Statement of Work for Headquarters Air Force Space Command (AFSPC) Intermediate CyberCore (ICC) Training Facility
Statement of Work
FOR
Headquarters Air Force Space Command (AFSPC) Intermediate CyberCore (ICC) Training Facility
30 December 2019
AIR FORCE SPACE COMMAND
Table of Contents
| 1. Overview | 3 |
| 2. Facility Requirements | 3 |
| 3. Facility Network Requirements | 5 |
1. Overview Description of Service: Headquarters Air Force Space Command (AFSPC), Directorate of Operations & Communications, Cyber Operations Division, requests a facility to provide training to Mission Defense Team (MDT) Trainees throughout the command. This facility will allow for delivery of Intermediate Cyber Core (ICC) Training.
The ICC training is being taught by the a team of 2 instructors, provided by DC3 (Defense Cyber Crime Center). The Government shall provide all computers, monitors, manuals and instructors.
1.1 Facility Requirements
These facility requirements are in place to provide an environment conducive to student learning and to ensure the security and protection of training equipment.
1.1.1. Secure room: A secure room is required for course delivery.
a. Security:
a.1 The instructors must be able to secure the room at the end of each day and on the weekends. Instructor possession of a key to the training space is not required, but they must have access to the room provided before and after class each day so that they can perform administrative duties and pack equipment at the end of the last week.
a.2 Spaces, housing, instructor/student equipment must not be accessible to 3rd parties while class not in session.
b. HVAC:
b.1 The facility must have an adequate and operational heating, ventilation and air conditioning system for up to 20 students plus 2 instructors and their equipment.
b.2 Equipment used in the course generates a significant amount of heat, the team must be able to adjust facility temperature as needed to prevent equipment from overheating (or provide feedback to facility to adjust as needed). Acceptable room temperatures shall be from 67 degrees and 75 degrees.
c. Equipment:
c.1 The facility must have at least one audio/visual (AV) system that allows for display of instructor demonstration activities and course material to the class. The AV system should include the capability to connect to the instructor PC via HDMI.
c.2. The facility must have at least one dry erase whiteboard, capable to be clearly seen by all students with supplies. Minimum size of whiteboard is 4ft by 6ft and supplies consist of at least a set of dry erase markers (Green/Red/Blue/Black), eraser and clearning supplies.
d. Student Desks/Seating:
d.1 The facility must have seating/desk space for up to 20 students.
d.2 Each student must have, at a minimum, a 3-by-3-foot space on a desk or table to accommodate a course manual, a laptop and a secondary monitor. (Photo below depicts example of space required for student workstation.) NOTE: L-shaped desk configuration depicted above is NOT required, merely used for reference.
d.3 Each student requires an office chair condusive to a learning environment. Chairs shall be cushioned and able to roll in the students area.
e. Instructor Desks/Seating:
e.1 There shall be two instructor desks. The instructor desks must be at the front of the facility.
e.2 The instructor desks requires equivalent available space, to the student seating described in d.2.
e.3 Each instructor requires an office chair. Chairs shall be cushioned and able to roll in the instructor’s area.
f. Facility availability/location:
f.1 Below is the estimated schedule for the base period. Option periods are estimated to have 3-5 courses per year and dates will be pre-coordinated a minimum of 30 days in advance.
| Base Period |
| Facility Setup Day |
| 2 Mar - 24 Apr |
| 28 Feb 2020 (8:00 am – 5:00 pm |
| June – July (exact dates TBD) |
| TBD |
| Sept – Oct (exact dates TBD) |
| TBD |
**Note: Classes are 8 consecutive weeks with 1 day for set up prior to class start and up to 1 day for class breakdown. The Government estimates 3-5 courses per year and can fluctuate based on Government need and funds availability. There could be zero classes per year up to 5 classes per year. The Government will provide a minimum of a 30 day notice for facility need dates for the option periods.
f.2 For the dates provided, the facility must be available Monday-Friday from 8 a.m. to 4:30 p.m.
f.3 Facility must be within 10 miles of Peterson AFB. The following address can be used as a reference point:
150 Vandenberg St, Colorado Springs, CO 80914
1.2 Facility Network Requirements
1.2.1 Network Configuration
a.1 Firewall: There should be a firewall provided within the existing infrastructure at the training facility.
a.2 Router: 1x for internet connectivity if allotting a dedicated commercial internet connection.
a.3 Adequate power supply: The facility space must be equipped with an electrical power supply sufficient for the required workstation setups for 20 students, 2 instructors and AV equipment.
1.2.2 Internet access:
b.1 Accessibility: Access to open, unclassified internet is required for course delivery. In addition, students/instructors must be able to access the following domain: dcita.edu. Access to this domain can be tested by navigating to https://learn.dcita.edu b.2 Internet Bandwidth: ≥3.0 Mbps/student and up to 2 instructors is required (e.g., 25 users = 75 Mbps per facility).
b.3 Internet connectivity:
b.4 Connection: Each student must be able to connect to the internet connection via an ETHERNET cable, 10/100 at a minimum.
UNCLASSIFIED
Air Force Space Command
UNCLASSIFIED
Air Force Space Command image2.jpeg image3.jpeg image1.jpeg
File details come from the government source that posted it. Updated .