PROJECT
AREA
VICINITY LOCATION MAP
0' 2500' 5000' 7500'
BETHLEHEM ● PITTSBURGH ● WILKES - BARRE
www.borton-lawson.com
CONSTRUCTION DRAWINGS FOR
PLAINS TOWNSHIP
HUDSON ROAD STREETSCAPE
PREPARED FOR
PLAINS TOWNSHIP BOARD OF COMMISSIONERS
126 NORTH MAIN STREET
PLAINS, PENNSYLVANIA 18705
CONSTRUCTION DRAWINGS
2022-5500-001-400-002
MARCH 26, 2024
NRA
JNF
PL
AI
NS
T
OW
NS
HI
P, LU
ZE
RN
E
CO
UN
TY
, P
EN
NS
YL
VA
NI
A
HU
DS
ON
R
D
ST
RE
ET
SC
AP
E
PL
AI
NS
T
OW
NS
HI
P www.borton-lawson.com
DRAWING TITLE & PROJECT NAME
DRAWING NO.
SEALS
REVISIONS
DRAWN BY
CHECKED BY
DATE
PROJECT NO.
PROJECT STATUS
Th is dr aw ing re pr es en ts a d es ign in ten t a nd co nc ep t o nly
. T his do cu me nt an d a ll a ss oc iat ed do cu me nts ar e p re pa re d f or a sp ec ific si te an d e ve nt, an d i nc or po ra te ca lcu lat ion s a nd m ea su re me nts av ail ab le fro m tim e o f d ra ftin g.
Us e o f th is de sig n i s g ra nte d t o t he cl ien t fo r t he sp ec ifii ed an d n am ed ev en t o nly
2 3 4 5 6 7 8
B
C
D
E
F
A
DA
TE
NO
DE
SC
RI
PT
IO
N
Wilkes-Barre 613 Baltimore Dr. Suite 300
Wilkes-Barre, PA 18702 570-821-1999
C O
M
M O N W E A L T H
O F
REGISTERED
PROFESSIONAL
P E
N N S Y L V A N
I A
ENGINEER
PE081045
NICHOLAS RAY ARGOT
PITTSTON QUADRANGLE
PA ONE CALL SERIAL NO. 20230111159
THE FOLLOWING IS A LIST OF UTILITIES WHICH MAY HAVE
FACILITIES IN THE PROJECT AREA:
AT&T
1100 3RD AVE, ALTOONA, PA. 16602
CONTACT: PAT SUTTON
EMAIL: PS4364@ATT.COM
UGI UTILITIES INC
1 UGI DR, WILKES BARRE, PA. 18711
CONTACT: AMANDA NIXON
EMAIL: anixon@ugi.com
PLAINS TOWNSHIP
126 N MAIN STREET, PLAINS, PA. 18705
CONTACT: PATRICIA SLUHOCKI
EMAIL: psluhocki@plainstownship.org
PLAINS SEWER AUTH OF THE TOWNSHIP OF
195 S RIVER ST, PLAINS, PA. 18705
CONTACT: GLORIA CHIUCCHI
EMAIL: plainstwpsewer@hotmail.com
PPL ELECTRIC UTILITIES CORPORATION
437 BLUE CHURCH RD, PAXINOS, PA. 17860
CONTACT: DOUG HAUPT
EMAIL: dlhaupt@pplweb.com
SERVICE ELECTRIC CABLE TV & COMM
15 J CAMPBELL COLLINS DRIVE, WILKES BARRE, PA. 18702
CONTACT: MIKE LABUDA
EMAIL: labudam@sectv.com
COMPANY: PENNSYLVANIA AMERICAN WATER
2699 STAFFORD AVE, SCRANTON, PA. 18507
CONTACT: MARK BALOH
EMAIL: mark.baloh@amwater.com
CALL BEFORE YOU DIG!
PENNSYLVANIA LAW REQUIRES
3 WORKING DAYS NOTICE FOR
CONSTRUCTION PHASE AND 10 WORKING
DAYS IN DESIGN STAGE - STOP CALL
Pennsylvania One Call System, Inc.
1-800-242-1776
CO
VE
R
SH
EE
T
CS1
GENERAL NOTES:
1. THE PLAN(S) AND TYPICAL SECTIONS DEPICT THE GENERAL LAYOUT, LENGTH, SCOPE AND LIMITS OF
WORK. THEY MAY NOT INDICATE ALL SITE SPECIFIC CONDITIONS THAT WILL NEED TO BE
ADDRESSED ON AN INDIVIDUAL BASIS DURING CONSTRUCTION. CONTRACTOR SHALL BE
RESPONSIBLE TO THOROUGHLY EXAMINE ALL EXISTING CONDITIONS OF THE SITE PRIOR TO
SUBMITTING A BID SO AS TO IDENTIFY ANY SITE SPECIFIC CONDITIONS THAT MAY AFFECT THE BID.
2. CONTRACTOR SHALL BRING TO THE ATTENTION OF THE ENGINEER ANY SITE SPECIFIC CONDITION
THAT MAY REQUIRE SPECIAL ATTENTION DURING CONSTRUCTION PRIOR TO THE COMMENCEMENT
OF WORK.
3. THE CONTRACTOR WILL BE RESPONSIBLE TO CONTACT THE PENNSYLVANIA ONE-CALL NUMBER AT 1-800-242-1776 NOT LESS THAN THREE (3), NOR MORE THAN TEN (10) WORKING DAYS PRIOR TO THE
START OF WORK TO HAVE ALL UTILITIES MARKED IN THE AREAS OF WORK.
4. THE CONTRACTOR WILL BE RESPONSIBLE TO CONTRACT DIRECTLY, ANY UTILITY NOT LISTED ON THE DRAWING, OR NOT ON RECORD WITH THE PENNSYLVANIA ONE-CALL SYSTEM NOT LESS THAN THREE (3), NOR MORE THAN TEN (10) WORKING DAYS PRIOR TO THE START OF WORK TO HAVE ALL
UTILITIES MARKED IN THE AREAS OF WORK.
5. CONTRACTOR SHALL FIELD VERIFY EXISTING SITE CONDITIONS AND UTILITY LOCATIONS PRIOR TO
CONSTRUCTION.
6. CONSTRUCTION SHALL BE LIMITED TO ONE (1) SIDE OF S.R. 2011 (HUDSON ROAD) ON A DAILY BASIS.
AT NO TIME SHALL CONSTRUCTION WORK BE PERMITTED ON BOTH SIDES OF S.R. 2011 (HUDSON ROAD) SIMULTANEOUSLY, UNLESS OTHERWISE DIRECTED BY THE ENGINEER AND AUTHORIZED BY
PENNDOT.
7. IN ADDITION TO THE CONTRACT DOCUMENTS, THIS PROJECT SHALL BE CONSTRUCTED IN
ACCORDANCE WITH PENNSYLVANIA DEPARTMENT OF TRANSPORTATION SPECIFICATIONS
PUBLICATION 408 AND PENNSYLVANIA DEPARTMENT OF TRANSPORTATION STANDARDS FOR
ROADWAY CONSTRUCTION, LATEST EDITIONS, UNLESS OTHERWISE NOTED, SPECIFIED, OR
DIRECTED.
8. DETAILS, OTHER THAN THOSE INDICATED, ARE ON THE FOLLOWING STANDARD DRAWINGS:
RC-28M JUNE 1, 2010 TC-8600 JUNE 13, 2013
RC-64M FEB 19, 2021 TC-8702B JUNE 13, 2013
RC-67M FEB 19, 2021 TC-8716 FEB 21, 2024
TC-8717 JUNE 13, 2013
9. ALL NECESSARY TRAFFIC CONTROL IS THE RESPONSIBILITY OF THE CONTRACTOR AND SHALL BE IN
ACCORDANCE WITH PENNDOT PUBLICATIONS 212, 213, 236, 408.
10. ANY EXISTING HAZARDOUS WASTE (UNDERGROUND TANKS, ASBESTOS) ENCOUNTERED IN THE
PREPARATION OF THE PROJECT SITE MUST BE REMOVED BY A LICENSED HAZARDOUS MATERIAL
CONTRACTOR AND DISPOSED OF AT AN APPROVED FACILITY.
11. CRAFCO SUPERFLEX SHALL BE USED TO SEAL ALL PAVEMENT JOINTS.
12. EXISTING CONDITIONS DEPICTED ON PLAN DWG. NO C201, C202, AND C203, INCLUDING CONTOURS, ARE BASED ON A FIELD SURVEY PERFORMED BY BORTON-LAWSON.
13. THE PENNSYLVANIA DEPARTMENT OF TRANSPORTATION COULD NOT PROVIDE RIGHT-OF-WAY
PLANS FOR STATE ROUTE 2011 (HUDSON RD). THE RIGHT-OF-WAY LINES WERE DEVELOPED FROM
DEEDS, RECORDED MAPS AND FIELD EVIDENCE.
14. THE RESPONSIBILITY FOR ENSURING THAT ALL UTILITY POLES AND FIRE HYDRANTS WITHIN THE
LIMITS OF WORK SCHEDULED FOR RELOCATION ARE COMPLETED SHALL BE THAT OF THE
PERMITTEE. UTILITY POLES AND FIRE HYDRANT(S) MUST BE RELOCATED BEFORE THE START OF
ANY SIDEWALK/CURB WORK. THE UTILITY POLE RELOCATION WILL BE PERFORMED BY THE
APPROPRIATE UTILITY COMPANY.
Sheet List Table Sheet Number Sheet Title
CS1 COVER SHEET
CS2 LEGENDS ABBREVIATIONS AND SYMBOLS
C101 EXISTING CONDITIONS PLAN (E. MERRITT TO HENRY)
C102 EXISTING CONDITIONS PLAN (HENRY TO REAR WILLIAM)
C201 STREETSCAPE PLAN (E. MERRITT TO HENRY)
C202 STREETSCAPE PLAN (HENRY TO REAR WILLIAM)
C203 ENLARGED STREETSCAPE INTERSECTION PLAN
C204 ENLARGED STREETSCAPE INTERSECTION PLAN
C205 ENLARGED DRIVEWAY PLANS
C206 SITE DISTANCES
C900 SITE DETAILS
C901 EROSION AND SEDIMENTATION CONTROL NOTES
C902 EROSION AND SEDIMENTATION CONTROL DETAILS
C903 MAINTENANCE AND PROTECTION OF TRAFFIC
AutoCAD SHX Text
WILKES-BARRE, PA 18702-7903
AutoCAD SHX Text
613 BALTIMORE DRIVE, SUITE 300
AutoCAD SHX Text
PREPARED BY:
AutoCAD SHX Text
BORTON-LAWSON
AutoCAD SHX Text
DATE
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text
DISTRICT EXECUTIVE
AutoCAD SHX Text
RECOMMENDED
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
REGISTERED PROFESSIONAL ENGINEER
AutoCAD SHX Text
PLAINS TOWNSHIP REPRESENTATIVE
AutoCAD SHX Text x
CONSTRUCTION DRAWINGS
2022-5500-001-400-002
MARCH 26, 2024
NRA
JNF
PL
AI
NS
T
OW
NS
HI
P, LU
ZE
RN
E
CO
UN
TY
, P
EN
NS
YL
VA
NI
A
HU
DS
ON
R
D
ST
RE
ET
SC
AP
E
PL
AI
NS
T
OW
NS
HI
P www.borton-lawson.com
DRAWING TITLE & PROJECT NAME
DRAWING NO.
