Exhibit B - Agency Requirements RLP.pdf

PDF 554 KB Posted

Attached to
Clinical Space Surprise AZ
Solicitation number
36C24W26R0053
Issued by

About this file

This document is an Agency Long Term Space Requirements Needs Interview Questionnaire completed by the VA Phoenix Health Care System (PVAHCS) for a new clinical space lease initiative.

The VA seeks to lease approximately 9,281 usable square feet of space to support PVAHCS initiatives, with a focus on offering timely, quality services for Veterans. The project encompasses multiple clinical and administrative functions, including Physical Medicine and Rehabilitation services, Mental Health patient care, Eye Clinic/Optical services, Community Based Outpatient Clinic (PACT), and Pathology and Laboratory Medicine services. The lease term is 10 years with a 5-year firm term for tenant improvement (TI) cost recovery. The agency currently has 37 staff members and requires 70 parking spaces for privately owned vehicles within 0.1 miles of the building. The delineated area is bounded by W. Mountain View Boulevard, W RH Johnson Boulevard, West Greenway Road, and AZ State Route 303 in a non-rural location with proximity to public transportation. Weekday operations run 6:30 AM to 5:30 PM with after-hours access required for janitorial and maintenance services. The facility must meet Security Level II requirements with intrusion detection, access control systems, sealed IT room walls extending to overhead structure, and dedicated locks. GSA assistance is needed for IT/Network and Telecommunication Services, furniture acquisition, office equipment, security products, and move coordination. The agency will participate in Design Intent Drawing (DID) workshops with key decision-makers including the Chief Engineer, Space Planning, Service Chiefs, and Contracting Officer Representative. Circulation is accounted for in the square footage request, and new furniture will be purchased rather than moved.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

8/20/2025| Page 1 of 12

Agency Long Term Space Requirements Needs Interview Questionnaire

General Project Information

Basic Information

1. Brief description of the location’s daily operations and functions (e.g. typical office, interactions with the public, appeals office, regional office, rapid response center, & etc.)

Clinical Space

2. Purpose of this project / move: Initiate new lease in support of PVAHCS initiatives

3. How does the agency define success?The VA Phoenix Health Care System focuses on offering timely, quality services for Veterans.

4. Constraints: Budget , Resources , Schedule , Organizational Change , & Mission Change

a. Notes:

5. Assistance needed from GSA for: IT/Network & Telecommunication Services , Local & Long Distance Phone

Service , Furniture Acquisition , Furniture & Personal Property Disposal , Office Equipment Acquisition , Security Products & Services , Move Coordination

6. Total Staff / Headcount: Current 37 Future

7. For restroom calculations: New location percentage of staff women n/a%, staff men n/a%

8. Furniture: Move Existing or Buy New

New Lease Term

9. Full Term 10 years

10. Firm Term (Period TIs are paid off) 5 years

11. Has the agency considered potential office consolidations and closings? Yes No Notes:

Square Footage

12. Total Usable Square Footage Requested 9281 ABOA

13. Is circulation accounted for in the square footage? Yes No Notes:

8/20/2025| Page 2 of 12

Needs Interview Questionnaire

a. Typically Circulation is calculated as 25-35% of the total USF requested. GSA does not add circulation to the USF submitted by agencies. The initial USF submitted by the agency must include the allowance for it.

14. Does this square footage account for agency-wide space reduction goals? Yes No Notes:

Delineated Area Boundaries (Must form a complete closed loop of connecting streets)

Requested Delineated Area:

15. North: W. Mountain View Blvd -> West RH Johnson Bl // East: West RH Johnson Bl -> North Nash St // South: West Greenway Road // West: AZ State Route 303

16. Is this area within a rural county? No If yes, please skip to question 23. If no, please proceed to question 20.

17. Obtain a justification for not locating within a rural county (see Rural Development Act) A rural area cannot meet our agency’s space needs

18. Are these boundaries within the city’s Central Business District (CBD)? Yes If yes, please skip to question 23. If no, please proceed to question 22.

