About this file
This is a Department of the Air Force memorandum from the 86th Airlift Wing (USAFE) dated 15 September 2025, detailing salient characteristics for a generator monitoring system. The technical specifications include requirements for 46 generator output systems with 1 shop receiver, featuring a 1 sensor system per generator with SMS-enabled device communication over LTE or higher network.
Key system requirements include: SMS capability to simultaneously monitor 5 sensor inputs per generator, a central monitoring system that can receive all generator site system inputs, comprehensive software and licenses for system notifications, and plug-and-play hardware/software integration. The document also specifies installation of all sensors with functional checks and requires a minimum of two personnel trained on system operation upon completion. The memorandum is addressed to 700 CONS (likely a contracting squadron) and appears to be outlining technical specifications for a monitoring system procurement.