This vendor shop drawing document provides security gate construction plans for the Ocean Center located at 101 N. Atlantic Avenue in Daytona Beach, Florida, prepared for Volusia County. The drawings detail the installation specifications for FLASH security gate systems at both the east and west side entry points of the facility. The project scope includes two FLASH Mini Kiosks, TagMaster AVI readers, NEMA enclosures, and vehicle loop detectors for access control integration. The construction plans specify equipment placement, conduit routing, electrical requirements, and mounting details across multiple sheets, with dimensional diagrams and conduit clearance patterns for both full and mini kiosk configurations. The drawings were initially designed on June 10, 2026, and finalized for distribution on June 17, 2026, with no revisions noted in the document.

The technical specifications establish that each kiosk and barrier gate requires dedicated 120-volt, 20-ampere power circuits and individual CAT6 data lines for internet connectivity with minimum bandwidth of 10 megabits per second upload and download speeds. The site requirements include a Master Distribution Frame communication room housing a Merchant Gateway, 4G LTE modem for cloud backup, and an eight-port ProSAFE Gigabit Smart Managed Switch for network routing. All work must comply with current local electrical codes, the National Electrical Code (NFPA 70), and Authority Having Jurisdiction requirements, with local codes taking precedence over shop drawings where conflicts exist. The General Contractor and Electrical Contractor bear responsibility for verifying field conditions prior to installation, and conduit runs between same-island equipment must route internally through the island structure in clean, continuous runs meeting NEC Chapter 9 Table 1 specifications.

View the file

Other files

File Type Posted
Ocean_Center_Security_Fencing_and_Loading_Dock_Gates_(Addendum_#5_Revision).pdf PDF
Exhibit_I-OC_Security_Fencing_Project_Manual_08.27.26.pdf PDF
Ocean_Center_Security_Fencing_and_Loading_Dock_Gates_(Addendum_#1_Revision).pdf PDF
COV_Div_27_Technology_Systems_Design_and_Installation_Guidelines_073025_.pdf PDF
Ocean_Center_Security_Fencing_and_Loading_Dock_Gates.pdf PDF
Exhibit_H-_Div_27_Technology_Systems_Design_and_Installation_Guidelines.pdf PDF
Exhibit_H-_Div_27_Technology_Systems_Design_and_Installation_Guidelines.pdf PDF
Exhibit_H-_Div_27_Technology_Systems_Design_and_Installation_Guidelines.pdf PDF
Exhibit_F-_Sales_Tax_Exemption_Procedures_26-B-114KO.pdf PDF
Exhibit_F-_Sales_Tax_Exemption_Procedures_26-B-114KO.pdf PDF
Exhibit_F-_Sales_Tax_Exemption_Procedures_26-B-114KO.pdf PDF
Exhibit_B-PRIME-SUB_FORM_26-B-114KO.xls XLS spreadsheet
Exhibit_B-PRIME-SUB_FORM_26-B-114KO.xls XLS spreadsheet
Exhibit_B-PRIME-SUB_FORM_26-B-114KO.xls XLS spreadsheet
Exhibit_G-_Staging_Area_26-B-114KO_.png PNG image
Exhibit_G-_Staging_Area_26-B-114KO_.png PNG image
Exhibit_G-_Staging_Area_26-B-114KO_.png PNG image
Exhibit_C_-_Draft_Construction_Contract_26-B-114KO.pdf PDF
Exhibit_C_-_Draft_Construction_Contract_26-B-114KO.pdf PDF
Exhibit_C_-_Draft_Construction_Contract_26-B-114KO.pdf PDF
Exhibit_A-_Insurance_Requirements_26-B-114KO_Ocean_Center_Fencing_and_Loading_Dock.pdf PDF
Exhibit_A-_Insurance_Requirements_26-B-114KO_Ocean_Center_Fencing_and_Loading_Dock.pdf PDF
Exhibit_A-_Insurance_Requirements_26-B-114KO_Ocean_Center_Fencing_and_Loading_Dock.pdf PDF
Exhibit_E-_Security_Gate_Construction_Plans_26-B-114KO.pdf PDF
Exhibit_E-_Security_Gate_Construction_Plans_26-B-114KO.pdf PDF
Exhibit_D-_Construction_Plans_26-B-114KO.pdf PDF
Exhibit_D-_Construction_Plans_26-B-114KO.pdf PDF
Exhibit_D-_Construction_Plans_26-B-114KO.pdf PDF
Debary_Hall_Caretaker_&_Icehouse_Price_Sheet_6-9-25_Edit_-_Copy.xlsx XLSX spreadsheet
PRIME-SUB_FORM_for_Contractors_rev._01.15.2025_(lock_before_publishing).xls XLS spreadsheet
FLASH_OCEAN_CENTER_SECURITY_GATES_061826_R0.pdf PDF
PC4110_OC_Security_Fencing_CD_06.18.26.pdf PDF
Staging_Area_Outlined_In_Orange_.png PNG image
DBOC_Special_Conditions_for_Loading_Dock_Gates_(1).docx DOCX document
PC4110_OC_Security_Fencing_CD_06.18.26.pdf PDF
PC4110_OC_Security_Fencing_Project_Manual_03.20.26.pdf PDF
PRIME-SUB_FORM_for_Contractors_rev._01.15.2025_(lock_before_publishing).xls XLS spreadsheet
Debary_Hall_Caretaker_&_Icehouse_Price_Sheet_6-9-25_Edit_-_Copy.xlsx XLSX spreadsheet
Staging_Area_Outlined_In_Orange_.png PNG image
DBOC_Special_Conditions_for_Loading_Dock_Gates_(1).docx DOCX document
FLASH_OCEAN_CENTER_SECURITY_GATES_061826_R0.pdf PDF
PC4110_OC_Security_Fencing_Project_Manual_03.20.26.pdf PDF
Show all 42