19. Obtain a justification related to the mission of this office for not locating within the CBD.

20. Are there any requirements for proximity to public transportation? Yes

21. Are there any setback requirements (ex. residential, day care, churches, etc)? No

Hours of Operation

25. Weekday hours of operation: 0630-1730

26. Weekend hours of operation: X Not Applicable Notes:

27. After hours access required: Yes No Notes: Janitorial and maintenance services

28. After hours utilities required: Yes No Notes:

29. Are after hours or daytime cleaning services required? To be included in the lease Notes:

Security

8/20/2025| Page 3 of 12

Needs Interview Questionnaire

Notes: (FPS Level for current Lease): II 1. Agency’s Security Level: II Unknown

2. Unique Security Constraints: Yes No Notes:

3. Security constraints that limit the use of signage, American flags, and symbols that may indicate the presence of a federal agency? Yes No Notes:

4. How does the agency want to manage employee access to the space? Keys , Cards , Other

5. Does the agency need to manage visitor access to the space? Yes No Notes:

Parking

6. Number of parking spaces required n/a *Government Owned Vehicles Only (Included on SF-81 & Rent)

a. Security Needs: Gate Controlled , Fenced , or Visually Private

b. Location: Inside Basement , Outside Surface , Outside Structured , or No Preference

7. Number of employee &/or visitor parking spaces 70 *Privately Owned Vehicles (Not on SF-81 & Rent)

a. Parking to be within .1 miles of the building.

8. Bicycle parking Yes No Notes:

8/20/2025| Page 4 of 12

Needs Interview Questionnaire

New Space

Building / Site

1. Does the agency need to be co-located with another agency or department? Yes No

Notes:

2. Must the space be contained in one contiguous block without being split by a public corridor? Yes No

Notes:

3. Column spacing requirement: Yes No Span

4. Must the space be located on a particular floor of a building? Yes No Notes:

5. External adjacency requirements (ex. proximity to courthouses, etc.) Yes No Notes:

6. Proximity to amenities / building support services? Not Applicable

a. Food Service , Fitness Center , Credit Union , &/or Onsite Health Unit

b. Other: Banks, Restaurants, shopping

7. Proximity to mass transit? Yes No Distance away in miles:

8. Preference for a Class of Building? Class A , Class B , Class C/Flex , & / or no preference

Notes:

9. Does the agency require the ability to display signage? Interior Exterior Not Applicable

10. Does the agency require a business directory? Yes No

11. Does the agency require on-site vending machines? Yes No

12. Does the agency require a flag pole? Yes No

8/20/2025| Page 5 of 12

Needs Interview Questionnaire

13. Ceiling Height Minimum Clearance: 8’

Construction & Finishes

14. Requirement for window coverings such as blinds or draperies ? No Preference Notes:

15. How frequently would the agency like the space re-carpeted? (Typically every 5-10 years) 5 years

16. How frequently would the agency like the space re-painted? (Typically every 5-10 years) 3 years

17. Are floor grills or grates required to control outside dirt from external entryways? Yes No

18. Does the agency have any sustainability goals beyond the existing regulations, existing laws, and

Executive Orders in effect? Yes No Notes:

19. Sealed conduit for telecommunications: Yes No Notes:

20. Unique HVAC requirements: Yes No Notes:

a. Server Room? Yes No Notes:

b. Mail Room? Yes No Notes:

c. Other? Yes No Notes:

21. Antennas or a satellite dish on the roof: Yes No Notes:

22. Ware yard: Yes No Notes:

23. Loading Dock: Yes No Notes:

24. Freight Elevator: Yes No Notes: Assume ground floor occupancy.

Project Schedule

1. Does the agency require pre-occupancy tenant access for the set-up of equipment? Yes No

Number of days needed 30

2. Will the agency prepare the DIDs (Design Intent Drawings?) Yes No

3. Days agency needs to prepare the DIDs: NA Business Days

4. Days agency needs to review the DIDs, if the Lessor generates them: 10 Business Days

5. Days agency needs to review DID changes: 10 Business Days

6. Days agency needs to review the Construction Documents (CDs): 15 Business Days

7. Days agency needs to review modifications to the CDs: 10 Business Days

8/20/2025| Page 6 of 12

Needs Interview Questionnaire

8. Days agency needs to review the RLP (previously known as the SFO): 30 Business Days

DID Workshops DID workshops are 1-3 day meetings held after award hosted by the Lessor with their architect. During this meeting, the agency and the Lessor’s architect develop and finalize the Design Intent Drawing. This process can substantially speed up the post award design process and can take months off of the project time, allowing the agency to occupy their space sooner. DID workshops also provide for a more collaborative design process resulting in a design that will better meet the needs of the agency which increases overall satisfaction with the space. In order for this process to be successful, the agency must bring all of the “decision makers” to the meeting and be prepared to approve the DID.

