This is a Scope of Work document (Exhibit A) for Seminole County Board of County Commissioners' home reconstruction project located at 1218 W 13th Place, Sanford, Florida. The project involves the reconstruction of a single-family home designed with two bedrooms, two bathrooms, and approximately 1,100 square feet of air-conditioned space (plus or minus 100 square feet), featuring an attached one-car garage. The home shall be constructed on a stem wall foundation with block exterior walls, a hip roof with pre-manufactured truss system, an approximately 80 square-foot front porch under roof, and an approximately 80 square-foot rear patio slab also under roof with a sliding glass door. The project timeline includes ninety (90) days for permitting, one hundred fifty (150) days to substantial completion, and thirty (30) days to final completion, totaling two hundred seventy (270) calendar days. Additional requirements include ADA accessibility provisions, termite protection certification, a six-inch sub-fascia, and compliance with current Florida Building Code requirements.
The Engineer's estimate for this project is $250,000.00. All products and materials listed in the scope may be substituted with equal or greater quality products of equal or lesser cost, provided such substitutions comply with Local, State, and Federal codes and regulations. Bid documents are available through the Seminole County Website at https://secure.procurenow.com/portal/seminolefl. Minority- and Women-Owned Business Enterprises (M/WBEs) are encouraged to participate in the bidding process. Prospective bidders are prohibited from contacting Seminole County staff or officials except through the specified contact person.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
EXHIBIT A
Stacey Smithwick Highlight
Stacey Smithwick Highlight
Substitutions:
All products and materials listed herein may be substituted with an “equal or greater” quality product and /or material of “equal or lesser cost” or as required by Local, State and Federal codes or regulations. The manufactured brands stated herein for certain products will be considered the basic minimums for quality expectations by Seminole County.
SITE SPECIFIC CONDITIONS: (General Requirements)
New home design and standard features:
Standard Features:
Air-conditioned space shall be approximately 1100 square feet, plus or minus 100 square feet. It shall have two (2) bedrooms and two 2 baths.
New home will have an attached one car garage. See Section .02 (Site Work) below.
Termite Protection: Shall be provided by a registered termiticide and comply with current FBC requirements. A certificate will be provided to the Permitting Jurisdiction at final inspection for issuance of C.O.
House will be designed with a hip roof.
Provide pre-manufactured truss system that shall cover (incorporate) the front porch. The trusses over the porch shall be supported by a structural header, wood posts or block columns at the front edge of the porch slab (Section .06).
See Supplemental Requirements for Garage/Utility Room specifications.
Exterior Requirements:
House to be centered on lot if conditions permit.
Home to be constructed on a stem wall foundation at a minimum of 4 courses (3 block and 1 chair). See Section .02 (Site Work) below.
ADA Accessibility required: Yes_X_ No___ If yes: The front porch needs to be raised up to within a ¼” of the finished floor for accessibility. The sidewalk from the porch to the driveway cannot exceed an 8% slope for accessibility purposes (see Section .03 below).
Front entry (porch): Front porch to be approximately 80 square feet and be included under roof (Section .03 below).
Rear patio slab to be approximately 8’ x 10’ (80 sq. ft.) and be included under roof see Section .03 below.
Provide a sliding glass door at the rear patio location.
Sub-fascia will be 6”.
House to be constructed with block exterior walls (Section .04 below)