Exhibit B10 - USCIS Minimum Modeling Matrix.pdf
PDF 3 MB Posted
- Attached to
- GENERAL SERVICES ADMINISTRATION (GSA) SEEKS TO LEASE SPACE IN IMPERIAL, CA - RLP PACKAGE
- Solicitation number
- 2CA1503
About this file
This document is a Minimum Modeling Matrix (M3) that provides detailed requirements and guidance for 3D modeling and facility data for various building elements and systems as part of a federal construction contract. The M3 covers specifications for modeling accuracy (Level of Development) and data formats (Grade) across disciplines such as civil, structural, architectural, mechanical, electrical, and specialty systems. Requirements are organized by the OmniClass and UniFormat classification systems. The M3 includes detailed requirements for modeling and data delivery at the Design/CD and As-Built stages. This is intended to be used as a standardized BIM execution plan for federally-owned or leased facilities.
The related federal contract opportunity is a solicitation for the General Services Administration (GSA) to lease space in Imperial, CA. The solicitation package contains the Request for Lease Proposals (RLP) and associated documents. The objective is to obtain a lease for a new office facility to meet the requirements of the U.S. Citizenship and Immigration Services (USCIS). Key details such as the square footage, lease term, and pricing terms are not provided in the information available.
View the file
Other files
Show all 22
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Minimum Modeling Matrix (M3)
TABLE OF CONTENTS
❶ TAB 1. Instructions
1. General Instructions
2. Definitions
2.1. Level Of Development Definitions (Accuracy)
2.2. Element Grade Definitions (Format)
3. Product‐Specific M3 Guidance
3.1. Autodesk Revit M3 Guidance
4. References
❷ TAB 2. Modeling Requirements
❸ TAB 3. Scope‐LOD‐Grade
Page 1 of 22 Tab 1. Instructions
Exhibit B-10 USCIS Minimum Modeling Matrix
Gov ____ / Lessor ________
1. GENERAL INSTRUCTIONS
1. Filters are available to sort and limit column data in the table.
2. Discipline and Notes columns available as a convenience and are not a contractual requirement.
2. DEFINITIONS
2.1. LEVEL OF DEVELOPMENT DEFINITIONS (ACCURACY)
LOD Definition
Refer to the specific child element for appropriate LOD. (Used for categories that have multiple sub‐ elements for which varying LOD apply.)
Conceptual: Model Elements indicative of area, height, volume, location, and orientation may be modeled geometrically or represented by other data (i.e., a pump would be a cube.)
Approximate Geometry: Model Elements are modeled as generalized systems or assemblies with approximate quantities, size, shape, location, and orientation. Non‐geometric information may also be attached to Model Elements (i.e., a pump would be a generic pump of approximate size.)
Precise Geometry: Model Elements are modeled as specific assemblies accurate in terms of quantity, size, shape, location, and orientation. Non‐geometric information may also be attached to Model
Elements. Accurate to the degree dimensioned or indicated on contract documents (i.e., a pump would be a generic pump of accurate size complete with connections and clearances for a complete system.)
Precise Geometry: The Model Element is graphically represented within the Model as a specific system, object, or assembly in terms of quantity, size, shape, orientation, and interfaces with other building systems. Non‐graphic information may also be attached to the Model Element
Fabrication: The Model Element is graphically represented within the Model as a specific system, object or assembly in terms of size, shape, location, quantity, and orientation with detailing, fabrication, assembly, and installation information. Non‐graphic information may also be attached to the Model Element.
The Model Element is a field verified representation in terms of size, shape, location, quantity, and orientation. Non‐graphic information may also be attached to the Model Elements.
The following LOD descriptions identify the specific element requirements for each Model Element.
Example – light fixture:
100 cost/sf attached to floor slabs
200 light fixture, generic/approximate size/shape/location
300 2x4 troffer, specific size/shape/location
350 Lightolier DPA2G12LS232, specific size/shape/location
400 As 350, plus special mounting details, as in a decorative soffit
Page 2 of 22 Tab 1. Instructions
Exhibit B-10
Grade Description
A 3D + Facility Data
B 2D + Facility Data
C 2D Only (Drafting, linework, text, and or part of an assembly)
+ Original Grade (A, B, or C) adjusted for contract changes and field conditions.
‐ Not included in or tied to the model (however is still required in the deliverable)
Refer to the specific child element for appropriate Grade. (Used for categories that have multiple sub‐elements for which varying Grades apply.)
2.2. ELEMENT GRADE DEFINITIONS (FORMAT)
Within each Level of Development, there is the potential to represent information in various formats. In practice, Attachment H Page 3 of 22 Tab 1. Instructions
Exhibit B-10
3. Product‐Specific M3 Guidance
3.1. Autodesk Revit M3 Guidance
1. As the project is constructed, verify that the appropriate UniFormat values are assigned to all content using:
A. Schedules to assign and report on Assembly Code
B. Filters of Views to help communicate and visualize both for compliance views as well as working views throughout the project's progress.
The following platform specific instructions are provided to demonstrate the application of M3
Page 4 of 22 Tab 1. Instructions
Exhibit B-10
5. References
OmniClass
Copyright © 2015 OCCS Development Committee Secretariat
Table 21 Pre-Consensus Approved Draft 2011-02-11 http://omniclass.org/
UniFormat 2010
MasterFormat 2010
MasterFormat ™ is produced jointly by the Construction Specifications Institute (CSI) and Construction Specifications Canada (CSC). U.S. copyright is held by CSI and Canadian copyright by CSC. All Rights Reserved. For more information on MasterFormat , visit www.MasterFormat.com.
UniFormat ™ is produced jointly by the Construction Specifications Institute (CSI) and Construction Specifications Canada (CSC). U.S. copyright is held by CSI and Canadian copyright by CSC. All Rights Reserved. For more information on UniFormat , visit www.csinet.org/uniformat.
Page 5 of 22 Tab 1. Instructions
Exhibit B-10
Level 01/02 Modeling Requirements
Level 1 A SUBSTRUCTURE:
All Substructure elements, with necessary intelligence to produce plans, sections, elevations and schedules; including a depiction of expansion/construction joints.
Level 2 A40 SLABS‐ON‐GRADE:
Slabs‐On‐Grade shall be depicted with all necessary recesses, curbs, pads, slopes, closure pours, and major penetrations depicted. Slabs shall be developed in the Structural Model and then referenced by the Architectural Model.
Level 1 B SHELL:
All Shell elements, with necessary intelligence to produce plans, sections elevations, and schedules; including a depiction of expansion/construction joints.
Level 2 B10 SUPERSTRUCTURE:
All columns, primary and secondary framing members, and bracing for the roof and floor systems (including decks), including all necessary intelligence to produce structural framing plans, related building/wall sections, and schedules. Floor Decks and Slabs for Superstructure shall be developed in the Structural Model and then referenced by the Architectural Model.
Level 2 B20 EXTERIOR VERTICAL ENCLOSURES:
Exterior Vertical Enclosures shall be depicted to the exact height, length, width and ratings
(thermal, acoustic, fire) to properly reflect element types. Exterior Windows, Doors and Grilles, Louvers and Vents, Hardware Sets using BHMA designations and Wall Appurtenances shall be depicted to represent their actual size, type and location with the necessary intelligence to produce schedules.
Level 1 C INTERIORS:
The Interiors Model may vary in level of detail for individual elements. All Interior elements shall be depicted exact height, length, width and ratings (thermal, acoustic, fire) to properly reflect element types, with necessary intelligence to produce plans, sections and elevations; including a depiction of expansion/construction joints.
Level 2 C10 INTERIOR WINDOWS, DOORS, LOUVERS AND VENTS, INTERIOR SPECIALTIES:
Interior Finishes shall be included in the Facility Data of the host element with the necessary intelligence to produce schedules where applicable. Interior Windows, Doors and Grilles, Louvers and Vents, Hardware Sets using BHMA designations and Wall Appurtenances shall be depicted to represent their actual size, type and location with the necessary intelligence to produce schedules.
Level 2 C20 INTERIOR FINISHES:
Interior Finishes shall be included in the Facility Data of the host element with the necessary intelligence to produce schedules.
Level 1 D SERVICES:
All necessary Services elements including all major openings and penetrations, cable trays, cable bundles and pipe grouping (1‐1/2” Ø and larger) shall be depicted with necessary intelligence to produce plans, sections, elevations and schedules where applicable. All clearances and insulation shall be accounted for in the model for use in interference management and maintenance access requirements. Nonpermanent items are not required to be modeled or contain facility data.
Page 6 of 22 Tab 2. Modeling Requirements
Exhibit B-10
Level 2 D20 PLUMBING:
All Plumbing Elements including plumbing piping and fixture layouts, floor and area drains, and related equipment, including necessary intelligence to produce riser diagrams, and schedules where applicable. Small diameter (less than 1‐1/2” NPS) field‐routed piping is not required to be depicted in the Model. All gravity and insulated piping shall be modeled.
