This is a USGS Master Library of Typical Spaces template used for documenting and budgeting various office and support facility types. The document serves as a reference guide for space planning and cost estimation across multiple room categories.
The template covers private offices in four tiers: Deluxe (6 needed, 125 sq ft, $39,600 in upgrades), Standard (8 needed, 100 sq ft, $4,000 in upgrades), Economy (8 needed, 100 sq ft, no upgrades), and Shared (24 needed, 110 sq ft, $12,000 in upgrades). Open workstations include Small (30 needed, 48 sq ft) and Touchdown (8 needed, 36 sq ft) configurations, totaling 40 workstations for 107 staff. Meeting spaces consist of Large Conference Rooms (2 needed, 250 sq ft each), Medium Conference Room (1 needed, 180 sq ft), and Small Conference Room (0 needed, 110 sq ft). General support spaces include Break Rooms (2 needed, 150 sq ft each), Utility Room (1 needed, 150 sq ft), Layout Room (1 needed, 180 sq ft), Shower Rooms (2 needed, 64 sq ft each), Reception Desk and Waiting (1 needed, 144 sq ft), Small Library (0 needed, 600 sq ft), and Computer Lab (0 needed, 300 sq ft). Each space type includes detailed specifications for walls, flooring, ceiling, doors, lighting, electrical, HVAC, casework, signage, and furniture, with optional upgrades such as full glass office fronts and full-height acoustic walls. The document is designed for yellow-highlighted fields to be completed by users with reference to a separate Cover Sheet for totals.
View the file
Other files
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
USGS Master Library of Typical Spaces Fill Out "Yellow" Highlighted Boxes Only
Private Offices Reference 'Cover Sheet' for Totals
DELUXE PRIVATE OFFICE QTY NEEDED: 6
# of offices Staff:
$$$$ Square Foot Per Office 125 Image Example of Space 1 ORWSC Director
1 ORWSC Assoc Director Key Features 1 ORWSC Deputy Director Approx Size: 1 ORWSC Admin Officer Seat Count: 2 NWPIR Director/Deputy Director Walls:
Floor:
Ceiling:
Door/Glazing:
Lighting:
Electrical:
HVAC:
Casework:
Signage:
AV:
Equipment:
Furniture:
Not Included: AV, Equipment, and Furniture listed above is for reference only, it is not included in this budget.
Upgrades (Check Desired - Applies it to all Deluxe Private Offices) Cost Addition Per Office Total
TRUE Full Glass Office Front $6,000.00 $36,000.00 TRUE Full Height Walls to Deck (Added Acoustics) $600.00 $3,600.00
Sum of Upgrades $39,600.00
STANDARD PRIVATE OFFICE QTY NEEDED: 8
# of offices Staff:
$$$ Square Foot Per Office 100 Image Example of Space 1 PFO Supervisor
1 WVFO Supervisor Key Features 1 QA/QC Section Supervisor Approx Size: 1 SFOT Supervisor Seat Count: 0 GW Team Supervisor Walls:
1 Geomorphology Team Supervisor Floor: 1 Ecology Team Supervisor Ceiling: 1 SW Team Supervisor Door/Glazing:
1 NWPIR Management Analyst Lighting:
Electrical:
HVAC:
Casework:
Signage:
AV:
Equipment:
Furniture:
Not Included: AV, Equipment, and Furniture listed above is for reference only, it is not included in this budget.
Upgrades (Check Desired - Applies it to all Standard Private Offices) Cost Addition Per Office Total FALSE Full Glass Office Front $6,000.00 FALSE TRUE Full Height Walls to Deck (Added Acoustics) $500.00 $4,000.00
Sum of Upgrades $4,000.00
Drywall with painted finish, installed from finish floor to 6" above ceiling, acoustically treated to provide an STC rating of 45
Building standard acoustical lay-in ceiling, with minimum NRC of 0.55, CAC of 35, and LR of 85 Stained, solid-core wood interior door with sound gaskets, full-length glass sidelite 18" wide, building standard frame. Building standard window coverings at exterior glazing.
