Flooring Specification Peterson AFB Bldg. 350 Peterson AFB, CO 80914
Carpet:
Shaw Industries/Contract Group 616 East Walnut Ave.
Dalton, GA 30721 800-356-7429, fax 800-421-7429
Carpet specification shall match facility standard as follows.
Shaw Style: Stereo Tile EW24 59250 24”x24” Color: Surf #50100 Construction: Multi-level/patterned loop Fiber: soil protection, 36% yarn dyed/61% solution dyed Gauge: 1/12” Stitches per inch: 10.0 Tufted Weight: 26 oz/yd Density: 178,932 oz/sy Finished Pile thickness: 0.136” Warranty: Lifetime commercial Limited Backing: Ecoworx tile/recycled content Installation Type: Monolithic
Carpet Code Requirements:
Colorfastness. Colorfastness to light (fading) shall comply with American Association of Textile Chemists and Colorists (AATCC) Test Method (TM) 16E, Colorfastness to Light, and will have a minimum of 4 after 40 AATCC fading units using the AATCC gray scale for color change.
Maximum rating for Electrostatic Propensity:
• 3.5 kilovolts (kV) or less for general commercial areas.
• 2.0 kV or less for critical environments (such as equipment/technical rooms of communication facilities) as tested by the AATCC TM 134-1996, Electrostatic Propensity of Carpets.
Carpet for all areas except corridors must conform to CFR Part 1630, Standard for the Surface Flammability of Carpets and Rugs (FF 1-70) (Pill Test).
Carpet and carpet systems (carpet and pad) for corridors must meet ASTM E648-00, Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source, and the following criteria:
• Minimum average critical radiant flux of 0.45 watt per square centimeter (Class I) or greater within fire egress routes in unaccompanied personnel housing, child development centers, detention and correctional facilities, lodging facilities, and hospitals. Note: If protected by a sprinkler system, Class II may be installed. • Minimum average critical radiant flux of 0.22 watt per square centimeter (Class II) in all other facilities.
Flammability tests from foreign countries are accepted for carpet and carpet tiles if they exceed or conform to the tests listed in paragraphs 9.4.8.3.1 and 9.4.8.3.2.
Appearance Retention Rating (ARR) shall meet a heavy classification of 3.0 – 3.5 ARR.
The ARR scale must be used in accordance with the recommended practice outlined in CRI TM-101, Assessment of Carpet Surface Appearance Change Using the CRI Reference Scales.
Indoor Air Quality. Carpet should bear the CRI “Green Label” for Indoor Air Quality (IAQ) testing
Corridor Rubber Base:
Specification Rubber Base/matches existing in facility:
Manufacturer: Johnsonite 4” cove Color Burnt Umber #63 Cove Base size 4” x full rolls (not lengths) – Material shall be Rubber.
Command Suite (Rooms 2049, 2050, 2052, 2052, 2053, 2054, 2056) Rubber Base:
Johnsonsite Diplomat - Color Burnt Umber #63
Rubber Stair Flooring and Tiles:
Manufacturer: Flexco Spextone Rubber Treads/risers 1/8” gauge color/Charcoal with Black Dahlia, DOE 03 Heavy duty Radial II one-piece tread with riser 1701 & 1776 with visually impaired contract strip. Rubber tiles shall match color and 1/8” gauge.
Follow all manufacturer’s requirements for proper installation methods and approved manufacturer adhesives.