This is a site plan drawing showing security improvements needed for Building T6B, a daycare facility at VA Palo Alto. The drawing details several required security enhancements including: installation of motion intrusion alarm systems at the front entrance (room 1) and back entrance (room 10), raising existing brick fence and metal playground fencing to minimum 7-foot height, adding exit door alarms on egress doors, and installing new bollards every 5 feet on center. The plan also indicates locations for directional cameras and PTZ (pan-tilt-zoom) cameras that are part of a separate CCTV camera project.
The drawing, identified with Deficiency ID 28039, shows the daycare's location relative to other campus buildings including Building 710, Building 6, and Loop Road. It includes details of the outdoor play areas, main entrance, loading dock, walkways, parking areas and existing security features like masonry walls and steel perimeter fencing. The improvements appear focused on enhancing physical security and monitoring capabilities around the facility's perimeter and access points.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| EXHIBIT10_VA PAD ICRA.pdf | ||
| EXHIBIT11_As Builts.pdf | ||
| EXHIBIT7_PaloAlto_B7_Shade.pdf | ||
| Encl o Pricing Breakdown TO-RFP No 36C26125R0028.docx | DOCX document | |
| Encl p REQUEST FOR INFORMATION RFI FORM.docx | DOCX document | |
| EXHIBIT4B-VA HndBook-730-4.pdf | ||
| EXHIBIT8_PaloAlto_B100_F2-360.pdf | ||
| EXHIBIT6_PaloAlto_Daycare_Sandbox.pdf | ||
| EXHIBIT5_PaloAlto_Daycare_Fence.pdf | ||
| EXHIBIT2_PaloAlto_B5_Doors.pdf | ||
| EXHIBIT1_Specifications V3.pdf | ||
| S02 - 36C26125R0028_Final.pdf | ||
| Encl n - Experience Form.xlsx | XLSX spreadsheet | |
| Encl q Campus PAD_Map.pdf | ||
| EXHIBIT9_PaloAlto_B7_StormDrain.pdf | ||
| EXHIBIT3_PSRDM.pdf |
Show all 16
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
vhapalthongl Rectangle vhapalthongl Text Box Building T6B, Daycare vhapalthongl Text Box Deficiency ID: 28039 vhapalthongl Text Box Deficiency ID: 28039
VHAPALGargM Ellipse
VHAPALGargM Text Box #1 Motion Intrusion Alarm System
VHAPALGargM Ellipse
VHAPALGargM Text Box #1 Motion Intrusion Alarm System
VHAPALGargM Arrow vhapalthongl Callout Front Entrance (by room 1) vhapalthongl Callout Back Entrance (by room 10)
Rectangle vhapalthongl Text Box Building T6B, Daycare vhapalthongl Callout Front Entrance (by room 1) vhapalthongl Callout Back Entrance (by room 10)
VHAPALGargM Polygon
VHAPALGargM Polygon
VHAPALGargM Text Box Directional Camera Mounted to wall, part of CCTV Camera Project by others
VHAPALGargM Ellipse
VHAPALGargM Polygon
Attachment-SCI.pdf 1 of 2
Image vhapalfongjo Text Box Building 710 vhapalfongjo Text Box Loop Road vhapalfongjo Text Box
MB1
vhapalfongjo Text Box
MB2
vhapalfongjo Text Box
MB3
vhapalfongjo Text Box Building 6 vhapalfongjo Text Box Building T6B, Daycare vhapalthongl Rectangle vhapalthongl Cloud+ vhapalthongl Cloud+ Correct Security Deficiencies vhapalthongl Line vhapalthongl Line vhapalthongl Callout Perimeter Anti-Ram Barrier
PF
B6
T6-B
ME
Outdoor play area
Main entrance front gate loading dock masonry wall
6'-6" masonry wall
6' ht steel perimeter fence
MB-3
main walkway cell tower
Outdoor play area trellis delivery gate
6' ht steel fence
Whistlestop Childcare parking
Whistlestop Childcare mech equipmt yard
L O
O P
R
A D s id e w a lk
B116A
B116B daycare vest vhapalchanchr PolyLine vhapalchanchr Line vhapalchanchr Line vhapalchanchr Line vhapalchanchr Line vhapalchanchr Line
VHAPALGargM Dimension
VHAPALGargM Callout 6'-8"H
VHAPALGargM Image
VHAPALGargM Highlight
VHAPALGargM Highlight
VHAPALGargM Text Box Raise Existing Brick Fence to 7ft. min. height.