*optional - full glass office front, check in upgrades below if desired Building standard office lighting, 35 foot-candles at a height of 30", dual level switch and daylighting controls 4 duplex outlets, 2 data drops Building standard heating and air conditioning with private thermostat (**Note by checking full height wall upgrade below it could affect mechanical systems and cause a mechanical cost increase - it causes returns to be ducted instead of having the possibility of plenum returns - also adds cost for working around full height framing) None Building standard identification sign outside door None None Desk and desk with storage, Guest chair
10 x 12, approx 110 - 130 square feet 1, up to 2-3 guests Drywall with painted finish, installed from finish floor to 6" above ceiling, acoustically treated to provide an STC rating of 45
Building standard carpet with rubber base Building standard acoustical lay-in ceiling, with minimum NRC of 0.55, CAC of 35, and LR of 85 Stained, solid-core wood interior door with sound gaskets, full-length glass sidelite 18" wide, building standard frame. Building standard window coverings at exterior glazing.
*optional - full glass office front, check in upgrades below if desired
Building standard carpet with rubber base
Building standard office lighting, 35 foot-candles at a height of 30", dual level switch and daylighting controls 6 duplex outlets, 2 data drops Building standard heating and air conditioning with private thermostat (**Note by checking full height wall upgrade below it could affect mechanical systems and cause a mechanical cost increase - it causes returns to be ducted instead of having the possibility of plenum returns - also adds cost for working around full height framing) None Building standard identification sign outside door None None Desk and desk with storage, 2 guest chairs
10' x 10' or 12', approx 100 - 120 square feet 1, up to 2 guests
Check
Check Check
Check
EXHIBIT C
LESSOR:______GOVERNMENT:______
Private Offices Reference 'Cover Sheet' for Totals
ECONOMY PRIVATE OFFICE QTY NEEDED: 8
# of offices Staff:
$$ Square Foot Per Office 100 Image Example of Space 1 Management Analyst
1 Budget Analyst Key Features 1 SFOT Support Supervisor Approx Size: 1 Geomorphology Support Supervisor Seat Count: 3 GW/WQ/SW Specialists Walls:
1 EFO Supervisor Floor:
Ceiling:
Door/Glazing:
Lighting:
Electrical:
HVAC:
Casework:
Signage:
AV:
Equipment:
Not Included: AV, Equipment, and Furniture listed above is for reference only, it is not included in this budget.
Upgrades (Check Desired - Applies it to all Economy Private Offices) Cost Addition Per Office Total FALSE Full Glass Office Front $6,000.00 FALSE FALSE Full Height Walls to Deck (Added Acoustics) $500.00 FALSE
Sum of Upgrades $0.00
SHARED PRIVATE OFFICE QTY NEEDED: 24 # of staff # of offices Staff:
$$ Square Foot Per Office 110 Image Example of Space 2 1 IT staff (2 staff)
6 3 GW Team (6 staff) Key Features 4 2 Geomorphology Team (4 staff) Approx Size: 3 2 Ecology Team (3 staff) Seat Count: 5 3 SW Team (5 staff) Walls:
9 5 QA/QC Team (9 staff) Floor: 12 6 Non-ORWSC (12 staff) Ceiling: 2 1 Safety Officer and Eng Tech (Marc's staff) Door/Glazing:
2 1 Research Scientists (Alex's staff) Lighting:
Electrical:
HVAC:
67 Private offices # staff Casework: 40 Open Workstations # staff Signage: 107 Total # staff
AV:
Equipment:
Furniture:
Not Included: AV, Equipment, and Furniture listed above is for reference only, it is not included in this budget.
Upgrades (Check Desired - Applies it to all Economy Private Offices) Cost Addition Per Office Total FALSE Full Glass Office Front $6,000.00 FALSE TRUE Full Height Walls to Deck (Added Acoustics) $500.00 $12,000.00
Sum of Upgrades $12,000.00
(2) desks with storage
Drywall with painted finish, installed from finish floor to underside of suspended ceiling, acoustically treated to provide an STC rating of 35 Building standard carpet with rubber base Building standard acoustical lay-in ceiling, with minimum NRC of 0.55, CAC of 35, and LR of 85
Stained, solid-core wood interior door with sound gaskets, full-length glass sidelite 18" wide, building standard frame. Building standard window coverings at exterior glazing.