Level 2 D30 HEATING, VENTILATION, AND AIR CONDITIONING (HVAC):
All Heating, Ventilation, and Air Conditioning (HVAC) elements including piping, fixture layouts and related equipment with necessary intelligence to produce riser diagrams, and schedules where applicable. Small diameter (less than 1‐1/2” NPS) field‐routed piping is not required to be depicted in the Model. All gravity and insulated piping shall be modeled.
Level 2 D40 FIRE PROTECTION:
All Fire Protection elements including all piping, valves, and seismic bracing shall be modeled with necessary intelligence to produce plans, elevations, building/wall sections, riser diagrams, and schedules where applicable.
Level 2 D50 ELECTRICAL:
All Electrical elements including conduit, fixture layouts and related equipment (including power for systems furniture) with necessary intelligence to produce schedules where applicable. Small diameter (less than 1‐1/2” Ø) field‐routed conduit is not required to be depicted in the Model.
Level 2 D60 COMMUNICATIONS:
All existing and new Communications elements, both above ground and underground, with necessary intelligence to produce schedules where applicable. Small diameter (less than 1‐1/2”
Ø) field‐routed conduit is not required to be depicted in the Model.
Level 2 D70 ELECTRONIC SAFETY AND SECURITY:
All Electronic Safety and Security elements with necessary intelligence to produce schedules.
Small diameter (less than 1‐1/2” Ø) field‐routed conduit is not required to be depicted in the
Model.
Level 2 D80 INTEGRATED AUTOMATION:
All Integrated Automation elements with necessary intelligence to produce schedules. Small diameter (less than 1‐1/2” Ø) field‐routed conduit is not required to be depicted in the Model.
Level 1 E EQUIPMENT AND FURNISHINGS:
All Equipment and Furnishings elements shall be depicted with necessary intelligence to produce plans, sections, elevations and schedules, indicating the configuration, materials, finishes, mechanical, and electrical requirements. Representation of Movable Equipment and
Furnishing elements shall be 2D with Facility Data. Contractor shall provide a minimal number of 3D representations as examples. Examples of Movable Equipment and Furnishings include, but are not limited to, desks, desktop printer, desktop computer, furniture systems, seating, tables, and office storage.
Level 2 E10 EQUIPMENT:
Equipment that make use of electrical, data or other features shall include the necessary intelligence to produce coordinated documents, data, and schedules where applicable.
Level 2 E20 FURNISHINGS:
Fixed Furnishings that make use of electrical, data or other features shall include the necessary intelligence to produce coordinated documents, data, and schedules where applicable.
Page 7 of 22 Tab 2. Modeling Requirements
Exhibit B-10
Level 1 F SPECIAL CONSTRUCTION AND DEMOLITION:
All Special Construction and Demolition elements shall be depicted with necessary intelligence to produce plans, sections and elevations.
Level 1 G SITEWORK:
All Sitework (DTM) elements shall be depicted with necessary intelligence to produce Project site, topographical plans, cross sections and profiles. All clearances shall be accounted for in the model for use in interference management and maintenance access requirements.
Level 2 G30 LIQUID AND GAS SITE UTILITIES:
All Liquid and Gas Site Utilities elements with necessary intelligence to produce schedules where applicable. Small diameter (less than 1‐1/2” Ø) field‐routed piping and conduit is not required to be depicted in the Model.
Level 2 G40 ELECTRICAL SITE IMPROVEMENTS:
All Electrical Site Improvements including all lighting fixtures, relevant existing and proposed support utility lines and equipment with necessary intelligence to produce details and schedules where applicable.
Level 2 G40 ELECTRICAL SITE IMPROVEMENTS:
All Electrical Site Improvements including all lighting fixtures, relevant existing and proposed support utility lines and equipment with necessary intelligence to produce details and schedules where applicable.
Page 8 of 22 Tab 2. Modeling Requirements
Exhibit B-10
DESIGN MODEL
DID AND CDS
DOCUMENTS)
RECORD
MODEL
(AS‐BUILTS)
Level Element ID
OmniClass
ID
UniFormat
ID MasterFormat ID
Included in Facility or Site?
LOD
GRADE
(CD)
GRADE
(AB)
Primary Discipline
(Lessor design and construction team may identify discipline specific areas of content)
Notes
Level 1 SUBSTRUCTURE 21‐01 00 00 A NO ● ● ●
Level 2 FOUNDATIONS 21‐01 10 A10 Yes ● ● ●
Level 3 Standard Foundations 21‐01 10 A1010 Yes ● ● ●
Level 4 Wall Foundations 21‐01 10 10 A1010.10 Yes 200 C C+
Level 4 Column Foundations 21‐01 10 10 10 A1010.30 Yes 300 A A+
Level 4 Standard Foundation Supplementary
Components 21‐01 10 10 30 A1010.90 Yes 200 C C+
Level 3 Special Foundations 21‐01 10 20 A1020 31 60 00 NO ● ● ●
Level 4 Driven Piles 21‐01 10 20 10 A1020.10 31 62 00 NO N/A N/A N/A
Level 4 Bored Piles 21‐01 10 20 15 A1020.15 31 63 00 NO N/A N/A N/A
Level 4 Caissons 21‐01 10 20 20 A1020.20 31 64 00 NO N/A N/A N/A
Level 4 Special Foundation Walls 21‐01 10 20 30 A1020.30 31 66 16 NO N/A N/A N/A
Level 4 Foundation Anchors 21‐01 10 20 40 A1020.40 31 68 00 NO N/A N/A N/A
Level 4 Underpinning 21‐01 10 20 50 A1020.50 31 48 00 NO N/A N/A N/A
Level 4 Raft Foundations 21‐01 10 20 60 A1020.60 03 71 00 NO N/A N/A N/A
Level 4 Pile Caps 21‐01 10 20 70 A1020.70 NO N/A N/A N/A
Level 4 Grade Beams 21‐01 10 20 80 A1020.80 NO N/A N/A N/A
Level 2 SUBGRADE ENCLOSURES 21‐01 20 A20 Yes ● ● ●
Level 3 Walls for Subgrade Enclosures 21‐01 20 10 A2010 Yes ● ● ●
Level 4 Subgrade Enclosure Wall Construction 21‐01 20 10 10 A2010.10 Yes 300 A A+
Level 4 Subgrade Enclosure Wall Interior Skin 21‐01 20 10 20 A2010.20 Yes 300 A A+
Level 4 Subgrade Enclosure Wall Supplementary 21‐01 20 10 90 A2010.90 Yes 200 C C+
Level 2 SLABS ON GRADE 21‐01 40 A40 Yes ● ● ●
Level 3 Standard Slabs‐on‐Grade 21‐01 40 10 A4010 Yes 300 A A+
Level 3 Structural Slabs‐on‐Grade 21‐01 40 20 A4020 Yes 300 A A+
Level 3 Slab Trenches 21‐01 40 30 A4030 Yes 300 A A+
Level 3 Pits and Bases 21‐01 40 40 A4040 Yes 300 A A+
Level 3 Slab‐On‐Grade Supplementary Components 21‐01 40 90 A4090 Yes ● ● ●
Level 4 Perimeter Insulation 21‐01 40 90 10 A4090.10 07 21 00 Yes 100 C C+
Level 4 Vapor Retarder 21‐01 40 90 20 A4090.20 07 26 00 Yes 100 C C+
Level 4 Waterproofing 21‐01 40 90 30 A4090.30 07 10 00 Yes 100 C C+
Level 4 Mud Slab 21‐01 40 90 50 A4090.50 03 30 00 Yes 100 C C+
Level 4 Subbase Layer 21‐01 40 90 60 A4090.60 31 23 23 Yes 100 C C+
Level 2 WATER AND GAS MITIGATION 21‐01 60 A60 Yes ● ● ●
Level 3 Building Subdrainage 21‐01 60 10 A6010 33 46 00 Yes ● ● ●
Level 4 Foundation Drainage 21‐01 60 10 10 A6010.10 33 46 13 Yes 100 C C+
Level 4 Underslab Drainage 21‐01 60 10 20 A6010.20 33 46 19 Yes 100 C C+
Level 3 Off‐Gassing Mitigation 21‐01 60 20 A6020 31 21 00 Yes ● ● ●
Level 4 Radon Mitigation 21‐01 60 20 10 A6020.10 31 21 13 Yes 100 C C+
Level 4 Methane Mitigation 21‐01 60 20 50 A6020.50 31 21 16 Yes 100 C C+
Level 2 SUBSTRUCTURE RELATED ACTIVITIES 21‐01 90 A90 NO ● ● ●
Level 3 Substructure Excavation 21‐01 90 10 A9010 31 23 16 NO ● ● ●
Level 4 Backfill and Compaction 21‐01 90 10 10 A9010.10 31 23 23 NO N/A N/A N/A
Level 3 Construction Dewatering 21‐01 90 20 A9020 31 23 19 NO N/A N/A N/A
Level 3 Excavation Support 21‐01 90 30 A9030 31 50 00 NO ● ● ●
Level 4 Anchor Tiebacks 21‐01 90 30 10 A9030.10 31 51 00 NO N/A N/A N/A
Level 4 Cofferdams 21‐01 90 30 20 A9030.20 31 52 00 NO N/A N/A N/A
Level 4 Cribbing and Walers 21‐01 90 30 40 A9030.40 31 53 00 NO N/A N/A N/A
Level 4 Ground Freezing 21‐01 90 30 60 A9030.60 31 54 00 NO N/A N/A N/A
Level 4 Slurry Walls 21‐01 90 30 70 A9030.70 31 56 00 NO N/A N/A N/A
Level 3 Soil Treatment 21‐01 90 40 A9040 31 31 00 NO N/A N/A N/A
Page 9 of 22 Tab 3. Scope‐LOD‐Grade
Exhibit B-10
(DID AND CDS
DOCUMENTS)
RECORD
MODEL
(AS‐BUILTS)
Level Element ID
OmniClass
ID
UniFormat
ID MasterFormat ID
Included in Facility or Site?