1. Is the agency willing to participate in a DID workshop? Yes No Notes:

2. Who are the individuals that will need to participate in the workshop in order to approve the DIDs?

Chief Engineer, Space Planning, Service Chiefs, COR

Please Note: Agencies must agree to the DID workshop prior to issuance of the RLP in order to ensure that the Lease document contains the proper clauses.

8/20/2025| Page 7 of 12

Needs Interview Questionnaire

1. Offices: Private Walled-in: Quantity & Size Standard Finishes? Yes No

a. Flooring type Carpet Tile or LVP

b. Wall finish type Textured

c. Ceiling type Lay-in acoustic,

d. Quantity duplex electrical outlets 1 per wall,

e. Quantity data outlets 2 per room

f. Wall Type: Metal framed gypsum board, sound batting

g. Sound Transmission Coefficient (STC) Requirement (if other than standard): 45

h. Additional Needs:

2. Offices: Open Workstations (cubicles): Quantity & Size Standard Finishes? Yes No

a. Flooring type carpet tile

b. Wall finish type Textured gypsum board

c. Ceiling type Lay-in acoustic

d. Quantity duplex electrical outlets 2 per work station

e. Quantity data outlets 2 per work station

f. Wall Type (if other than standard specified by code): Metal framed gypsum board, sound batting

g. Sound Transmission Coefficient (STC) Requirement (if other than standard): 45

h. Additional Needs:

3. Conference Room(s): Quantity 1 & Size 240sqft

a. Flooring type Carpet tiles,

b. Wall finish type Textured gypsum board

c. Ceiling type Lay-in acoustic

d. Quantity duplex electrical outlets One per wall, one for each telecom device, one floor mount in center of room

e. Quantity data outlets One per wall, one per telecom device, one floor mount in center of room

f. Wall Type (if other than standard specified by code): Metal frame gypsum board, sound batting

8/20/2025| Page 8 of 12

Needs Interview Questionnaire

g. Sound Transmission Coefficient (STC) Requirement (if other than standard): 45

h. Additional Needs:

4. Reception Room: Quantity 1 & Size 385sqft Standard Finishes? Yes No

a. Flooring type wood grain vinyl plank

b. Wall finish type Textured gypsum board

c. Ceiling type Lay-in acoustic

d. Quantity duplex electrical outlets One per wall, One additional at work station

e. Quantity data outlets Two at work station

f. Wall Type (if other than standard specified by code): Metal frame Gypsum board, Sound batting

g. Sound Transmission Coefficient (STC) Requirement (if other than standard): 45

h. Additional Needs:

5. Server Room: Quantity 1 & Size 170sqft Standard Finishes? Yes No

a. Flooring type

b. Wall finish type Textured gypsum board

c. Ceiling type Gypsum board hard ceiling

d. Quantity duplex electrical outlets One per wall

e. Quantity data outlets ISP data cable and punch block

f. Wall Type (if other than standard specified by code): Metal frame, gypsum board, sound batting

g. Sound Transmission Coefficient (STC) Requirement (if other than standard): 45

h. Additional Needs: Server room must be protected from unauthorized entry, usually by extending walls to overhead structure.