*optional - full glass office front, check on front page
Building standard office lighting, 35 foot-candles at a height of 30", dual level switch and daylighting controls 4 duplex outlets, 2 data drops Building standard heating and air conditioning with shared thermostat (**Note by checking full height wall upgrade below it could affect mechanical systems and cause a mechanical cost increase - it causes returns to be ducted instead of having the possibility of plenum returns - also adds cost for working around full height framing) None Building standard identification sign outside door None None
Desk with Storage - Guest chair
12' x 10 or 12'x12', approx 120 - 140 square feet
None Building standard identification sign outside door None None
Furniture:
10' x 10', approx 100 square feet
Drywall with painted finish, installed from finish floor to underside of suspended ceiling, acoustically treated to provide an STC rating of 35
1, up to 2 guests
Building standard carpet with rubber base Building standard acoustical lay-in ceiling, with minimum NRC of 0.55, CAC of 35, and LR of 85
Stained, solid-core wood interior door with sound gaskets and vision lite, building standard frame. Building standard window coverings at exterior glazing.
*optional - full glass office front, check in upgrades below if desired
Building standard office lighting, 35 foot-candles at a height of 30", single level switch and daylighting controls
2 duplex outlets, 1 data drops
Building standard heating and air conditioning with shared thermostat (**Note by checking full height wall upgrade below it could affect mechanical systems and cause a mechanical cost increase - it causes returns to be ducted instead of having the possibility of plenum returns - also adds cost for working around full height framing)
Check Check
Check Check
Open Workstations Reference 'Cover Sheet' for Totals
DELUXE OPEN OFFICE WORKSTATION QTY NEEDED: 0
$$ Square Feet Per Workstation 80 Image Example of Space
Key Features Approx Size: 8' x 10', approx 80 square feet Seat Count: 1, up to 2 guests Walls: None Floor: Building standard carpet with rubber base Ceiling: Building standard acoustical lay-in ceiling, with minimum NRC of 0.55, CAC of 35, and LR of 85 Door/Glazing: None Lighting: Building standard office lighting, 35 foot-candles at a height of
30" Electrical: J-box for furniture power connection, 1 data drop HVAC: Building standard heating and air conditioning with shared thermostat Casework: None Signage: None AV: None Equipment: None Furniture:
Not Included: AV, Equipment, and Furniture listed above is for reference only, it is not included in this budget.
STANDARD OPEN OFFICE WORKSTATION QTY NEEDED: 0
$ Square Feet Per Workstation 64 Image Example of Space
Key Features Approx Size: 8' x 8', approx 64 square feet Seat Count: 1 Walls: None Floor: Building standard carpet with rubber base Ceiling: Building standard acoustical lay-in ceiling, with minimum NRC of 0.55, CAC of 35, and LR of 85 Door/Glazing: None Lighting: Building standard office lighting, 35 foot-candles at a height of
30" Electrical: J-box for furniture power connection, 1 data drop HVAC: Building standard heating and air conditioning with shared thermostat Casework: None Signage: None AV: None Equipment: None Furniture:
Not Included: AV, Equipment, and Furniture listed above is for reference only, it is not included in this budget.
Panel partitions on 3 sides, U-shape desk
Panel partitions on 3 sides, U-shape desk, 2 guest chairs
Open Workstations Reference 'Cover Sheet' for Totals
SMALL OPEN OFFICE WORKSTATION QTY NEEDED: 30 # of staff # of offices Staff:
$ Square Feet Per Workstation 48 Image Example of Space 7 7 SFOT (7 staff)
12 12 PFO (12 staff) Key Features 8 8 WVFO (8 staff) Approx Size: 6' x 8', approx 48 square feet 3 3 Admin support (3 staff) Seat Count: 1 Walls: None Floor: Building standard carpet with rubber base Ceiling: Building standard acoustical lay-in ceiling, with minimum NRC of 0.55, CAC of 35, and LR of 85 Door/Glazing: None Lighting: Building standard office lighting, 35 foot-candles at a height of
30" Electrical: J-box for furniture power connection, 1 data drop HVAC: Building standard heating and air conditioning with shared thermostat Casework: None Signage: None AV: None Equipment: None Furniture:
Not Included: AV, Equipment, and Furniture listed above is for reference only, it is not included in this budget.