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

OCEAN CENTER SECURITY GATES

101 N. ATLANTIC AVE

DAYTONA BEACH, FL 32118

FLASH PROJECT # 006Pg0000109PoHIAU

TABLE OF CONTENTS

SHEET NUMBER TITLE

1 COVER PAGE

2 LEGEND

LEVEL 1

3 LEVEL 1 OVERVIEW

4 EAST SIDE ENTRY

5 WEST SIDE ENTRY

TABLE OF REVISIONS

REV # REV DATE DRAWN BY CHECKED BY REVISION DESCRIPTION

0 6/10/2026 RCS CMD INITIAL DESIGN

B

EE

C A

VE

S

R O

A D

, B U

IL

D

IN

G

, S

U

IT

E

0, A

U

ST

IN

, T

X

REV # REV DATE REV INITIALS

SEAL + SIGNATURE

DESIGN TEAM

SHEET TITLE

SHEET NUMBER

CLIENT + PROJECT INFORMATION

FLASH PROJECT NAME

FLASH PROJECT NUMBER

101 N. ATLANTIC AVE

DAYTONA BEACH, FL 32118

NAME DATE

006Pg0000109PoHIAU

OCEAN CENTER SECURITY GATES

6/10/2026

RCS

DATE

June 17, 2026

COVER PAGE

VENDOR SHOP DRAWINGS

(FOR INFORMATIONAL

PURPOSES ONLY)

OCEAN CENTER

CONVENTION CENTER

FLASH EQUIPMENT LEGEND

17" DIA

BASE PLATE

LPR "L" POLE

17" DIA

BASE PLATE

LPR "T" POLE

GENERAL LOCATION OF

FLASH NETWORK DEVICES

NETWORK KIT

FLASH

NETWORK KIT

MAX 1.2A 12-24V DC

READER 12"x12"x1"

WIEGAND OUTPUT

HID LONG RANGE

READER

MAX 2.5A, 120V AC

10'-20' BOOM

STRAIGHT OR

ARTICULATING

BARRIER GATE

IF INCLUDED IN SCOPE:

41/2" Ø STEEL PIPE

8"x8"x1/4" MOUNTING PLATE

SAFETY YELLOW

OTHERWISE LOCATION IS A

RECOMMENDATION BUT SUPPLIED BY OTHERS

BOLLARD

3'x6' OR 2'x7'

VEHICLE

DETECTION LOOP

12-24V DC

OPTEX OAM

EXPLORER

SENSOR

2"x2" SQ TUBE 4"x4"x1/8" PLATE

SAFETY YELLOW

OPTEX POST

ENTRY & EXIT

LOW VOLTAGE

AVI READER

PROVIDED & CONTROLLED

BY OTHERS

OVERHEAD DOOR

CONTROLLER

ROLL DOOR

CONTROLLER

(BY OTHERS)

SIZE & POWER

REQUIREMENTS VARIES

PER SIGN

SIGNAGE

PED WARNING

OPEN / FULL

X

12V DC, POE

DEDICATED CAT6

CCTV SECURITY

CAMERA

MAX 120V

DATA FROM KISOK

VIA USB CONNECTION

BANK NOTE

RECYCLER (BNR)

1" CONDUIT SIZE CAT6 INTERNAL

WIRE - QTY(2)

CONDUIT CALL OUT EXAMPLE:

18/10 STRANDED & SHIELDED

INTERNAL WIRE - QTY(1)

1" B2,C1

FLASH CONDUIT LEGEND

INTERNAL WIRING

DESIGNATION DESCRIPTION QTY

A 20A 120V CIRCUIT #

B CAT6 ETHERNET #

C 18/10 STRANDED & SHEILDED #

D VEHICLE DETECTION LOOP LEAD IN #

E OEM PROVIDED WIRING #

F 16/2 STRANDED & SHIELDED 24V CIRCUIT #

G LV OR DRY CIRCUIT PROVIDED BY OTHERS #

FULL KIOSK CONDUIT

CLEARANCE AND HOLE PATTERN2-4

SCALE: NTS

16"

11"

2"121

2"

TOP VIEW OF FULL KIOSK

2-5

SCALE: NTS

EQUIPMENT ANCHORING DETAIL

6" CONC. CURB

ANCHOR

BOLT(4 TYP)

FRONT VIEW OF FULL & MINI KIOSK

CONDUIT

PENETRATION

BARRIER GATE CONDUIT CLEARANCE

AND HOLE PATTERN2-2

SCALE: NTS

10"

9" 131 2"

2"

TOP VIEW OF BARRIER GATE

TRAFFIC ISLAND

6" CURB

10" 10"

CONDUIT SWEEP FOR VEHICLE

DETECTION LOOPS - FULL KIOSK2-6

SCALE: NTS

FULL KIOSK

BARRIER GATE

3"

2-1

SCALE: NTS

2"

2"71

2"

2"

TOP VIEW OF MINI KIOSK

MINI KIOSK CONDUIT CLEARANCE

AND HOLE PATTERN

TRAFFIC ISLAND

6" CURB

10"

MINI KIOSK

CONDUIT SWEEP FOR VEHICLE

DETECTION LOOPS - MINI KIOSK2-3

SCALE: NTS

7"

BARRIER GATE

3"

CONDUIT SWEEP REQUIRED FOR VEHICLE DETECTION LOOPS

· 3

4" PVC FROM BASE OF CURB TO CENTER OF CONDUIT CLUSTER.

· PREFORMED LOOPS WET CUT 34" - 1" DEEP IN SLAB.

· EACH GATE & KIOSK GETS TYPICAL 3'X'6 LOOP WITH 50' LEAD (2 PER DRIVE LANE)

NOTE: ALL CONDUIT STUB UPS TO BE CENTERED UNDER EACH PIECE OF EQUIPMENT

NOTE: NOT ALL EQUIPMENT SHOWN HERE USED. SEE OVERVIEW PAGES FOR BILL OF MATERIALS.