SEALS
REVISIONS
DRAWN BY
CHECKED BY
DATE
PROJECT NO.
PROJECT STATUS
Th is dr aw ing re pr es en ts a d es ign in ten t a nd co nc ep t o nly
. T his do cu me nt an d a ll a ss oc iat ed do cu me nts ar e p re pa re d f or a sp ec ific si te an d e ve nt, an d i nc or po ra te ca lcu lat ion s a nd m ea su re me nts av ail ab le fro m tim e o f d ra ftin g.
Us e o f th is de sig n i s g ra nte d t o t he cl ien t fo r t he sp ec ifii ed an d n am ed ev en t o nly
2 3 4 5 6 7 8
B
C
D
E
F
A
DA
TE
NO
DE
SC
RI
PT
IO
N
Wilkes-Barre 613 Baltimore Dr. Suite 300
Wilkes-Barre, PA 18702 570-821-1999
C O
M
M O N W E A L T H
O F
REGISTERED
PROFESSIONAL
P E
N N S Y L V A N
I A
ENGINEER
PE081045
NICHOLAS RAY ARGOT
LEGEND, ABBREVIATIONS AND SYMBOLS
X X X X x XXX.XX
EOP
LEGAL RIGHT-OF-WAY
OVERHEAD ELEC
FENCE
GUIDERAIL
GAS LINE
ROADWAY CENTERLINE
CURB
EASEMENT LINE
SANITARY LINE
MANHOLE
STORM PIPE
MAJOR CONTOUR
MINOR CONTOUR
SPOT ELEVATION
WATER LINE
BUILDING
WETLAND WITH BUFFER
DECIDUOUS TREE
CONIFEROUS TREE
SHRUB
UTILITY VALVE
BOLLARD
UTILITY POLE
SIGN
MAILBOX
FIRE HYDRANT
LIGHT POLE
SIGNAL MAST ARM
DELTA
ABDN ABANDON
ABUT ABUTMENT
AC ACRES
AD AREA DRAIN
APPROX APPROXIMATE
B/24" BLUE 24"
B/4" BLUE 4"
BC BOTTOM CURB
BCBC BITUMINOUS CONCRETE BASE COARSE
BLDG BUILDING
BFG BELOW FINISHED GRADE
BM BENCH MARK
BOB BOTTOM OF BANK
BOL BOLLARD
BRG BEARING
BVCE BEGIN VERTICAL CURVE ELEVATION
BVCS BEGIN VERTICAL CURVE STATION
BW BOTTOM WALL
CBL CABLE
CHD CHORD
CHWR CHILLED WATER RETURN
CHWS CHILLED WATER SOURCE
CJ CONTROL JOINT
CL CENTER LINE
CMP CORRUGATED METAL PIPE
CMU CONCRETE MASONRY UNIT
CO CLEANOUT
COMM COMMUNICATION
CONC CONCRETE
COND CONDENSATE
CPP CORRUGATED PLASTIC PIPE
CS COATED STEEL
CY CUBIC YARDS
DB DEED BOOK
DEMO DEMOLITION
DI DUCTILE IRON
DIA DIAMETER
DIR DIRECTION
DN DOWN
DWG DRAWING
DWGS DRAWINGS
DY/4" DOUBLE YELLOW 4"
E= EASTING
E & S EROSION AND SEDIMENTATION CONTROL
EA EACH
EBOX ELECTRICAL BOX
EJ EXPANSION JOINT
EL ELEVATION
EOP EDGE OF PAVE
EOS EDGE OF SHOULDER
EVCE END VERTICAL CURVE ELEVATION
EVCS END VERTICAL CURVE STATION
EXIST EXISTING
FES FLARED END SECTION
FF FINISH FLOOR
FG FINISH GRADE
FH FIRE HYDRANT
FM FORCE MAIN
FND FOUND
FRP FIBERGLASS REINFORCED PIPE
FS FIRE SERVICE
FT FEET
G GAS
GND GROUND
GPM GALLONS PER MINUTE
GV GAS VALVE
HC HYDRAULIC CONDUCTIVITY
HOP HIGHWAY OCCUPANCY PERMIT
HT HEIGHT
ID INSIDE DIAMETER
IN INCHES
INV INVERT
JB JUNCTION BOX
LAT LATITUDE
LF LINEAL FEET
LOD LIMIT OF DISTURBANCE
LONG LONGITUDE
LP LIGHT POLE
LT LEFT
LVC LENGTH VERTICAL CURVE
MAX MAXIMUM
MB MAILBOX
MFR MANUFACTURER
MH MANHOLE
MIN MINIMUM
MON MONUMENT
MPT MAINTENANCE AND PROTECTION OF TRAFFIC
N/F NOW OR FORMERLY
N NORTHING
NPDES NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM
OC ON CENTER
OD OUTSIDE DIAMETER
OFF OFFSET
OH OVERHEAD
OHE OVERHEAD ELECTRIC
OHW OVERHEAD WIRE
OHWM ORDINARY HIGH WATER MARK
PCSM POST CONSTRUCTION STORM WATER MANAGEMENT
PG PAGE
PI POINT OF INTERSECTION
PIN PROPERTY IDENTIFICATION NUMBER
PL PROPERTY LINE
PNT POINT
POB POINT OF BEGINNING
POE POINT OF ENDING
PPC PREPAREDNESS PREVENTION AND CONTINGENCY
PRC POINT REVERSE CURVE
PRV PRESSURE REDUCING VALVE
PT POINT TANGENCY
PVC POINT OF VERTICAL CURVE
PVI POINT OF VERTICAL INTERSECTION
R/W RIGHT-OF-WAY
R RADIUS
RA ROCK APRON
RB RECORD BOOK
RCE ROCK CONSTRUCTION ENTRANCE
RCP REINFORCED CONCRETE PIPE
RR RAILROAD
S SLOPE
SAN SANITARY
SEG SEGMENT
SF SQUARE FEET
SCH SCHEDULE
SLCPP SMOOTH LINE CORRUGATED POLYETHYLENE PIPE
SR STATE ROUTE
STL STEEL
STM STEAM
SY SQUARE YARDS
T= TANGENT
TB TEST BORING
TBA TO BE ABANDONDED
TBR TO BE REMOVED
TC TOP CURB
TD TRENCH DRAIN
TEL TELEPHONE
TEMP TEMPORARY
TP TEST PIT
TWP TOWNSHIP
TW TOP WALL
TYP TYPICAL
UG UNDERGROUND
UGE UNDERGROUND ELECTRIC
UPOLE UTILITY POLE
UTIL UTILITIES
W WATER
W/24" WHITE 24"
W/4" WHITE 4"
WSE WATER SURFACE ELEVATION
WV WATER VALVE
WWTP WASTE WATER TREATMENT PLANT
YR YEAR
PROPERTY LINE
DRAINAGE SWALE
SANITARY FORCE MAIN LINE
STORM INLET
EXISTING PROPOSEDITEM
CONCRETE AREA
TRAFFIC SIGNAL JUNCTION BOX
LE
GE
ND
S
AB
BR
EV
IA
TI
ON
S
AN
D
SY
M
BO
LS
CS2
AutoCAD SHX Text x XXX.XX
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text P
AutoCAD SHX Text L
AutoCAD SHX Text
MB
SFM
(TO BE RELOCATED) (TO BE RELOCATED)
AREA OF EXISTING
SIDEWALK
TO BE REMOVED AND
REPLACED TYP.
(TO BE RELOCATED)
(TO BE ERADICATED)
0' 60'40'20'
PLAN
GRAPHIC SCALE IN FEET NOTES:
1. ANY EXISTING RAINWATER CONDUCTOR ROOF LEADER DOWNSPOUT EXTENSIONS WHICH ARE IN
DIRECT CONFLICT OR INTERFERE WITH THE CONSTRUCTION OF THE CURB AND SIDEWALK
IMPROVEMENTS SHALL BE REMOVED TO THE EXTENT THAT THEY WILL NO LONGER BE IN CONFLICT WITH THE PROPOSED CONSTRUCTION AND WILL DISCHARGE ON THE GROUND SURFACE ADJACENT TO THE STRUCTURE WHICH THEY ARE APPURTENANT TO. THIS WORK SHALL BE INCIDENTAL TO THE
PROPOSED CONSTRUCTION.
2. ALL BIT CONC DRIVEWAYS SHALL BE SAWCUT FOR THE ENTIRE WIDTH OF THE DRIVEWAY FOR THE REMOVAL OF EXISTING PAVEMENT REQUIRED TO INSTALL THE SIDEWALKS AND SHALL BE INCIDENTAL TO SIDEWALK CONSTRUCTION. ADDITIONAL SAWCUTTING REQUIRED FOR FINAL BIT CONC DRIVEWAY
PERMANENT PAVEMENT REPLACEMENT/RESTORATION SHALL BE INCIDENTAL TO THE PERMANENT
PAVEMENT REPLACEMENT/RESTORATION. LIMIT OF BIT CONC PAVED DRIVEWAY RESTORATION SHALL BE A MINIMUM OF 2 FEET AND MAXIMUM OF 5 FEET INTO DRIVEWAY, UNLESS OTHERWISE DIRECTED BY ENGINEER. ACTUAL LIMIT OF PAVEMENT RESTORATION TO BE FIELD DETERMINED BY ENGINEER. FOR
BIDDING PURPOSES, FIVE (5) FEET SHALL BE CONSIDERED.
3. CONTRACTOR SHALL BE RESPONSIBLE TO COORDINATE WITH THE RESPECTIVE UTILITY COMPANIES IN CONNECTION WITH THE HORIZONTAL RELOCATION AND VERTICAL GRADE ADJUSTMENT OF ANY GAS AND/OR WATER SERVICE LATERAL SHUTOFF VALVES OR METER ACCESS CASTINGS WHICH MAY BE
REQUIRED.
4. THE LEGAL RIGHT-OF-WAY WIDTH ON S.R. 2011 (HUDSON ROAD) IS FIFTY (50) FEET.
5. CONTRACTOR SHALL PROTECT IRON PINS OR OTHER EXISTING PROPERTY CORNER SURVEY MARKERS
AND SHALL BE RESPONSIBLE TO HAVE IRON PINS RESET BY A PROFESSIONAL LAND SURVEYOR, LICENSED AND REGISTERED IN THE STATE OF PENNSYLVANIA, IF IT IS DISTURBED DURING
CONSTRUCTION.
6. THERE ARE NO SIGNS THAT WILL REQUIRE RELOCATION WITHIN THE LIMITS OF WORK.
7. POSTED SPEED LIMIT ON HUDSON ROAD (S.R. 2011) IS 25 M.P.H.
CONSTRUCTION DRAWINGS
2022-5500-001-400-002
MARCH 26, 2024
NRA
JNF
PL
AI
NS
T
OW
NS
HI
P, LU
ZE
RN
E
CO
UN
TY
, P
EN
NS
YL
VA
NI
A
HU
DS
ON
R
D
ST
RE
ET
SC
AP
E
PL
AI
NS
T
OW
NS
HI
P www.borton-lawson.com
DRAWING TITLE & PROJECT NAME
DRAWING NO.
