Exhibit G Scope of Work.pdf

PDF 102 KB Posted

Attached to
Lead Sample Analysis Services for the Department of State Health Services Laboratory located in Austin, TX.
Solicitation number
HHS0017054
Issued by
Travis County, Texas

About this file

This is a Scope of Work document for the Environmental Lead Investigation (ELI) Sample Analysis contract with the Texas Department of State Health Services (DSHS). The contract requires the awarded contractor to analyze lead samples collected from sites where children with elevated blood lead levels reside to determine the source of lead exposure. Sample types include paint chips, soil, dust samples, food/spices, and cosmetics. The contractor must maintain capability to perform multiple specialized laboratory testing methods, including Flame Atomic Absorption (SW-846 7000B) for paint chips, wipes, and soil; Graphite Furnace Atomic Absorption for drinking water, air, and wastewater samples; Toxicity Characteristic Leaching Procedure (TCLP), Total Threshold Limit Concentration (TTLC), and Soluble Threshold Limit Concentration (STLC) analyses; TSP Lead testing for suspended particulate matter; and Inductively Coupled Plasma Mass Spectrometry (ICP/ICP-MS) for trace element detection. The DSHS Risk Assessor will indicate sample type on submission forms, and the laboratory will determine appropriate testing methodology.

Test results must be delivered to the DSHS Blood Lead Surveillance Branch within 24 to 48 hours of finalization, as this critical turnaround time is essential for patients with lead poisoning to identify exposure sources and implement preventative measures. Results are to be transmitted by email or mail to the Environmental Lead Investigations unit. The contract operates under fiscal year 2027 parameters, with specific references to EPA publications SW-846, EPA Method 200.9, EPA Method 200.5, EPA Method 200.8/6020A, NIOSH Method 7105, and 40 CFR Part 50 standards guiding the analytical procedures and quality assurance requirements.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Exhibit G Scope of Work for Environmental Lead Investigation (ELI) Sample Analysis

ELI Sample Analyses SOW Page 1 of 2

FY'27

Analyze lead samples provided by the Environmental Lead Investigators to determine the source of lead exposure from samples collected at sites where children with elevated blood lead levels reside. Types of Materials for sampling include but are not limited to: paint chips, soil, dust samples, food/spices, and cosmetics

DSHS Blood Lead Investigators will send the materials to the awarded contractor to test for the presence of lead. The DSHS Risk Assessor will indicate on the submission form the type of sample that has been collected, and the laboratory will determine which testing method is appropriate.

The awarded contractor shall ensure the following required tests are available for performing the Lead Testing Service:

Perform tests needed for the Lead Laboratory Service to include:

1. Flame Atomic Absorption (FLAME AA) SW-846 test method 7000B Flame Atomic Absorption Spectrophotometry is to determine metals in solutions, applicable to ground water, aqueous samples, extracts, industrial wastes, soils, sludges, etc. Ref: EPA Publication SW-846 https://www.epa.gov/hw-sw846

• Paint Chips (SW-846-7000B)

• Wipes (SW-846-7000B)

• Soil (SW-846-7000B)

2. Graphite Furnace Atomic Absorption: Graphite furnace atomic absorption spectroscopy is a type spectroscopy that uses a graphite-coated furnace to vaporize the sample. It’s a technique in which a small sample is placed inside a graphite tube that is then resistively heated to accomplish sample desolvation (for liquid samples), ashing, or charring (to decompose the sample and volatilize some of the matrix).

• Drinking Water (EPA 200.9) is a test method that analyzes Trace Elements by stabilized Temperature Graphite Furnace Atomic Absorption (GFAA). This analyzes elements in ground water, surface water, drinking water, storm runoff, industrial and domestic wastewater, as well as in sediments, soils, and sludge.

• Air (National Institute for Occupational Safety and Health manual found on the CDC website https://www.epa.gov/hw-sw846

Exhibit G Scope of Work for Environmental Lead Investigation (ELI) Sample Analysis

ELI Sample Analyses SOW Page 2 of 2

FY'27

https://www.cdc.gov/niosh/docs/2003-154/method-8000.html

NIOSH 7105)

• Wastewater (SW-846-Test Method 7010/7421) is a test method that applies to metals in environmental samples including ground water, domestic and industrial wastes, extracts, soils, sludges, sediments, and similar waste.

3. Test method SW-846 provide information on the Toxicity

Characteristic Leaching Procedure (TCLP) Flame AA which is to determine the mobility of both organic and inorganic analytes present in liquid, solid and multiphasic wastes.

4. The method will provide information on Total Threshold Limit Concentration (TTLC) Flame AA

5. The method will provide Soluble Threshold Limit Concentration (STLC) Flame AA

6. The method will provide TSP Lead (Trisodium Phosphate)

• Lead in Suspended Particulate Matter (40 CFR Part 50:by ICP-

MS) The United States Environmental Protection Agency (EPA) has recommended the use of trisodium phosphate (TSP) detergent to clean lead-contaminated dust from surfaces, both after residential lead hazard control work to achieve post-abatement clearance standards and in general.

7. Inductively Coupled Plasma Mass Spectrometry ICP/ICP-MS is an analytical technique that is used to measure elements at trace levels in biological fluids.

• Lead in Drinking Water. EPA 200.5 method determines the trace of elements in drinking water by Axially viewed inductively coupled plasma-Atomic Emission Spectrometry)

• Lead by ICP-MS via 200.8/6020A method determines the trace element in waters and waste by inductively coupled plasma -Mass Spectrometry

Provide sample analyses to the DSHS Blood Lead Surveillance Branch:

Attention Environmental Lead Investigations.

Awarded contractor must send test results by email or mail to the Blood Lead Surveillance Branch within 24 to 48 hours of finalized results. The turn-around time is critical for patients with lead poisoning, to determine the cause of the lead exposures for preventative measures.

https://www.cdc.gov/niosh/docs/2003-154/method-8000.html%20NIOSH%207105 https://www.cdc.gov/niosh/docs/2003-154/method-8000.html%20NIOSH%207105