Exhibit C - SPI AG00000662.pdf
PDF 231 KB Posted
- Attached to
- AMMPS Spares - Generators Sets Federal contract opportunity
- Solicitation number
- SPRBL1-22-R-0023
About this file
This document outlines a Request for Proposal for spare parts to support the Advanced Medium Mobile Power Source system. The Defense Logistics Agency Land and Maritime is soliciting proposals for an Indefinite-Delivery, Indefinite-Quantity contract over five base years and five option years to supply sixteen National Stock Number line items of generators, engines, and control equipment. The minimum contract value is $30,000 and maximum is $75 million. Proposals are due by October 31, 2022. Cummins Power Generation is the approved sole source as the original equipment manufacturer. Access to technical drawings is restricted under International Traffic in Arms Regulations and requires an active status in the Defense Logistics Agency Joint Certification Program.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Exhibit B - SPI AG00000605C.pdf | ||
| SPRBL122R0023.pdf | ||
| Attachment 0001 - Pricing Spreadsheet.xlsx | XLSX spreadsheet | |
| Attachment 0002 - Delivery Schedule.xlsx | XLSX spreadsheet | |
| Exhibit A - Technical Requirements Document.pdf | ||
| Attachment 0003 - Unit Price Weightings.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SPECIAL PACKAGING INSTRUCTION
Form Approved
OMB No. 0704-0188
1. PART OR DRAWING NO.
ALTERNATOR, GENERATOR
2. CODE IDENT
80063
3. SPI NO.
AG00000662
4. NATIONAL STOCK NO
VARIOUS
5. DATE OF DRAWING
19191
6. REVISION
7. QUP
8. ICQ
NONE
9.UNIT PACK WEIGHT 10.UNIT PACK CUBE 11.UNIT PACK SIZE
12. PRESERVATION 18.
STEPS
19.
REQD
20.
DESCRIPTION
MILITARY
MIL-STD-2073-1E, Note 1
N/A N/A N/A
13. CLEANING
MIL-STD-2073-1E
APPLICABLE DOCUMENTS
DDSFSDFDF
14. DRYING
MIL-STD-2073-1E
MIL-STD-2073-1E ASTM D6256
MIL-STD-129R ISPM 15
SAE AS26860
15. PACKING
a. LEVEL A
Note 2
b. LEVEL B
N/A
16. MARKING
MIL-STD-129R and Note 3
17. NOTES/DRAWING
1. PRESERVATION.
1.1 Generator Alternator. Preserve "Method 53 Floating Watervaporproof bag, sealed" with desiccant. The Unit Container shall be an ASTM D6256 Type
I, Class 2, Style A, Wood Cleated Box with Skidded Load-Bearing Base using lag bolts or other reusable hardware. Base shall be full panel plywood with plywood panels on ends, sides and top. Use bolts to secure the generator(alternator) to the load bearing base of the ASTM D6256 container.
Before sealing the barrier bag, be sure to block and/or brace the Main Rotor Assembly to be physically separated from the
Main Stator.
See “Fig. 1” as an example. An inspection port is required to coincide with the location of the humidity indicator to view the humidity indicator installed in the bag. Indicator shall comply with SAE AS26860, Type
II.
DA FORM 2169, JUN 86 Page 1 of 2
SPECIAL PACKAGING INSTRUCTION
(Continuation Sheet )
Form Approved
OMB No. 0704-0188
1. PART OR DRAWING NO.
ALTERNATOR, GENERATOR
2. CODE IDENT
80063
3. SPI NO.
AG00000662
4. NATIONAL STOCK NO
VARIOUS
5. DATE
19191
6. REVISION
2. PACKING.
2.1 Level A. The unit container will serve as the shipping container.
3. MARKING.
3.1 Marking. Marking shall be in accordance with MIL-STD-129.
3.2 Special marking. See ASTM D6256 for special container markings. The words “REUSABLE CONTAINER” and “METHOD 50” shall be marked on the identification-marked side and one end of the container.
3.2.1 A warning tag shall be prepared and attached to all new or repaired alternators which alerts the receiver to locate and complete the DA Form
2404, "Equipment Inspection and Maintenance Worksheet", prior to return shipment. The following statement will be included on the warning tag:
"Information describing the deficiencies of the equipment that placed it into inoperable status shall be documented on DA Form 2404 "Equipment Inspection and Maintenance Worksheet" and returned with the unserviceable equipment."
The data recorded on DA Form 2404 will aid in future repairs of the alternator, improve cost reduction initiatives, and provide feedback to help update maintenance technical manuals.
3.2.2 A copy of the DA Form 2404, "Equipment Inspection and Maintenance
Worksheet", will be included with new or repaired alternators and placed in a prominent location inside the unit container prior to shipment.
4. Requirements For Wood Packaging Material. All CONUS and OCONUS shipments utilizing wood packaging material, such as pallets, dunnage, crating, packing blocks, drums, cases, load boards, pallet collars, and skids, shall meet the
International Standards for Phytosanitary Measures, ISPM 15, entitled
“Regulation of Wood Packaging Material in International Trade”.
5. Container Reuse. A warning tag shall be prepared and attached to the generator alternator with the following instuctions, “Whenever possible, reuse existing container, bolts, blocking and bracing to return the unserviceable generator alternator.”
DA FORM 2169C, JUN 86 Page 2 of 2
File details come from the government source that posted it. Updated .