This document is a Request for Quotation (RFQ) for a Firm Fixed Price (FFP) purchase order to provide PFAS wastewater treatment services. The 21st Contracting Squadron (21 CONS) of the Department of the Air Force Space Command is soliciting this requirement as a 100% small business set-aside under NAICS code 562910 - Remediation Services.

The Government intends to award one contract to the responsible Offeror whose quotation represents the Best Value. Offerors must have a CAGE code and be registered with SAM. Quotations are due by 10 September 2024 at 1000 hours MT, and all questions must be submitted by 4 September 2024 at 1000 hours MT. Quotations should be sent via email to the specified points of contact. No telephone questions will be answered, and late questions may not be addressed.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Login Sample Receipt Checklist

Login Number: 73600

Question Answer Comment

Creator: Ortiz, Erick E

List Number: 1

N/ARadioactivity wasn't checked or is </= background as measured by a survey meter.

TrueThe cooler's custody seal, if present, is intact. 1190424

N/ASample custody seals, if present, are intact.

TrueThe cooler or samples do not appear to have been compromised or tampered with.

TrueSamples were received on ice.

TrueCooler Temperature is acceptable.

TrueCooler Temperature is recorded.

TrueCOC is present.

TrueCOC is filled out in ink and legible.

TrueCOC is filled out with all pertinent information.

TrueIs the Field Sampler's name present on COC?

TrueThere are no discrepancies between the containers received and the COC.

TrueSamples are received within Holding Time (excluding tests with immediate HTs)

TrueSample containers have legible labels.

TrueContainers are not broken or leaking.

TrueSample collection date/times are provided.

FalseAppropriate sample containers are used. Refer to Job Narrative for details.

TrueSample bottles are completely filled.

N/ASample Preservation Verified.

TrueThere is sufficient vol. for all requested analyses, incl. any requested MS/MSDs

TrueContainers requiring zero headspace have no headspace or bubble is <6mm (1/4").

TrueMultiphasic samples are not present.

TrueSamples do not require splitting or compositing.

N/AResidual Chlorine Checked.