SEALS
REVISIONS
DRAWN BY
CHECKED BY
DATE
PROJECT NO.
PROJECT STATUS
Th is dr aw ing re pr es en ts a d es ign in ten t a nd co nc ep t o nly
. T his do cu me nt an d a ll a ss oc iat ed do cu me nts ar e p re pa re d f or a sp ec ific si te an d e ve nt, an d i nc or po ra te ca lcu lat ion s a nd m ea su re me nts av ail ab le fro m tim e o f d ra ftin g.
Us e o f th is de sig n i s g ra nte d t o t he cl ien t fo r t he sp ec ifii ed an d n am ed ev en t o nly
2 3 4 5 6 7 8
B
C
D
E
F
A
DA
TE
NO
DE
SC
RI
PT
IO
N
Wilkes-Barre 613 Baltimore Dr. Suite 300
Wilkes-Barre, PA 18702 570-821-1999
C O
M
M O N W E A L T H
O F
REGISTERED
PROFESSIONAL
P E
N N S Y L V A N
I A
ENGINEER
PE081045
NICHOLAS RAY ARGOT
SH
EE
T C
SH
EE
T C
EX
IS
TI
NG
C
ON
DI
TI
ON
S
PL
AN
(E . M
ER
RI
TT
T
O
HE
NR
Y)
C101
LEGEND
DRIVEWAY KEY NUMBER (REFER TO
DRIVEWAY KEY NUMBER TABULATION - THIS
SHEET)
MATCHLINE
SHEET CXXX
SHEET CXXX
CALL BEFORE YOU DIG!
PENNSYLVANIA LAW REQUIRES
3 WORKING DAYS NOTICE FOR
CONSTRUCTION PHASE AND 10 WORKING
DAYS IN DESIGN STAGE - STOP CALL
Pennsylvania One Call System, Inc.
1-800-242-1776
PA ONE CALL SERIAL NO. 20230111159
AutoCAD SHX Text
ATTCH 52410 N40921 GJI1
AutoCAD SHX Text
ATTCH 52401 N40921 HOPKINS ST TAP 100K "SLOW CHURCH ZONE"
AutoCAD SHX Text
PPL 52401 N40928 GI55
AutoCAD SHX Text
GUY WIRES
AutoCAD SHX Text
ATTCH 52420 N40955 GI 60632 " NO PARKING"
AutoCAD SHX Text
PPL 52415 N40965
AutoCAD SHX Text
INLET
AutoCAD SHX Text
INLET
AutoCAD SHX Text
EAST MERRITT STREET
AutoCAD SHX Text
INLET
AutoCAD SHX Text
GV'S
AutoCAD SHX Text
RESIDENTIAL& COMMERCIAL STRUCTURE
AutoCAD SHX Text
GV
AutoCAD SHX Text
GV
AutoCAD SHX Text
WV
AutoCAD SHX Text
SAN MH
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
GV
AutoCAD SHX Text
WM'S
AutoCAD SHX Text
INLET
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
GV
AutoCAD SHX Text
ATKINSON LN
AutoCAD SHX Text
HENRY ST
AutoCAD SHX Text
WV
AutoCAD SHX Text
INLET
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
GV
AutoCAD SHX Text
INLET
AutoCAD SHX Text
DEAD POLE
AutoCAD SHX Text
PPL 52424 N40961
AutoCAD SHX Text
SR 2011 SEG 0070 OFF 719 ASPH. DRIVE
AutoCAD SHX Text
SAN MH RIM: 622.28' INV(NE): 612.18' INV(SW): 612.18' INV(NW): 612.28'
AutoCAD SHX Text
8" PVC
AutoCAD SHX Text
STORM MH
AutoCAD SHX Text
CONC. WALK
AutoCAD SHX Text
CONC. WALK
AutoCAD SHX Text
PPL 52405 N40927 G156
AutoCAD SHX Text
INLET
AutoCAD SHX Text
CONC. WALK
AutoCAD SHX Text
RESIDENTIAL STRUCTURE
AutoCAD SHX Text
STORM MH
AutoCAD SHX Text
STORM MH
AutoCAD SHX Text
SAN MH
AutoCAD SHX Text
INLET
AutoCAD SHX Text
CONC. WALK
AutoCAD SHX Text
STORM MH
AutoCAD SHX Text
INLET
AutoCAD SHX Text
ATTCH52412 N40940 1971
AutoCAD SHX Text
STORM MH
AutoCAD SHX Text
ASPHALT WALK
AutoCAD SHX Text
INLET
AutoCAD SHX Text
INLET
AutoCAD SHX Text
INLET
AutoCAD SHX Text
STORM MH
AutoCAD SHX Text
STORM MH
AutoCAD SHX Text #44
AutoCAD SHX Text #48/#50
AutoCAD SHX Text #60
AutoCAD SHX Text #64
AutoCAD SHX Text #68
AutoCAD SHX Text #72
AutoCAD SHX Text #52/#54
AutoCAD SHX Text #34/#36
AutoCAD SHX Text #30
AutoCAD SHX Text #26/#28
AutoCAD SHX Text
INLET
AutoCAD SHX Text
SR 2011 SEG 0070 OFF 1008
AutoCAD SHX Text
SR 2011 SEG 0070 OFF 659 GRAVEL PARKING LOT
AutoCAD SHX Text
HUDSON ROAD (SR 2011)
AutoCAD SHX Text 10"
AutoCAD SHX Text 12"
AutoCAD SHX Text 30"
AutoCAD SHX Text 30"
AutoCAD SHX Text
HEDGES
AutoCAD SHX Text
BL BENCHMARK HYDRANT NW BOLT ELEVATION: 622.82'
AutoCAD SHX Text #60
AutoCAD SHX Text #64
AutoCAD SHX Text
WV'S
AutoCAD SHX Text
WV
AutoCAD SHX Text
GV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
PPL 52416 N40947 GI 59 " NO PARKING"
AutoCAD SHX Text
PPL 52408 N40933
AutoCAD SHX Text
4" REVEAL SIDEWALK
AutoCAD SHX Text
4" REVEAL SIDEWALK
AutoCAD SHX Text
4" REVEAL SIDEWALK
AutoCAD SHX Text
STOP SIGN
AutoCAD SHX Text
NO PARKING SIGN
AutoCAD SHX Text
"NO PARKING HERE TO CORNER" SIGN
AutoCAD SHX Text
"NO PARKING HERE TO CORNER" SIGN
AutoCAD SHX Text
STOP SIGN
AutoCAD SHX Text
CROSSWALK PAVEMENT MARKINGS
AutoCAD SHX Text
WEST DRIVEWAYS
AutoCAD SHX Text
LEGEND SYMBOL
AutoCAD SHX Text
HOUSE NUMBER
AutoCAD SHX Text
OWNER
AutoCAD SHX Text
DRIVEWAY PERMIT
AutoCAD SHX Text
SEGMENT
AutoCAD SHX Text
OFFSET
AutoCAD SHX Text
APPLICATION NUMBER
AutoCAD SHX Text
AutoCAD SHX Text #64
AutoCAD SHX Text
LAWRENCE & BARBARA GREBEY
AutoCAD SHX Text
MINIMUM USE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 319447
AutoCAD SHX Text
AutoCAD SHX Text #68
AutoCAD SHX Text
GERALD & THERESA HANCHULAK
AutoCAD SHX Text
LOW VOLUME
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 319527
AutoCAD SHX Text
DRIVEWAY KEY NUMBER TABULATION
AutoCAD SHX Text
AutoCAD SHX Text #21
AutoCAD SHX Text
EXISTING POSTAL ADDRESS NUMBER
AutoCAD SHX Text
(TO BE RELOCATED)
(TO BE RELOCATED)
AREA OF EXISTING SIDEWALK TO BE
REMOVED AND REPLACED TYP.
(TO BE REMOVED)
(TO BE REMOVED)
0' 60'40'20'
PLAN
GRAPHIC SCALE IN FEET
NOTES:
1. ANY EXISTING RAINWATER CONDUCTOR ROOF LEADER DOWNSPOUT EXTENSIONS WHICH ARE IN
DIRECT CONFLICT OR INTERFERE WITH THE CONSTRUCTION OF THE CURB AND SIDEWALK
IMPROVEMENTS SHALL BE REMOVED TO THE EXTENT THAT THEY WILL NO LONGER BE IN CONFLICT WITH THE PROPOSED CONSTRUCTION AND WILL DISCHARGE ON THE GROUND SURFACE ADJACENT TO THE STRUCTURE WHICH THEY ARE APPURTENANT TO. THIS WORK SHALL BE INCIDENTAL TO THE
PROPOSED CONSTRUCTION.
2. ALL BIT CONC DRIVEWAYS SHALL BE SAWCUT FOR THE ENTIRE WIDTH OF THE DRIVEWAY FOR THE REMOVAL OF EXISTING PAVEMENT REQUIRED TO INSTALL THE SIDEWALKS AND SHALL BE INCIDENTAL TO SIDEWALK CONSTRUCTION. ADDITIONAL SAWCUTTING REQUIRED FOR FINAL BIT CONC DRIVEWAY
PERMANENT PAVEMENT REPLACEMENT/RESTORATION SHALL BE INCIDENTAL TO THE PERMANENT
PAVEMENT REPLACEMENT/RESTORATION. LIMIT OF BIT CONC PAVED DRIVEWAY RESTORATION SHALL BE A MINIMUM OF 2 FEET AND MAXIMUM OF 5 FEET INTO DRIVEWAY, UNLESS OTHERWISE DIRECTED BY ENGINEER. ACTUAL LIMIT OF PAVEMENT RESTORATION TO BE FIELD DETERMINED BY ENGINEER. FOR
BIDDING PURPOSES, FIVE (5) FEET SHALL BE CONSIDERED.
3. CONTRACTOR SHALL BE RESPONSIBLE TO COORDINATE WITH THE RESPECTIVE UTILITY COMPANIES IN CONNECTION WITH THE HORIZONTAL RELOCATION AND VERTICAL GRADE ADJUSTMENT OF ANY GAS AND/OR WATER SERVICE LATERAL SHUTOFF VALVES OR METER ACCESS CASTINGS WHICH MAY BE
REQUIRED.
4. THE LEGAL RIGHT-OF-WAY WIDTH ON S.R. 2011 (HUDSON ROAD) IS FIFTY (50) FEET
5. CONTRACTOR SHALL PROTECT IRON PINS OR OTHER EXISTING PROPERTY CORNER SURVEY MARKERS
AND SHALL BE RESPONSIBLE TO HAVE IRON PINS RESET BY A PROFESSIONAL LAND SURVEYOR, LICENSED AND REGISTERED IN THE STATE OF PENNSYLVANIA, IF IT IS DISTURBED DURING
CONSTRUCTION.