VHAPALGargM Rectangle
VHAPALGargM Text Box
DAY CARE SITE PLAN
VHAPALGargM PolyLine
VHAPALGargM Callout Raise (E) brick wall to 7 ft.
VHAPALGargM Arrow
VHAPALGargM Arrow
VHAPALGargM Callout Add Exit Door Alarm Outside Egress Door
VHAPALGargM Callout Add signage:
Image
B6
T6-B
ME
Outdoor play area
Main entrance front gate loading dock masonry wall
6'-6" masonry wall
6' ht steel perimeter fence
MB-3
main walkway cell tower
Outdoor play area trellis delivery gate
6' ht steel fence
Whistlestop Childcare parking
Whistlestop Childcare mech equipmt yard
L O e w a lk
B116A
B116B daycare vest vhapalchanchr PolyLine vhapalchanchr Line vhapalchanchr Line vhapalchanchr Line vhapalchanchr Line vhapalchanchr Line
VHAPALGargM Text Box
DAY CARE SITE PLAN
VHAPALGargM Polygon
VHAPALGargM Ellipse
VHAPALGargM Text Box Indicates PTZ Camera, part of CCTV Camera project by others.
VHAPALGargM Polygon
VHAPALGargM Ellipse
VHAPALGargM Polygon
VHAPALGargM Ellipse
VHAPALGargM Polygon
VHAPALGargM Ellipse
VHAPALGargM Polygon
VHAPALGargM Ellipse
VHAPALGargM Polygon
Ellipse
B6
T6-B
ME
Outdoor play area
Main entrance front gate loading dock masonry wall
6'-6" masonry wall
6' ht steel perimeter fence
MB-3
main walkway cell tower
Outdoor play area trellis delivery gate
6' ht steel fence
Whistlestop Childcare parking
Whistlestop Childcare mech equipmt yard
L O e w a lk
B116A
B116B daycare vest vhapalchanchr PolyLine vhapalchanchr Line vhapalchanchr Line vhapalchanchr Line vhapalchanchr Line vhapalchanchr Line
VHAPALGargM Ellipse
VHAPALGargM Callout New Bollard
VHAPALGargM Ellipse
VHAPALGargM Ellipse
VHAPALGargM Ellipse
VHAPALGargM Ellipse
VHAPALGargM Ellipse
VHAPALGargM Ellipse
VHAPALGargM Ellipse
VHAPALGargM Ellipse
VHAPALGargM Ellipse
VHAPALGargM Ellipse
VHAPALGargM Ellipse
VHAPALGargM Ellipse
VHAPALGargM Ellipse
VHAPALGargM Ellipse
VHAPALGargM Callout New Bollards at every 5 ft. OC. DESIGN TO BE DEVELOPED.
VHAPALGargM Dimension
VHAPALGargM Callout 6'-8"H
VHAPALGargM Image
VHAPALGargM Image
VHAPALGargM Image
VHAPALGargM Image
VHAPALGargM Image
VHAPALGargM PolyLine
VHAPALGargM PolyLine
VHAPALGargM PolyLine
VHAPALGargM Highlight
VHAPALGargM Highlight
VHAPALGargM Text Box Raise Existing Brick Fence to 7ft. min. height.
VHAPALGargM Callout Raise existing metal fence to 7' min. height, typical, around playground.
VHAPALGargM Rectangle
VHAPALGargM Text Box
DAY CARE SITE PLAN
VHAPALGargM PolyLine
VHAPALGargM PolyLine
VHAPALGargM Callout Raise (E) brick wall to 7 ft.
VHAPALGargM Arrow
VHAPALGargM Arrow
VHAPALGargM Callout Add Exit Door Alarm Outside Egress Door
VHAPALGargM Callout Add signage:
VHAPALGargM Image
VHAPALGargM Polygon
VHAPALGargM Ellipse
VHAPALGargM Text Box Indicates PTZ Camera, part of CCTV Camera project by others.
VHAPALGargM Polygon
VHAPALGargM Ellipse
VHAPALGargM Polygon
VHAPALGargM Ellipse
VHAPALGargM Polygon
VHAPALGargM Ellipse
VHAPALGargM Polygon
VHAPALGargM Ellipse
VHAPALGargM Polygon
Ellipse
File details come from the government source that posted it. Updated .