LOD
GRADE
(CD)
GRADE
(AB)
Notes
Level 1 SHELL 21‐02 00 00 B Yes ● ● ●
Level 2 SUPERSTRUCTURE 21‐02 10 B10 Yes ● ● ●
Level 3 Floor Construction 21‐02 10 10 B1010 Yes ● ● ●
Level 4 Floor Structural Frame 21‐02 10 10 10 B1010.10 Yes 300 A A+
Level 4 Floor decks, slabs and topping 21‐02 10 10 20 B1010.20 Yes 300 A A+
Level 4 Balcony Floor Construction 21‐02 10 10 30 B1010.30 Yes 300 A A+
Level 4 Mezzanine Floor Construction 21‐02 10 10 40 B1010.40 Yes 300 A A+
Level 4 Ramps 21‐02 10 10 50 B1010.50 Yes 300 A A+
Level 4 Floor Construction Supplementary Components 21‐02 10 10 90 B1010.90 Yes 200 C C+
Level 3 Roof Construction 21‐02 10 20 B1020 Yes ● ● ●
Level 4 Roof Structural Frame 21‐02 10 20 10 B1020.10 Yes 300 A A+
Level 4 Roof decks, slabs and sheathing 21‐02 10 20 20 B1020.20 Yes 300 A A+
Level 4 Canopy Construction 21‐02 10 20 30 B1020.30 Yes 300 A A+
Level 4 Roof Construction Supplementary Components 21‐02 10 20 90 B1020.90 Yes 200 C C+
Level 3 Stairs 21‐02 10 80 B1080 Yes ● ● ●
Level 4 Stair Construction 21‐02 10 80 10 B1080.10 Yes 200 C C+
Level 4 Stair Soffits 21‐02 10 80 30 B1080.30 Yes 200 C C+
Level 4 Stair Railings 21‐02 10 80 50 B1080.50 Yes 200 C C+
Level 4 Fire Escapes 21‐02 10 80 60 B1080.60 05 51 23 Yes 200 C C+
Level 4 Metal Walkways 21‐02 10 80 70 B1080.70 05 51 36 Yes 200 C C+
Level 4 Ladders 21‐02 10 80 80 B1080.80 05 51 23 Yes 200 C C+
Level 2 EXTERIOR VERTICAL ENCLOSURES 21‐02 20 B20 Yes ● ● ●
Level 3 Exterior Walls 21‐02 20 10 B2010 Yes ● ● ●
Level 4 Exterior Wall Veneer 21‐02 20 10 10 B2010.10 Yes 200 C C+
Level 4 Exterior Wall Construction 21‐02 20 10 20 B2010.20 Yes 200 C C+
Level 4 Exterior Wall Interior Skin 21‐02 20 10 30 B2010.30 Yes 200 C C+
Level 4 Fabricated Exterior Wall Assemblies 21‐02 20 10 40 B2010.40 Yes 200 C C+
Level 4 Parapets 21‐02 20 10 50 B2010.50 Yes 200 C C+
Level 4 Equipment Screens 21‐02 20 10 60 B2010.60 Yes 200 C C+
Level 4 Exterior Wall Supplementary Components 21‐02 20 10 80 B2010.80 Yes 100 C C+
Level 4 Exterior Wall Opening Supplementary 21‐02 20 10 90 B2010.90 Yes 100 C C+
Level 3 Exterior Windows 21‐02 20 20 B2020 08 50 00 Yes ● ● ●
Level 4 Exterior Operating Windows 21‐02 20 20 10 B2020.10 08 50 00 NO N/A N/A N/A
Level 4 Exterior Fixed Windows 21‐02 20 20 20 B2020.20 08 50 00 Yes 300 A A+
Level 4 Exterior Window Wall 21‐02 20 20 30 B2020.30 Yes 300 A A+
Level 4 Exterior Special Function Windows 21‐02 20 20 50 B2020.50 08 56 00 Yes 300 A A+
Level 3 Exterior Doors and Grilles 21‐02 20 50 B2050 Yes ● ● ●
Level 4 Exterior Entrance Doors 21‐02 20 50 10 B2050.10 08 42 00 Yes 300 A A+
Level 4 Exterior Utility Doors 21‐02 20 50 20 B2050.20 08 10 00 Yes 300 A A+
Level 4 Exterior Oversize Doors 21‐02 20 50 30 B2050.30 Yes 300 A A+
Level 4 Exterior Special Function Doors 21‐02 20 50 40 B2050.40 08 30 00 Yes 300 A A+
Level 4 Exterior Grilles 21‐02 20 50 60 B2050.60 Yes 300 A A+
Level 4 Exterior Gates 21‐02 20 50 70 B2050.70 Yes 300 A A+
Level 4 Exterior Door Supplementary Components 21‐02 20 50 90 B2050.90 Yes 200 C C+
Level 3 Exterior Louvers and Vents 21‐02 20 70 B2070 08 90 00 Yes ● ● ●
Level 4 Exterior Louvers 21‐02 20 70 10 B2070.10 08 91 00 Yes 300 A A+
Level 4 Exterior Vents 21‐02 20 70 50 B2070.50 08 95 00 Yes 300 A A+
Level 3 Exterior Wall Appurtenances 21‐02 20 80 B2080 Yes ● ● ●
Level 4 Exterior Fixed Grilles and Screens 21‐02 20 80 10 B2080.10 10 82 13 Yes 300 A A+
Level 4 Exterior Opening Protection Devices 21‐02 20 80 30 B2080.30 Yes 300 C C+
Level 4 Exterior Balcony Walls and Railings 21‐02 20 80 50 B2080.50 05 52 00 Yes 300 A A+
Level 4 Exterior Fabrications 21‐02 20 80 70 B2080.70 Yes 300 A A+
Level 4 Bird Control Devices 21‐02 20 80 80 B2080.80 10 81 13 Yes 100 C C+
Page 10 of 22 Tab 3. Scope‐LOD‐Grade
Primary Discipline
(Lessor design and construction team may identify discipline specific areas of content)
Exhibit B-10
DID & CD
DOCUMENTS)
RECORD
MODEL
(AS‐BUILTS)
Level Element ID
OmniClass
ID
UniFormat
ID MasterFormat ID
Included in Facility or Site?