6. THERE ARE NO SIGNS THAT WILL REQUIRE RELOCATION WITHIN THE LIMITS OF WORK.
7. POSTED SPEED LIMIT ON HUDSON ROAD (S.R. 2011) IS 25 M.P.H.
CONSTRUCTION DRAWINGS
2022-5500-001-400-002
MARCH 26, 2024
NRA
JNF
PL
AI
NS
T
OW
NS
HI
P, LU
ZE
RN
E
CO
UN
TY
, P
EN
NS
YL
VA
NI
A
HU
DS
ON
R
D
ST
RE
ET
SC
AP
E
PL
AI
NS
T
OW
NS
HI
P www.borton-lawson.com
DRAWING TITLE & PROJECT NAME
DRAWING NO.
SEALS
REVISIONS
DRAWN BY
CHECKED BY
DATE
PROJECT NO.
PROJECT STATUS
Th is dr aw ing re pr es en ts a d es ign in ten t a nd co nc ep t o nly
. T his do cu me nt an d a ll a ss oc iat ed do cu me nts ar e p re pa re d f or a sp ec ific si te an d e ve nt, an d i nc or po ra te ca lcu lat ion s a nd m ea su re me nts av ail ab le fro m tim e o f d ra ftin g.
Us e o f th is de sig n i s g ra nte d t o t he cl ien t fo r t he sp ec ifii ed an d n am ed ev en t o nly
2 3 4 5 6 7 8
B
C
D
E
F
A
DA
TE
NO
DE
SC
RI
PT
IO
N
Wilkes-Barre 613 Baltimore Dr. Suite 300
Wilkes-Barre, PA 18702 570-821-1999
C O
M
M O N W E A L T H
O F
REGISTERED
PROFESSIONAL
P E
N N S Y L V A N
I A
ENGINEER
PE081045
NICHOLAS RAY ARGOT
SH
EE
T C
SH
EE
T C
EX
IS
TI
NG
C
ON
DI
TI
ON
S
PL
AN
(H
EN
RY
T
O
RE
AR
W
IL
LI
AM
C102
LEGEND
DRIVEWAY KEY NUMBER (REFER TO
DRIVEWAY KEY NUMBER TABULATION - THIS
SHEET)
MATCHLINE
SHEET CXXX
SHEET CXXX
CALL BEFORE YOU DIG!
PENNSYLVANIA LAW REQUIRES
3 WORKING DAYS NOTICE FOR
CONSTRUCTION PHASE AND 10 WORKING
DAYS IN DESIGN STAGE - STOP CALL
Pennsylvania One Call System, Inc.
1-800-242-1776
PA ONE CALL SERIAL NO. 20230111159
AutoCAD SHX Text
REAR WILLIAM STREET
AutoCAD SHX Text
CROW STREET
AutoCAD SHX Text
SIGN TYP.
AutoCAD SHX Text
ATTCH 52449 N40969
AutoCAD SHX Text
GUY WIRE
AutoCAD SHX Text
PPL 52457 N40980
AutoCAD SHX Text
PPL 52427 N40965 GI 62
AutoCAD SHX Text
SAN MH
AutoCAD SHX Text
SAN MH
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
GV
AutoCAD SHX Text
GV
AutoCAD SHX Text
RESIDENTIAL STRUCTURE
AutoCAD SHX Text
RESIDENTIAL STRUCTURE
AutoCAD SHX Text
RESIDENTIAL STRUCTURE
AutoCAD SHX Text
PORCH
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
GV
AutoCAD SHX Text
INLET
AutoCAD SHX Text
INLET
AutoCAD SHX Text
SAN MH
AutoCAD SHX Text
CONCRETE DRIVEWAY
AutoCAD SHX Text
INLET
AutoCAD SHX Text
INLET
AutoCAD SHX Text
INLET
AutoCAD SHX Text
INLET
AutoCAD SHX Text
CONC. PATIO
AutoCAD SHX Text
RESIDENTIAL STRUCTURE
AutoCAD SHX Text
SAN MH
AutoCAD SHX Text
SAN MH
AutoCAD SHX Text
STORM MH
AutoCAD SHX Text
ASPH. DRIVE
AutoCAD SHX Text
ASPH. DRIVE
AutoCAD SHX Text
SAN MH
AutoCAD SHX Text
ATTCH 52452 N40983 27 GI 65
AutoCAD SHX Text
PPL 52436 N40974
AutoCAD SHX Text
PPL 52432 N40972
AutoCAD SHX Text #78/#80
AutoCAD SHX Text #142
AutoCAD SHX Text #86/#88
AutoCAD SHX Text #90/#92
AutoCAD SHX Text #96
AutoCAD SHX Text #102
AutoCAD SHX Text #73
AutoCAD SHX Text #77
AutoCAD SHX Text #79
AutoCAD SHX Text #1
AutoCAD SHX Text #5
AutoCAD SHX Text #93
AutoCAD SHX Text #95
AutoCAD SHX Text
PENNSYLVANIA DEPARTMENT OF TRANSPORTATION RIGHT-OF-WAY LINE TYP.
AutoCAD SHX Text
SR 2011 SEG 0070 OFF 355
AutoCAD SHX Text
SR 2011 SEG 0070 OFF 553
AutoCAD SHX Text
PROPERTY LINE TYP.
AutoCAD SHX Text
PPL 52433 N40971
AutoCAD SHX Text
PPL 52446N40978 GI 64 26.5
AutoCAD SHX Text
PPL 52442 N440972
AutoCAD SHX Text 30"
AutoCAD SHX Text 24"
AutoCAD SHX Text 24"
AutoCAD SHX Text
CONC. DRIVE
AutoCAD SHX Text
HYD
AutoCAD SHX Text
WV
AutoCAD SHX Text
GV
AutoCAD SHX Text
4" REVEAL SIDEWALK
AutoCAD SHX Text
4" REVEAL SIDEWALK
AutoCAD SHX Text
3" REVEAL CURB
AutoCAD SHX Text
4" REVEAL SIDEWALK
AutoCAD SHX Text
1" REVEAL SIDEWALK
AutoCAD SHX Text
3" REVEAL CURB
AutoCAD SHX Text
4" REVEAL CURB
AutoCAD SHX Text
NO ID
AutoCAD SHX Text
NO ID
AutoCAD SHX Text
AutoCAD SHX Text #21
AutoCAD SHX Text
EXISTING POSTAL ADDRESS NUMBER
AutoCAD SHX Text
WEST DRIVEWAYS
AutoCAD SHX Text
LEGEND SYMBOL
AutoCAD SHX Text
HOUSE NUMBER
AutoCAD SHX Text
OWNER
AutoCAD SHX Text
DRIVEWAY PERMIT
AutoCAD SHX Text
SEGMENT
AutoCAD SHX Text
OFFSET
AutoCAD SHX Text
APPLICATION NUMBER
AutoCAD SHX Text
AutoCAD SHX Text #86/#88
AutoCAD SHX Text
MOJICA ROMANO
AutoCAD SHX Text
MINIMUM USE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 319550
DRIVEWAY KEY NUMBER TABULATION
(TO BE RELOCATED)
5.
4'
5.
3'
5.
1'
5.
2'
5.
0'
5.
4'
5.
0'
5.
0' 5.
0'
5.
0'
5.0'
7.0'
5.
0'
9 10
11 14
6" REVEAL
BEGIN CONCRETE CURB
SR 2011 SEG 0070 OFF 985
LIMIT OF WORK:
SR 2011 SEG 0070 OFF 1069
MATCH EXISTING CURB REVEAL
END CONCRETE CURB
SR 2011 SEG 0070 OFF 638
19.0'
10.0' 8.0'
6" REVEAL
CURB
6" REVEAL
CURB
9.0' 24.0'
4.0'
5.0'
6" REVEAL CURB
5.0'
5.3'
5.4'
A
A
B
B
W/6"
PPL 52405
N40927 G156
PROPOSED LOCATION.
GRASS AND SEED AREA
AROUND POLE UPON
INSTALLATION.
PPL ATTCH52412
N40940
PROPOSED LOCATION
PPL 52416N40949 GI 59
(PREVIOUSLY PPL
52416N40947 GI59)
PROPOSED LOCATION
6" REVEAL
BEGIN CONCRETE CURB
SR 2011 SEG 0070 OFF 782
6" REVEAL
END CONCRETE CURB
SR 2011 SEG 0070 OFF 805
5.8'
STOP SIGN
(R1-1)
ONE WAY (R6-1R)*
ONE WAY (R6-1L)*
DO NOT ENTER SIGN (R5-1)
*PLACE ONE WAY SIGNS ON
EITHER SIDE OF SIGN POST
INDICATING NO PERMITTED
ENTRANCE TO ATKINSON LN
FROM HUDSON RD.
R10'
R10'
R10'
R10'
R10'
NO TRUCKS OR
BUSES SIGN
(R5-3-4)
STOP SIGN
(R1-1)
(TO REMAIN)
INSTALL R7-301 SIGN
BELOW EXISTING
"NO PARKING" SIGN
ENSURING THAT ARROWS
ARE ORIENTED PARALLEL
WITH BANK ST
NO PARKING
ZONE
NO PARKING ZONE
NO PARKING ZONE
(TO REMAIN)
INSTALL R7-301 SIGN
BELOW EXISTING
"NO PARKING" SIGN
ENSURING THAT ARROWS
ARE ORIENTED PARALLEL
WITH HUDSON RD
(TO REMAIN)
INSTALL R7-301 SIGN
BELOW EXISTING SIGN
ENSURING THAT ARROWS
ARE ORIENTED PARALLEL
WITH HUDSON RD
NO PARKING (R7-302)*
*INSTALL NO PARKING SIGN
ENSURING THAT ARROWS
ARE ORIENTED PARALLEL
WITH HUDSON RD
NO PARKING (R7-302)*
*INSTALL NO PARKING SIGN
ENSURING THAT ARROWS
ARE ORIENTED PARALLEL
WITH HUDSON RD
4.
0'
4.
0'
0' 60'40'20'
PLAN
5" MIN. CLASS AA CONCRETE
6" PENNDOT NO. 2A CRUSHED
STONE COARSE AGGREGATE
COMPACTED SUBGRADE
VARIES
5.0'-7.0'±
VARIES
11.1' - 15.3'±
VARIES
12.2' - 14.5'±
SOUTH BOUND LANE NORTH BOUND LANE
12"SAWCUT AND SEAL WITH
CRAFCO SUPERFLEX
(TYP. BOTH SIDES)
12"
GRAPHIC SCALE IN FEET
SECTION A-A (WEST SIDE) TYP.