TOUCHDOWN OPEN OFFICE WORKSTATION QTY NEEDED: 8 # of staff # of offices Staff:
< $ Square Feet Per Workstation 36 Image Example of Space 6 6 Summer help / interns (6 staff)
4 2 OWRD cooperator (4 staff) Key Features Approx Size: 6' x 6', approx 36 square feet Seat Count: 1 40 Workstations # staff Walls: None Floor: Building standard carpet with rubber base Ceiling: Building standard acoustical lay-in ceiling, with minimum NRC of 0.55, CAC of 35, and LR of 85 Door/Glazing: None Lighting: Building standard office lighting, 35 foot-candles at a height of
30" Electrical: J-box for furniture power connection, 1 data drop HVAC: Building standard heating and air conditioning with shared thermostat Casework: None Signage: None AV: None Equipment: None Furniture:
Not Included: AV, Equipment, and Furniture listed above is for reference only, it is not included in this budget.
Panel partitions on 2 sides, L-shape desk
Panel partitions on 1 side, straight desk
Meeting Space Reference 'Cover Sheet' for Totals
LARGE CONFERENCE ROOM QTY NEEDED: 2
$$$ Square Feet per Room 250 Image Example of Space
Key Features Approx Size:
Seat Count:
Walls:
Floor:
Ceiling:
Door/Glazing:
Lighting:
Electrical:
HVAC:
Casework:
Signage:
AV:
Equipment:
Furniture:
Not Included: AV, Equipment, and Furniture listed above is for reference only, it is not included in this budget.
Upgrades (Check Box if Desired and Input Number of Conference Rooms you want this in) Cost Addition Per Room
Number Desired Total
FALSE Add 10'-0" Long Casework (Uppers and Lowers) and Sink to Room $14,000.00 0 FALSE Sum Total $0.00
MEDIUM CONFERENCE ROOM QTY NEEDED: 1
$$ Square Feet per Room 180 Image Example of Space
Key Features Approx Size:
Seat Count:
Walls:
Floor:
Ceiling:
Door/Glazing:
Lighting:
Electrical:
Building standard carpet with rubber base Building standard acoustical lay-in ceiling, with minimum NRC of 0.55, CAC of 35, and LR of 85 duplex outlets every 6 feet, central floor box with power, data, and AV connections
Building standard office lighting, 50 foot-candles at a height of 30", dual level switch and daylighting controls
Marker board Large conference table with power in top, 12 to 18 chairs, credenza approx 150 to 250 square feet 6 to 10 Drywall with painted finish, installed from finish floor to underside of deck above, acoustically treated to provide an STC rating of 45.
Blocking for TV on end wall approx 250 - 400 square feet 12 to 18 Drywall with painted finish, installed from finish floor to underside of deck above, acoustically treated to provide an STC rating of 45.
Blocking for TV on end wall
Building standard carpet with rubber base Building standard acoustical lay-in ceiling, with minimum NRC of 0.55, CAC of 35, and LR of 85
Stained, solid-core wood interior door with sound gaskets, full-length glass sidelite 18" wide, building standard frame. Building standard window coverings at exterior glazing.
*optional - full glass office front, check on front page
Building standard office lighting, 50 foot-candles at a height of 30", dimmable switch and daylighting controls duplex outlets every 6 feet, central floor box with power, data, and AV connections
Stained, solid-core wood interior door with sound gaskets, full-length glass sidelite 18" wide, building standard frame. Building standard window coverings at exterior glazing.
*optional - full glass office front, check on front page
Building standard heating and air conditioning with private thermostat
None Building standard identification sign outside door Large TV display, connectivity at table
Check
Meeting Space Reference 'Cover Sheet' for Totals
HVAC:
Casework:
Signage:
AV:
Equipment:
Furniture:
Not Included: AV, Equipment, and Furniture listed above is for reference only, it is not included in this budget.
