Exhibit A - FINAL CDs - APPROVED-ALTC-2025-02674.pdf
PDF 7 MB Posted
- Attached to
- IFB 26-14 Town Hall Restrooms - Remodel
- Solicitation number
- IFB-122684
- Issued by
- Fairfax County, Virginia
About this file
This comprehensive set of construction documents pertains to the Town Hall Restroom Renovation project located at 127 Center Street South, Vienna, Virginia, under IFB 26-14, involving the City of Vienna and prepared by Bowman Consulting Group Ltd (architect) and supporting engineering firms. The project involves the renovation of six restrooms across three floors (basement, first floor, and second floor) of the Vienna Town Hall, with the scope encompassing new finishes, plumbing fixtures, lighting systems, and mechanical/electrical upgrades. The work includes demolition of existing fixtures and finishes, installation of new tile flooring, wall treatments, and bathroom accessories in three restroom areas: basement men's and women's restrooms (290.57 SF total), first floor gender-neutral and women's restrooms (194.67 SF combined), and second floor men's restroom with a redesignated family restroom (196.67 SF combined). The project addresses ADA accessibility requirements, including the re-designation of the second floor women's restroom as a family restroom with baby changing station to provide accessible facilities on that level. All fixtures and finishes are to be replaced in-kind, maintaining existing building occupancy, loads, and egress paths.
The construction documents include detailed architectural plans, demolition schedules, new work plans with reflected ceiling plans, interior elevations, electrical systems with motion-sensor lighting controls and LED fixtures, plumbing systems with fixture schedules and riser diagrams, and comprehensive specifications addressing materials, labor, equipment, and quality standards. Key requirements include coordination with MEP (mechanical, electrical, plumbing) drawings, protection of existing structures and finishes, field verification of dimensions, removal and proper disposal of construction debris, daily site cleanup, and compliance with all applicable codes and standards. The contractor is responsible for obtaining permits, managing inspections, and providing a one-year warranty on all materials and labor. Work must maintain normal building functions in adjacent occupied areas, with noise-producing and odor-producing activities scheduled during non-business hours by prior approval from building management.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
B ow m an
C on su lti ng G ro up
L td
W or ld ga te
D riv e
S ui te
H er nd on
, V A
P ho ne
3)
-0
F ax
3)
-9
LE
VE
LS
B
AS
EM
EN
T, ST
, 2 N
D
TO
W
N
HA
LL
B
AT
HR
O O
M R
EN
O
VA
TI
O N
PROJECT NO
140339-01-003
09.23.2025
FILE NO
bo w m an
.c om
B ow m an
C on su lti ng G ro up
L td
S:\Projects\Active\Vienna RR\CAD\SHEET SETS\sheets\CS00 VRR COVER.dwg
AS NOTED
2'
GRAPHIC SCALE: 1/4" = 1'-0"
4' 0' 4' 8'
C
EN
TE
R
S
TR
EE
T
SO
U
TH
VI
EN
N A, V
IR
G
IN
IA
GENERAL NOTES DRAWING INDEX ABBREVIATIONS
KEY PLAN
SYMBOLS AND LEGENDS
ADA ACCESSIBLE ROUTES VICINITY MAP
PROJECT SCOPE
QC BLOCK
MEP ENGINEER:
BOWMAN ENGINEERING
13461 SUNRISE VALLEY. STE 500
HERNDON, VA 20171
FAIRFAX COUNTY
FINAL SUBMITTAL
PROJECT #2305-01
VIENNA RESTROOM RENOVATION
127 CENTER STREET SOUTH,
VIENNA, VIRGINIA 22180
ARCHITECT:
PECK, PECK AND ASSOCS.
12506 LAKE RIDGE DRIVE SUITE C
WOODBRIDGE, VA 22192
1. THE CONTRACTOR IS RESPONSIBLE FOR BEING FAMILIAR WITH ALL DRAWINGS AND SPECIFICATIONS.
2. PRIOR TO BEGINNING OF WORK, THE CONTRACTOR SHALL VISIT THE SITE AND FULLY ACQUAINT HIMSELF WITH
CONDITIONS RELATING TO CONSTRUCTION, TO INCLUDE DIFFICULTIES AND RESTRICTIONS RELATED TO EXECUTION OF
THE WORK, AND EXISTING CONDITIONS.
3. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR SECURING ALL TRADE PERMITS AS REQUIRED FOR WORK HE IS TO PERFORM AND WILL OBTAIN AND PAY FOR ALL REQUIRED INSPECTIONS DURING THE DURATION OF THE WORK.
4. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS IN THE FIELD AND SHALL NOTIFY THE COUNTY PROJECT MANAGER OF ANY DISCREPANCIES, OMISSIONS AND / OR ANY OTHER CONFLICTS OR IRREGULARITIES PRIOR TO THE
COMMENCEMENT OF ANY WORK.
5. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN.
6. ALL DIMENSIONS SHOWN ARE TO THE FINISHED SIDE OF WORK.
7. CONTRACTOR SHALL NOT SUBSTITUTE MATERIALS AND/OR CONSTRUCTION ITEMS SPECIFIED UNLESS APPROVED BY THE
OWNER / CITY PROJECT MANAGER.
8. CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVAL AND DISPOSAL OF ALL CONSTRUCTION DEBRIS AND REFUSE
OFF-SITE IN A LEGAL MANNER.
9. PRIOR TO OCCUPANCY, CONTRACTOR SHALL BE RESPONSIBLE FOR: CLEANING ALL INTERIOR SURFACES, INCLUDING
GLASS SURFACES AND FLOOR SURFACES; REMOVAL OF ALL TRASH, CONST. DEBRIS AND TOOLS, ETC.
10. WORK NOT IN COMPLIANCE WITH THESE CONSTRUCTION DOCUMENTS SHALL BE CORRECTED AT THE CONTRACTOR'S
EXPENSE.
11. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN SAFE WORKING CONDITIONS AT ALL TIMES, INCLUDING BUT NOT
LIMITED TO APPROPRIATE TOOLS, EQUIPMENT, SCAFFOLDING, SHORING, ETC.
12. THE CONTRACTOR SHALL CLEAN UP DAILY TO KEEP THE PROJECT SITE CLEAN AND FREE FROM HAZARDS AT ALL TIMES.
UPON COMPLETION OF THE PROJECT THE CONTRACTOR SHALL REMOVE ALL TRASH AND DEBRIS, BROOM CLEAN THE
ENTIRE PROJECT AREA, AND LEAVE THE SITE IN A CLEAN CONDITION.
13. THE CONTRACTOR SHALL FIELD COORDINATE WITH THE MECHANICAL AND ELECTRICAL DRAWINGS FOR ALL RELATED
WORK REQUIRED BY THOSE TRADES.
14. THE WORDS "PROVIDE" AND "APPLY" INDICATE NEW WORK THAT WILL BE PROVIDED AND INSTALLED BY THE
CONTRACTOR.
15. ALL INSTALLATIONS SHALL BE PERFORMED WITHIN STRICT ACCORDANCE WITH THE MATERIAL, EQUIPMENT, AND/OR
APPLIANCE MANUFACTURER'S SPECIFICATIONS.
16. ALL DAMAGE TO EXISTING CONSTRUCTION AND PROPERTY RESULTING FROM DEMOLITION WORK, NEW WORK, OR OTHER ACTIONS OF THE CONTRACTOR SHALL BE PATCHED, PAINTED, AND REPAIRED WITH NEW MATERIALS TO MATCH
EXISTING ADJACENT CONSTRUCTION.
17. ALL CUTTING AND PATCHING SHALL BE PERFORMED IN A NEAT AND PROFESSIONAL MANNER. ANY EXISTING FINISHES DISTURBED OR DAMAGED BY THE CONTRACTOR DURING THE COURSE OF THE WORK SHALL BE PREPARED TO MATCH
EXISTING IN KIND AND FINISH.
18. NORMAL FUNCTIONS OF THE ADJACENT OCCUPIED AREAS MUST CONTINUE DURING THE CONSTRUCTION PHASES, EVERY EFFORT SHALL BE MADE TO ENSURE SUCH FUNCTIONS ARE NOT DISTURBED. SCHEDULE ANY WORK WHICH MAY BE REQUIRED IN OCCUPIED AREAS DURING UNOCCUPIED HOURS, AND OBTAIN PRIOR APPROVAL FROM THE OWNER.
19. NOISE PRODUCING WORK TO BE SCHEDULED WITH MANAGEMENT BEFORE 8 AM OR AFTER 6PM. PAINT, CARPET GLUE
AND OTHER ODOR PRODUCING WORK MUST BE SCHEDULED WITH MANAGEMENT FOR AFTER HOURS.
20. GC TO NOTIFY OWNER OF ANY EXISTING CONDITIONS THAT MAY CAUSE ISSUES WITH THE EXECUTION OF NEW WORK.
OBSERVE CONDITIONS OF ALL SUBSTRATES FOR CONDITION AND SUITABILITY TO ACCEPT NEW MATERIALS.