LOD
GRADE
(CD)
GRADE
(AB)
Notes
Level 3 Exterior Wall Specialties 21‐02 20 90 B2090 10 74 00 Yes 100 C C+
Level 2 EXTERIOR HORIZONTAL ENCLOSURES 21‐02 30 B30 Yes ● ● ●
Level 3 Roofing 21‐02 30 10 B3010 Yes ● ● ●
Level 4 Steep Slope Roofing 21‐02 30 10 10 B3010.10 07 30 00 Yes 300 A A+
Level 4 Low‐Slope Roofing 21‐02 30 10 50 B3010.50 Yes 300 A A+
Level 4 Canopy Roofing 21‐02 30 10 70 B3010.70 Yes 300 A A+
Level 4 Roofing Supplementary Components 21‐02 30 10 90 B3010.90 Yes 200 C C+
Level 3 Roof Appurtenances 21‐02 30 20 B3020 Yes ● ● ●
Level 4 Roof Accessories 21‐02 30 20 10 B3020.10 07 72 00 Yes 200 B B+
Level 4 Roof Specialties 21‐02 30 20 30 B3020.30 10 74 00 Yes 200 B B+
Level 4 Rainwater Management 21‐02 30 20 70 B3020.70 ND Yes 200 B B+
Level 3 Traffic Bearing Horizontal Enclosures 21‐02 30 40 B3040 NO ● ● ●
Level 4 Traffic Bearing Coatings 21‐02 30 40 10 B3040.10 07 18 00 NO N/A N/A N/A
Level 4 Horizontal Waterproofing Membrane 21‐02 30 40 30 B3040.30 07 10 00 NO N/A N/A N/A
Level 4 Wear Surfaces 21‐02 30 40 50 B3040.50 NO N/A N/A N/A
Level 4 Horizontal Enclosure Supplementary 21‐02 30 40 90 B3040.90 NO N/A N/A N/A
Level 3 Horizontal Openings 21‐02 30 60 B3060 Yes ● ● ●
Level 4 Roof Windows and Skylights 21‐02 30 60 10 B3060.10 08 60 00 Yes 200 C C
Level 4 Vents and Hatches 21‐02 30 60 50 B3060.50 Yes 200 C C
Level 4 Horizontal Opening Supplementary Components 21‐02 30 60 90 B3060.90 Yes 200 C C
Level 3 Overhead Exterior Enclosures 21‐02 30 80 B3080 Yes ● ● ●
Level 4 Exterior Ceilings 21‐02 30 80 10 B3080.10 Yes 200 C C
Level 4 Exterior Soffits 21‐02 30 80 20 B3080.20 Yes 200 C C
Level 4 Exterior Bulkheads 21‐02 30 80 30 B3080.30 Yes 200 C C
Level 1 INTERIORS 21‐03 00 00 C Yes ● ● ●
Level 2 INTERIOR CONSTRUCTION 21‐03 10 C10 Yes ● ● ●
Level 3 Interior Partitions 21‐03 10 10 C1010 10 22 00 Yes ● ● ●
Level 4 Interior Fixed Partitions 21‐03 10 10 10 C1010.10 Yes 350 A A+
Level 4 Interior Glazed Partitions 21‐03 10 10 20 C1010.20 Yes 350 A A+
Level 4 Interior Demountable Partitions 21‐03 10 10 40 C1010.40 10 22 19 Yes 350 A A+
Level 4 Interior Operable Partitions 21‐03 10 10 50 C1010.50 Yes 350 A A+
Level 4 Interior Screens 21‐03 10 10 70 C1010.70 Yes 350 A A+
Level 4 Interior Partition Supplementary Components 21‐03 10 10 90 C1010.90 Yes 200 C C+
Level 3 Interior Windows (a.k.a borrowed lites) 21‐03 10 20 C1020 08 50 00 Yes ● ● ●
Level 4 Interior Operating Windows 21‐03 10 20 10 C1020.10 08 50 00 Yes 350 A A+
Level 4 Interior Fixed Windows 21‐03 10 20 20 C1020.20 08 50 00 Yes 350 A A+
Level 4 Interior Special Function Windows 21‐03 10 20 50 C1020.50 08 50 00 Yes 350 A A+
Level 4 Interior Window Supplementary Components 21‐03 10 20 90 C1020.90 08 50 00 Yes 300 C C+
Level 3 Interior Doors 21‐03 10 30 C1030 08 10 00 Yes ● ● ●
Level 4 Interior Swinging Doors 21‐03 10 30 10 C1030.10 08 10 00 Yes 350 A A+
Level 4 Interior Entrance Doors 21‐03 10 30 20 C1030.20 08 10 00 Yes 350 A A+
Level 4 Interior Sliding Doors 21‐03 10 30 25 C1030.25 08 42 00 Yes 350 A A+
Level 4 Interior Folding Doors 21‐03 10 30 30 C1030.30 08 11 73 Yes 350 A A+
Level 4 Interior Coiling Doors 21‐03 10 30 40 C1030.40 08 35 13 Yes 350 A A+
Level 4 Interior Panel Doors 21‐03 10 30 50 C1030.50 08 33 00 Yes 350 A A+
Level 4 Interior Special Function Doors 21‐03 10 30 70 C1030.70 08 36 00 Yes 350 A A+
Level 4 Interior Access Doors and Panels 21‐03 10 30 80 C1030.80 08 30 00 Yes 350 A A+
Level 4 Interior Door Supplementary Components 21‐03 10 30 90 C1030.90 08 31 00 Yes 200 C C+
Level 3 Interior Grilles and Gates 21‐03 10 40 C1040 Yes ● ● ●
Level 4 Interior Grilles 21‐03 10 40 10 C1040.10 Yes 300 A A+
Level 4 Interior Gates 21‐03 10 40 50 C1040.50 Yes 350 A A+
Page 11 of 22 Tab 3. Scope‐LOD‐Grade
Primary Discipline
(Lessor design and construction team may identify discipline specific areas of content)
Exhibit B-10
(DID & CD
DOCUMENTS)
RECORD
MODEL
(AS‐BUILTS)
Level Element ID
OmniClass
ID
UniFormat
ID MasterFormat ID
Included in Facility or Site?
LOD
GRADE
(CD)
GRADE
(AB)
Notes
Level 3 Raised Floor Construction 21‐03 10 60 C1060 Yes ● ● ●
Level 4 Access Flooring 21‐03 10 60 10 C1060.10 09 69 00 Yes 350 A A+
Level 4 Platform/Stage Floors 21‐03 10 60 30 C1060.30 Yes 300 A A+
Level 3 Suspended Ceiling Construction 21‐03 10 70 C1070 Yes ● ● ●
Level 4 Acoustical Suspended Ceilings 21‐03 10 70 10 C1070.10 09 51 00 Yes 350 A A+
Level 4 Suspended Plaster and Gypsum Board Ceilings 21‐03 10 70 20 C1070.20 Yes 300 A A+
Level 4 Specialty Suspended Ceilings 21‐03 10 70 50 C1070.50 09 54 00 Yes 200 A A+
Level 4 Special Function Suspended Ceilings 21‐03 10 70 70 C1070.70 09 57 00 Yes 200 A A+
Level 4 Ceiling Suspension Components 21‐03 10 70 90 C1070.90 Yes 100 C C+
Level 3 Interior Specialties 21‐03 10 90 C1090 Yes ● ● ●
Level 4 Interior Railings and Handrails 21‐03 10 90 10 C1090.10 Yes 300 A A+
Level 4 Interior Louvers 21‐03 10 90 15 C1090.15 08 91 00 Yes 300 A A+
Level 4 Information Specialties 21‐03 10 90 20 C1090.20 10 10 00 Yes 200 B B+
Level 4 Compartments and Cubicles 21‐03 10 90 25 C1090.25 10 21 00 Yes 200 C C+
Level 4 Service Walls 21‐03 10 90 30 C1090.30 10 25 00 Yes 300 A A+
Level 4 Wall and Door Protection 21‐03 10 90 35 C1090.35 10 26 00 Yes 200 C C+
Level 4 Toilet, Bath, and Laundry Accessories 21‐03 10 90 40 C1090.40 10 28 00 Yes 200 A A+
Level 4 Interior Gas Lighting 21‐03 10 90 45 C1090.45 10 84 16 NO N/A N/A N/A
Level 4 Fireplaces and stoves 21‐03 10 90 50 C1090.50 10 30 00 NO N/A N/A N/A
Level 4 Safety Specialties 21‐03 10 90 60 C1090.60 10 40 00 Yes 200 A A+
Level 4 Storage Specialties 21‐03 10 90 70 C1090.70 10 50 00 Yes 200 A A+
Level 4 Other Interior Specialties 21‐03 10 90 90 C1090.90 10 80 00 Yes 200 C C+
Level 2 INTERIOR FINISHES 21‐03 20 C20 Yes ● ● ●
Level 3 Wall Finishes 21‐03 20 10 C2010 09 70 00 Yes ● ● ●
Level 4 Tile Wall Finish 21‐03 20 10 10 C2010.10 09 30 00 Yes 200 B B+
Level 4 Wall Paneling 21‐03 20 10 20 C2010.20 Yes 200 B B+
Level 4 Wall Coverings 21‐03 20 10 30 C2010.30 09 72 00 Yes 200 B B+
Level 4 Wall Carpeting 21‐03 20 10 35 C2010.35 09 73 00 Yes 200 B B+
Level 4 Stone Facing 21‐03 20 10 50 C2010.50 09 75 00 Yes 200 B B+
Level 4 Special Wall Surfacing 21‐03 20 10 60 C2010.60 09 77 00 Yes 200 B B+
Level 4 Wall Painting and Coating 21‐03 20 10 70 C2010.70 09 90 00 Yes 200 B B+
Level 4 Acoustical Wall Treatment 21‐03 20 10 80 C2010.80 Yes 100 B B+
Level 4 Wall Finish Supplementary Components 21‐03 20 10 90 C2010.90 Yes 200 C C+
Level 3 Interior Fabrications 21‐03 20 20 C2020 Yes 100 B B+
Level 3 Flooring 21‐03 20 30 C2030 09 60 00 Yes ● ● ●
Level 4 Flooring Treatment 21‐03 20 30 10 C2030.10 09 61 00 Yes 200 B B+
Level 4 Tile Flooring 21‐03 20 30 20 C2030.20 09 30 00 Yes 200 B B+
Level 4 Specialty Flooring 21‐03 20 30 30 C2030.30 09 62 00 Yes 200 B B+
Level 4 Masonry Flooring 21‐03 20 30 40 C2030.40 09 63 00 Yes 200 B B+
Level 4 Wood Flooring 21‐03 20 30 45 C2030.45 09 64 00 Yes 200 B B+
Level 4 Resilient Flooring 21‐03 20 30 50 C2030.50 09 65 00 Yes 200 B B+
Level 4 Terrazzo Flooring 21‐03 20 30 60 C2030.60 09 66 00 Yes 200 B B+
Level 4 Fluid‐Applied Flooring 21‐03 20 30 70 C2030.70 09 67 00 Yes 200 B B+
Level 4 Carpeting 21‐03 20 30 75 C2030.75 09 68 00 Yes 200 B B+
Level 4 Athletic Flooring 21‐03 20 30 80 C2030.80 Yes 200 B B+
Level 4 Entrance Flooring 21‐03 20 30 85 C2030.85 Yes 200 B B+
Level 4 Flooring Supplementary Components 21‐03 20 30 90 C2030.90 Yes 200 C C+
Level 3 Stair Finishes 21‐03 20 40 C2040 Yes ● ● ●
Level 4 Tile Stair Finish 21‐03 20 40 20 C2040.20 09 30 00 Yes 100 B B+
Level 4 Masonry Stair Finish 21‐03 20 40 40 C2040.40 09 63 00 Yes 100 B B+
Page 12 of 22 Tab 3. Scope‐LOD‐Grade
Primary Discipline
(Lessor design and construction team may identify discipline specific areas of content)
Exhibit B-10
(DID & CD
DOCUMENTS)
RECORD
MODEL
(AS‐BUILTS)
Level Element ID
OmniClass
ID
UniFormat
ID MasterFormat ID
Included in Facility or Site?
