Exhibit_E-_Security_Gate_Construction_Plans_26-B-114KO.pdf
PDF 2 MB Posted
- Solicitation number
- 26-B-114KO
- Issued by
- Volusia County, Florida
About this file
This vendor shop drawing document provides security gate construction plans for the Ocean Center located at 101 N. Atlantic Avenue in Daytona Beach, Florida, prepared for Volusia County. The drawings detail the installation specifications for FLASH security gate systems at both the east and west side entry points of the facility. The project scope includes two FLASH Mini Kiosks, TagMaster AVI readers, NEMA enclosures, and vehicle loop detectors for access control integration. The construction plans specify equipment placement, conduit routing, electrical requirements, and mounting details across multiple sheets, with dimensional diagrams and conduit clearance patterns for both full and mini kiosk configurations. The drawings were initially designed on June 10, 2026, and finalized for distribution on June 17, 2026, with no revisions noted in the document.
The technical specifications establish that each kiosk and barrier gate requires dedicated 120-volt, 20-ampere power circuits and individual CAT6 data lines for internet connectivity with minimum bandwidth of 10 megabits per second upload and download speeds. The site requirements include a Master Distribution Frame communication room housing a Merchant Gateway, 4G LTE modem for cloud backup, and an eight-port ProSAFE Gigabit Smart Managed Switch for network routing. All work must comply with current local electrical codes, the National Electrical Code (NFPA 70), and Authority Having Jurisdiction requirements, with local codes taking precedence over shop drawings where conflicts exist. The General Contractor and Electrical Contractor bear responsibility for verifying field conditions prior to installation, and conduit runs between same-island equipment must route internally through the island structure in clean, continuous runs meeting NEC Chapter 9 Table 1 specifications.
View the file
Other files
Show all 42
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
OCEAN CENTER SECURITY GATES
101 N. ATLANTIC AVE
DAYTONA BEACH, FL 32118
FLASH PROJECT # 006Pg0000109PoHIAU
TABLE OF CONTENTS
SHEET NUMBER TITLE
1 COVER PAGE
2 LEGEND
LEVEL 1
3 LEVEL 1 OVERVIEW
4 EAST SIDE ENTRY
5 WEST SIDE ENTRY
TABLE OF REVISIONS
REV # REV DATE DRAWN BY CHECKED BY REVISION DESCRIPTION
0 6/10/2026 RCS CMD INITIAL DESIGN
B
EE
C A
VE
S
R O
A D
, B U
IL
D
IN
G
, S
U
IT
E
0, A
U
ST
IN
, T
X
REV # REV DATE REV INITIALS
SEAL + SIGNATURE
DESIGN TEAM
SHEET TITLE
SHEET NUMBER
CLIENT + PROJECT INFORMATION
FLASH PROJECT NAME
