Exhibit_D_-_Plans_REVISION_1.pdf

PDF 33 MB Posted

Attached to
CDBG-DR Lantern Park Stormwater Pond Construction
Solicitation number
26-B-119KW
Issued by
Volusia County, Florida

About this file

Exhibit D - Plans Revision 1 Summary

This document is a technical plans file for Volusia County's Office of Recovery and Resiliency stormwater construction project in South Daytona, Florida. The project encompasses the design and construction specifications for the Lantern Park Stormwater Pond improvements, a critical infrastructure initiative funded through HUD's Community Development Block Grant for Disaster Recovery (CDBG-DR) program. The work involves excavation of approximately 47,986 cubic yards of storage pond capacity to a depth of 10 feet with 3:1 slopes, installation of dual MWI SEA310 axial flow pumps rated at 25 HP each with a combined 2,400-gallon-per-minute capacity, approximately 1,500 linear feet of 18-inch HDPE forcemain piping to Reed Canal with flap gate outlet, installation of junction boxes and riprap ditch lining covering approximately 946 square feet, black vinyl-coated fencing, performance turf restoration, and associated mechanical and electrical infrastructure. The non-mandatory pre-bid meeting is scheduled for August 27, 2026, with questions due by September 3, 2026 at 11:59 p.m., and bid opening on September 17, 2026 at 3:00 p.m. via Microsoft Teams. Substantial completion is required within 360 days of Notice to Proceed, with final completion within 390 days total.

The estimated construction cost is $3.917 million, funded entirely through CDBG-DR recovery grant financing for Hurricane Ian disaster recovery efforts. The project is subject to Davis-Bacon Act prevailing wage requirements with 34 labor classifications ranging from $8.44 to $31.50 per hour base wage plus fringe benefits, requiring weekly certified payroll submissions on WH-347 forms. Contractors must comply with Section 3 requirements mandating at least 25 percent of total labor hours performed by Section 3 workers and at least 5 percent by Targeted Section 3 workers, and must demonstrate affirmative action in utilizing minority and women-owned business enterprises. Bid bonds of 5 percent of bid price, performance bonds for 100 percent of contract price, and payment bonds for 100 percent of contract price are required. Liquidated damages are assessed at $1,200 per day for delays beyond the completion date, and bids must remain firm for 120 days following opening.

View the file

Other files

File Type Posted
CDBG-DR_Lantern_Park_Stormwater_Pond_Construction_(Addendum_#6_Revision).pdf PDF
EXHIBIT_Q_-_City_Utilities_Asbuilt_Map.pdf PDF
EXHIBIT_P_-_TOPOGRAPHIC_SURVEY.pdf PDF
Exhibit_F_-_Bid_Price_Sheet_REVISION_1.xlsx XLSX spreadsheet
Exhibit_E_-_Technical_Specifications_-REVISION_2.pdf PDF
CDBG-DR_Lantern_Park_Stormwater_Pond_Construction_(Addendum_#2_Revision).pdf PDF
Exhibit_E_-_Technical_Specifications_-REVISION_1.pdf PDF
CDBG-DR_Lantern_Park_Stormwater_Pond_Construction.pdf PDF
Exhibit_A_-_Required_Types_and_Limits_of_Insurance.pdf PDF
Exhibit_F_-_Bid_Price_Sheet.xlsx XLSX spreadsheet
Exhibit_N_-_HEAVY_Wage_Determination_(3).pdf PDF
Exhibit_G_-_Project_Sign_(6).pdf PDF
Exhibit_J_-_WH347_Certified_Payroll_Form_January_2025_(3).pdf PDF
Exhibit_D_-_Plans.pdf PDF
Exhibit_M_-_Bonding_Requirements_24_CFR_PART_85.36_(4).pdf PDF
Exhibit_I_-_Instructions_for_Completing_Payroll_Form,_WH-347_Updated_January_2025_(3).pdf PDF
Exhibit_E_-_Technical_Specifications.pdf PDF
Exhibit_H_-_Supplemental_Conditions_(4).pdf PDF
Exhibit_K_-_MWBE_Information_and_Form_(3).pdf PDF
Exhibit_L_-_Section_3_Information_&_Forms_(3).pdf PDF
Exhibit_O_-_Geosyntec_Lantern_Park_Design_Drainage_Report_2026-06-12_S&S.pdf PDF
Exhibit_C_-_Draft_Contract_26-B-119KW.pdf PDF
Exhibit_B_-_Prime_Sub_Form.xls XLS spreadsheet
Exhibit_H_-_Supplemental_Conditions.pdf PDF
Fillable_Cost_Estimate.xlsx XLSX spreadsheet
Geosyntec_Lantern_Park_Final_2026-06-12_S&S.pdf PDF
Lantern_Park_Stomrwater_Improvements_Project_Description.docx DOCX document
Exhibit_J_-_WH347_Certified_Payroll_Form_January_2025.pdf PDF
Geosyntec_Lantern_Park_Design_Drainage_Report_2026-06-12_S&S.pdf PDF
Geosyntec_Lantern_Park_Pond_Tech_Specs_2026-06-12.pdf PDF
Instructions_for_Completing_Payroll_Form,_WH-347_Updated_January_2025.pdf PDF
1-PRIME-SUB_Form_-_Lantern_Park.xls XLS spreadsheet
Exhibit_I_-_Instructions_for_Completing_Payroll_Form,_WH-347_Updated_January_2025.pdf PDF
Exhibit_K_-_MWBE_Information_and_Form.pdf PDF
Exhibit_L_-_Section_3_Information_&_Forms.pdf PDF
Exhibit_G_-_Project_Sign.pdf PDF
Exhibit_M_-_Bonding_Requirements_24_CFR_PART_85.36.pdf PDF
Exhibit_N_-_HEAVY_Wage_Determination.pdf PDF
GEOSYNTEC_LANTERN_PARK_POST_DESIGN_SCOPE_2026-06-12.pdf PDF