DEMOLITION NOTE
A1 A1
NUMBER INDICATES DETAIL
DETAIL
SHEET NUMBER WHERE DRAWN
SHEET NUMBER WHERE INDICATED
NUMBER INDICATES ELEVATION
INTERIOR ELEVATION
SHEET NUMBER WHERE DRAWN
SHEET NUMBER WHERE INDICATED
NUMBER INDICATES SECTION
SHEET NUMBER WHERE DRAWN
SHEET NUMBER WHERE INDICATED
A1 A1
A1 A1
DETAIL SECTION
PARTITION TYPE
NEW WORK NOTE#
WHEN MULTIPLE NEW WORK
NOTES ARE GROUPED, ALL
NOTES APPLY TO
ITEM/AREA INDICATED
ADA
ADJ.
AFF.
ANSI
AWG
AV
BLDG.
B.O.C.A.
CLG.
CLR.
COLR.
CONC.
CONST.
DEMO.
DBL.
EA.
EB.
EXIST.
EXT.
FOW
FRT
FSD
G.F.I.
GYP. BD.
HDWR.
HT.
H.M.
IBC
INFO.
INSUL.
ICC
LB
MAX.
MEP
MTL.
MIN.
MON.
N.
N.F.P.A.
NIC
N.T.S.
NO.
OCC.
O.C.
OFF
PTD.
PLAM.
P.
PR.
RCPT.
RENO.
REQ'D
R.C.P.
RCP
AMERICANS WITH DISABILITIES ACT
ADJUSTABLE
ABOVE FINISH FLOOR
AMERICAN NATIONAL STANDARDS INSTITUTE
AMERICAN WIRE GAUGE
AUDIO VISIUAL
BUILDING
BUILDING OFFICIALS AND CODE
CEILING
CLEAR
COLOR
CONCRETE
CONSTRUCTION
DEMOLITION
DOUBLE
EACH
EXISTING
EXTENSION
FACE OF WALL
FIRE RETARDANT TREATED
FIRE SEPARATION DISTANCE
GROUND FAULT INTERRUPTER
GYPSUM BOARD
HARDWARE
HEIGHT
HOLLOW METAL
INTERNATIONAL BUILDING CODE
INFORMATION
INSULATION
INTERNATIONAL CODE COUNCIL
MAXIMUM
MECHANICAL ELECTRICAL PLUMBING
METAL
MINIMUM
MONITORED
NORTH
NATIONAL FIRE PROTECTION ASSOCIATION
NOT IN CONTRACT
NOT TO SCALE
NUMBER
OCCUPANTS
ON CENTER
OFFICE
PAINTED
PLASTIC LAMINATE
PHASE
PAIR
RECEPTION
RENOVATION
REQUIRED
REFLECTED CEILING PLAN
REFLECTED CEILING PLAN
RM
RR
STO.
S.A.T
SF
SIM.
STRUCT.
THK
THRS.
T.B.D.
T.O.
TYP.
UL
U.N.O.
VDC
V.I.F.
VUSBC
W.
W/
ROOM
RESTROOM
STOREROOM
SUSPENDED ACOUSTIC TILE
SQUARE FEET
SIMILAR
STRUCTURE
THICK
THRESHOLD
TO BE DETERMINE
TOP OF
TYPICAL
UNDERLAYMENT
UNLESS NOTED OTHERWISE
VIRTUAL DESIGN & CONSTRUCTION
VERIFY IN FIELD
VIRGINIA UNIFORM
STATEWIDE BUILDING CODE
WIDTH
WITH
AGENCIES REFERENCED
UL UNDERWRITERS LABORATORIES INC
RAL RIVERBANK ACOUSTICAL LABORATORIES
CK CEDAR KNOLLS ACOUSTICAL LABORATORIES
USG UNITED STATES GYPSUM COMPANY
SA SHINER & ASSOCIATES
C00
GT VD
CO
VE
R
SH
EE
T
NTS
NEW PLUMBING FIXTURE AND
ACCESSORY
LEVEL 2 ALTERATION TO IMPROVE THE SANITARY AND SAFETY CONDITIONS OF THE 1ST
AND 2ND FLOOR RESTROOMS WITH THE ADDITION OF FLOOR DRAINS.
RESTROOMS IN THE BASEMENT (290.57 SF), 1ST (194.67 SF) AND 2ND FLOOR (196.67 SF)
SHALL RECEIVE NEW FINISHES, PLUMBING AND LIGHTING FIXTURES. ALL FIXTURES AND
FINISHES WILL BE REPLACED IN-KIND.
IT IS TECHNICALLY INFEASIBLE TO MODIFY THE MEN'S RESTROOM ON THE 2ND FLOOR TO
PROVIDE AN ACCESSIBLE WATER CLOSET. THEREFORE TO PROVIDE AN ACCESSIBLE
TOILET TO ALL SEXES ON THIS LEVEL, THE EXISTING 2ND FLOOR WOMEN'S RESTROOM
SHALL BE RE-DESIGNATED AS A FAMILY RESTROOM WITH THE ADDITION OF A BABY
CHANGING STATION.