6. Storage Room: Quantity 5 & Size 120sqft Standard Finishes? Yes No

a. Flooring type Wood grain vinyl plank

b. Wall finish type Textured gypsum board

c. Ceiling type Lay-in acoustic

d. Quantity duplex electrical outlets one per wall

8/20/2025| Page 9 of 12

Needs Interview Questionnaire

e. Quantity data outlets None

f. Wall Type (if other than standard specified by code): Metal frame gypsum board

g. Sound Transmission Coefficient (STC) Requirement (if other than standard):

h. Additional Needs: Enclosure needs to be fire rated for one hour

7. File Room: Quantity NA & Size Standard Finishes? Yes No

a. Flooring type Wood grain vinyl plank

b. Wall finish type Textured gypsum board

c. Ceiling type Lay-in acoustic

d. Quantity duplex electrical outlets One per wall

e. Quantity data outlets None

f. Floor load for safe or files: 100 psf

g. Wall Type (if other than standard specified by code): Metal frame gypsum board, sound batting

h. Sound Transmission Coefficient (STC) Requirement (if other than standard): 45

i. Additional Needs: Enclosure needs to be fire rated for one hour.

8. Mailroom: Quantity NA & Size Standard Finishes? Yes No

a. Flooring type

b. Wall finish type

c. Ceiling type

d. Quantity duplex electrical outlets

e. Quantity data outlets

f. Wall Type (if other than standard specified by code):

g. Sound Transmission Coefficient (STC) Requirement (if other than standard):

h. Additional Needs:

9. Breakroom: Quantity 1 & Size 220sqft Standard Finishes? Yes No

a. Flooring type Wood grain vinyl plank

b. Wall finish type Textured gypsum board

8/20/2025| Page 10 of 12

Needs Interview Questionnaire

c. Ceiling type lay-in acoustic

d. Quantity duplex electrical outlets One per wall, one for refrigerator, one above counter for microwave and coffee maker

e. Wall Type (if other than standard specified by code): Metal frame gypsum board, sound batting

f. Sound Transmission Coefficient (STC) Requirement (if other than standard): 45

g. Quantity data outlets None

h. Sink , Microwave , Refrigerator (dorm size standard size ,) Cabinets

i. Seating for 15 people

i. Wall Type (if other than standard specified by code): Metal frame gypsum board, sound batting

j. Sound Transmission Coefficient (STC) Requirement (if other than standard): 45

k. Additional Needs: Tap for ice maker in refrigerator

10. Space for Copiers, Fax, Bookshelves, & Shared Printer Stations: Quantity & Size

a. Flooring type Wood grain vinyl plank

b. Wall finish type Textured gypsum board

c. Ceiling type Lay-in acoustic

d. Quantity duplex electrical outlets One per wall, one per device

e. Quantity data outlets One per device

f. Wall Type (if other than standard specified by code): Metal frame gypsum board, sound batting

g. Sound Transmission Coefficient (STC) Requirement (if other than standard): 45

h. Additional Needs: Enclosure needs to be fire rated for one hour.

11. Reception / Entry Space: Quantity & Size Standard Finishes? Yes No

a. Flooring type Wood grain vinyl plank

b. Wall finish type Textured gypsum board

c. Ceiling type Lay-in acoustic

d. Quantity duplex electrical outlets One per wall, one at work station

e. Quantity data outlets Two at work station

8/20/2025| Page 11 of 12

Needs Interview Questionnaire

f. Wall Type (if other than standard specified by code): Metal frame gypsum board, sound batting

g. Sound Transmission Coefficient (STC) Requirement (if other than standard): 45

h. Additional Needs: Tile, masonry or painted accent wall

12. Additional unique spaces or functions

Blood Specimen collection: Quantity 7 & Size 100sqft

a. Flooring type

b. Wall finish type

c. Ceiling type

d. Quantity duplex electrical outlets

e. Quantity data outlets

f. Wall Type (if other than standard specified by code):

g. Sound Transmission Coefficient (STC) Requirement (if other than standard):

h. Additional Needs:

Ore Lab Specimen Room: Quantity 1 & Size 350sqft

a. Flooring type

b. Wall finish type

c. Ceiling type

d. Quantity duplex electrical outlets

e. Quantity data outlets

f. Wall Type (if other than standard specified by code):

g. Sound Transmission Coefficient

13. Video Conferencing Equipment: Yes No

14. Internal (departments or other) space adjacencies required: Yes No Notes:

Design Schematic Layout (recommended, but not required for the Streamlined model TI allowance option)

1. Do you have a required layout for this office? Yes No Notes:

2. Do you have any adjacency plans? Yes No Notes:

8/20/2025| Page 12 of 12

Needs Interview Questionnaire

Note: If the agency cannot supply a sample layout, check other recent projects for that agency for potential layouts that can be used. If no layout is available, contact appropriate GSA staff to help them develop one.