FLASH PROJECT NUMBER
101 N. ATLANTIC AVE
DAYTONA BEACH, FL 32118
NAME DATE
006Pg0000109PoHIAU
OCEAN CENTER SECURITY GATES
6/10/2026
RCS
DATE
June 17, 2026
COVER PAGE
VENDOR SHOP DRAWINGS
(FOR INFORMATIONAL
PURPOSES ONLY)
OCEAN CENTER
CONVENTION CENTER
FLASH EQUIPMENT LEGEND
17" DIA
BASE PLATE
LPR "L" POLE
17" DIA
BASE PLATE
LPR "T" POLE
GENERAL LOCATION OF
FLASH NETWORK DEVICES
NETWORK KIT
FLASH
NETWORK KIT
MAX 1.2A 12-24V DC
READER 12"x12"x1"
WIEGAND OUTPUT
HID LONG RANGE
READER
MAX 2.5A, 120V AC
10'-20' BOOM
STRAIGHT OR
ARTICULATING
BARRIER GATE
IF INCLUDED IN SCOPE:
41/2" Ø STEEL PIPE
8"x8"x1/4" MOUNTING PLATE
SAFETY YELLOW
OTHERWISE LOCATION IS A
RECOMMENDATION BUT SUPPLIED BY OTHERS
BOLLARD
3'x6' OR 2'x7'
VEHICLE
DETECTION LOOP
12-24V DC
OPTEX OAM
EXPLORER
SENSOR
2"x2" SQ TUBE 4"x4"x1/8" PLATE
SAFETY YELLOW
OPTEX POST
ENTRY & EXIT
LOW VOLTAGE
AVI READER
PROVIDED & CONTROLLED
BY OTHERS
OVERHEAD DOOR
CONTROLLER
ROLL DOOR
CONTROLLER
(BY OTHERS)
SIZE & POWER
REQUIREMENTS VARIES
PER SIGN
SIGNAGE
PED WARNING
OPEN / FULL
X
12V DC, POE
DEDICATED CAT6
CCTV SECURITY
CAMERA
MAX 120V
DATA FROM KISOK
VIA USB CONNECTION
BANK NOTE
RECYCLER (BNR)
1" CONDUIT SIZE CAT6 INTERNAL
WIRE - QTY(2)
CONDUIT CALL OUT EXAMPLE:
18/10 STRANDED & SHIELDED
INTERNAL WIRE - QTY(1)
1" B2,C1
FLASH CONDUIT LEGEND
INTERNAL WIRING
DESIGNATION DESCRIPTION QTY
A 20A 120V CIRCUIT #
B CAT6 ETHERNET #
C 18/10 STRANDED & SHEILDED #
D VEHICLE DETECTION LOOP LEAD IN #
E OEM PROVIDED WIRING #
F 16/2 STRANDED & SHIELDED 24V CIRCUIT #
G LV OR DRY CIRCUIT PROVIDED BY OTHERS #
FULL KIOSK CONDUIT
CLEARANCE AND HOLE PATTERN2-4
SCALE: NTS
16"
11"
2"121
2"
TOP VIEW OF FULL KIOSK
2-5
SCALE: NTS
EQUIPMENT ANCHORING DETAIL
6" CONC. CURB
ANCHOR
BOLT(4 TYP)
FRONT VIEW OF FULL & MINI KIOSK
CONDUIT
PENETRATION
BARRIER GATE CONDUIT CLEARANCE
AND HOLE PATTERN2-2
SCALE: NTS
10"
9" 131 2"
2"
TOP VIEW OF BARRIER GATE
TRAFFIC ISLAND
6" CURB
10" 10"
CONDUIT SWEEP FOR VEHICLE
DETECTION LOOPS - FULL KIOSK2-6
SCALE: NTS
FULL KIOSK
BARRIER GATE
3"
2-1
SCALE: NTS
2"
2"71
2"
2"
TOP VIEW OF MINI KIOSK
MINI KIOSK CONDUIT CLEARANCE
AND HOLE PATTERN
TRAFFIC ISLAND
6" CURB
10"
MINI KIOSK
CONDUIT SWEEP FOR VEHICLE
DETECTION LOOPS - MINI KIOSK2-3
SCALE: NTS
7"
BARRIER GATE
3"
CONDUIT SWEEP REQUIRED FOR VEHICLE DETECTION LOOPS
· 3
4" PVC FROM BASE OF CURB TO CENTER OF CONDUIT CLUSTER.
· PREFORMED LOOPS WET CUT 34" - 1" DEEP IN SLAB.
· EACH GATE & KIOSK GETS TYPICAL 3'X'6 LOOP WITH 50' LEAD (2 PER DRIVE LANE)
NOTE: ALL CONDUIT STUB UPS TO BE CENTERED UNDER EACH PIECE OF EQUIPMENT
NOTE: NOT ALL EQUIPMENT SHOWN HERE USED. SEE OVERVIEW PAGES FOR BILL OF MATERIALS.