EXISTING BUILDING USE, OCCUPANT LOAD, AND EGRESS PATHS SHALL REMAIN THE SAME.
z 5/13/2026
ALTC-2025-02674
C O
D E
D A
TA
GT VD
G00
B ow m an
C on su lti ng G ro up
L td
W or ld ga te
D riv e
S ui te
H er nd on
, V A
P ho ne
3)
-0
F ax
3)
-9
LE
VE
LS
B
AS
EM
EN
T, ST
, 2 N
D
TO
W
N
HA
LL
B
AT
HR
O O
M R
EN
O
VA
TI
O N
PROJECT NO
140339-01-003
09.23.2025
FILE NO
bo w m an
.c om
B ow m an
C on su lti ng G ro up
L td
AS NOTED
2'
GRAPHIC SCALE: 1/4" = 1'-0"
4' 0' 4' 8'
C
EN
TE
R
S
TR
EE
T
SO
U
TH
VI
EN
N A, V
IR
G
IN
IA
2026 02 17
1ST FLOOR PLAN
1/8" = 1'-0" G00G00
BASEMENT FLOOR PLAN
1/8" = 1'-0" G00G00
2ND FLOOR PLAN
1/8" = 1'-0" G00G00
PROJECT AREA
PROJECT
AREA
PROJECT AREA
BUILDING DATA / CODE DATA DESIGN NARRATIVE
LEVEL 2 ALTERATION TO IMPROVE THE SANITARY AND SAFETY CONDITIONS OF
THE 1ST AND 2ND FLOOR RESTROOMS WITH THE ADDITION OF FLOOR DRAINS.
RESTROOMS IN THE BASEMENT (290.57 SF), 1ST (194.67 SF) AND 2ND FLOOR
(196.67 SF) SHALL RECEIVE NEW FINISHES, PLUMBING AND LIGHTING FIXTURES.
ALL FIXTURES AND FINISHES WILL BE REPLACED IN-KIND.
IT IS TECHNICALLY INFEASIBLE TO MODIFY THE MEN'S RESTROOM ON THE 2ND
FLOOR TO PROVIDE AN ACCESSIBLE WATER CLOSET. THEREFORE TO PROVIDE AN
ACCESSIBLE TOILET TO ALL SEXES ON THIS LEVEL, THE EXISTING 2ND FLOOR
WOMEN'S RESTROOM SHALL BE RE-DESIGNATED AS A FAMILY RESTROOM WITH
THE ADDITION OF A BABY CHANGING STATION.
EXISTING BUILDING USE, OCCUPANT LOAD, AND EGRESS PATHS SHALL REMAIN THE
SAME.
BW
WOMEN'S RESTROOMBM
MEN'S RESTROOM
1GN
TOILET ROOM
1W
WOMEN'S RESTROOM
2F
TOILET ROOM
2M
MEN'S RESTROOM
DOOR HARDWARE NOTES
1. ALL DOOR HARDWARE EXISTING TO REMAIN.
2. ALL DOORS TO HAVE FREE EGRESS AT ALL TIMES.
3. ROOMS BM, BW, 1GN, 1W, 2M: ADA ACCESSIBLE LEVER WITH THUMBTURN ON
INTERIOR AND KEYED LOCK ON EXTERIOR. FREE EGRESS AT ALL TIMES. 3 PR
HINGES, KICKPLATE ON EXTERIOR.
4. ROOM 2F: ADA ACCESSIBLE LEVER WITH PUSH BUTTON ON INTERIOR AND KEYED
LOCK ON EXTERIOR. FREE EGRESS AT ALL TIMES. 3 PR HINGES, KICKPLATE ON
EXTERIOR.
INTERIOR FINISHES
BUSINESS
EXIT ENCLOSURES &
PASSAGEWAYS
CORRIDORS
ROOMS & ENCLOSED SPACES
CLASS A
CLASS B
CLASS C
2 2 z 5/13/2026
ALTC-2025-02674
AutoCAD SHX Text
SHEET
AutoCAD SHX Text FILE No.
AutoCAD SHX Text
OF
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
DATE :
AutoCAD SHX Text JOB No.