Special Requirements

1. Do you have any specialty items which are not standard to an office? Yes No Notes:

2. Do you have construction specifications for these items? Yes No Notes:

General Requirements

1. Do you have any special IT requirements or standards other than specified above? Yes No Notes:

Are cable trays required? No Who is purchasing data cable? Landlord Who is responsible for installing data cable? Landlord Who is purchasing telecommunications cable? Landlord Who is responsible for installing telecommunications cable? Landlord Are sealed conduits required for wall mounted outlets? Yes Who is responsible for termination data/telecommunication connections? Agency

2. Do you have any special security requirements (intrusion detection system, access control system, etc.) Yes

No Notes: Intrusion detection, access control system, IT room walls sealed to overhead superstructure, no windows, limited access, dedicated locks, self-contained air conditioning system.

Are cable trays required?

Who is purchasing data cable?

Who is responsible for installing data cable?

Who is purchasing tele-communications cable?

Who is responsible for installing tele-communications cable?

Are sealed conduits required for wall mounted outlets?

Who is responsible for terminating data/telecommunication connections?

Yes Landlord Landlord Landlord Landlord Yes, back to demark Agency

PROGRAM FOR DESIGN

SURPRISE OPTICAL and PHYSICAL THERAPY CLINICS

Projected Year: 2026 Midpoint Year: 2026

VISN: 18 State: AZ State: 644 Station: Phoenix

Installation: VA Medical Center

Project Created: 7/24/2024 3:05:14 PM by Bryan Kwon Space Plan Last Edited: 12/11/2024 6:06:47 PM by Shaun O'Brien

Contents List Created: 9/4/2024 4:35:18 PM by Shaun O'Brien Contents List Last Edited: 12/11/2024 6:10:13 PM by Shaun O'Brien

Report Generated: 13 Dec 2024 11:24AM ET

Department: 01 - PHYSICAL MEDICINE AND REHABILITATION SERVICE (270)

Functional Area: 02 - PHYSICAL THERAPY (PT) AREA

Qty Room Code Room Name Unit Area Net Area Const Phase Const Type

1 CT024 Multipurpose Group Room, PMR Svc 320 320 1 0

1 CT024 Multipurpose Group Room, PMR Svc 600 600 1 0

1 CT045 PT Supply Storage Room, PMR Svc 100 100 1 0

1 SB163 Bariatric Patient Toilet, Bldg Sprt 75 75 1 0

FA Totals: Room Qty: 4 Net Area: 1,095 Gross Area: 1,478

Department: 01 - PHYSICAL MEDICINE AND REHABILITATION SERVICE (270)

Functional Area: 03 - PMR SVC STAFF AND ADMINISTRATIVE AREA

Qty Room Code Room Name Unit Area Net Area Const Phase Const Type

1 WRTM1 Team Room 200 200 1 0

FA Totals: Room Qty: 1 Net Area: 200 Gross Area: 270

Dept Totals: Room Qty: 5 Net Area: 1,295 Gross Area: 1,748

Department: 02 - MENTAL HEALTH PATIENT CARE UNIT (MH PCU) (110)

Functional Area: 02 - PATIENT CARE UNIT (PCU) STAFF-PATIENT AREA

Qty Room Code Room Name Unit Area Net Area Const Phase Const Type

8 OFDC1 Consult Room, Mental Health 125 1000 1 0

FA Totals: Room Qty: 8 Net Area: 1,000 Gross Area: 1,650

Department: 02 - MENTAL HEALTH PATIENT CARE UNIT (MH PCU) (110)

Functional Area: 04 - PATIENT CARE UNIT (PCU) PATIENT COMMON AREA

Qty Room Code Room Name Unit Area Net Area Const Phase Const Type

2 SB201 MH PCU Patient Toilet, Bldg Sprt 60 120 1 0

FA Totals: Room Qty: 2 Net Area: 120 Gross Area: 198

PROGRAM FOR DESIGN

SURPRISE OPTICAL SHOP, PM&RS GYM, PC/MH (12/11/24)