LOD
GRADE
(CD)
GRADE
(AB)
Notes
Level 4 Wood Stair Finish 21‐03 20 40 45 C2040.45 09 64 00 Yes 100 B B+
Level 4 Resilient Stair Finish 21‐03 20 40 50 C2040.50 09 65 00 Yes 100 B B+
Level 4 Terrazzo Stair Finish 21‐03 20 40 60 C2040.60 09 66 00 Yes 100 B B+
Level 4 Carpeted Stair Finish 21‐03 20 40 75 C2040.75 09 68 00 Yes 100 B B+
Level 3 Ceiling Finishes 21‐03 20 50 C2050 09 50 00 Yes ● ● ●
Level 4 Plaster and Gypsum Board Finish 21‐03 20 50 10 C2050.10 09 20 00 Yes 200 B B+
Level 4 Ceiling Paneling 21‐03 20 50 20 C2050.20 Yes 200 B B+
Level 4 Ceiling Painting and Coating 21‐03 20 50 70 C2050.70 09 90 00 Yes 100 B B+
Level 4 Acoustical Ceiling Treatment 21‐03 20 50 80 C2050.80 Yes 200 B B+
Level 4 Ceiling Finish Supplementary Components 21‐03 20 50 90 C2050.90 Yes 200 C C+
Level 1 SERVICES 21‐04 00 00 D Yes ● ● ●
Level 2 CONVEYING 21‐04 10 D10 14 00 00 Yes ● ● ●
Level 3 Vertical Conveying Systems 21‐04 10 10 D1010 Yes ● ● ●
Level 4 Elevators 21‐04 10 10 10 D1010.10 14 20 00 Yes 200 A A+
Level 4 Lifts 21‐04 10 10 20 D1010.20 14 40 00 Yes 200 A A+
Level 4 Escalators 21‐04 10 10 30 D1010.30 14 31 00 Yes 200 A A+
Level 4 Dumbwaiters 21‐04 10 10 50 D1010.50 14 10 00 Yes 200 A A+
Level 4 Moving Ramps 21‐04 10 10 60 D1010.60 14 33 00 Yes 200 A A+
Level 3 Horizontal Conveying Systems 21‐04 10 30 D1030 Yes ● ● ●
Level 4 Moving Walks 21‐04 10 30 10 D1030.10 14 32 00 Yes 200 A A+
Level 4 Turntables 21‐04 10 30 30 D1030.30 14 70 00 Yes 200 A A+
Level 4 Passenger Loading Bridges 21‐04 10 30 50 D1030.50 34 77 13 Yes 200 A A+
Level 4 People Movers 21‐04 10 30 70 D1030.70 Yes 200 A A+
Level 3 Material Handling 21‐04 10 50 D1050 NO ● ● ●
Level 4 Cranes 21‐04 10 50 10 D1050.10 41 22 13 NO N/A N/A N/A
Level 4 Hoists 21‐04 10 50 20 D1050.20 41 22 23 NO N/A N/A N/A
Level 4 Derricks 21‐04 10 50 30 D1050.30 41 22 33 NO N/A N/A N/A
Level 4 Conveyors 21‐04 10 50 40 D1050.40 41 21 00 NO N/A N/A N/A
Level 4 Baggage Handling Equipment 21‐04 10 50 50 D1050.50 34 77 16 NO N/A N/A N/A
Level 4 Chutes 21‐04 10 50 60 D1050.60 14 91 00 NO N/A N/A N/A
Level 4 Pneumatic Tube Systems 21‐04 10 50 70 D1050.70 14 92 00 NO N/A N/A N/A
Level 3 Operable Access Systems 21‐04 10 80 D1080 NO ● ● ●
Level 4 Suspended Scaffolding 21‐04 10 80 10 D1080.10 14 81 00 NO N/A N/A N/A
Level 4 Rope Climbers 21‐04 10 80 20 D1080.20 14 82 00 NO N/A N/A N/A
Level 4 Elevating Platforms 21‐04 10 80 30 D1080.30 14 83 00 NO N/A N/A N/A
Level 4 Powered Scaffolding 21‐04 10 80 40 D1080.40 14 84 00 NO N/A N/A N/A
Level 4 Building Envelope Access 21‐04 10 80 50 D1080.50 NO N/A N/A N/A
Level 2 PLUMBING 21‐04 20 D20 22 00 00 Yes ● ● ●
Level 3 Domestic Water Distribution 21‐04 20 10 D2010 22 11 00 Yes ● ● ●
Level 4 Facility Potable‐Water Storage Tanks 21‐04 20 10 10 D2010.10 22 12 00 Yes 300 A A+
Level 4 Domestic Water Equipment 21‐04 20 10 20 D2010.20 Yes 300 A A+
Level 4 Domestic Water Piping 21‐04 20 10 40 D2010.40 22 11 16 Yes 300 A A+ 1/2" Diameter or larger shall be modeled Level 4 Plumbing Fixtures 21‐04 20 10 60 D2010.60 22 40 00 Yes 300 A A+
Level 4 Domestic Water Distribution Supplementary
Components 21‐04 20 10 90 D2010.90 Yes 100 A A+
Level 3 Sanitary Drainage 21‐04 20 20 D2020 22 13 00 Yes ● ● ●
Level 4 Sanitary Sewerage Equipment 21‐04 20 20 10 D2020.10 Yes 300 A A+
Level 4 Sanitary Sewerage Piping 21‐04 20 20 30 D2020.30 Yes 300 A A+ 1‐1/2" Diameter or larger shall be modeled
Page 13 of 22 Tab 3. Scope‐LOD‐Grade
Primary Discipline
(Lessor design and construction team may identify discipline specific areas of content)
Exhibit B-10
(DID & CD
DOCUMENTS)
RECORD
MODEL
(AS‐BUILTS)
Level Element ID
OmniClass
ID
UniFormat
ID MasterFormat ID
Included in Facility or Site?