NOT TO SCALE
4" PER FOOT
CONCRETE
CURB
HUDSON ROAD (SR 2011)
TYPICAL ROADWAY SECTION
(LOOKING NORTH)
NOT TO SCALE
PROPOSED
CONCRETE
CURB
PROPOSED
CONCRETE
CURB
PERMANENT PAVEMENT
REPLACEMENT ALONG
NEWLY INSTALLED CURB (TYP)
SEE DETAIL ON DRAWING C900
HORIZONTAL CONTROL
COORDINATES (TYP)
PREMOLDED 1/2" ASPHALT
EXPANSION JOINT FILLER
PERMANENT PAVEMENT
REPLACEMENT ALONG
NEWLY INSTALLED CURB (TYP)
SEE DETAIL ON DRAWING C900
** MAINTAIN EXISTING
CROSS-SLOPE
(TYP. BOTH SIDES)
SOUTH BOUND - WEST SIDE OF
HUDSON ROAD (S.R. 2011)
Point Table
Point #
Northing Easting
HORIZONTAL CONTROL POINT TABLE
NOTES:
1. ALL REQUIRED TOPSOIL, SEED AND MULCH FILL RESTORATION BEHIND NEWLY INSTALLED SIDEWALKS
SHALL BE PLACED WITH A MAXIMUM SLOPE OF 3 HORIZONTAL TO 1 VERTICAL.
2. ANY EXISTING RAINWATER CONDUCTOR ROOF LEADER DOWNSPOUT EXTENSIONS WHICH ARE IN
DIRECT CONFLICT OR INTERFERE WITH THE CONSTRUCTION OF THE CURB AND SIDEWALK
IMPROVEMENTS SHALL BE REMOVED TO THE EXTENT THAT THEY WILL NO LONGER BE IN CONFLICT WITH THE PROPOSED CONSTRUCTION AND WILL DISCHARGE ON THE GROUND SURFACE ADJACENT TO THE STRUCTURE WHICH THEY ARE APPURTENANT TO. THIS WORK SHALL BE INCIDENTAL TO THE
PROPOSED CONSTRUCTION.
3. ALL BIT CONC DRIVEWAYS SHALL BE SAWCUT FOR THE ENTIRE WIDTH OF THE DRIVEWAY FOR THE REMOVAL OF EXISTING PAVEMENT REQUIRED TO INSTALL THE SIDEWALKS AND SHALL BE INCIDENTAL TO SIDEWALK CONSTRUCTION. ADDITIONAL SAWCUTTING REQUIRED FOR FINAL BIT CONC DRIVEWAY
PERMANENT PAVEMENT REPLACEMENT/RESTORATION SHALL BE INCIDENTAL TO THE PERMANENT
PAVEMENT REPLACEMENT/RESTORATION. LIMIT OF BIT CONC PAVED DRIVEWAY RESTORATION SHALL BE A MINIMUM OF 2 FEET AND MAXIMUM OF 5 FEET INTO DRIVEWAY, UNLESS OTHERWISE DIRECTED BY ENGINEER. ACTUAL LIMIT OF PAVEMENT RESTORATION TO BE FIELD DETERMINED BY ENGINEER. FOR
BIDDING PURPOSES, FIVE (5) FEET SHALL BE CONSIDERED.
4. CONTRACTOR SHALL BE RESPONSIBLE TO COORDINATE WITH THE RESPECTIVE UTILITY COMPANIES IN CONNECTION WITH THE HORIZONTAL RELOCATION AND VERTICAL GRADE ADJUSTMENT OF ANY GAS AND/OR WATER SERVICE LATERAL SHUTOFF VALVES OR METER ACCESS CASTINGS WHICH MAY BE
REQUIRED.
5. THE LEGAL RIGHT-OF-WAY WIDTH ON S.R. 2011 (HUDSON ROAD) IS FIFTY (50) FEET.
6. CONTRACTOR SHALL PROTECT IRON PINS OR OTHER EXISTING PROPERTY CORNER SURVEY MARKERS
AND SHALL BE RESPONSIBLE TO HAVE IRON PINS RESET BY A PROFESSIONAL LAND SURVEYOR, LICENSED AND REGISTERED IN THE STATE OF PENNSYLVANIA, IF IT IS DISTURBED DURING
CONSTRUCTION.
7. THERE ARE NO SIGNS THAT WILL REQUIRE RELOCATION WITHIN THE LIMITS OF WORK.
8. POSTED SPEED LIMIT ON HUDSON ROAD (S.R. 2011) IS 25 M.P.H.
CONSTRUCTION DRAWINGS
2022-5500-001-400-002
MARCH 26, 2024
NRA
JNF
PL
AI
NS
T
OW
NS
HI
P, LU
ZE
RN
E
CO
UN
TY
, P
EN
NS
YL
VA
NI
A
HU
DS
ON
R
D
ST
RE
ET
SC
AP
E
PL
AI
NS
T
OW
NS
HI
P www.borton-lawson.com
DRAWING TITLE & PROJECT NAME
DRAWING NO.
SEALS
REVISIONS
DRAWN BY
CHECKED BY
DATE
PROJECT NO.
PROJECT STATUS
Th is dr aw ing re pr es en ts a d es ign in ten t a nd co nc ep t o nly
. T his do cu me nt an d a ll a ss oc iat ed do cu me nts ar e p re pa re d f or a sp ec ific si te an d e ve nt, an d i nc or po ra te ca lcu lat ion s a nd m ea su re me nts av ail ab le fro m tim e o f d ra ftin g.
Us e o f th is de sig n i s g ra nte d t o t he cl ien t fo r t he sp ec ifii ed an d n am ed ev en t o nly
2 3 4 5 6 7 8
B
C
D
E
F
A
DA
TE
NO
DE
SC
RI
PT
IO
N
Wilkes-Barre 613 Baltimore Dr. Suite 300
Wilkes-Barre, PA 18702 570-821-1999
C O
M
M O N W E A L T H
O F
REGISTERED
PROFESSIONAL
P E
N N S Y L V A N
I A
ENGINEER
PE081045
NICHOLAS RAY ARGOT
2492738.4564
SH
EE
T C
SH
EE
T C
ST
RE
ET
SC
AP
E
PL
AN
(E . M
ER
RI
TT
T
O
HE
NR
Y)
C201
CALL BEFORE YOU DIG!
PENNSYLVANIA LAW REQUIRES
3 WORKING DAYS NOTICE FOR
CONSTRUCTION PHASE AND 10 WORKING
DAYS IN DESIGN STAGE - STOP CALL
Pennsylvania One Call System, Inc.
1-800-242-1776
PA ONE CALL SERIAL NO. 20230111159
409504.4944
409302.77672492617.6165
409307.58592492628.6837
409310.86652492630.5718
409312.76632492631.2593
409462.59072492715.4079
409472.02982492713.6076
409483.20602492715.6510
2492746.0040 409518.0198
2492757.1224 409537.9483
2492774.0343 409568.4061
2492788.9274 409595.1607
2492796.0329 409607.4801
2492823.1999 409656.9236
2492819.6993 409668.1941
PREMOLDED 1/2" ASPHALT
EXPANSION JOINT FILLER 5" MIN. CLASS AA CONCRETE
6" PENNDOT NO. 2A CRUSHED
STONE COARSE AGGREGATE
COMPACTED SUBGRADE
VARIES
5.0'-5.4'±
*NO WORK SHALL BE
PERFORMED ON ANY WALL
ADJACENT TO
EXISTING/PROPOSED
SIDEWALK AS PART OF THIS
PROJECT.
SECTION B-B (WEST SIDE) TYP.
NOT TO SCALE
4" PER FOOT
CONCRETE
CURB
PERMANENT PAVEMENT
REPLACEMENT ALONG
NEWLY INSTALLED CURB (TYP)
SEE DETAIL ON DRAWING C900
HORIZONTAL CONTROL
COORDINATES (TYP)
PREMOLDED 1/2" ASPHALT
EXPANSION JOINT FILLER
CONTRACTOR SHALL ENSURE
GRASSED SURFACE ADJACENT
TO PROPOSED SIDEWALK IS
GRADED TO ALLOW 1" OF
SEPARATION BETWEEN TOP OF
GRASSED SURFACE AND TOP OF
SIDEWALK WHERE FEASIBLE. NO
GRADING SHALL TAKE PLACE
OUTSIDE OF PADOT
RIGHT-OF-WAY. WHERE
GRADING IS NOT FEASIBLE,
EXISTING ELEVATION OF
WESTERN SIDE OF SIDEWALK
SHALL BE MAINTAINED IN
PROPOSED CONDITIONS.
409487.26712492728.7171 PROPOSED CEM. CONC. SIDEWALK
PROPOSED BIT. CONC. DRIVEWAY RESTORATION
LEGEND
PROPOSED CONCRETE CURB
DRIVEWAY KEY NUMBER (REFER TO
DRIVEWAY KEY NUMBER TABULATION - THIS
SHEET)
XX' PROPOSED DRIVEWAY/DEPRESSED CURB WIDTH
CURB
4 HORIZONTAL CONTROL POINT
(SEE HORIZONTAL CONTROL POINT TABLE)
MATCHLINE
SHEET CXXX
SHEET CXXX
PROPOSED DETECTABLE WARNING SURFACE
PROPOSED UTILITY POLE LOCATION
PROPOSED CONC. DRIVEWAY RESTORATION
PROPOSED PAVEMENT RESTORATION
NOTE:
1. THE SIDEWALK SLOPE SHOULD NOT EXCEED 2% SLOPE IN ACCORDANCE WITH AASHTO GREENBOOK CH. 4.
2. REFER TO PENNDOT PUBLICATION 408 SECTIONS 630 AND 704 FOR ADDITIONAL INFORMATION ON CONCRETE
SIDEWALK AND CURB MATERIAL AND DESIGN.
NOTE:
1. THE SIDEWALK SLOPE SHOULD NOT EXCEED 2% SLOPE IN ACCORDANCE WITH AASHTO GREENBOOK CH. 4.
2. REFER TO PENNDOT PUBLICATION 408 SECTIONS 630 AND 704 FOR ADDITIONAL INFORMATION ON CONCRETE
SIDEWALK AND CURB MATERIAL AND DESIGN.
*UTILITY POLE RELOCATIONS AND REMOVALS
COVERED UNDER HOP NO. 04071082 AND 04071085.