Upgrades (Check Box if Desired and Input Number of Conference Rooms you want this in) Cost Addition Per Room
Number Desired Total
FALSE Add 10'-0" Long Casework (Uppers and Lowers) and Sink to Room $14,000.00 0 FALSE Sum Total $0.00
SMALL CONFERENCE ROOM QTY NEEDED: 0
$ Square Feet per Room 110 Image Example of Space
Key Features Approx Size:
Seat Count:
Walls:
Floor:
Ceiling:
Door/Glazing:
Lighting:
Electrical:
HVAC:
Casework:
Signage:
AV:
Equipment:
Furniture:
Not Included: AV, Equipment, and Furniture listed above is for reference only, it is not included in this budget.
PHONE ROOM QTY NEEDED: 0
$ Square Feet per Room 50 Image Example of Space
Key Features Approx Size:
Seat Count:
Building standard acoustical lay-in ceiling, with minimum NRC of 0.55, CAC of 35, and LR of 85
Stained, solid-core wood interior door with sound gaskets, full-length glass sidelite 18" wide, building standard frame. Building standard window coverings at exterior glazing.
*optional - full glass office front, check on front page
Building standard office lighting, 50 foot-candles at a height of 30", dual level switch and daylighting controls
4 duplex outlets, 2 data drops Building standard heating and air conditioning with shared thermostat
None Building standard identification sign outside door TV display Marker board Conference table, 4 to 5 chairs
Building standard carpet with rubber base
Building standard heating and air conditioning with private thermostat
None Building standard identification sign outside door Large TV display, connectivity at table Marker board Conference table with power in top, 6 to 10 chairs, credenza approx 100 to 120 square feet 4 to 5 people Drywall with painted finish, installed from finish floor to underside of deck above, acoustically treated to provide an STC rating of 45.
Blocking for TV on end wall approx 50 square feet
Check
Meeting Space Reference 'Cover Sheet' for Totals
Walls:
Floor:
Ceiling:
Door/Glazing:
Lighting:
Electrical:
HVAC:
Casework:
Signage:
AV:
Equipment:
Furniture:
Not Included: AV, Equipment, and Furniture listed above is for reference only, it is not included in this budget.
OPEN COLLABORATION SPACE QTY NEEDED: 0
$ Square Feet per Room 125 Image Example of Space
Key Features Approx Size:
Seat Count:
Walls:
Floor:
Ceiling:
Door/Glazing:
Lighting:
Electrical:
HVAC:
Casework:
Signage:
AV:
Equipment:
Furniture:
Not Included: AV, Equipment, and Furniture listed above is for reference only, it is not included in this budget.
approx 100-150 square feet
Table with chairs or soft seating
None Building standard carpet with rubber base Building standard acoustical lay-in ceiling, with minimum NRC of 0.55, CAC of 35, and LR of 85
None Building standard office lighting, 35 foot-candles at a height of 30"
1 duplex outlet Building standard heating and air conditioning with shared thermostat
None None None None
6 to 8
None Straight table or chair with side table
Building standard heating and air conditioning with shared thermostat
None Building standard identification sign outside door None
Building standard office lighting, 35 foot-candles at a height of 30", single level switch
1 duplex outlet, 1 data drop
Drywall with painted finish, installed from finish floor to underside of deck above, acoustically treated to provide an STC rating of 45.
Building standard carpet with rubber base Building standard acoustical lay-in ceiling, with minimum NRC of 0.55, CAC of 35, and LR of 85
Stained, solid-core wood interior door with sound gaskets and vision lite, building standard frame. Building standard window coverings at exterior glazing.
General Office and Support Spaces Reference 'Cover Sheet' for Totals
BREAK ROOM QTY NEEDED: 2
$$$ Square Feet per Room 150 Image Example of Space
Key Features Approx Size:
Seat Count:
Walls:
Floor:
Ceiling:
Door/Glazing:
Lighting:
Electrical:
HVAC:
Casework:
Signage:
AV:
Equipment:
Furniture:
Not Included: AV, Equipment, and Furniture listed above is for reference only, it is not included in this budget.