LOD
GRADE
(CD)
GRADE
(AB)
Notes
Level 4 Sanitary Drainage Supplementary Components 21‐04 20 20 90 D2020.90 Yes 100 A A+
Level 3 Building Support Plumbing Systems 21‐04 20 30 D2030 22 14 00 Yes ● ● ●
Level 4 Stormwater Drainage Equipment 21‐04 20 30 10 D2030.10 Yes 300 A A+
Level 4 Stormwater Drainage Piping 21‐04 20 30 20 D2030.20 22 14 13 Yes 300 A A+ 2" Diameter or larger shall be modeled
Level 4 Facility Stormwater Drains 21‐04 20 30 30 D2030.30 22 14 26 Yes 300 A A+ 2" Diameter or larger shall be modeled
Level 4 Gray Water Systems 21‐04 20 30 60 D2030.60 Yes 300 A A+ 2" Diameter or larger shall be modeled
Level 4 Building Support Plumbing System
Supplementary Components 21‐04 20 30 90 D2030.90 Yes 100 A A+
Level 3 General Service Compressed‐Air 21‐04 20 50 D2050 22 15 00 Yes 300 A A+
Level 3 Process Support Plumbing Systems 21‐04 20 60 D2060 NO ● ● ●
Level 4 Compressed‐Air Systems 21‐04 20 60 10 D2060.10 22 61 00 NO N/A N/A N/A
Level 4 Vacuum Systems 21‐04 20 60 20 D2060.20 22 62 00 NO N/A N/A N/A
Level 4 Gas Systems 21‐04 20 60 30 D2060.30 22 63 00 NO N/A N/A N/A
Level 4 Chemical‐Waste Systems 21‐04 20 60 40 D2060.40 22 66 00 NO N/A N/A N/A
Level 4 Processed Water Systems 21‐04 20 60 50 D2060.50 22 67 00 NO N/A N/A N/A
Level 4 Process Support Plumbing System
Supplementary Components
21‐04 20 60 90 D2060.90 NO N/A N/A N/A
Level 2 HVAC 21‐04 30 D30 23 00 00 Yes ● ● ●
Level 3 Facility Fuel Systems 21‐04 30 10 D3010 23 10 00 Yes ● ● ●
Level 4 Fuel Piping 21‐04 30 10 10 D3010.10 23 11 00 Yes 300 A A+
Level 4 Fuel Pumps 21‐04 30 10 30 D3010.30 23 12 00 Yes 300 A A+
Level 4 Fuel Storage Tanks 21‐04 30 10 50 D3010.50 23 13 00 Yes 300 A A+
Level 3 Heating Systems 21‐04 30 20 D3020 Yes ● ● ●
Level 4 Heat Generation 21‐04 30 20 10 D3020.10 Yes 300 A A+
Level 4 Thermal Heat Storage 21‐04 30 20 30 D3020.30 23 71 13 Yes 300 A A+
Level 4 Decentralized Heating Equipment 21‐04 30 20 70 D3020.70 23 80 00 Yes 300 A A+
Level 4 Heating System Supplementary Components 21‐04 30 20 90 D3020.90 Yes 100 A A+
Level 3 Cooling Systems 21‐04 30 30 D3030 Yes ● ● ●
Level 4 Central Cooling 21‐04 30 30 10 D3030.10 23 60 00 Yes 300 A A+
Level 4 Evaporative Air‐Cooling 21‐04 30 30 30 D3030.30 23 76 00 Yes 300 A A+
Level 4 Thermal Cooling Storage 21‐04 30 30 50 D3030.50 23 71 00 Yes 300 A A+
Level 4 Decentralized Cooling 21‐04 30 30 70 D3030.70 23 80 00 Yes 300 A A+
Level 4 Cooling System Supplementary Components 21‐04 30 30 90 D3030.90 Yes 100 A A+
Level 3 Facility HVAC Distribution Systems 21‐04 30 50 D3050 Yes ● ● ●
Level 4 Facility Hydronic Distribution 21‐04 30 50 10 D3050.10 Yes 300 A A+
Level 4 Facility Steam Distribution 21‐04 30 50 30 D3050.30 Yes 300 A A+
Level 4 HVAC Air Distribution 21‐04 30 50 50 D3050.50 Yes 300 A A+
Level 4 Facility Distribution Systems Supplementary
Components 21‐04 30 50 90 D3050.90 Yes 100 A A+
Level 3 Ventilation 21‐04 30 60 D3060 Yes ● ● ●
Level 4 Supply Air 21‐04 30 60 10 D3060.10 Yes 300 A A+
Level 4 Return Air 21‐04 30 60 20 D3060.20 Yes 300 A A+
Level 4 Exhaust Air 21‐04 30 60 30 D3060.30 Yes 300 A A+
Level 4 Outside Air 21‐04 30 60 40 D3060.40 Yes 300 A A+
Level 4 Air‐to‐Air Energy Recovery 21‐04 30 60 60 D3060.60 23 72 00 Yes 300 A A+
Level 4 HVAC Air Cleaning 21‐04 30 60 70 D3060.70 23 40 00 Yes 300 B B+
Level 4 Ventilation Supplementary Components 21‐04 30 60 90 D3060.90 Yes 100 A A+
Level 3 Special Purpose HVAC Systems 21‐04 30 70 D3070 Yes ● ● ●
Level 4 Snow Melting 21‐04 30 70 10 D3070.10 23 83 00 Yes 100 B B+
Level 2 FIRE PROTECTION 21‐04 40 D40 21 00 00 Yes ● ● ●
Page 14 of 22 Tab 3. Scope‐LOD‐Grade
Primary Discipline
(Lessor design and construction team may identify discipline specific areas of content)
Exhibit B-10
(DID & CD
DOCUMENTS)
RECORD
MODEL
(AS‐BUILTS)
Level Element ID
OmniClass
ID
UniFormat
ID MasterFormat ID
Included in Facility or Site?
LOD
GRADE
(CD)
GRADE
(AB)
Notes
Level 3 Fire Suppression 21‐04 40 10 D4010 10 44 00 Yes ● ● ●
Level 4 Water‐Based Fire‐Suppression 21‐04 40 10 10 D4010.10 21 10 00 Yes 300 A A+
Level 4 Fire‐Extinguishing 21‐04 40 10 50 D4010.50 21 20 00 Yes 300 A A+
Level 4 Fire Suppression Supplementary Components 21‐04 40 10 90 D4010.90 Yes 100 A A+
Level 3 Fire Protection Specialties 21‐04 40 30 D4030 26 00 00 Yes ● ● ●
Level 4 Fire Protection Cabinets 21‐04 40 30 10 D4030.10 10 44 13 Yes 200 A A+
Level 4 Fire Extinguishers 21‐04 40 30 30 D4030.30 10 44 16 Yes 200 A A+
Level 4 Breathing Air Replenishment Systems 21‐04 40 30 50 D4030.50 10 44 33 Yes 200 A A+
Level 4 Fire Extinguisher Accessories 21‐04 40 30 70 D4030.70 10 44 43 Yes 200 A A+
Level 2 ELECTRICAL 21‐04 50 D50 Yes ● ● ●
Level 3 Facility Power Generation 21‐04 50 10 D5010 Yes ● ● ●
Level 4 Packaged Generator Assemblies 21‐04 50 10 10 D5010.10 26 32 00 Yes 300 A A+
Level 4 Battery Equipment 21‐04 50 10 20 D5010.20 26 33 00 Yes 300 A A+
Level 4 Photovoltaic Collectors 21‐04 50 10 30 D5010.30 26 31 00 Yes 200 A A+
Level 4 Fuel Cells 21‐04 50 10 40 D5010.40 48 18 00 Yes 200 A A+
Level 4 Power Filtering and Conditioning 21‐04 50 10 60 D5010.60 26 35 00 Yes 200 A A+
Level 4 Transfer Switches 21‐04 50 10 70 D5010.70 26 36 00 Yes 200 A A+
Level 4 Facility Power Generation Supplementary 21‐04 50 10 90 D5010.90 Yes 100 A A+
Level 3 Electrical Service and Distribution 21‐04 50 20 D5020 Yes ● ● ●
Level 4 Electrical Service 21‐04 50 20 10 D5020.10 26 21 00 Yes 200 B B+
Level 4 Power Distribution 21‐04 50 20 30 D5020.30 26 20 00 Yes 200 B B+
Level 4 Facility Grounding 21‐04 50 20 70 D5020.70 26 05 26 Yes 200 B B+
Level 4 Electrical Service and Distribution
Supplementary Components 21‐04 50 20 90 D5020.90 Yes 200 B B+
Level 3 General Purpose Electrical Power 21‐04 50 30 D5030 Yes ● ● ●
Level 4 Branch Wiring System 21‐04 50 30 10 D5030.10 Yes 200 B B+
Level 4 Wiring Devices 21‐04 50 30 50 D5030.50 26 27 26 Yes 200 B B+
Level 4 General Purpose Electrical Power
Supplementary Components 21‐04 50 30 90 D5030.90 Yes 200 B B+
Level 3 Lighting 21‐04 50 40 D5040 26 50 00 Yes ● ● ●
Level 4 Lighting Control 21‐04 50 40 10 D5040.10 26 09 23 Yes 200 B B+
Level 4 Branch Wiring for Lighting 21‐04 50 40 20 D5040.20 Yes 200 B B+
Level 4 Lighting Fixtures 21‐04 50 40 50 D5040.50 26 50 00 Yes 350 A A+
Level 4 Lighting Supplementary Components 21‐04 50 40 90 D5040.90 Yes 200 A A+
Level 3 Miscellaneous Electrical Systems 21‐04 50 80 D5080 Yes ● ● ●
Level 4 Lightning Protection 21‐04 50 80 10 D5080.10 26 41 00 Yes 200 B B+
Level 4 Cathodic Protection 21‐04 50 80 40 D5080.40 26 42 00 Yes 200 A A+
Level 4 Transient Voltage Suppression 21‐04 50 80 70 D5080.70 26 43 00 Yes 200 A A+
Level 4 Miscellaneous Electrical Systems Supplementary
Components 21‐04 50 80 90 D5080.90 Yes 200 A A+
Level 2 COMMUNICATIONS 21‐04 60 D60 27 00 00 Yes ● ● ●
Level 3 Data Communications 21‐04 60 10 D6010 27 20 00 Yes ● ● ●
Level 4 Data Communications Network and Equipment 21‐04 60 10 10 D6010.10 Yes 200 A A+
Level 4 Data Communications Hardware 21‐04 60 10 20 D6010.20 27 22 00 Yes 200 A A+
Level 4 Data Communications Peripheral Data 21‐04 60 10 30 D6010.30 Yes 200 A A+
Level 4 Data Communications Software 21‐04 60 10 50 D6010.50 27 25 00 Yes 200 C C+
Level 4 Data Communication Program and Integration 21‐04 60 10 60 D6010.60 27 26 00 Yes 200 C C+
Level 3 Voice Communications 21‐04 60 20 D6020 27 30 00 Yes ● ● ●
Level 4 Voice Communications Switching and Routing
Equipment 21‐04 60 20 10 D6020.10 27 31 00 Yes 200 A A+
Page 15 of 22 Tab 3. Scope‐LOD‐Grade
Primary Discipline
(Lessor design and construction team may identify discipline specific areas of content)
Exhibit B-10
(DID & CD
DOCUMENTS)
RECORD
MODEL
(AS‐BUILTS)
Level Element ID
OmniClass
ID
UniFormat
ID MasterFormat ID
Included in Facility or Site?