70 HUDSON HOP APPLICATION NO. 319527
86 HUDSON HOP APPLICATION NO. 319550
143 HENRY HOP APPLICATION NO. 319447
SIGN TABLE
NAME NOMENCLATURE SIZE QUANTITY MAINTENANCE
RESPONSIBILITY
R1-1 "STOP" 30" X 30" 3 TOWNSHIP
R5-3-4 "NO TRUCKS OF BUSES" 30" X 24" 1 TOWNSHIP
R5-1 "DO NOT ENTER" 30" X 30" 2 TOWNSHIP
R7-302 NO PARKING 12" X 18" 2 TOWNSHIP
R7-301 NO PARKING ARROW PLAQUE 12" X 6" 4 TOWNSHIP
R6-1R ONE WAY RIGHT 36" X 12" 2 TOWNSHIP
R6-1L ONE WAY LEFT 36" X 12" 2 TOWNSHIP
AutoCAD SHX Text
BL BENCHMARK HYDRANT NW BOLT ELEVATION: 622.82'
AutoCAD SHX Text
BL BENCHMARK HYDRANT NW BOLT ELEVATION: 622.82'
AutoCAD SHX Text
ATTCH 52410 N40921 GJI1
AutoCAD SHX Text
ATTCH 52401 N40921 HOPKINS ST TAP 100K "SLOW CHURCH ZONE"
AutoCAD SHX Text
PPL 52401 N40928 GI55
AutoCAD SHX Text
GUY WIRES
AutoCAD SHX Text
PPL 52416 N40947 GI 59 " NO PARKING"
AutoCAD SHX Text
ATTCH 52420 N40955 GI 60632
AutoCAD SHX Text
PPL 52415 N40965
AutoCAD SHX Text 10"
AutoCAD SHX Text 12"
AutoCAD SHX Text
INLET
AutoCAD SHX Text
INLET
AutoCAD SHX Text
EAST MERRITT STREET
AutoCAD SHX Text
INLET
AutoCAD SHX Text 30"
AutoCAD SHX Text 30"
AutoCAD SHX Text
GV'S
AutoCAD SHX Text
RESIDENTIAL& COMMERCIAL STRUCTURE
AutoCAD SHX Text
GV
AutoCAD SHX Text
GV
AutoCAD SHX Text
WV
AutoCAD SHX Text
SAN MH
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
GV
AutoCAD SHX Text
WV'S
AutoCAD SHX Text
WM'S
AutoCAD SHX Text
INLET
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
GV
AutoCAD SHX Text
ATKINSON LN
AutoCAD SHX Text
HENRY ST
AutoCAD SHX Text
WV
AutoCAD SHX Text
GV
AutoCAD SHX Text
INLET
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
GV
AutoCAD SHX Text
INLET
AutoCAD SHX Text
DEAD POLE
AutoCAD SHX Text
PPL 52424 N40961
AutoCAD SHX Text
SR 2011 SEG 0070 OFF 719 ASPH. DRIVE
AutoCAD SHX Text
SAN MH RIM: 622.28' INV(NE): 612.18' INV(SW): 612.18' INV(NW): 612.28'
AutoCAD SHX Text
8" PVC
AutoCAD SHX Text
STORM MH
AutoCAD SHX Text
CONC. WALK
AutoCAD SHX Text
CONC. WALK
AutoCAD SHX Text
PPL 52405 N40927 G156
AutoCAD SHX Text
INLET
AutoCAD SHX Text
CONC. WALK
AutoCAD SHX Text
RESIDENTIAL STRUCTURE
AutoCAD SHX Text
STORM MH
AutoCAD SHX Text
STORM MH
AutoCAD SHX Text
SAN MH
AutoCAD SHX Text
INLET
AutoCAD SHX Text
PPL 52408 N40933
AutoCAD SHX Text
CONC. WALK
AutoCAD SHX Text
CONC. WALK
AutoCAD SHX Text
CONC. WALK
AutoCAD SHX Text
STORM MH
AutoCAD SHX Text
INLET
AutoCAD SHX Text
PPL ATTCH52412 N40940 1971
AutoCAD SHX Text
HEDGES
AutoCAD SHX Text
STORM MH
AutoCAD SHX Text
ASPHALT WALK
AutoCAD SHX Text
INLET
AutoCAD SHX Text
INLET
AutoCAD SHX Text
INLET
AutoCAD SHX Text
STORM MH
AutoCAD SHX Text
STORM MH
AutoCAD SHX Text #44
AutoCAD SHX Text #48/#50
AutoCAD SHX Text #60
AutoCAD SHX Text #64
AutoCAD SHX Text #68
AutoCAD SHX Text #72
AutoCAD SHX Text #52/#54
AutoCAD SHX Text #34/#36
AutoCAD SHX Text #30
AutoCAD SHX Text #26/#28
AutoCAD SHX Text
INLET
AutoCAD SHX Text
SR 2011 SEG 0070 OFF 659 GRAVEL PARKING LOT
AutoCAD SHX Text
HUDSON ROAD (SR 2011)
AutoCAD SHX Text
BANK STREET
AutoCAD SHX Text
STOP SIGN
AutoCAD SHX Text
NO PARKING SIGN
AutoCAD SHX Text
STOP SIGN
AutoCAD SHX Text
"NO PARKING HERE TO CORNER" SIGN
AutoCAD SHX Text
"NO PARKING HERE TO CORNER" SIGN
AutoCAD SHX Text
"NO PARKING" SIGN
AutoCAD SHX Text
"SPEED LIMIT 25" SIGN
AutoCAD SHX Text
"NO PARKING" SIGN
AutoCAD SHX Text
EXISTING DOUBLE YELLOW LINE (DY/4)
AutoCAD SHX Text
EXISTING PAVED ROADWAY SURFACE
AutoCAD SHX Text
*EXIST. WALL
AutoCAD SHX Text
EXISTING GRASSED SURFACE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
WEST DRIVEWAYS
AutoCAD SHX Text
LEGEND SYMBOL
AutoCAD SHX Text
HOUSE NUMBER
AutoCAD SHX Text
OWNER
AutoCAD SHX Text
DRIVEWAY PERMIT
AutoCAD SHX Text
SEGMENT
AutoCAD SHX Text
OFFSET
AutoCAD SHX Text
APPLICATION NUMBER
AutoCAD SHX Text
AutoCAD SHX Text #64
AutoCAD SHX Text
LAWRENCE & BARBARA GREBEY
AutoCAD SHX Text
MINIMUM USE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 319447
AutoCAD SHX Text
AutoCAD SHX Text #68
AutoCAD SHX Text
GERALD & THERESA HANCHULAK
AutoCAD SHX Text
LOW VOLUME
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 319527
AutoCAD SHX Text
DRIVEWAY KEY NUMBER TABULATION
AutoCAD SHX Text
AutoCAD SHX Text
EXISTING DRIVEWAY WIDTH
AutoCAD SHX Text #21
EXISTING POSTAL ADDRESS NUMBER
6.
3'
6.
1'
5.
6'
5.
4'
5.0
5.6
6.
8'
5.
5'
5.
2'
5.
0'
5.0
5.0
5.0
4.
9'
(TO BE RELOCATED)
6" REVEAL
END CONCRETE CURB
SR 2011 SEG 0070 OFF 359
6" REVEAL
6" REVEAL
MATCH EXISTING
SIDEWALK HEIGHT
BEGIN CONCRETE CURB
SR 2011 SEG 0070
OFF 511
REVEAL CURB
(MATCH EXISTING
CURB HEIGHT)
6" CURB
BEGIN CONCRETE CURB
SR 2011 SEG 0070 OFF 532
10.0' 8.0'
8.0'
(TO BE RELOCATED)
(TO BE RELOCATED)
W/6"
W/6"
W/6"
W/6"
PPL
52432
N40972
PROPOSED LOCATION
PPL
52446N40978
GI 64 26.5
PROPOSED LOCATION
PPL
52433
N40971
PROPOSED LOCATION
LIMIT OF WORK:
SR 2011 SEG 0070 OFF 0242
1.0
26 27
R10'
R10'
R10'
R10'
R10'
(TO BE REMOVED)
(TO BE REMOVED)
NO PARKING ZONE
(TO REMAIN)
INSTALL R7-301 SIGN BELOW EXISTING
"NO PARKING" SIGN ENSURING THAT ARROWS
ARE ORIENTED PARALLEL WITH HUDSON RD
ONE WAY (R6-1R)*
ONE WAY (R6-1L)*
DO NOT ENTER SIGN (R5-1)
*PLACE ONE WAY SIGNS ON
EITHER SIDE OF SIGN POST
INDICATING NO PERMITTED
ENTRANCE TO REAR
WILLIAM STREET
FROM HUDSON RD.
STOP SIGN
(R1-1)
0' 60'40'20'
PLAN
GRAPHIC SCALE IN FEET
SOUTH BOUND - WEST SIDE OF
HUDSON ROAD (S.R. 2011)
NORTH BOUND - EAST SIDE OF
HUDSON ROAD (S.R. 2011)
Point Table
Point #
Northing Easting
Point Table
Point # Northing Easting
HORIZONTAL CONTROL POINT TABLE
CONSTRUCTION DRAWINGS
2022-5500-001-400-002
MARCH 26, 2024
NRA
JNF
PL
AI
NS
T
OW
NS
HI
P, LU
ZE
RN
E
CO
UN
TY
, P
EN
NS
YL
VA
NI
A
HU
DS
ON
R
D
ST
RE
ET
SC
AP
E
PL
AI
NS
T
OW
NS
HI
P www.borton-lawson.com
DRAWING TITLE & PROJECT NAME
DRAWING NO.
SEALS
REVISIONS
DRAWN BY
CHECKED BY
DATE
PROJECT NO.
PROJECT STATUS
Th is dr aw ing re pr es en ts a d es ign in ten t a nd co nc ep t o nly
. T his do cu me nt an d a ll a ss oc iat ed do cu me nts ar e p re pa re d f or a sp ec ific si te an d e ve nt, an d i nc or po ra te ca lcu lat ion s a nd m ea su re me nts av ail ab le fro m tim e o f d ra ftin g.
Us e o f th is de sig n i s g ra nte d t o t he cl ien t fo r t he sp ec ifii ed an d n am ed ev en t o nly
2 3 4 5 6 7 8
B
C
D
E
F
A
DA
TE
NO
DE
SC
RI
PT
IO
N
Wilkes-Barre 613 Baltimore Dr. Suite 300
Wilkes-Barre, PA 18702 570-821-1999
C O
M
M O N W E A L T H
O F
REGISTERED
PROFESSIONAL
P E
N N S Y L V A N
I A
ENGINEER
PE081045
NICHOLAS RAY ARGOT
SH
EE
T C
SH
EE
T C
ST
RE
ET
SC
AP
E
PL
AN
(H
EN
RY
T
O
RE
AR
W
IL
LI
AM
C202
CALL BEFORE YOU DIG!
PENNSYLVANIA LAW REQUIRES
3 WORKING DAYS NOTICE FOR
CONSTRUCTION PHASE AND 10 WORKING
DAYS IN DESIGN STAGE - STOP CALL
Pennsylvania One Call System, Inc.
1-800-242-1776
PA ONE CALL SERIAL NO. 20230111159
2492996.2718 409772.3881
2492834.7297 409696.7451
2492847.9056 409701.2905
2492864.3052 409729.3486
2492893.5473 409762.0191
2492915.6057 409774.0996
2492925.1387 409777.8257
2493064.5751 409827.5844
2492879.5558 409704.3157
2492881.4167 409707.5727
2492898.5649 409731.0180
8 2492942.6469 409783.9113
9 2492957.7619 409788.7217
10 2492993.0642 409799.0744
2492904.4729 409736.4095
2492917.2020 409745.2196
2492944.9534 409758.5185
11 2493022.4702 409808.0317
2492996.2718 409772.388122
5" MIN. CLASS AA CONCRETE
6" PENNDOT NO. 2A CRUSHED
STONE COARSE AGGREGATE
COMPACTED SUBGRADE
VARIES
5.0'-7.0'±
SECTION A-A (WEST SIDE) TYP.