DEDICATED CAT6

VISION

LPR CAMERA

12-24V DC

OPTEX OVS-02-GT

SENSOR

8'x2"x2" SQ TUBE 8"x8"x1/4" BASE PLATE

UNIVERSAL

MOUNTING POLE

(3) QTY CAT6, POE

MEGASTIX IP

CAMERAS

(1) QTY CAT6, POE

12.1W MAX

AXIS P3265 WALL

MOUNTED

FLEXIBLE DELINEATOR

WHITE, 36" OR 48" TALL

DELINEATOR

USED FOR MOUNTING OF

3RD PARTY READERS

GOOSENECK

PEDSTAL

3'x2"x2" SQ TUBE 8"x8"x1/4" BASE PLATE

FRONT CAPTURE

LPR POLE

6" SQUARE BASEPLATE

HEIGHT VARIES BASED ON

QUOTED POLE

SIGNALTECH POST

WITH SIGN

BRACKET

ENTRY & EXIT

(2) DEDICATED CAT6

HTS LPR CAMERAS

ENTRY & EXIT

MAX 8A, 120V AC

DEDICATED CAT6

FLASH KIOSK

ENTRY & EXIT

MAX 8A, 120V AC

DEDICATED CAT6

FLASH MINI KIOSK

MAX 14A, 120V AC

DEDICATED CAT6

FLASH WALL

MOUNT KIOSK

MAX 4.2A 24V DC

1 CAT6

PEDESTRIAN

ACCESS DOOR

READER

NEMA 3R

120V MAX

DEDICATED CAT6

ACCESS CONTROL

KIT

1. FOUNDATIONS & MOUNTING

1.1. CONCRETE ISLANDS SUPPORTING IN-LANE KIOSKS AND GATES SHALL BE CONSTRUCTED TO A FINISHED HEIGHT OF

6 INCHES ABOVE ADJACENT ASPHALT OR CONCRETE SURFACES. PAD SHALL BE LEVEL, CURED PRIOR TO

EQUIPMENT INSTALLATION & SUFFICIENTLY REINFORCED TO SUPPORT EQUIPMENT LOADS.

1.2. FINAL ELEVATIONS SHALL ENSURE ALL EQUIPMENT IS ACCESSIBLE AND COMPLIANT WITH ADA AND

MANUFACTURER REQUIREMENTS

2. CABLING & DISTANCES

2.1. ALTERNATE SOLUTIONS (E.G. FIBER CONVERSION,GAMECHANGER CALBE, EXTENDERS, ETC.) ARE REQUIRED FOR

CAT 6 CABLE RUNS EXCEEDING 328 FEET (100 METERS)

3. CONDUIT ROUTING

3.1. CONDUIT RUNS BETWEEN EQUIPMENT ON THE SAME ISLAND SHALL BE ROUTED INTERNALLY THROUGH THE ISLAND

3.2. CONDUIT SHALL BE INSTALLED IN A CLEAN, CONTINUOUS RUN WITH NO UNNECESSARY BENDS

3.3. MINIMUM CONDUIT SIZE SHALL MEET CABLE FILL REQUIREMENT PER NEC CHAPTER 9, TABLE 1

4. CODE COMPLIANCE

4.1. ALL WORK SHALL COMPLY WITH CURRENT LOCAL ELECTRICAL CODES, NEC (NFPA 70), AND ANY AHJ (AUTHORITY

HAVING JURISDICTION) REQUIREMENTS.