Page 2 of 6FOR OFFICIAL USE ONLY13 Dec 2024 11:24AM ET

Department: 02 - MENTAL HEALTH PATIENT CARE UNIT (MH PCU) (110)

Functional Area: 05 - PATIENT CARE UNIT (PCU) SUPPORT AREA

Qty Room Code Room Name Unit Area Net Area Const Phase Const Type

1 OFA09 Office, Medium 100 100 1 0

1 SB244 Housekeeping Aides Closet (HAC), Bldg Sprt 60 60 1 0

1 SB252 MH Wheelchair / Stretcher Alcove, Bldg Sprt 50 50 1 0

1 SB663 General Storage Room, Lgstcs Svc 120 120 1 0

1 SS209 Shared Office, Stff Sprt 120 120 1 0

1 TNPG1 Toilet, Non-Patient, Single User, Universal 60 60 1 0

FA Totals: Room Qty: 6 Net Area: 510 Gross Area: 842

Department: 02 - MENTAL HEALTH PATIENT CARE UNIT (MH PCU) (110)

Functional Area: 09 - MENTAL HEALTH STAFF AND ADMINISTRATIVE AREA

Qty Room Code Room Name Unit Area Net Area Const Phase Const Type

1 LR001 Locker, Staff Personal Property 60 60 1 1

1 SL001 Lounge, Staff 220 220 1 1

FA Totals: Room Qty: 2 Net Area: 280 Gross Area: 462

Dept Totals: Room Qty: 18 Net Area: 1,910 Gross Area: 3,152

Department: 03 - EYE CLINIC: OPHTHALMOLOGY AND OPTOMETRY SERVICES (233)

Functional Area: 02 - OPTICAL FITTING AREA

Qty Room Code Room Name Unit Area Net Area Const Phase Const Type

1 CEY91 Optical Fitting Area Eyeglass Fitting / Dispensing Room, Eye Clnc 400 400 1 0

1 CEY95 Optical Fitting Area Eyeglass Frame Storage Room, Eye Clnc 80 80 1 0

FA Totals: Room Qty: 2 Net Area: 480 Gross Area: 768

Dept Totals: Room Qty: 2 Net Area: 480 Gross Area: 768

PROGRAM FOR DESIGN

Page 3 of 6FOR OFFICIAL USE ONLY13 Dec 2024 11:24AM ET

Department: 04 - COMMUNITY BASED OUTPATIENT CLINIC (PACT) INTERIM (263)

Functional Area: 01 - LOBBY / RECEPTION AREA

Qty Room Code Room Name Unit Area Net Area Const Phase Const Type

1 LAC01 Lactation Room 100 100 1 1

1 RCP03 Reception 385 385 1 1

1 SRLW1 Alcove, Wheelchair 90 90 1 1

1 TNPF1 Toilet, Female 250 250 1 1

1 TNPFM Toilet, Family 80 80 1 1

1 TNPM1 Toilet, Male 250 250 1 1

1 WTPC1 Waiting, PACT 1 1260 1260 1 1

FA Totals: Room Qty: 7 Net Area: 2,415 Gross Area: 3,623

Department: 04 - COMMUNITY BASED OUTPATIENT CLINIC (PACT) INTERIM (263)