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
DESIGN
AutoCAD SHX Text
DATE
AutoCAD SHX Text
CHKD
AutoCAD SHX Text
PLAN STATUS
AutoCAD SHX Text
COUNTY PROJECT NUMBER
AutoCAD SHX Text Cad file name :
AutoCAD SHX Text
7'-21 2"
7'-71 2"
6'-11"
7'-1"
7'-41 2"
6'-10"
BASEMENT
MEN & WOMEN DEMOLITION PLAN
1/4=1'-0" A01A01
A01
B ow m an
C on su lti ng G ro up
L td
W or ld ga te
D riv e
S ui te
H er nd on
, V A
P ho ne
3)
-0
F ax
3)
-9
LE
VE
LS
B
AS
EM
EN
T, ST
, 2 N
D
TO
W
N
HA
LL
B
AT
HR
O O
M R
EN
O
VA
TI
O N
PROJECT NO
140339-01-003
09.23.2025
FILE NO
bo w m an
.c om
B ow m an
C on su lti ng G ro up
L td
S:\Projects\Active\Vienna RR\CAD\SHEET SETS\sheets\A01 BASEMENT DEMO PLN & RCP.dwg
AS NOTED
2'
GRAPHIC SCALE: 1/4" = 1'-0"
4' 0' 4' 8'
C
EN
TE
R
S
TR
EE
T
SO
U
TH
VI
EN
N A, V
IR
G
IN
IA
BASEMENT
MEN & WOMEN DEMOLITION REFLECTED CEILING PLAN
1/4=1'-0" A01A01
GRAPHIC SCALE
2 0 2' 4' 8
1/4" = 1'-0"
KEY PLAN
GENERAL NOTES
1. DEDUCT 1: DEDUCT ALL DEMOLITION WORK FROM BASE BID FOR WOMEN &
MEN'S BASEMENT LEVEL RESTROOMS.
2. COORDINATE WITH MEP DRAWINGS FOR FULL EXTENT OF NEW WORK.
3. PROTECT EDGES OF EXISTING FLOOR FINISHES FROM DAMAGE UNTIL NEW
FLOORING AND TRANSITION STRIPS ARE INSTALLED.
4. EXISTING GRAB BARS IN ACCESSIBLE STALLS SHALL BE REMOVED AND
STORED FOR REINSTALLATION.
5. EXISTING SAT GRID SHALL REMAIN.
6. EXISTING SPRINKLER HEADS ARE EXISTING TO REMAIN AND SHALL BE
PROTECTED DURING ALL PHASES OF CONSTRUCTION. COORDINATE WITH
OWNER REGARDING FIRE WATCH REQUIREMENTS.
7. ALL DIMENSIONS SHALL BE FIELD VERIFIED.
9. NOT ALL KEYNOTES APPLY TO EVERY SHEET.
10. REMOVE AREA OF CEILING AS REQUIRED TO INSTALL NEW PIPING FOR
FLOOR DRAINS OF THE SUBSEQUENT FLOOR LEVEL.
LEGEND
PARTITION
DEMOLITION KEY NOTE#
2 X 2 SAT GRID
2 X 4 LIGHT FIXTURE
2 X 2 CEILING DIFFUSER
1 X 4 LIGHT FIXTURE & EGG CRATE
LIGHT DIFFUSER
12 X 6 EXHAUST GRILLE
THERMO DETECTOR
EXISTING
TO REMAINDEMO
TOILET PARTITION
DEMOLITION KEY NOTES
PROJECT
AREA
REMOVE MIRROR, LAMINATE COUNTERS, (2) SURFACE MOUNTED SOAP
DISPENSERS FROM THE MEN'S ROOM ,AND (2) SURFACE MOUNTED SOAP
DISPENSERS FROM THE WOMEN'S ROOM.
REMOVE TOILET SEAT COVER DISPENSER, STORE FOR
REINSTALLATION.3
REMOVE TOILET PAPER DISPENSER AND SANITARY
WASTE RECEPTACLE.4
REMOVE RECESSED PAPER TOWEL DISPENSER / TRASH
RECEPTACLE.5
REMOVE PAPER TOWEL DISPENSER, STORE FOR
REINSTALLATION.6
REMOVE TOILETS, URINALS AND ALL ASSOCIATED
PARTS. CAP ALL PIPING.
7 7
WOMEN'S RESTROOM
BW
WOMEN'S RESTROOM
BM
MEN'S RESTROOM
BM
MEN'S RESTROOM
REMOVE EGG CRATE LOUVER AND FLUORESCENT LUMINARIES IN LIGHT
COVE. EXISTING GYP. BD. BULKHEAD SHALL REMAIN.
BW
GT VD
BS
M
T D
EM
O P
LA
N
RC
P
ROOM NAME AND NUMBERXXX
XXX
RETAIN THERMO DETECTOR, STORE FOR
REINSTALLATION.
FILLING STATION / DRINKING FOUNTAIN
REMOVE SAT CEILING TILES AS INDICATED BY:
CEILING GRID SHALL REMAIN.
REMOVE ALL VERTICAL AREAS OF SAT CEILING IN LOCATIONS
WHERE THERE IS A CEILING HEIGHT CHANGE.