4.2. LOCAL CODES AND REGULATIONS TAKE PRECEDENCE OVER PROVIDED SHOP DRAWINGS WHERE DISCREPANCIES

EXIST

5. COORDINATION & RESPONSIBILITIES

5.1. THE GENERAL CONTRACTOR (GC) AND ELECTRICAL CONTRACTOR (EC) ARE RESPONSIBLE FOR VERIFYING ALL

FIELD CONDITIONS PRIOR TO INSTALLATION

6. POWER REQUIREMENTS

6.1. POWER CIRCUITS SHALL BE DEDICATED AND PROTECTED PER FLASH SPECIFICATIONS

7. SAFETY & ACCESS

7.1. MAINTAIN CLEARANCES PER EQUIPMENT MANUFACTURER GUIDELINES TO ALLOW FOR SERVICE AND

MAINTENANCE

7.2. ENSURE NO OBSTRUCTIONS (BOLLARDS, CURBS, WALLS, SIGANAGE, ETC.) INTERFERE WITH EQUIPMENT

OPERATION

EQUIPMENT / SITE REQUIREMENTS - GENERAL NOTES

PM MODULAR

POLE

7" X 7" SQUARE BASE PLATE

3" X 3" SQUARE POLE

B

EE

C A

VE

S

R O

A D

, B U

IL

D

IN

G

, S

U

IT

E

0, A

U

ST

IN

, T

X

REV # REV DATE REV INITIALS

SEAL + SIGNATURE

DESIGN TEAM

SHEET TITLE

SHEET NUMBER

CLIENT + PROJECT INFORMATION

FLASH PROJECT NAME

FLASH PROJECT NUMBER

101 N. ATLANTIC AVE

DAYTONA BEACH, FL 32118

NAME DATE

006Pg0000109PoHIAU

OCEAN CENTER SECURITY GATES

6/10/2026

RCS

DATE

June 17, 2026

VENDOR SHOP DRAWINGS

(FOR INFORMATIONAL

PURPOSES ONLY)

OCEAN CENTER

LEGEND

RO

LL

D

OO

R

CO

NT

RO

LL

ER

(B

Y

OT

HE

RS

ROLL DOOR

CONTROLLER

(BY OTHERS)

EAST SIDE ENTRY

OCEAN CENTER SECURITY GATES

EQUIPMENT SHOWN:

· FLASH MINI KIOSK (2)

· TAGMASTER AVI READERS (2)

· NEMA ENCLOSURE (2)

· ALL VEHICLE LOOP DETECTORS INCLUDED

SCALE: 1" = 40'

WEST SIDE ENTRY

TABLE OF CONTENTS

SHEET NUMBER TITLE

LEVEL 1

3 LEVEL 1 OVERVIEW

4 EAST SIDE ENTRY

5 WEST SIDE ENTRY

SITE REQUIREMENTS

Every kiosk and barrier gate will need access to a 120V 20A power circuit and access to an individual data line for each internal component that requires Internet access (minimum of 10 up 10 down MBPs). CAT6 is preferred.

● Sample conduit runs for parking islands (attached)

● Equipment dimensions (attached) *The entry and exit kiosk all have the same dimension.

MDF “COMMUNICATION ROOM” -

● Merchant Gateway -Gateway communication from the equipment to the Internet. This unit is included in the base bid as part of the “Network Kit”

● 4G LTE Modem – Provides temporary back up to the cloud if location loses primary Internet. This unit is included in base bid as part of the “Network Kit”

● ProSAFE® 8-port Gigabit Smart Managed Switch - Router for parking equipment. This unit is included in base bid as part of the “Network Kit” 25

B

EE

C

A

VE

S R

O A

D , B

U

IL

D

IN

G

, S U

IT

E

0, A U

ST

IN

, T X

REV # REV DATE REV INITIALS

SEAL + SIGNATURE

DESIGN TEAM

SHEET TITLE

SHEET NUMBER

CLIENT + PROJECT INFORMATION

FLASH PROJECT NAME

FLASH PROJECT NUMBER

101 N. ATLANTIC AVE

DAYTONA BEACH, FL 32118

NAME DATE

006Pg0000109PoHIAU

OCEAN CENTER SECURITY GATES

6/10/2026

RCS

DATE

June 17, 2026

N

VENDOR SHOP DRAWINGS

(FOR INFORMATIONAL

PURPOSES ONLY)

OCEAN CENTER

LEVEL 1 OVERVIEW

R O

LL

D

O O

R C

O N

TR

O

LL

ER

(B Y

O

TH

ER

S)

10'-10"

2'

6"

TYP

1'-6"

1'-6"

10"

1'-6"

1'

5'-2"

13'-4"

7'-6"