DEDICATED CAT6
VISION
LPR CAMERA
12-24V DC
OPTEX OVS-02-GT
SENSOR
8'x2"x2" SQ TUBE 8"x8"x1/4" BASE PLATE
UNIVERSAL
MOUNTING POLE
(3) QTY CAT6, POE
MEGASTIX IP
CAMERAS
(1) QTY CAT6, POE
12.1W MAX
AXIS P3265 WALL
MOUNTED
FLEXIBLE DELINEATOR
WHITE, 36" OR 48" TALL
DELINEATOR
USED FOR MOUNTING OF
3RD PARTY READERS
GOOSENECK
PEDSTAL
3'x2"x2" SQ TUBE 8"x8"x1/4" BASE PLATE
FRONT CAPTURE
LPR POLE
6" SQUARE BASEPLATE
HEIGHT VARIES BASED ON
QUOTED POLE
SIGNALTECH POST
WITH SIGN
BRACKET
ENTRY & EXIT
(2) DEDICATED CAT6
HTS LPR CAMERAS
ENTRY & EXIT
MAX 8A, 120V AC
DEDICATED CAT6
FLASH KIOSK
ENTRY & EXIT
MAX 8A, 120V AC
DEDICATED CAT6
FLASH MINI KIOSK
MAX 14A, 120V AC
DEDICATED CAT6
FLASH WALL
MOUNT KIOSK
MAX 4.2A 24V DC
1 CAT6
PEDESTRIAN
ACCESS DOOR
READER
NEMA 3R
120V MAX
DEDICATED CAT6
ACCESS CONTROL
KIT
1. FOUNDATIONS & MOUNTING
1.1. CONCRETE ISLANDS SUPPORTING IN-LANE KIOSKS AND GATES SHALL BE CONSTRUCTED TO A FINISHED HEIGHT OF
6 INCHES ABOVE ADJACENT ASPHALT OR CONCRETE SURFACES. PAD SHALL BE LEVEL, CURED PRIOR TO
EQUIPMENT INSTALLATION & SUFFICIENTLY REINFORCED TO SUPPORT EQUIPMENT LOADS.
1.2. FINAL ELEVATIONS SHALL ENSURE ALL EQUIPMENT IS ACCESSIBLE AND COMPLIANT WITH ADA AND
MANUFACTURER REQUIREMENTS
2. CABLING & DISTANCES
2.1. ALTERNATE SOLUTIONS (E.G. FIBER CONVERSION,GAMECHANGER CALBE, EXTENDERS, ETC.) ARE REQUIRED FOR
CAT 6 CABLE RUNS EXCEEDING 328 FEET (100 METERS)
3. CONDUIT ROUTING
3.1. CONDUIT RUNS BETWEEN EQUIPMENT ON THE SAME ISLAND SHALL BE ROUTED INTERNALLY THROUGH THE ISLAND
3.2. CONDUIT SHALL BE INSTALLED IN A CLEAN, CONTINUOUS RUN WITH NO UNNECESSARY BENDS
3.3. MINIMUM CONDUIT SIZE SHALL MEET CABLE FILL REQUIREMENT PER NEC CHAPTER 9, TABLE 1
4. CODE COMPLIANCE
4.1. ALL WORK SHALL COMPLY WITH CURRENT LOCAL ELECTRICAL CODES, NEC (NFPA 70), AND ANY AHJ (AUTHORITY
HAVING JURISDICTION) REQUIREMENTS.