REMOVE TILE FLOOR AND ENTRY THRESHOLDS AS DESIGNATED BY:
INCLUDING AREAS UNDER ALL FIXTURES AND ACCESSORIES. REMOVE WALL
TILE +/- 4'-6" AFF ALONG ENTIRE PERIMETER OF RESTROOM.
REMOVE LIGHT FIXTURES AS DESIGNATED BY THE LEGEND. REFER TO
MEP DRAWINGS FOR MORE INFORMATION.
REMOVE TOILET PARTITIONS AND ALL ASSOCIATED
HARDWARE.
12 12
2 X 2 SAT CEILING TILE
'-8
"-V .I.F
16'-3 1/2"-V.I.F.
'-8
"-V .I.F
16'-3 1/2"-V.I.F.
z
T
7'-11" 7'-9"
1ST FLOOR
WOMEN'S DEMOLITION PLAN
1/4=1'-0" A02A02
B ow m an
C on su lti ng G ro up
L td
W or ld ga te
D riv e
S ui te
H er nd on
, V A
P ho ne
3)
-0
F ax
3)
-9
LE
VE
LS
B
AS
EM
EN
T, ST
, 2 N
D
TO
W
N
HA
LL
B
AT
HR
O O
M R
EN
O
VA
TI
O N
PROJECT NO
140339-01-003
09.23.2025
FILE NO
bo w m an
.c om
B ow m an
C on su lti ng G ro up
L td
S:\Projects\Active\Vienna RR\CAD\SHEET SETS\sheets\A02 1ST FLOOR DEMO PLN & RCP.dwg
AS NOTED
2'
GRAPHIC SCALE: 1/4" = 1'-0"
4' 0' 4' 8'
C
EN
TE
R
S
TR
EE
T
SO
U
TH
VI
EN
N A, V
IR
G
IN
IA
GRAPHIC SCALE
2 0 2' 4' 8
1/4" = 1'-0"
KEY PLAN
GENERAL NOTES
LEGEND
PARTITION
DEMOLITION KEY NOTE#
1 X 4 SURFACE MOUNTED LIGHT FIXTURE
2 X 2 CEILING DIFFUSER
1 X 4 WALL MOUNTED LIGHT FIXTURE
12 X 6 EXHAUST GRILLE
EXISTING TO REMAINDEMO
TOILET PARTITION
DEMOLITION KEY NOTES
NTS
PROJECT
AREA
1ST FLOOR
WOMEN'S DEMOLITION RCP
1/4=1'-0" A02A02
1ST FLOOR
TOILET ROOM DEMO PLAN
1/4=1'-0" A02A02
1ST FLOOR
TOILET ROOM DEMO RCP
1/4=1'-0" A02A02
REMOVE TILE FLOOR AND ENTRY THRESHOLDS AS INDICATED BY:
INCLUDING AREAS UNDER FIXTURES AND ACCESSORIES. REMOVE
WALL TILE +/- 4'-6" AFF ALONG ENTIRE PERIMETER OF RESTROOM.
REMOVE MIRROR, LAMINATE COUNTERS, AND
LAVATORIES.
REMOVE TOILET PAPER DISPENSER AND SANITARY
WASTE RECEPTACLE, STORE FOR REINSTALLATION.4
REMOVE RECESSED PAPER TOWEL DISPENSER / TRASH
RECEPTACLE.5
REMOVE PAPER TOWEL DISPENSER, STORE FOR
REINSTALLATION.6
REMOVE TOILET SEAT COVER DISPENSER.
A02
GT VD
1S T F
L D
EM
O P
LA
N
RC
P
1. COORDINATE WITH MEP DRAWINGS FOR FULL EXTENT OF NEW WORK.
2. PROTECT EDGES OF EXISTING FLOOR FINISHES FROM DAMAGE UNTIL NEW
FLOORING AND TRANSITION STRIPS ARE INSTALLED.
4. EXISTING GRAB BARS IN ACCESSIBLE TOILETS SHALL BE REMOVED AND
STORED FOR REINSTALLATION.
5. EXISTING GYPSUM BOARD CEILING REMAIN.
6. EXISTING SPRINKLER HEADS ARE EXISTING TO REMAIN AND SHALL BE
PROTECTED DURING ALL PHASES OF CONSTRUCTION. COORDINATE WITH
OWNER REGARDING FIRE WATCH REQUIREMENTS.
7. ALL DIMENSIONS SHALL BE FIELD VERIFIED.
8. EXISTING THERMOSTAT AND WIRE MOLD SHALL BE REMOVED AND STORED
FOR REINSTALLATION.
