Well_Repair_Combined_Synopsis.docx

DOCX document 33 KB Posted

Attached to
Lahontan NFH Well Repairs Federal contract opportunity
Solicitation number
F16PS00247
Issued by
Department of the Interior Fish and Wildlife Service Region 9 Headquarters

About this file

Copy of Combined Synopsis

View the file

Other files for this federal contract opportunity

Other files attached to Lahontan NFH Well Repairs, newest first.
File Type Posted
Douglas_County_WD.pdf PDF
well_3_transfer_switch_.doc DOC document

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

U.S. Fish and Wildlife Service, Lahontan NFHC has a compelling need for electrical automatic transfer switch control panel work on well #3, #4, #6, #7. This well is necessary for safe and reliable operation of the facility. The facility normally has four operational wells, and they are rotated with three wells running with one well as a backup.

The facility requires the following electrical components be installed at well #3. There is an urgent and compelling need to accomplish this repair. The following is a list of components necessary to operate the well in a safe and efficient manner:

1- Replace Generator Automatic Transfer Switch with a General Electric model ZTGAutomatic Transfer Switch ZTG 3 Pole, 4 Wire, Solid Neutral, 300 Amps, Standard automatic transfer switch, rated 480V, 60 Hz, complete with all standard equipment and housed in a NEMA Type 1 enclosure. Programmable Input/Output Module.

The facility requires the following Square D, and General Electric electrical components be installed at well #4. There is an urgent and compelling need to accomplish this repair. The following is a list of components necessary to operate the well in a safe and efficient manner:

1- Replace Motor Circuit Protector (Square D) 2- Replace Non-Reversing Magnetic Motor starter (Square D) 3- Replace Enclosure/Flange mounted disconnect (Square D) 4- Replace Externally mounted on/off switch (Square D) 5- Replace hour meter (Square D) 6- Replace knock down transformers (Square D) 7- Replace Generator Automatic Transfer Switch with a General Electric model ZTGAutomatic Transfer Switch ZTG 3 Pole, 4 Wire, Solid Neutral, 400 Amps, Standard automatic transfer switch, rated 480V, 60 Hz, complete with all standard equipment and housed in a NEMA Type 1 enclosure. Programmable Input/Output Module.

8- Modify generator by installing electronic governor including actuator/controller kit and mag pickup. Install new control panel, new TPS block heater, and add isolation ball valves to engine block.

The facility requires the following Square D, and General Electric electrical components be installed at well #6. There is an urgent and compelling need to accomplish this repair. The following is a list of components necessary to operate the well in a safe and efficient manner:

1- Replace Motor Circuit Protector (Square D) 2- Replace Non-Reversing Magnetic Motor starter (Square D) 3- Replace Enclosure/Flange mounted disconnect (Square D) 4- Replace Externally mounted on/off switch (Square D) 5- Replace hour meter (Square D) 6- Replace knock down transformers (Square D) 7- Replace Generator Automatic Transfer Switch with a General Electric model ZTGAutomatic Transfer Switch ZTG 3 Pole, 4 Wire, Solid Neutral, 400 Amps, Standard automatic transfer switch, rated 480V, 60 Hz, complete with all standard equipment and housed in a NEMA Type 1 enclosure. Programmable Input/Output Module.

The facility requires the following Square D, and General Electric electrical components be installed at well #7. There is an urgent and compelling need to accomplish this repair. The following is a list of components necessary to operate the well in a safe and efficient manner:

1- Replace Motor Circuit Protector (Square D) 2- Replace Non-Reversing Magnetic Motor starter (Square D) 3- Replace Enclosure/Flange mounted disconnect (Square D) 4- Replace Externally mounted on/off switch (Square D) 5- Replace hour meter (Square D) 6- Replace knock down transformers (Square D) 7- Replace Generator Automatic Transfer Switch with a General Electric model ZTGAutomatic Transfer Switch ZTG 3 Pole, 4 Wire, Solid Neutral, 400 Amps, Standard automatic transfer switch, rated 480V, 60 Hz, complete with all standard equipment and housed in a NEMA Type 1 enclosure. Programmable Input/Output Module.

The facility requires the following Square D, and General Electric electrical components be installed at well #7. There is an urgent and compelling need to accomplish this repair. The following is a list of components necessary to operate the well in a safe and efficient manner:

1- Replace Motor Circuit Protector (Square D) 2- Replace Non-Reversing Magnetic Motor starter (Square D) 3- Replace Enclosure/Flange mounted disconnect (Square D) 4- Replace Externally mounted on/off switch (Square D) 5- Replace hour meter (Square D) 6- Replace knock down transformers (Square D) 7- Replace Generator Automatic Transfer Switch with a General Electric model ZTGAutomatic Transfer Switch ZTG 3 Pole, 4 Wire, Solid Neutral, 400 Amps, Standard automatic transfer switch, rated 480V, 60 Hz, complete with all standard equipment and housed in a NEMA Type 1 enclosure. Programmable Input/Output Module.

All work will be performed on site. The address is Well #3 Highway 395, Gardnerville, NV 89410. Telephone 775-265-2425. All work will be inspected by the technical coordinator to ensure electrical system is functioning properly. The work will be performed inside of a permanent structure between the hours of 7a.m and 3p.m. Access to facility will be granted by hatchery personnel.

No further notice will be posted on National Business Center Interior Electronic Acquisition System-Electronic Commerce at http://www.fedbizopps.gov or https://www.fedconnect.net.

The solicitation response date will be by 12:00 pm on approximately 02/25/2016. Interested contractors must be registered in the SAM.gov complete Online Representations and at http://sam.gov.

This is a Set Aside for Small Business. The NAICS is 811310. The small business size standard is $7.5. Service Wage Determination for Douglas County. This will be a "low price technically acceptable” procurement, technically more important than price.

The technical point of contact is Dan Boone at (775) 265-2425, Ext: 30. No site visit is planned call to schedule visit with Dan Boone. Contracting point of contact is Cindy Salazar at (503) 872-2832, cindy_salazar@fws.gov.

File details come from the government source that posted it. Updated .