Attach_3__1st_Floor_Mechanical_Drawings.PDF
PDF 255 KB Posted
- Attached to
- Bldg 140 HVAC Federal contract opportunity
- Solicitation number
- FA2517-17-Q-5072
About this file
Attach 3 - 1st Floor Mechanical Drawings
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| RFQ_PAFP_HVAC_B140_-_Amend_1.pdf | ||
| Attach_1_-_B140-SOW_Replace_HVAC_Units.pdf | ||
| Attach_4__2nd_Floor_Mechanical_Drawings.PDF | ||
| RFQ_PAFP_HVAC_B140.pdf | ||
| Attach_2_-_Contractor_Submittal_Form.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MECHANICAL
HVAC#1 CONDENSER
MOUNTED ON PAD
REFRIGERANT LINES
OUTSIDE AIR
30"x12"R.A.G.
OUTSIDE AIR
HVAC#5 MOUNTED ON PAD
LOCATED UNDER STAIRWAY
REFRIGERANT LINES
ABANDONED STEAM LINES
UH-1
LP5-12
3/4"3/4"
3/4"
3/4"
3/4"
1 1/4"1 1/4"
1 1/4" 3/4"
3/4"
3/4"
1"
2" 3"
1 1/4"
1 1/4" 3/4"
STEAM LINE
COND. RETURN
CAPS
UP TO HVAC #5
F&T TRAP
2 1/2"
GRADE
TRAP
GRADE
GRADE
NORTH
GRADE
TEE CAPPED
STEAM SUPPLY
1 1/2"
1 1/2"
1/2" AIR LOOP
1"1/2" 1 1/4" 1/2"
1 1/2"
4"
1 1/4" COND LINE
DROP
1/2" AIR LOOP
RISE
1/2" AIR LOOP
RISEDROPRISEDROP
3/4"
1/2" AIR LOOP
3/4"
1/2" AIR LOOP
NIPPLE CAPPED
RISE
DROP
2"
1/2" AIR LOOP
1 1/4"
1/2" AIR LOOP 3/4" COND. LINE
COND. LINE
3/4" TRAP
1 1/4" COND. LINE
6" DIRT LEG
3" STEAM MAIN
1 1/2"
THERM.
1"
1/2" DROP & TIE INTO
COND. RET.
TRAP
COND. LINE
1/2" 3/4"1/2"
1/2"
STEAM SUPPLY
1/2" AIR LOOP
THERM. ACTIVATED
RAD. VALVE 3/4"
MOTORIZED 3/4"
RAD. VALVE
1 1/4"
UH-1
3/4" COND. RET.
3/4" COND. RET.
3/4" STEAM
3/4" COND. RET.
3/4" STEAM
1" STEAM
ELECTRIC
WATER HEATER 114
111109
110A
108106
106B106A
103B103
102101
131132
136137140
133B 142141 143
120A120B118
126 124
121119
103A
133A
133C
142A
Building #140 1st Floor
REFRIG
/1
A H U -2
A H U -3
A H U -6
U H -2
H W
R G
HWR
/4
/2
/2
/2
B -2
B -1
ET
-1
A S -1
P-
P-
G
H W
S
HWS
"Ø
"F
S -1
L-
L- 4L-
M M
L-
L-
A H U -6
/1
/1
L-
M
/3
/3
M
/2
/2
26/26
/6
/6
L-
M
/1 "Ø
"Ø
R F-
D
30/26
/1
M
RL
T
/2
A H U -1
R S
/4
/4
/2
/2
/2
/4
/2
/2
"Ø6 "Ø
M
/2
/2
/2
A
(T
YP
"Ø
12"Ø 10"Ø14"
Ø
"Ø
14"Ø 12"Ø 10"Ø
Ø
"Ø
"Ø
36/12R18/12
A
"Ø
14/10 18/10
A
"Ø
20/12 22/12
C
/8
A
(T
YP
"Ø
A
"Ø
A
"Ø
18/16
A
(T
YP
"Ø
18/16 18/16
/1
34/16
H C
-6
H C
-6
H C
-6
HWR
HWSHWS
HWR
HWS
20/12
/8
/8
/8
/8
12/8
D
"Ø
"Ø
/1
20/12
"Ø
/8
20/12
16/12
/8
D
(T
YP
"Ø
/8
/1
/4 D
(T
YP
/1
A
"Ø
A "Ø
A "Ø
A
(T
YP
"Ø
A "Ø
A
(T
YP
"Ø
H W
S
HWS
HWR
H W
S H W
R
HWS
HWR
HWS
HWR
16/12
A
"Ø
A
(T
YP
"Ø
HWR
HWS
8/10
A
"Ø
HWS
C H -2
HWR
HWS
HWR
C H -3
18"Ø
"Ø
12"Ø
"Ø
18"Ø
8" Ø
"Ø
12"Ø
"Ø8"Ø
HWR
HWS
C H -1
C
(T
YP
/6
C
(T
YP
/6
/2
B
C
/6
E
/6
H C
-1
H C
-1
/1
16/16
C
/6
A
(T
YP
"Ø
14/1210/10
"Ø
F
"Ø
A
"Ø
A
"Ø
D
"Ø
/6
/6
"Ø
/6
F
"Ø
E
/8
EF
-2
E
/1
H W
S H W
R
HWR
HWS HWS
HWR