NOT TO SCALE
4" PER FOOT
CONCRETE
CURB
PERMANENT PAVEMENT
REPLACEMENT ALONG
NEWLY INSTALLED CURB (TYP)
SEE DETAIL ON DRAWING C900
HORIZONTAL CONTROL
COORDINATES (TYP)
PREMOLDED1/2" ASPHALT
EXPANSION JOINT FILLER
CONTRACTOR SHALL ENSURE
GRASSED SURFACE ADJACENT
TO PROPOSED SIDEWALK IS
GRADED TO ALLOW 1" OF
SEPARATION BETWEEN TOP OF
GRASSED SURFACE AND TOP OF
SIDEWALK WHERE FEASIBLE. NO
GRADING SHALL TAKE PLACE
OUTSIDE OF PADOT
RIGHT-OF-WAY. WHERE
GRADING IS NOT FEASIBLE,
EXISTING ELEVATION OF
WESTERN SIDE OF SIDEWALK
SHALL BE MAINTAINED IN
PROPOSED CONDITIONS.
VARIES
11.1' - 15.3'±
VARIES
12.2' - 14.5'±
SOUTH BOUND LANE NORTH BOUND LANE
12"SAWCUT AND SEAL WITH
CRAFCO SUPERFLEX
(TYP. BOTH SIDES)
12"
HUDSON ROAD (SR 2011)
TYPICAL ROADWAY SECTION
(LOOKING NORTH)
NOT TO SCALE
PROPOSED
CONCRETE
CURB
PROPOSED
CONCRETE
CURB
PERMANENT PAVEMENT
REPLACEMENT ALONG
NEWLY INSTALLED CURB (TYP)
SEE DETAIL ON DRAWING C900
** MAINTAIN EXISTING
CROSS-SLOPE
(TYP. BOTH SIDES)
5" MIN. CLASS AA CONCRETE
6" PENNDOT NO. 2A CRUSHED
STONE COARSE AGGREGATE
COMPACTED SUBGRADE
VARIES
5.0'-6.8'±
SECTION A-A (WEST SIDE) TYP.
NOT TO SCALE
4" PER FOOT
CONCRETE
CURB
PERMANENT PAVEMENT
REPLACEMENT ALONG
NEWLY INSTALLED CURB (TYP)
SEE DETAIL ON DRAWING C900
HORIZONTAL CONTROL
COORDINATES (TYP)
PREMOLDED1/2" ASPHALT
EXPANSION JOINT FILLER
CONTRACTOR SHALL ENSURE
GRASSED SURFACE ADJACENT
TO PROPOSED SIDEWALK IS
GRADED TO ALLOW 1" OF
SEPARATION BETWEEN TOP OF
GRASSED SURFACE AND TOP OF
SIDEWALK WHERE FEASIBLE. NO
GRADING SHALL TAKE PLACE
OUTSIDE OF PADOT
RIGHT-OF-WAY. WHERE
GRADING IS NOT FEASIBLE,
EXISTING ELEVATION OF
WESTERN SIDE OF SIDEWALK
SHALL BE MAINTAINED IN
PROPOSED CONDITIONS.
NOTES:
1. ALL REQUIRED TOPSOIL, SEED AND MULCH FILL RESTORATION BEHIND NEWLY INSTALLED SIDEWALKS
SHALL BE PLACED WITH A MAXIMUM SLOPE OF 3 HORIZONTAL TO 1 VERTICAL.
2. ANY EXISTING RAINWATER CONDUCTOR ROOF LEADER DOWNSPOUT EXTENSIONS WHICH ARE IN
DIRECT CONFLICT OR INTERFERE WITH THE CONSTRUCTION OF THE CURB AND SIDEWALK
IMPROVEMENTS SHALL BE REMOVED TO THE EXTENT THAT THEY WILL NO LONGER BE IN CONFLICT WITH THE PROPOSED CONSTRUCTION AND WILL DISCHARGE ON THE GROUND SURFACE ADJACENT TO THE STRUCTURE WHICH THEY ARE APPURTENANT TO. THIS WORK SHALL BE INCIDENTAL TO THE
PROPOSED CONSTRUCTION.
3. ALL BIT CONC DRIVEWAYS SHALL BE SAWCUT FOR THE ENTIRE WIDTH OF THE DRIVEWAY FOR THE REMOVAL OF EXISTING PAVEMENT REQUIRED TO INSTALL THE SIDEWALKS AND SHALL BE INCIDENTAL TO SIDEWALK CONSTRUCTION. ADDITIONAL SAWCUTTING REQUIRED FOR FINAL BIT CONC DRIVEWAY
PERMANENT PAVEMENT REPLACEMENT/RESTORATION SHALL BE INCIDENTAL TO THE PERMANENT
PAVEMENT REPLACEMENT/RESTORATION. LIMIT OF BIT CONC PAVED DRIVEWAY RESTORATION SHALL BE A MINIMUM OF 2 FEET AND MAXIMUM OF 5 FEET INTO DRIVEWAY, UNLESS OTHERWISE DIRECTED BY ENGINEER. ACTUAL LIMIT OF PAVEMENT RESTORATION TO BE FIELD DETERMINED BY ENGINEER. FOR
BIDDING PURPOSES, FIVE (5) FEET SHALL BE CONSIDERED.
4. CONTRACTOR SHALL BE RESPONSIBLE TO COORDINATE WITH THE RESPECTIVE UTILITY COMPANIES IN CONNECTION WITH THE HORIZONTAL RELOCATION AND VERTICAL GRADE ADJUSTMENT OF ANY GAS AND/OR WATER SERVICE LATERAL SHUTOFF VALVES OR METER ACCESS CASTINGS WHICH MAY BE
REQUIRED.
5. THE LEGAL RIGHT-OF-WAY WIDTH ON S.R. 2011 (HUDSON ROAD) IS FIFTY (50) FEET.
6. CONTRACTOR SHALL PROTECT IRON PINS OR OTHER EXISTING PROPERTY CORNER SURVEY MARKERS
AND SHALL BE RESPONSIBLE TO HAVE IRON PINS RESET BY A PROFESSIONAL LAND SURVEYOR, LICENSED AND REGISTERED IN THE STATE OF PENNSYLVANIA, IF IT IS DISTURBED DURING
CONSTRUCTION.
7. THERE ARE NO SIGNS THAT WILL REQUIRE RELOCATION WITHIN THE LIMITS OF WORK.
8. POSTED SPEED LIMIT ON HUDSON ROAD (S.R. 2011) IS 25 M.P.H.
PROPOSED CEM. CONC. SIDEWALK
PROPOSED BIT. CONC. DRIVEWAY RESTORATION
LEGEND
PROPOSED CONCRETE CURB
DRIVEWAY KEY NUMBER (REFER TO
DRIVEWAY KEY NUMBER TABULATION - THIS
SHEET)
XX' PROPOSED DRIVEWAY/DEPRESSED CURB WIDTH
CURB
4 HORIZONTAL CONTROL POINT
(SEE HORIZONTAL CONTROL POINT TABLE)
MATCHLINE
SHEET CXXX
SHEET CXXX
PROPOSED DETECTABLE WARNING SURFACE
PROPOSED UTILITY POLE LOCATION
PROPOSED CONC. DRIVEWAY RESTORATION
PROPOSED PAVEMENT RESTORATION
NOTE:
1. THE SIDEWALK SLOPE SHOULD NOT EXCEED 2% SLOPE IN ACCORDANCE WITH AASHTO GREENBOOK CH. 4.
2. REFER TO PENNDOT PUBLICATION 408 SECTIONS 630 AND 704 FOR ADDITIONAL INFORMATION ON CONCRETE
SIDEWALK AND CURB MATERIAL AND DESIGN.
*UTILITY POLE RELOCATIONS AND REMOVALS
COVERED UNDER HOP NO. 04071082 AND 04071085.
2493032.9559 409811.460512
2493039.6634 409821.2571
2493055.5698 409828.7322
2493002.5729 409771.939723
2493008.2879 409769.585824
2493043.8591 409775.336325
2493041.9435 409779.167026
2493045.9108 409787.151627
2493053.3751 409789.483428
SIGN TABLE
NAME NOMENCLATURE SIZE QUANTITY MAINTENANCE
RESPONSIBILITY
R1-1 "STOP" 30" X 30" 3 TOWNSHIP
R5-3-4 "NO TRUCKS OF BUSES" 30" X 24" 1 TOWNSHIP
R5-1 "DO NOT ENTER" 30" X 30" 2 TOWNSHIP
R7-302 NO PARKING 12" X 18" 2 TOWNSHIP
R7-301 NO PARKING ARROW PLAQUE 12" X 6" 4 TOWNSHIP
R6-1R ONE WAY RIGHT 36" X 12" 2 TOWNSHIP
R6-1L ONE WAY LEFT 36" X 12" 2 TOWNSHIP
AutoCAD SHX Text 30"
AutoCAD SHX Text 24"
AutoCAD SHX Text 24"
AutoCAD SHX Text
REAR WILLIAM STREET
AutoCAD SHX Text
CROW STREET
AutoCAD SHX Text
"STOP"
AutoCAD SHX Text
ATTCH 52449 N40969
AutoCAD SHX Text
GUY WIRE
AutoCAD SHX Text
PPL 52457 N40980
AutoCAD SHX Text
PPL 52427 N40965 GI 62
AutoCAD SHX Text
SAN MH
AutoCAD SHX Text
SAN MH
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
HYD
AutoCAD SHX Text
GV
AutoCAD SHX Text
GV
AutoCAD SHX Text
RESIDENTIAL STRUCTURE
AutoCAD SHX Text
RESIDENTIAL STRUCTURE
AutoCAD SHX Text
RESIDENTIAL STRUCTURE
AutoCAD SHX Text
PORCH
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
GV
AutoCAD SHX Text
GV
AutoCAD SHX Text
INLET
AutoCAD SHX Text
INLET
AutoCAD SHX Text
SAN MH
AutoCAD SHX Text
CONCRETE DRIVEWAY
AutoCAD SHX Text
INLET
AutoCAD SHX Text
INLET
AutoCAD SHX Text
INLET
AutoCAD SHX Text
INLET
AutoCAD SHX Text
CONC. DRIVE
AutoCAD SHX Text
CONC. PATIO
AutoCAD SHX Text
RESIDENTIAL STRUCTURE
AutoCAD SHX Text
CONC. WALK
AutoCAD SHX Text
SAN MH
AutoCAD SHX Text
SAN MH
AutoCAD SHX Text
STORM MH
AutoCAD SHX Text
ASPH. DRIVE
AutoCAD SHX Text
ASPH. DRIVE
AutoCAD SHX Text
CONC. WALK
AutoCAD SHX Text
SAN MH
AutoCAD SHX Text
ATTCH 52452 N40983 27 GI 65
AutoCAD SHX Text
PPL 52436 N40974
AutoCAD SHX Text
PPL 52432 N40972
AutoCAD SHX Text #78/#80
AutoCAD SHX Text #142
AutoCAD SHX Text #86/#88
AutoCAD SHX Text #90/#92
AutoCAD SHX Text #96
AutoCAD SHX Text #102
AutoCAD SHX Text #73
AutoCAD SHX Text #77
AutoCAD SHX Text #79
AutoCAD SHX Text #1
AutoCAD SHX Text #5
AutoCAD SHX Text #93
AutoCAD SHX Text #95
AutoCAD SHX Text
PENNSYLVANIA DEPARTMENT OF TRANSPORTATION RIGHT-OF-WAY LINE TYP.