4.2. LOCAL CODES AND REGULATIONS TAKE PRECEDENCE OVER PROVIDED SHOP DRAWINGS WHERE DISCREPANCIES
EXIST
5. COORDINATION & RESPONSIBILITIES
5.1. THE GENERAL CONTRACTOR (GC) AND ELECTRICAL CONTRACTOR (EC) ARE RESPONSIBLE FOR VERIFYING ALL
FIELD CONDITIONS PRIOR TO INSTALLATION
6. POWER REQUIREMENTS
6.1. POWER CIRCUITS SHALL BE DEDICATED AND PROTECTED PER FLASH SPECIFICATIONS
7. SAFETY & ACCESS
7.1. MAINTAIN CLEARANCES PER EQUIPMENT MANUFACTURER GUIDELINES TO ALLOW FOR SERVICE AND
MAINTENANCE
7.2. ENSURE NO OBSTRUCTIONS (BOLLARDS, CURBS, WALLS, SIGANAGE, ETC.) INTERFERE WITH EQUIPMENT
OPERATION
EQUIPMENT / SITE REQUIREMENTS - GENERAL NOTES
PM MODULAR
POLE
7" X 7" SQUARE BASE PLATE
3" X 3" SQUARE POLE
B
EE
C A
VE
S
R O
A D
, B U
IL
D
IN
G
, S
U
IT
E
0, A
U
ST
IN
, T
X
REV # REV DATE REV INITIALS
SEAL + SIGNATURE
DESIGN TEAM
SHEET TITLE
SHEET NUMBER
CLIENT + PROJECT INFORMATION
FLASH PROJECT NAME
FLASH PROJECT NUMBER
101 N. ATLANTIC AVE
DAYTONA BEACH, FL 32118
NAME DATE
006Pg0000109PoHIAU
OCEAN CENTER SECURITY GATES
6/10/2026
RCS
DATE
June 17, 2026
VENDOR SHOP DRAWINGS
(FOR INFORMATIONAL
PURPOSES ONLY)
OCEAN CENTER
LEGEND
RO
LL
D
OO
R
CO
NT
RO
LL
ER
(B
Y
OT
HE
RS
ROLL DOOR
CONTROLLER
(BY OTHERS)
EAST SIDE ENTRY
OCEAN CENTER SECURITY GATES
EQUIPMENT SHOWN:
· FLASH MINI KIOSK (2)
· TAGMASTER AVI READERS (2)
· NEMA ENCLOSURE (2)
· ALL VEHICLE LOOP DETECTORS INCLUDED
SCALE: 1" = 40'
WEST SIDE ENTRY
TABLE OF CONTENTS
SHEET NUMBER TITLE
LEVEL 1
3 LEVEL 1 OVERVIEW
4 EAST SIDE ENTRY
5 WEST SIDE ENTRY
SITE REQUIREMENTS
Every kiosk and barrier gate will need access to a 120V 20A power circuit and access to an individual data line for each internal component that requires Internet access (minimum of 10 up 10 down MBPs). CAT6 is preferred.
● Sample conduit runs for parking islands (attached)
● Equipment dimensions (attached) *The entry and exit kiosk all have the same dimension.
MDF “COMMUNICATION ROOM” -
● Merchant Gateway -Gateway communication from the equipment to the Internet. This unit is included in the base bid as part of the “Network Kit”
● 4G LTE Modem – Provides temporary back up to the cloud if location loses primary Internet. This unit is included in base bid as part of the “Network Kit”
● ProSAFE® 8-port Gigabit Smart Managed Switch - Router for parking equipment. This unit is included in base bid as part of the “Network Kit” 25
B
EE
C
A
VE
S R
O A
D , B
U
IL
D
IN
G
, S U
IT
E
0, A U
ST
IN
, T X
REV # REV DATE REV INITIALS
SEAL + SIGNATURE
DESIGN TEAM
SHEET TITLE
SHEET NUMBER
CLIENT + PROJECT INFORMATION
FLASH PROJECT NAME