UTILITY ROOM QTY NEEDED: 1
$$$ Square Feet per Room 150 Image Example of Space
Key Features Approx Size:
Seat Count:
Walls:
Floor:
Ceiling:
Door/Glazing:
Lighting:
Electrical:
HVAC:
Casework:
Signage:
12.5' x 16', approx 200 square feet 4-6 Persons Drywall with painted finish, installed from finish floor to 6" above suspended ceiling, acoustically treated to provide an STC rating of 35 Vinyl composition tile, 12" x 12" x 1/8". Vinyl resilient base, with factory formed external and internal corners.
Building standard acoustical lay-in ceiling, with minimum NRC of 0.55, CAC of 35, and LR of 85 Stained, solid-core wood interior door with sound gaskets and vision lite, building standard frame.
10' x 10', approx 100 square feet None.
Drywall with painted finish, installed from finish floor to 6" above suspended ceiling, acoustically treated to provide an STC rating of 35 Vinyl composition tile, 12" x 12" x 1/8", with vinyl resilient base. Factory formed external and internal corners, coved at hard surface flooring.
Refrigerator, Microwave Table with (4) Chairs
Building standard lighting.
Building standard heating and air condition.
Minimum of 10 linear feet of high quality commercial laminate wood base cabinets with matching wall cabinets. Base cabinets shall include a high grade/quality commercial laminate counter top with back and side splash plates as necessary.
Building standard identification sign outside door.
None.
Building standard acoustical lay-in ceiling, with minimum NRC of 0.55, CAC of 35, and LR of 85
Stained, solid-core wood interior door with sound gaskets and vision lite, building standard frame.
Building standard lighting.
6 duplex outlets with 1 data drop. 2 outlets at cabinet counter height.
Building standard heating and air condition.
Minimum of 10 linear feet of high quality commercial laminate wood base cabinets with matching wall cabinets. Base cabinets shall include a high grade/quality commercial laminate counter top with back
Building standard identification sign outside door.
General Office and Support Spaces Reference 'Cover Sheet' for Totals
AV:
Equipment:
Furniture:
Not Included: AV, Equipment, and Furniture listed above is for reference only, it is not included in this budget.
LAYOUT ROOM QTY NEEDED: 1
$$ Square Feet per Room 180 Image Example of Space
Key Features Approx Size:
Seat Count:
Walls:
Floor:
Ceiling:
Door/Glazing:
Lighting:
Electrical:
HVAC:
Casework:
Signage:
AV:
Equipment:
Furniture:
Not Included: AV, Equipment, and Furniture listed above is for reference only, it is not included in this budget.
SHOWER ROOM QTY NEEDED: 2
$$$ Square Feet per Room 64 Image Example of Space
Key Features
None.
None.
None.
15'x12' - approx 180 square feet None.
Drywall with painted finish, installed from finish floor to 6" above suspended ceiling, acoustically treated to provide an STC rating of 35 Building standard carpet with rubber base Building standard acoustical lay-in ceiling, with minimum NRC of 0.55, CAC of 35, and LR of 85
Building standard identification sign outside door.
None.
None.
None.
Stained, solid-core wood interior door with sound gaskets and vision lite, building standard frame.
Building standard office lighting, 50 foot-candles at a height of 30 inches.
4 duplex outlets, 1 data drops.
Building standard heating and air condition.
Minimum of 10 linear feet of high quality commercial laminate wood base cabinets with matching wall cabinets. Base cabinets shall include a high grade/quality commercial laminate counter top with back d id l h l
General Office and Support Spaces Reference 'Cover Sheet' for Totals
Approx Size:
Seat Count:
Walls:
Floor:
Ceiling:
Door/Glazing:
Lighting:
Electrical:
HVAC:
Casework:
Signage:
Plumbing:
AV:
Equipment:
Furniture:
Not Included: AV, Equipment, and Furniture listed above is for reference only, it is not included in this budget.