(change to NO if
NOT part of project scope) LOD
GRADE
(CD)
GRADE
(AB)
Notes
Level 4 Voice Communications Terminal Equipment 21‐04 60 20 20 D6020.20 Yes 200 A A+
Level 4 Voice Communications Messaging 21‐04 60 20 30 D6020.30 27 33 00 Yes 200 C C+
Level 4 Call Accounting 21‐04 60 20 40 D6020.40 27 34 00 Yes 200 C C+
Level 4 Call Management 21‐04 60 20 50 D6020.50 27 35 00 Yes 200 C C+
Level 3 Audio‐Video Communication 21‐04 60 30 D6030 27 40 00 Yes ● ● ●
Level 4 Audio‐Video Systems 21‐04 60 30 10 D6030.10 27 41 00 Yes 200 A A+
Level 4 Electronic Digital Systems 21‐04 60 30 50 D6030.50 27 42 00 Yes 200 C C+
Level 3 Distributed Communications and Monitoring 21‐04 60 60 D6060 27 50 00 Yes ● ● ●
Level 4 Distributed Audio‐Video 21‐04 60 60 10 D6060.10 Yes 200 A A+
Level 4 Healthcare Communications and Monitoring 21‐04 60 60 30 D6060.30 27 52 00 NO N/A N/A N/A
Level 4 Distributed Systems 21‐04 60 60 50 D6060.50 27 53 00 Yes 200 A A+
Level 3 Communications Supplementary Components 21‐04 60 90 D6090 Yes ● ● ●
Level 4 Supplementary Components 21‐04 60 90 10 D6090.10 Yes 100 C C+
Level 2 ELECTRONIC SAFETY AND SECURITY 21‐04 70 D70 28 00 00 Yes ● ● ●
Level 3 Access Control and Intrusion Detection 21‐04 70 10 D7010 Yes ● ● ●
Level 4 Access Control 21‐04 70 10 10 D7010.10 Yes 300 A A+
Level 4 Intrusion Detection 21‐04 70 10 50 D7010.50 Yes 300 A A+
Level 3 Electronic Surveillance 21‐04 70 30 D7030 Yes ● ● ●
Level 4 Video Surveillance 21‐04 70 30 10 D7030.10 Yes 300 A A+
Level 4 Electronic Personal Protection 21‐04 70 30 50 D7030.50 Yes 300 A A+
Level 3 Detection and Alarm 21‐04 70 50 D7050 Yes ● ● ●
Level 4 Fire Detection and Alarm 21‐04 70 50 10 D7050.10 Yes 300 A A+
Level 4 Radiation Detection and Alarm 21‐04 70 50 20 D7050.20 Yes 300 A A+
Level 4 Fuel‐Gas Detection and Alarm 21‐04 70 50 30 D7050.30 Yes 300 A A+
Level 4 Fuel‐Oil Detection and Alarm 21‐04 70 50 40 D7050.40 Yes 300 A A+
Level 4 Refrigeration Detection and Alarm 21‐04 70 50 50 D7050.50 Yes 300 A A+
Level 4 Water Intrusion Detection and Alarm 21‐04 70 50 60 D7050.60 Yes 300 A A+
Level 3 Electronic Monitoring and Control 21‐04 70 70 D7070 Yes ● ● ●
Level 4 Electronic Detection Monitoring and Control 21‐04 70 70 10 D7070.10 Yes 300 A A+
Level 3 Electronic Safety and Security Supplementary
Components 21‐04 70 90 D7090 Yes ● ● ●
Level 4 Supplementary Components 21‐04 70 90 10 D7090.10 Yes 100 ‐ ‐
Level 2 INTEGRATED AUTOMATION 21‐04 80 D80 Yes ● ● ●
Level 3 Integrated Automation Facility Controls 21‐04 80 10 D8010 Yes ● ● ●
Level 4 Integrated Automation Control of Equipment 21‐04 80 10 10 D8010.10 Yes 200 B B+
Level 4 Integrated Automation Control of Conveying
Equipment 21‐04 80 10 20 D8010.20 Yes 200 B B+
Level 4 Integrated Automation Control of Fire‐
Suppression Systems 21‐04 80 10 30 D8010.30 Yes 200 B B+
Level 4 Integrated Automation Control of HVAC Systems 21‐04 80 10 40 D8010.40 Yes 200 B B+
Level 4 Integrated Automation Control of Plumbing 21‐04 80 10 50 D8010.50 Yes 200 B B+
Level 4 Integrated Automation Control of Electrical 21‐04 80 10 60 D8010.60 Yes 200 B B+
Level 4 Integrated Automation Control of
Communication Systems 21‐04 80 10 70 D8010.70 Yes 200 B B+
Level 4 Integrated Automation Control of Electronic
Safety and Security Systems 21‐04 80 10 80 D8010.80 Yes 200 B B+
Level 4 Integrated Automation Supplementary 21‐04 80 10 90 D8010.90 Yes 200 B B+
Level 1 EQUIPMENT & FURNISHINGS 21‐05 00 00 E Yes ● ● ●
Level 2 EQUIPMENT 21‐05 10 00 E10 Yes ● ● ●
Page 16 of 22 Tab 3. Scope‐LOD‐Grade
Primary Discipline
(Lessor design and construction team may identify discipline specific areas of content)
Exhibit B-10
(DID & CD
DOCUMENTS)
RECORD
MODEL
(AS‐BUILTS)
Level Element ID
OmniClass
ID
UniFormat
ID MasterFormat ID
Included in Facility or Site?
(change to NO if
NOT part of project scope) LOD
GRADE
(CD)
GRADE
(AB)
Notes
Level 3 Vehicle and Pedestrian Equipment 21‐05 10 10 E1010 11 10 00 Yes ● ● ●
Level 4 Vehicle Servicing Equipment 21‐05 10 10 10 E1010.10 11 11 00 NO N/A N/A N/A
Level 4 Interior Parking Control Equipment 21‐05 10 10 30 E1010.30 11 12 00 Yes 200 A A+
Level 4 Loading Dock Equipment 21‐05 10 10 50 E1010.50 11 13 00 Yes 200 A A+
Level 4 Interior Pedestrian Control Equipment 21‐05 10 10 70 E1010.70 11 14 00 Yes 200 A A+
Level 3 Commercial Equipment 21‐05 10 30 E1030 11 20 00 Yes ● ● ●
Level 4 Mercantile and Service Equipment 21‐05 10 30 10 E1030.10 11 21 00 NO N/A N/A N/A
Level 4 Vault Equipment 21‐05 10 30 20 E1030.20 11 16 00 NO N/A N/A N/A
Level 4 Teller and Service Equipment 21‐05 10 30 25 E1030.25 11 17 00 NO N/A N/A N/A
Level 4 Refrigerated Display Equipment 21‐05 10 30 30 E1030.30 11 22 00 NO N/A N/A N/A
Level 4 Commercial Laundry and Dry Cleaning 21‐05 10 30 35 E1030.35 NO N/A N/A N/A
Level 4 Maintenance Equipment 21‐05 10 30 40 E1030.40 11 24 00 NO N/A N/A N/A
Level 4 Hospitality Equipment 21‐05 10 30 50 E1030.50 11 25 00 NO N/A N/A N/A
Level 4 Unit Kitchens 21‐05 10 30 55 E1030.55 11 26 00 NO N/A N/A N/A
Level 4 Photographic Processing Equipment 21‐05 10 30 60 E1030.60 11 27 00 NO N/A N/A N/A
Level 4 Postal, Packaging, and Shipping Equipment 21‐05 10 30 70 E1030.70 11 29 00 Yes 200 C C
Level 4 Office Equipment 21‐05 10 30 75 E1030.75 11 28 00 Yes 200 C C
Level 4 Foodservice Equipment 21‐05 10 30 80 E1030.80 11 40 00 Yes 200 C C
Level 3 Institutional Equipment 21‐05 10 40 E1040 11 50 00 Yes ● ● ●
Level 4 Educational and Scientific Equipment 21‐05 10 40 10 E1040.10 11 50 00 NO N/A N/A N/A
Level 4 Healthcare Equipment 21‐05 10 40 20 E1040.20 11 70 00 NO N/A N/A N/A
Level 4 Religious Equipment 21‐05 10 40 40 E1040.40 11 91 00 NO N/A N/A N/A
Level 4 Security Equipment 21‐05 10 40 60 E1040.60 11 18 00 Yes 300 A A+