FROM CENTER OF

MOUNTING POLE

TO GATE

USING THE SAME ISLAND

LOCATION INDICATED

IN THE PLANS

10'

FROM LOOP

TO GATE

A NEMA BOX WITH A

LOOP DETECTOR KIT

IS REQUIRED. FINAL

LOCATION ON SITE

BY OTHERS7"

R O

LL

D

O O

R C

O N

TR

O

LL

ER

(B Y

O

TH

ER

S)

1" A1

1" B3

1" D1

1" B1,C1,G1

1" G1 1" B1,C1

1" B2

QTY (1) 20A 120V CIRCUITS REQUIRED

FROM CLOSEST SOURCE

QTY (3) CAT6 REQUIRED FROM

NETWORK ROOM

1" A1

N

SCALE: 1" = 2'

DIMENSIONAL DETAILS

SCALE: 1" = 2'

CONDUIT DETAILS

B

EE

C A

VE

S

R O

A D

, B U

IL

D

IN

G

, S

U

IT

E

0, A

U

ST

IN

, T

X

REV # REV DATE REV INITIALS

SEAL + SIGNATURE

DESIGN TEAM

SHEET TITLE

SHEET NUMBER

CLIENT + PROJECT INFORMATION

FLASH PROJECT NAME

FLASH PROJECT NUMBER

101 N. ATLANTIC AVE

DAYTONA BEACH, FL 32118

NAME DATE

006Pg0000109PoHIAU

OCEAN CENTER SECURITY GATES

6/10/2026

RCS

DATE

June 17, 2026

N

VENDOR SHOP DRAWINGS

(FOR INFORMATIONAL

PURPOSES ONLY)

OCEAN CENTER

EAST SIDE ENTRY

10'-10"

2'

6"

TYP

7" 1'-6"

1'-6"

10"

1'-6"

1'

5'-2"

5'-2"

FROM CENTER OF

MOUNTING POLE

TO GATE

ROLL DOOR

CONTROLLER

(BY OTHERS)

USING THE SAME ISLAND

LOCATION INDICATED

IN THE PLANS

A NEMA BOX WITH A LOOP

DETECTOR KIT IS

REQUIRED. FINAL

LOCATION ON SITE

BY OTHERS

7'-8"

FROM LOOP

TO GATE

1" D1

1" B1,C1,G1

1" B1,C1

ROLL DOOR

CONTROLLER

(BY OTHERS)

1" G1

1" A1

1" B3

1" B2

QTY (1) 20A 120V CIRCUITS REQUIRED

FROM CLOSEST SOURCE

QTY (3) CAT6 REQUIRED FROM

NETWORK ROOM

1" A1

N

SCALE: 1" = 2'

DIMENSIONAL DETAILS

SCALE: 1" = 2'

CONDUIT DETAILS

B

EE

C A

VE

S

R O

A D

, B U

IL

D

IN

G

, S

U

IT

E

0, A

U

ST

IN

, T

X

REV # REV DATE REV INITIALS

SEAL + SIGNATURE

DESIGN TEAM

SHEET TITLE

SHEET NUMBER

CLIENT + PROJECT INFORMATION

FLASH PROJECT NAME

FLASH PROJECT NUMBER

101 N. ATLANTIC AVE

DAYTONA BEACH, FL 32118

NAME DATE

006Pg0000109PoHIAU

OCEAN CENTER SECURITY GATES

6/10/2026

RCS

DATE

June 17, 2026

N

VENDOR SHOP DRAWINGS

(FOR INFORMATIONAL

PURPOSES ONLY)

OCEAN CENTER

WEST SIDE ENTRY

Sheets and Views
FLASH_OCEAN CENTER SECURITY GATES_061026_R0-1
FLASH_OCEAN CENTER SECURITY GATES_061026_R0-2
FLASH_OCEAN CENTER SECURITY GATES_061026_R0-3
FLASH_OCEAN CENTER SECURITY GATES_061026_R0-4
new

FLASH_OCEAN CENTER SECURITY GATES_061026_R0-5

File details come from the government source that posted it. Updated .