FLASH PROJECT NUMBER
101 N. ATLANTIC AVE
DAYTONA BEACH, FL 32118
NAME DATE
006Pg0000109PoHIAU
OCEAN CENTER SECURITY GATES
6/10/2026
RCS
DATE
June 17, 2026
N
VENDOR SHOP DRAWINGS
(FOR INFORMATIONAL
PURPOSES ONLY)
OCEAN CENTER
LEVEL 1 OVERVIEW
R O
LL
D
O O
R C
O N
TR
O
LL
ER
(B Y
O
TH
ER
S)
10'-10"
2'
6"
TYP
1'-6"
1'-6"
10"
1'-6"
1'
5'-2"
13'-4"
7'-6"
FROM CENTER OF
MOUNTING POLE
TO GATE
USING THE SAME ISLAND
LOCATION INDICATED
IN THE PLANS
10'
FROM LOOP
TO GATE
A NEMA BOX WITH A
LOOP DETECTOR KIT
IS REQUIRED. FINAL
LOCATION ON SITE
BY OTHERS7"
R O
LL
D
O O
R C
O N
TR
O
LL
ER
(B Y
O
TH
ER
S)
1" A1
1" B3
1" D1
1" B1,C1,G1
1" G1 1" B1,C1
1" B2
QTY (1) 20A 120V CIRCUITS REQUIRED
FROM CLOSEST SOURCE
QTY (3) CAT6 REQUIRED FROM
NETWORK ROOM
1" A1
N
SCALE: 1" = 2'
DIMENSIONAL DETAILS
SCALE: 1" = 2'
CONDUIT DETAILS
B
EE
C A
VE
S
R O
A D
, B U
IL
D
IN
G
, S
U
IT
E
0, A
U
ST
IN
, T
X
REV # REV DATE REV INITIALS
SEAL + SIGNATURE
DESIGN TEAM
SHEET TITLE
SHEET NUMBER
CLIENT + PROJECT INFORMATION
FLASH PROJECT NAME
FLASH PROJECT NUMBER
101 N. ATLANTIC AVE
DAYTONA BEACH, FL 32118
NAME DATE
006Pg0000109PoHIAU
OCEAN CENTER SECURITY GATES
6/10/2026
RCS
DATE
June 17, 2026
N
VENDOR SHOP DRAWINGS
(FOR INFORMATIONAL
PURPOSES ONLY)
OCEAN CENTER
EAST SIDE ENTRY
10'-10"
2'
6"
TYP
7" 1'-6"
1'-6"
10"
1'-6"
1'
5'-2"
5'-2"
FROM CENTER OF
MOUNTING POLE
TO GATE
ROLL DOOR
CONTROLLER
(BY OTHERS)
USING THE SAME ISLAND
LOCATION INDICATED
IN THE PLANS
A NEMA BOX WITH A LOOP
DETECTOR KIT IS
REQUIRED. FINAL
LOCATION ON SITE
BY OTHERS
7'-8"
FROM LOOP
TO GATE
1" D1
1" B1,C1,G1
1" B1,C1
ROLL DOOR
CONTROLLER
(BY OTHERS)
1" G1
1" A1
1" B3
1" B2
QTY (1) 20A 120V CIRCUITS REQUIRED
FROM CLOSEST SOURCE
QTY (3) CAT6 REQUIRED FROM
NETWORK ROOM
1" A1
N
SCALE: 1" = 2'
DIMENSIONAL DETAILS
SCALE: 1" = 2'
CONDUIT DETAILS
B
EE
C A
VE
S
R O
A D
, B U
IL
D
IN
G
, S
U
IT
E
0, A
U
ST
IN
, T
X
REV # REV DATE REV INITIALS
SEAL + SIGNATURE
DESIGN TEAM
SHEET TITLE
SHEET NUMBER
CLIENT + PROJECT INFORMATION
FLASH PROJECT NAME
FLASH PROJECT NUMBER
101 N. ATLANTIC AVE
DAYTONA BEACH, FL 32118
NAME DATE
006Pg0000109PoHIAU
OCEAN CENTER SECURITY GATES
6/10/2026
RCS
DATE
June 17, 2026
N
VENDOR SHOP DRAWINGS
(FOR INFORMATIONAL
PURPOSES ONLY)
OCEAN CENTER
WEST SIDE ENTRY
| Sheets and Views |
| FLASH_OCEAN CENTER SECURITY GATES_061026_R0-1 |
| FLASH_OCEAN CENTER SECURITY GATES_061026_R0-2 |
| FLASH_OCEAN CENTER SECURITY GATES_061026_R0-3 |
| FLASH_OCEAN CENTER SECURITY GATES_061026_R0-4 |
| new |
FLASH_OCEAN CENTER SECURITY GATES_061026_R0-5
File details come from the government source that posted it. Updated .