/1
G
/8G
/8
E
B
B
/1
/1
B
/2
/2
/2 .0
F T
FT
R -1
.6
M B H
.5
G
PM
A
"Ø
H W
R H W
S
G
/8
B
/1
/6
B
B
.0
F T
FT
R -1
.0
M B H
.5
G
PM
HWS
G
/1
36/12
B
10/8
D
(T
YP
"Ø
B B
/82
/8
B
B
B
B
/1 0 B
B
B
E
/2
B
E
/1
B
/1
22/18
B B
B
R
R F-
/2
/2
/1
/1
H W
R H W
S
HWR
/1
4 R S
R L
C U -6
HWR HWR HWR
R S
R L
C U -5
T A H U -2 S
TS
AHU-3
/1
R
FA
/2
R
FA
"Ø
B
RS
RL
B
B
/8
B
T
B
/8
/1
H C -1
T
S
HWRHWR
HWS
/1
T H C -1
S
R S
C U -1
" H
W S U
P
T
/4
" 1
/4
/4
T H C -6
S
T
" H
W S U
P
T
/2
T H C
-6
S
/2 "2
/4 " 1
HWR
/2
/4
/4
"2
/2
T H C -6
S
/2 " 2
/2
T C H -3
T1
" H
W R U
P
T
/4
T
/2
" H W
S U
P
/4
/4
/2
/2 " H
W R U
P
/4
" U
.G
" U
.G
H G
HGHG
" M
IN
/1
/1
/2
/2
B
/2
B
/2
B
/2
/1
B
/1
/2
/2
/1
/2
/2
/2
B
/2
B
/2
/2
/2
/2
T
/2
/2
/2
/1
/1
/1
T
/2
/1
/1
/1
/1
/2
/6
"Ø
"Ø
/4
"Ø
/3
L-
R A D
IA
N T
H
EA
T
LI
N E
V O
LT
A G
E
TH
ER
M
O S
TA
T A N D
E M
C S R
EL
A Y R H Z
O N E
/4
H W
R U
P
/4
H W
S U
P
R A D
IA
N T
H
EA
T
LI
N E
V O
LT
A G
E
TH
ER
M
O S
TA
T A N D
E M
C S R
EL
A Y
R H Z
O N E
HOT WATER FINNED
TUBE RADIATION
HOT WATER
CABINET HEATERHOT WATER FINNED
TUBE RADIATION
HOT WATER
CABINET HEATER
HOT WATER DUCT
HEATING COILHOT WATER DUCT
HEATING COIL
HOT WATER DUCT
HEATING COIL
/2
/2
/2
/2
/2 " U
P A B O
V E
W A
LK
W A Y
C O
N C
R
ET
E
PA
D
C O
N C
R
ET
E
PA
D
R H Z
O N E
T H C -1
1 S
R H Z
O N E
R H Z
O N E
R S P
IP
IN
G T
O C
O N D
EN
S
IN
G U N
IT
O N R
O O
F
R L
PI
PI
N G
T O
C O
N D
EN
S
IN
G U N
IT
O N R
O O
F
R S P
IP
IN
G U
P
TH
R U R
O O
F
TO
C O
N D
EN
S
IN
G
U N
IT
O N R
O O
F
R S P
IP
IN
G U
P
TH
R U R
O O
F
TO
C O
N D
EN
S
IN
G
U N
IT
O N R
O O
F
C O
N C
R
ET
E
PA
D
HOT WATER DUCT
HEATING COIL (TYP 2)
E
/6
E
/8
" D
EE
P
PL
EN
U M
FU
LL
S
IZ
E O
F
LO
U V
ER
" D
EE
P
PL
EN
U M
FU
LL
S
IZ
E O
F
LO
U V
ER
PA
R A
LL
EL
B
LA
D
E O
U
TS
ID
E
A
IR
D A M
PE
R
PA
R A
LL
EL
B
LA
D
E R
ET
U R N A
IR
D
A M
PE
R
PA
R A
LL
EL
B
LA
D
E O
U
TS
ID
E
A
IR
D A M
PE
R
/1
" D
EE
P
PL
EN
U M
F U
LL
S
IZ
E O
F
LO
U V
ER
D A M
PE
R A
T
C
FM
B A R O
M
ET
R
IC
B A C
KD
R A
FT
D A M
PE
R
B A R O
M
ET
R
IC
B A C
KD
R A
FT
D A M
PE
R
/4
/4
1"
R A D
IA
N T
H
EA
T
LI
N E
V O
LT
A G
E
TH
ER
M
O S
TA
T A N D
E M
C S R
EL
A Y
R A D
IA
N T
H
EA
T
LI
N E
V O
LT
A G
E
TH
ER
M
O S
TA
T A N D
E M
C S R
EL
A Y
R A D
IA
N T
H
EA
T
LI
N E
V O
LT
A G
E
TH
ER
M
O S
TA
T A N D
E M
C S R
EL
A Y
B
FP
UH
-1
G A S -F
IR
ED
U N
IT
H
EA
TE
R
C O
N D
EN
S
IN
G B O
IL
ER
C O
N D
EN
S
IN
G B O
IL
ER
LO
W
V O
LT
A G
E H
EA
TI
N G
TH
ER
M O
S
TA
T
FO
R U
H -1
V
O
LT
S
IN
G
LE
-P H A S E
B O
IL
ER
P U M
PS
"Ø E
XH
A U S T V
EN
T D U C T
/2
/4
" M A
KE
U P
W A
TE
R L
IN
E
124A
File details come from the government source that posted it. Updated .