AutoCAD SHX Text
SR 2011 SEG 0070 OFF 355
AutoCAD SHX Text
SR 2011 SEG 0070 OFF 553
AutoCAD SHX Text
PROPERTY LINE TYP.
AutoCAD SHX Text
PPL 52433 N40971
AutoCAD SHX Text
PPL 52446N40978 GI 64 26.5
AutoCAD SHX Text
PPL 52442 N440972
AutoCAD SHX Text
NO ID
AutoCAD SHX Text
NO ID
AutoCAD SHX Text
"NO PARKING ANYTIME" SIGN
AutoCAD SHX Text
EXISTING GRASSED SURFACE
AutoCAD SHX Text
EXISTING DOUBLE YELLOW LINE (DY/4)
AutoCAD SHX Text
EXISTING PAVED ROADWAY SURFACE
AutoCAD SHX Text
EXISTING GRASSED SURFACE
AutoCAD SHX Text
WEST DRIVEWAYS
AutoCAD SHX Text
LEGEND SYMBOL
AutoCAD SHX Text
HOUSE NUMBER
AutoCAD SHX Text
OWNER
AutoCAD SHX Text
DRIVEWAY PERMIT
AutoCAD SHX Text
SEGMENT
AutoCAD SHX Text
OFFSET
AutoCAD SHX Text
APPLICATION NUMBER
AutoCAD SHX Text
AutoCAD SHX Text #86/#88
AutoCAD SHX Text
MOJICA ROMANO
AutoCAD SHX Text
MINIMUM USE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 319550
AutoCAD SHX Text
DRIVEWAY KEY NUMBER TABULATION
AutoCAD SHX Text
AutoCAD SHX Text
EXISTING DRIVEWAY WIDTH
AutoCAD SHX Text #21
5.
0'
8.3' 5.9'
5.0'
2.0'
6" REVEAL CURB
CURB REACHES FULL 6" REVEAL
6" REVEAL CURB
CURB REACHES FULL 6" REVEAL
12'
CURB TAPER
13.9'
CURB TAPER
6" REVEAL CURB
CURB BREAK
W/6"
1'
4.0'
POLE TO BE REMOVED
POLE TO BE RELOCATED
POLE TO BE REMOVED
POLE TO BE RELOCATED
CURB REACHES FULL 6" REVEAL CURB BREAK
STOP SIGN
ONE-WAY SIGN
8.4'
4.0'
5.
0'
4.0'4.0'6.0'
4.0' 4.0'
W/6"
W/6" W/6"
STOP BAR
10.0'
7.
1'
6.3'
5.0'
4.0' 4.0'
4.0
4.0'
6.
0'
5.0' 4.3'
3.0'
4.6'
7.
1'
6.0'
6.0'
6.5'
4.0'5.2
W/6"
W/6"
W/6"
DY/4"
STOP BAR
STOP BAR
DY/4"
8.2'
5.0' 5.0'
7.7'
W/6"
W/6"
W/6"
0' 30'20'10'
PLAN
GRAPHIC SCALE IN FEET CONSTRUCTION DRAWINGS
2022-5500-001-400-002
MARCH 26, 2024
NRA
JNF
PL
AI
NS
T
OW
NS
HI
P, LU
ZE
RN
E
CO
UN
TY
, P
EN
NS
YL
VA
NI
A
HU
DS
ON
R
D
ST
RE
ET
SC
AP
E
PL
AI
NS
T
OW
NS
HI
P www.borton-lawson.com
DRAWING TITLE & PROJECT NAME
DRAWING NO.
SEALS
REVISIONS
DRAWN BY
CHECKED BY
DATE
PROJECT NO.
PROJECT STATUS
Th is dr aw ing re pr es en ts a d es ign in ten t a nd co nc ep t o nly
. T his do cu me nt an d a ll a ss oc iat ed do cu me nts ar e p re pa re d f or a sp ec ific si te an d e ve nt, an d i nc or po ra te ca lcu lat ion s a nd m ea su re me nts av ail ab le fro m tim e o f d ra ftin g.
Us e o f th is de sig n i s g ra nte d t o t he cl ien t fo r t he sp ec ifii ed an d n am ed ev en t o nly
2 3 4 5 6 7 8
B
C
D
E
F
A
DA
TE
NO
DE
SC
RI
PT
IO
N
Wilkes-Barre 613 Baltimore Dr. Suite 300
Wilkes-Barre, PA 18702 570-821-1999
C O
M
M O N W E A L T H
O F
REGISTERED
PROFESSIONAL
P E
N N S Y L V A N
I A
ENGINEER
PE081045
NICHOLAS RAY ARGOT
EN
LA
RG
ED
S
TR
EE
TS
CA
PE
IN
TE
RS
EC
TI
ON
P
LA
N
C203
CALL BEFORE YOU DIG!
PENNSYLVANIA LAW REQUIRES
3 WORKING DAYS NOTICE FOR
CONSTRUCTION PHASE AND 10 WORKING
DAYS IN DESIGN STAGE - STOP CALL
Pennsylvania One Call System, Inc.
1-800-242-1776
PA ONE CALL SERIAL NO. 20230111159
622.69622.60
TC: 621.50
BC: 621.50
TC: 621.43
BC: 621.43
621.38
TC:621.33
BC:621.33
TC: 621.59
BC: 621.09
621.68
621.48 621.44
TC: 621.30
BC: 620.80
620.98
621.20
TC:620.68
BC:620.68
621.54 621.60
TC: 621.82
BC: 621.32
TC:621.46
BC:621.27
TC: 621.18
BC: 621.18
621.51
PROPOSED CEM. CONC. SIDEWALK
PROPOSED BIT. CONC. DRIVEWAY RESTORATION
PROPOSED CONCRETE CURB
DRIVEWAY KEY NUMBER (REFER TO
DRIVEWAY KEY NUMBER TABULATION - THIS
SHEET)
XX' PROPOSED DRIVEWAY/DEPRESSED CURB WIDTH
CURB
4 HORIZONTAL CONTROL POINT
(SEE HORIZONTAL CONTROL POINT TABLE)
MATCHLINE
SHEET CXXX
SHEET CXXX
PROPOSED DETECTABLE WARNING SURFACE
PROPOSED UTILITY POLE LOCATION
PROPOSED CONC. DRIVEWAY RESTORATION
PROPOSED PAVEMENT RESTORATION
-8.1%
-1.5%
-3.0% -1 .5
-1.5%
-1 .5
-1.5%
-1 .5
TC: 621.52
BC: 621.33
621.90
-7.5% -1 .5
TC: 620.90
BC: 620.74
TC: 620.96
BC: 620.78
621.04
621.38
-7.0%
-1 .5
622.24
622.18
TC: 622.10
BC: 621.60
TC: 621.85
BC: 621.85
TC: 621.85
BC: 621.85
TC: 622.13
BC: 621.63
TC: 622.28
BC: 621.78 TC: 622.18
BC: 621.68
622.40
622.13
622.07
622.09 622.03 622.30
621.75
621.71
TC:621.88
BC:621.88
TC:621.84
BC:621.84
TC:621.53
BC:621.53
621.59
TC:621.50
BC:621.00
TC:622.47
BC:621.97
622.58
-1.5%
-1.5% -8.0%
-1.
5%
-1.5%
TC:621.13
BC:621.13
-1.5% -1.5%
AA BB
AA BB
TC:621.80
BC:621.80
-2.0%621.94
621.88
621.69
621.75 TC:621.69
BC:621.19
-6.4% -1.5%
-1.7%
-2.8%
-1.5% -1.0%
TC:621.00
BC:621.00
TC:621.83
BC:621.33
621.53 621.59
621.50
621.44
-1.5% -8.0%
-10%
-1.5%
-5.3% -4.2%-1.5%
FLARE SLOPE = -10%
FLARE SLOPE = -10%
-0.8% -2.7%
-1.8%
-0.8%
-4.5%
-2.8%
-2.2%
-1.4%
FLARE SLOPE = -9.7%
FLARE SLOPE = -8.4%
-4.2%
-2.5%
-3.3%
-0.8%
LEGEND
4" DOUBLE YELLOW LINESDY/4"
6" WHITE WHITE LINEW/6"
621.44
-1.5% -1.0%
-1.5% -1.0%
-1.0%
-2.5%
-3.
4%
-3.7%
-7 .3%
-4.8%-2.7%
-0.4%
CURB RAMP 1
CURB RAMP 2
CURB RAMP 3
CURB RAMP 4
CURB RAMP 5
CURB RAMP 6 CURB RAMP 7
CURB RAMP 8
AutoCAD SHX Text #60
AutoCAD SHX Text
"NO PARKING HERE TO CORNER"
AutoCAD SHX Text
"NO PARKING PED CROSSING"
AutoCAD SHX Text
PPL 52408 N40933
AutoCAD SHX Text
INLET
AutoCAD SHX Text
EAST MERRITT STREET
AutoCAD SHX Text
INLET
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
GV
AutoCAD SHX Text
"SPD LMT 25"
AutoCAD SHX Text
WV'S
AutoCAD SHX Text
WM'S
AutoCAD SHX Text
INLET
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
GV
AutoCAD SHX Text
ATKINSON LN
AutoCAD SHX Text
WV
AutoCAD SHX Text
GV
AutoCAD SHX Text
INLET
AutoCAD SHX Text
WV
AutoCAD SHX Text
STORM MH
AutoCAD SHX Text
CONC. WALK
AutoCAD SHX Text
STORM MH
AutoCAD SHX Text
STORM MH
AutoCAD SHX Text
SAN MH
AutoCAD SHX Text
INLET
AutoCAD SHX Text
CONC. WALK
AutoCAD SHX Text
CONC. WALK
AutoCAD SHX Text
CONC. WALK
AutoCAD SHX Text
INLET
AutoCAD SHX Text
HEDGES
AutoCAD SHX Text
STORM MH
AutoCAD SHX Text
WV
AutoCAD SHX Text
HUDSON RD (SR 2011)
AutoCAD SHX Text #44
AutoCAD SHX Text #48/#50
AutoCAD SHX Text #60
AutoCAD SHX Text #52/#54
AutoCAD SHX Text
PENNSYLVANIA DEPARTMENT OF TRANSPORTATION RIGHT-OF-WAY LINE TYP.
AutoCAD SHX Text
PROPERTY LINE TYP.
AutoCAD SHX Text
3" CURB REVEAL
AutoCAD SHX Text
NO CURB
AutoCAD SHX Text
NO CURB
AutoCAD SHX Text
"STOP"
AutoCAD SHX Text
EAST MERRITT STREET
AutoCAD SHX Text
GV
AutoCAD SHX Text
GV
AutoCAD SHX Text
WV
AutoCAD SHX Text
SAN MH
AutoCAD SHX Text
WV
AutoCAD SHX Text
8" PVC
AutoCAD SHX Text
CONC. WALK
AutoCAD SHX Text
INLET
AutoCAD SHX Text
CONC. WALK
AutoCAD SHX Text
RESIDENTIAL…