This document appears to be an attachment related to a federal contract opportunity for rapidly deployable, all-weather shelter systems. The key requirements are for a 400 sq. ft. inflatable air beam shelter system that can be deployed quickly by 2 personnel, transported on a single 463L pallet, and withstand a variety of environmental conditions including hot, cold, rain, wind, snow, and sand. The shelter must have features such as removable flooring, dual-zipper doors, screened windows, utility ports, and equipment hanging points. It must also include accessories like an inflator/deflator, transport bag, and maintenance kit. The related federal contract opportunity is for "MUNS Mobility Tents" issued by the Department of the Air Force Pacific Air Forces. The solicitation number is F1W2A44200AW03.

View the file

Other files

File Type Posted
Attachment 2 - Price Schedule UPDATED.pdf PDF
Combo Synopsis Solicitation Amendment.pdf PDF
Attachment 2 - Price Schedule.pdf PDF
attachment 1.pdf PDF
Combo Synopsis Solicitation.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

UPDATED SAILENT CHARACTERISTICS.

3 MUNS Combat Plans and Training requires rapidly deployable, all weather shelter systems for working with sensitive equipment in austere environments. Weather conditions at ACE locations are unknown, and these structures will provide a covered space for sensitive test equipment as well as an area that maintenance can be performed even during inclement weather. The ZUMRO Model 400 Shelter System OR EQUAL is ideal for being able to deploy quickly and to allow necessary maintenance and testing to occur in ACE environments.

2.The Shelter System must have the ability to be deployed quickly and provide a highly usable space, sheltered from inclement weather is required. The structures must be large enough to house sensitive equipment as well as have room for maintenance activities to be performed. The following are characteristics the minimum specs required:

a. 400 SQ FT at 21'L x 20'W x 10.7'H (EXT) and 21'L x 19'W x 10'H (INT), Low-Pressure Inflatable Air beam Shelter System.

b. Color Options: Desert Sand

c. Deployable by 2 personnel in under 5 minutes

d. Packed Dimensions: 40''L x 30''W x 24''H at 220 LBS (Shelter Only).

e. Features: Removable Floor, Universal Quick Connect Panel w/ adapter collar (x2), 6'x3' dual-zipper door (x2), 3'x2' screened windows with exterior privacy cover and tie-ups (x4), 10''-16'' utility ports w/ drawstring closure including stacked utility ports on all corners (x12), eave vent screens w/ covers on front and back (x4), high-capacity equipment hanging points at 65'' (x10), cross beam retainer straps (x2), exterior frame anchor points (x10), high wind tie-downs (x4); Included accessories: 110V inflator/deflator w/ hose, heavy-duty transport bag w/ cinch straps and carry handles, and maintenance kit.

f. Heavy Duty (MILSPEC) Canopy

g. LED Lighting System w/ Control Box

h. Anchor Bladder Set: QTY 2 21' Bladders @ 120 GAL each

i. Stake Kit: Qty 2 Stake Package, each with qty 6 Steel Stakes @ 12" x 3/8", qty 6 asphalt stakes @ 18" x 5/8" and includes 3lb Mallet in carry bag

j. System must be rated to withstand multiple environments: both hot and cold, and abilities to provide shelter from rain, wind, snow, and sand.

k. Shelter system must be able to be transported on a single 463L pallet for agile combat employment. Must take up minimum pallet position on aircraft due to mission constraints.