Level 4 Detention Equipment 21‐05 10 40 70 E1040.70 11 19 00 NO N/A N/A N/A
Level 3 Residential Equipment 21‐05 10 60 E1060 11 30 00 NO ● ● ●
Level 4 Residential Appliances 21‐05 10 60 10 E1060.10 11 31 00 NO N/A N/A N/A
Level 4 Retractable Stairs 21‐05 10 60 50 E1060.50 11 33 00 NO N/A N/A N/A
Level 4 Residential Ceiling Fans 21‐05 10 60 70 E1060.70 11 34 00 NO N/A N/A N/A
Level 3 Entertainment and Recreational Equipment 21‐05 10 70 E1070 Yes ● ● ●
Level 4 Theater and Stage Equipment 21‐05 10 70 10 E1070.10 11 61 00 Yes 200 C C
Level 4 Musical Equipment 21‐05 10 70 20 E1070.20 11 62 00 NO N/A N/A N/A
Level 4 Athletic Equipment 21‐05 10 70 50 E1070.50 11 66 00 Yes 200 C C
Level 4 Recreational Equipment 21‐05 10 70 60 E1070.60 11 67 00 NO N/A N/A N/A
Level 3 Other Equipment 21‐05 10 90 E1090 11 90 00 Yes ● ● ●
Level 4 Solid Waste Handling Equipment 21‐05 10 90 10 E1090.10 11 82 00 Yes 200 A A+
Level 4 Agricultural Equipment 21‐05 10 90 30 E1090.30 11 92 00 NO N/A N/A N/A
Level 4 Horticultural Equipment 21‐05 10 90 40 E1090.40 11 93 00 NO N/A N/A N/A
Level 4 Decontamination Equipment 21‐05 10 90 60 E1090.60 NO N/A N/A N/A
Level 2 FURNISHINGS 21‐05 20 E20 12 00 00 Yes ● ● ●
Level 3 Fixed Furnishings 21‐05 20 10 E2010 Yes ● ● ●
Level 4 Fixed Art 21‐05 20 10 10 E2010.10 12 10 00 NO N/A N/A N/A
Level 4 Window Treatments 21‐05 20 10 20 E2010.20 12 20 00 NO N/A N/A N/A
Level 4 Casework 21‐05 20 10 30 E2010.30 12 30 00 Yes 350 A A+
Level 4 Fixed Multiple Seating 21‐05 20 10 70 E2010.70 12 60 00 Yes 200 A A+
Level 4 Other Fixed Furnishings 21‐05 20 10 90 E2010.90 12 90 00 Yes 200 A A+
Level 3 Movable Furnishings 21‐05 20 50 E2050 Yes ● ● ●
Level 4 Movable Art 21‐05 20 50 10 E2050.10 12 10 00 NO N/A N/A N/A
Page 17 of 22 Tab 3. Scope‐LOD‐Grade
Primary Discipline
(Lessor design and construction team may identify discipline specific areas of content)
Exhibit B-10
(DID & CD
DOCUMENTS)
RECORD
MODEL
(AS‐BUILTS)
Level Element ID
OmniClass
ID
UniFormat
ID MasterFormat ID
Included in Facility or Site?
LOD
GRADE
(CD)
GRADE
(AB)
Notes
Level 4 Furniture 21‐05 20 50 30 E2050.30 12 50 00 Yes 300 A A+
Level 4 Accessories 21‐05 20 50 40 E2050.40 12 40 00 Yes 100 B B+
Level 4 Movable Multiple Seating 21‐05 20 50 60 E2050.60 12 60 00 Yes 300 A A+
Level 4 Other Movable Furnishings 21‐05 20 50 90 E2050.90 12 90 00 Yes 300 A A+
Level 1 SPECIAL CONSTRUCTION AND DEMOLITION 21‐06 00 00 F Yes ● ● ●
Level 2 SPECIAL CONSTRUCTION 21‐06 10 F10 Yes ● ● ●
Level 3 Integrated Construction 21‐06 10 10 F1010 Yes ● ● ●
Level 4 Building Modules 21‐06 10 10 10 F1010.10 13 42 00 Yes 200 A A+
Level 4 Manufactured/Fabricated Rooms 21‐06 10 10 50 F1010.50 13 20 00 Yes 200 A A+
Level 4 Modular Mezzanines 21‐06 10 10 70 F1010.70 13 44 00 Yes 200 A A+
Level 3 Special Structures 21‐06 10 20 F1020 13 30 00 Yes ● ● ●
Level 4 Fabric Structures 21‐06 10 20 10 F1020.10 13 31 00 Yes 200 A A+
Level 4 Space Frames 21‐06 10 20 20 F1020.20 13 32 00 Yes 200 A A+
Level 4 Geodesic Structures 21‐06 10 20 30 F1020.30 13 33 00 NO N/A N/A N/A
Level 4 Manufacturer‐Engineered Structures 21‐06 10 20 40 F1020.40 13 34 00 NO N/A N/A N/A
Level 4 Manufactured Canopies 21‐06 10 20 60 F1020.60 10 73 16 NO N/A N/A N/A
Level 4 Rammed Earth Construction 21‐06 10 20 65 F1020.65 13 35 00 NO N/A N/A N/A
Level 4 Towers 21‐06 10 20 70 F1020.70 13 36 00 Yes 200 A A+
Level 3 Special Function Construction 21‐06 10 30 F1030 NO ● ● ●
Level 4 Sound and Vibration Control 21‐06 10 30 10 F1030.10 13 48 00 NO N/A N/A N/A
Level 4 Seismic Control 21‐06 10 30 30 F1030.30 13 48 00 NO N/A N/A N/A
Level 4 Radiation Protection 21‐06 10 30 50 F1030.50 13 49 00 NO N/A N/A N/A
Level 3 Special Facility Components 21‐06 10 50 F1050 Yes ● ● ●
Level 4 Pools 21‐06 10 50 10 F1050.10 NO N/A N/A N/A
Level 4 Interior Fountains 21‐06 10 50 20 F1050.20 13 12 23 Yes 300 A A+
Level 4 Interior Water Features 21‐06 10 50 30 F1050.30 Yes 300 A A+
Level 4 Aquariums 21‐06 10 50 40 F1050.40 13 13 00 NO N/A N/A N/A
Level 4 Amusement Park Structures and Equipment 21‐06 10 50 50 F1050.50 13 14 00 NO N/A N/A N/A
Level 4 Ice Rinks 21‐06 10 50 60 F1050.60 13 18 00 NO N/A N/A N/A
Level 4 Animal Containment 21‐06 10 50 70 F1050.70 13 19 00 NO N/A N/A N/A
Level 3 Athletic and Recreational Special Construction 21‐06 10 60 F1060 13 28 00 NO ● ● ●
Level 4 Indoor Soccer Boards 21‐06 10 60 10 F1060.10 13 28 13 NO N/A N/A N/A
Level 4 Safety Netting 21‐06 10 60 20 F1060.20 13 28 16 NO N/A N/A N/A
Level 4 Arena Football Boards 21‐06 10 60 30 F1060.30 13 28 19 NO N/A N/A N/A
Level 4 Floor Sockets 21‐06 10 60 40 F1060.40 13 28 26 NO N/A N/A N/A
Level 4 Athletic and Recreational Court Walls 21‐06 10 60 50 F1060.50 13 28 33 NO N/A N/A N/A
Level 4 Demountable Athletic Surfaces 21‐06 10 60 60 F1060.60 13 28 66 NO N/A N/A N/A
Level 3 Special Instrumentation 21‐06 10 80 F1080 13 50 00 NO ● ● ●
Level 4 Stress Instrumentation 21‐06 10 80 10 F1080.10 13 51 00 NO N/A N/A N/A
Attachment H Page 18 of 22 Tab 3. Scope‐LOD‐Grade
Primary Discipline
(Lessor design and construction team may identify discipline specific areas of content)
Exhibit B-10
(DID & CD
DOCUMENTS)
RECORD
MODEL
(AS‐BUILTS)
Level Element ID
OmniClass
ID
UniFormat
ID MasterFormat ID
Included in Facility or Site?
LOD
GRADE
(CD)
GRADE
(AB)
Notes
Level 4 Seismic Instrumentation 21‐06 10 80 20 F1080.20 13 51 00 NO N/A N/A N/A
Level 4 Meteorological Instrumentation 21‐06 10 80 40 F1080.40 13 51 00 NO N/A N/A N/A
Level 4 Earth Movement Monitoring 21‐06 10 80 60 F1080.60 NO N/A N/A N/A
Level 2 FACILITY REMEDIATION 21‐06 20 00 F20 NO ● ● ●
Level 3 Hazardous Materials and Remediation 21‐06 20 10 F2010 NO ● ● ●
Level 4 Transportation and Disposal of Hazardous
Materials
21‐06 20 10 10 F2010.10 NO N/A N/A N/A