9. NOT ALL KEYNOTES APPLY TO EVERY SHEET.
T
MECHANICAL UNIT
THERMOSTAT @ 5' AFF
1GN
TOILET ROOM1W
WOMEN'S RESTROOM
1GN
TOILET ROOM
1W
WOMEN'S RESTROOM
GYPSUM BOARD CEILING
REMOVE WALL HUNG LAVATORY, FAUCET, MIRROR
AND ALL ASSOCIATED PARTS.7
2 X 2 CEILING RETURN
ROOM NAME AND NUMBERXXX
XXX
HIGH / LOW DRINKING FOUNTAIN
REMOVE AND STORE (2) SURFACE MOUNTED SOAP DISPENSERS FROM
WOMEN'S ROOM, (1) FROM TOILET ROOM, AND FAUCETS FOR
REINSTALLATION.
8 9
REMOVE TOILETS AND URINALS. REMOVE AND STORE
TOILET AND URINAL FLUSH VALVES FOR
REINSTALLATION.
5'-9"
1'- 6"
REMOVE PORTION OF EXISTING CONCRETE SLAB AS INDICATED
BY: FOR INSTALLATION OF NEW PLUMBING
DRAINS. AREAS OF REMOVAL ARE APPROXIMATE. EXISTING
CONSTRUCTION ASSUMED TO BE 2 12"CONCRETE SLAB ON
CORRUGATE METAL SHEET PER EXISTING DRAWINGS. REFER TO
MEP DRAWINGS FOR MORE INFORMATION.
2'-11"
1'- 6"
REMOVE LIGHT FIXTURES AS DESIGNATED BY THE
LEGEND. REFER TO MEP DRAWINGS FOR MORE
INFORMATION.
2 X 4 SURFACE MOUNTED LIGHT FIXTURE
REMOVE TOILET PARTITION AND ALL ASSOCIATED
HARDWARE.
12'-6 1/2"-V.I.F.
9'- 9 1
/2 "-V
.I.F
6'-7"-V.I.F.
9'- 9"
-V .I.F
12'-6 1/2"-V.I.F.
9'- 9 1
/2 "-V
.I.F
6'-7"-V.I.F.
9'- 9"
-V .I.F z
7'-91
7'-111 2"
T
2ND FLOOR
WOMEN'S DEMOLITION PLAN
1/4=1'-0" A03A03
B ow m an
C on su lti ng G ro up
L td
W or ld ga te
D riv e
S ui te
H er nd on
, V A
P ho ne
3)
-0
F ax
3)
-9
LE
VE
LS
B
AS
EM
EN
T, ST
, 2 N
D
TO
W
N
HA
LL
B
AT
HR
O O
M R
EN
O
VA
TI
O N
PROJECT NO
140339-01-003
09.23.2025
FILE NO
bo w m an
.c om
B ow m an
C on su lti ng G ro up
L td
S:\Projects\Active\Vienna RR\CAD\SHEET SETS\sheets\A03 2ND FLOOR DEMO PLN & RCP.dwg
AS NOTED
2'
GRAPHIC SCALE: 1/4" = 1'-0"
4' 0' 4' 8'
C
EN
TE
R
S
TR
EE
T
SO
U
TH
VI
EN
N A, V
IR
G
IN
IA
GRAPHIC SCALE
2 0 2' 4' 8
1/4" = 1'-0"
KEY PLAN
GENERAL NOTES
LEGEND
PARTITION
DEMOLITION KEY NOTE#
GYPSUM BOARD CEILING
1 X 4 SURFACE MOUNTED LIGHT FIXTURE
2 X 2 CEILING DIFFUSER
12 X 6 EXHAUST GRILLE
EXISTING TO REMAINDEMO
TOILET PARTITION
DEMOLITION KEY NOTES
NTS
PROJECT
AREA
2ND FLOOR
WOMEN'S DEMO RCP
1/4=1'-0" A03A03
2ND FLOOR
MEN'S DEMOLITION PLAN
1/4=1'-0" A03A03
2ND FLOOR
MEN'S DEMO RCP
1/4=1'-0" A03A03
A03
GT VD
2N D
FL
D
EM
O
P
LA
N
RC
P
1. DEDUCT 2: DEDUCT ALL DEMOLITION WORK FROM BASE BID FOR WOMEN
& MEN'S 2ND FLOOR RESTROOMS.
2. COORDINATE WITH MEP DRAWINGS FOR FULL EXTENT OF NEW WORK.
3. PROTECT EDGES OF EXISTING FLOOR FINISHES FROM DAMAGE UNTIL NEW
FLOORING AND TRANSITION STRIPS ARE INSTALLED.
4. EXISTING GRAB BARS IN ACCESSIBLE STALLS SHALL BE REMOVED AND
STORED FOR REINSTALLATION.