Functional Area: 02 - PATIENT ALIGNED CARE TEAM (PACT) CLINIC 1

Qty Room Code Room Name Unit Area Net Area Const Phase Const Type

1 CSUS1 Utility Room, Soiled 40 40 1 0

6 EXPA1 Exam Room, Patient Aligned Care Team (PACT) 125 750 1 1

1 LR001 Locker, Staff Personal Property 60 60 1 1

16 OFA07 Workstation, Medium 56 896 1 0

2 OFA09 Office, Medium (Supv) 100 200 1 0

2 OFDC2 Consult Room, Patient Aligned Care Team (PACT) 125 250 1 1

1 PEHW2 Alcove, Height / Weight Accessible Station 40 40 1 1

1 RCA01 Alcove, AED 20 20 1 1

1 RCA06 Alcove, Medication 20 20 1 1

1 SB163 Bariatric Patient Toilet, Bldg Sprt 75 75 1 0

2 SB201 Universal Patient Toilet, Bldg Sprt 60 120 1 0

1 SL001 Lounge, Staff 220 220 1 1

1 SRE01 Storage, Medical Equipment 120 120 1 1

1 SRE01 Storage, Shared Medical Appointments 100 100 1 1

2 TNPG1 Toilet, Staff 60 120 1 1

1 TPB01 Toilet, General Procedure Room Patient 75 75 1 1

PROGRAM FOR DESIGN

Page 4 of 6FOR OFFICIAL USE ONLY13 Dec 2024 11:24AM ET

Department: 04 - COMMUNITY BASED OUTPATIENT CLINIC (PACT) INTERIM (263)

Functional Area: 02 - PATIENT ALIGNED CARE TEAM (PACT) CLINIC 1

Qty Room Code Room Name Unit Area Net Area Const Phase Const Type

1 TRPR1 Procedure Room, General 180 180 1 1

1 UCCL1 Utility Room, Clean 60 60 1 1

1 WRTM2 Tele-Health Room 125 125 1 1

1 WRTM3 Tele-Retinal Room 125 125 1 1

FA Totals: Room Qty: 44 Net Area: 3,596 Gross Area: 5,394

Department: 04 - COMMUNITY BASED OUTPATIENT CLINIC (PACT) INTERIM (263)

Functional Area: 05 - STAFF SUPPORT AREA

Qty Room Code Room Name Unit Area Net Area Const Phase Const Type

1 RCA06 Alcove, Medication 20 20 1 1

1 SRE01 Storage, Equipment 100 100 1 1

1 SS294 Conference Room, Stff Sprt 240 240 1 0

FA Totals: Room Qty: 3 Net Area: 360 Gross Area: 540

Department: 04 - COMMUNITY BASED OUTPATIENT CLINIC (PACT) INTERIM (263)

Functional Area: 06 - SUPPORT AREA

Qty Room Code Room Name Unit Area Net Area Const Phase Const Type

1 COMC1 Communications Room 170 170 1 1

1 JANC1 Housekeeping Aides Closet - HAC 80 80 1 1

FA Totals: Room Qty: 2 Net Area: 250 Gross Area: 375

Dept Totals: Room Qty: 56 Net Area: 6,621 Gross Area: 9,932

PROGRAM FOR DESIGN

Page 5 of 6FOR OFFICIAL USE ONLY13 Dec 2024 11:24AM ET

Department: 05 - PATHOLOGY AND LABORATORY MEDICINE SERVICE (240)

Functional Area: 01 - PATIENT SPECIMEN COLLECTION AREA

Qty Room Code Room Name Unit Area Net Area Const Phase Const Type

7 CL101 Blood Specimen Collection Room, Path Svc 100 700 1 0

2 SB164 Path Svc Urine Specimen Collection Toilet, Bldg Sprt 60 120 1 0

FA Totals: Room Qty: 9 Net Area: 820 Gross Area: 1,230

Department: 05 - PATHOLOGY AND LABORATORY MEDICINE SERVICE (240)

Functional Area: 02 - CORE LABORATORY WORK AREA

Qty Room Code Room Name Unit Area Net Area Const Phase Const Type

1 CL111 Core Lab Specimen Room, Path Svc 350 350 1 0

FA Totals: Room Qty: 1 Net Area: 350 Gross Area: 525

Department: 05 - PATHOLOGY AND LABORATORY MEDICINE SERVICE (240)

Functional Area: 05 - STAFF AND ADMINISTRATIVE AREA

Qty Room Code Room Name Unit Area Net Area Const Phase Const Type

1 WRTM1 Team Room 280 280 1 0

FA Totals: Room Qty: 1 Net Area: 280 Gross Area: 420

Dept Totals: Room Qty: 11 Net Area: 1,450 Gross Area: 2,175

Building Totals: Room Qty: 92 Net Area: 11,756 Sum of Dept Gross Area: 17,774 Gross Area: 22,573

PROGRAM FOR DESIGN

Page 6 of 6FOR OFFICIAL USE ONLY13 Dec 2024 11:24AM ET

Agency Long Term Space Requirements
Agency space needs

File details come from the government source that posted it. Updated .