RECEPTION DESK AND WAITING QTY NEEDED: 1
$$ Square Feet per Room 144 Image Example of Space
Key Features Approx Size:
Seat Count:
Walls:
Floor:
Ceiling:
Door/Glazing:
Lighting:
Electrical:
HVAC:
Casework:
Signage:
AV:
Equipment:
Furniture:
Not Included: AV, Equipment, and Furniture listed above is for reference only, it is not included in this budget.
8'x8' - approx 64 square feet None.
Moisture resistant drywall with painted finish to 6" above ceiling, ceramic tile on backerboard up to 6'-0" above finish floor around the entirety of the room.
Ceramic tile flooring and tile wall base, ABA compliant slope for shower and drains.
Moisture resistant drywall with painted finish.
Stained, solid-core wood interior door with sound gaskets, building standard frame.
Light over mirror, 2 can lights 2 duplex outlets one below and one above countertop height. Outlets will of necessary type to be code compliant (GFI)
Restroom ceiling fan. Building standard heating and air condition.
None.
Building standard identification sign outside door.
None.
None.
None.
Wall hung sink with associated mirror. Shower with associated ABA compliant shower bench.
12'x12' - approx 144 square feet 1-5 Persons
(2) Walls factored in. Drywall with painted finish, installed from finish floor to 6" above suspended ceiling, acoustically treated to provide an STC rating of 35
Building standard carpet with rubber base Building standard acoustical lay-in ceiling, with minimum NRC of 0.55, CAC of 35, and LR of 85 Area to be open to surroundings.
Building standard office lighting, 50 foot-candles at a height of 30 inches.
4 duplex outlets, 2 data drops.
Building standard heating and air condition.
Built in 7'x7' Reception Desk None.
TV display None.
Table, waiting chairs, etc.
General Office and Support Spaces Reference 'Cover Sheet' for Totals
SMALL LIBRARY QTY NEEDED: 0
$$$ Square Feet per Room 600 Image Example of Space
Key Features Approx Size:
Seat Count:
Walls:
Floor:
Ceiling:
Door/Glazing:
Lighting:
Electrical:
HVAC:
Casework:
Signage:
AV:
Equipment:
Furniture:
Not Included: AV, Equipment, and Furniture listed above is for reference only, it is not included in this budget.
COMPUTER LAB QTY NEEDED: 0
$$$ Square Feet per Room 300 Image Example of Space
Key Features Approx Size:
Seat Count:
Walls:
Floor:
Ceiling:
Door/Glazing:
Lighting:
Electrical:
HVAC:
Casework:
Signage:
AV:
Space Maximum is 749 SF. 750 SF and over becomes Special Use Space, See Special Use Space Tab for Large Library
Stained, solid-core wood interior door with sound gaskets, full-length glass sidelite 18" wide, building Building standard lighting.
Building standard electrical. 4 duplex outlets.
Building standard heating and air condition.
20'x30' - approx 600 square feet None.
Drywall with painted finish, installed from finish floor to underside of deck above, acoustically treated to Building standard carpet with rubber base Building standard acoustical lay-in ceiling, with minimum NRC of 0.55, CAC of 35, and LR of 85
20'x15' - approx 300 square feet
Building standard identification sign outside door.
None.
None.
Library stacks.
None.
8 Persons Drywall with painted finish, installed from finish floor to 6" above suspended ceiling, acoustically treated to provide an STC rating of 35
Building standard carpet with rubber base Building standard acoustical lay-in ceiling, with minimum NRC of 0.55, CAC of 35, and LR of 85 Stained, solid-core wood interior door with sound gaskets and vision lite, building standard frame.
None.
Building standard office lighting, 50 foot-candles at a height of 30 inches.
8 duplex outlets, 8 data drops.
Building standard heating and air condition.
None.
Building standard identification sign outside door.
General Office and Support Spaces Reference 'Cover Sheet' for Totals
Equipment:
Furniture:
Not Included: AV, Equipment, and Furniture listed above is for reference only, it is not included in this budget.
Computers Desks, chairs, etc.
File details come from the government source that posted it. Updated .