- The hydraulic metal press brake at the Joint Base Charleston Naval Weapons Station Structures Shop is inoperable due to a hydraulic fluid leak.
- The contractor shall diagnose the reason for the machine leak and make the needed repairs according to the Statement of Work.
- All on-site work must be completed during normal duty hours (0700-1600), Monday through Friday.
- During the site visit, it was confirmed that the machine will not hold hydraulic fluid and has not worked for one year. The threaded pieces actively turn but it is unknown if they move up and down. A forklift and requirement owner will be available to assist with moving the machine.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Pictures.docx | DOCX document | |
| SOW v3 Diagnose and Repair Hydraulic Metal Brake.pdf | ||
| Combo Solicitation - FY24 Hydraulic Metal Brake Repair.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
NWS Structures Shop Bldg 37 Site Visit Hydraulic Metal Press Brake Repair Q & A 3 May 2024 0900 Q. Does it work?
A. No, the machine will not hold hydraulic fluid. It leaks as soon as it is turned on.
Q. How long has it been since it worked?
A. One year.
Q. Will the Requirement Owner and a forklift be available to assist with moving the machine?
A. Yes.
Q. During operation, are the threaded pieces actively turning?
A. Yes.
Q. Do the threaded pieces move up and down?
A. Unknown.