5. EXISTING GYPSUM BOARD CEILING REMAIN.
6. EXISTING SPRINKLER HEADS ARE EXISTING TO REMAIN AND SHALL BE
PROTECTED DURING ALL PHASES OF CONSTRUCTION. COORDINATE WITH
OWNER REGARDING FIRE WATCH REQUIREMENTS.
7. ALL DIMENSIONS SHALL BE FIELD VERIFIED.
8. PROVIDE SCHLUTER S1 ON ALL EXPOSED EDGES OF TILE.
9. EXISTING THERMOSTAT AND WIRE MOLD SHALL BE REMOVED AND STORED
FOR REINSTALLATION.
9. NOT ALL KEYNOTES APPLY TO EVERY SHEET.
10. REMOVE AREA OF CEILING AS REQUIRED TO INSTALL NEW PIPING FOR
FLOOR DRAINS OF THE SUBSEQUENT FLOOR LEVEL.
REMOVE TILE FLOOR AND ENTRY THRESHOLDS AS DESIGNATED BY:
INCLUDING AREAS UNDER FIXTURES AND ACCESSORIES. REMOVE
WALL TILE +/- 4'-6" AFF ALONG ENTIRE PERIMETER OF RESTROOM.
6 5
T
MECHANICAL UNIT
THERMOSTAT @ 5' AFF
2M
WOMEN'S RESTROOM 2M
MEN'S RESTROOM
XXX
XXX
2M
WOMEN'S RESTROOM
2M
MEN'S RESTROOM
ROOM NAME AND NUMBER
ROOF HATCH
REMOVE MIRROR, LAMINATE COUNTERS, AND
LAVATORY SINK.
REMOVE TOILET PAPER DISPENSER AND SANITARY
WASTE RECEPTACLE, STORE FOR REINSTALLATION.4
REMOVE RECESSED PAPER TOWEL DISPENSER / TRASH
RECEPTACLE.5
REMOVE SURFACE MOUNTED PAPER TOWEL
DISPENSER, STORE FOR REINSTALLATION.6
REMOVE TOILET SEAT COVER DISPENSER.
REMOVE PEDESTAL LAVATORY, MIRROR AND ALL
ASSOCIATED PARTS.7
8 REMOVE AND STORE (1) SURFACE MOUNTED SOAP DISPENSERS FROM
MEN'S RR, (1) FROM WOMEN'S RR, AND FAUCETS FOR REINSTALLATION.
REMOVE TOILETS AND URINALS. REMOVE AND STORE
TOILET AND URINAL FLUSH VALVES FOR
REINSTALLATION.
REMOVE TOILET PAPER DISPENSER AND STORE FOR
REINSTALLATION.10
5'-9"9
1'- 6"
2'-11" 1'- 6"
REMOVE AND STORE ROOF HATCH LADDER FOR
REINSTALLATION.
REMOVE LIGHT FIXTURES AS INDICATED, REFER TO
LEGEND FOR MORE INFORMATION.
13 13
REMOVE WOMEN'S RESTROOM SIGN.14
REMOVE TOILET PARTITION AND ALL ASSOCIATED
HARDWARE.
REMOVE PORTION OF EXISTING CONCRETE SLAB AS INDICATED
BY: FOR INSTALLATION OF NEW PLUMBING
DRAINS. AREAS OF REMOVAL ARE APPROXIMATE. EXISTING
CONSTRUCTION ASSUMED TO BE 2 12"CONCRETE SLAB ON
CORRUGATE METAL SHEET PER EXISTING DRAWINGS. REFER TO
MEP DRAWINGS FOR MORE INFORMATION.
6'-4 1/2"-V.I.F.
9'- 8 1
/2 "-V
.I.F
14'-6"-V.I.F.
'-2
1/ 2"
-V .I.F
6'-4 1/2"-V.I.F.
9'- 8 1
/2 "-V
.I.F
14'-6"-V.I.F.
'-2
1/ 2"
-V .I.F z
7'-21
7'-71 2"
6'-11"
7'-1"
7'-41 2"
6'-10"
BASEMENT
MEN & WOMEN RR NEW WORK PLAN
1/4=1'-0" A04A04
B ow m an
C on su lti ng G ro up
L td
W or ld ga te
D riv e
S ui te
H er nd on
, V A
P ho ne
3)
-0
F ax
3)
-9
LE
VE
LS
B
AS
EM
EN
T, ST
, 2 N
D
TO
W
N
HA
LL
B
AT
HR
O O
M R
EN
O
VA
TI
O N
PROJECT NO
140339-01-003
09.23.2025
FILE NO
bo w m an
.c om
B ow m an
C on su lti ng G ro up
L td
S:\Projects\Active\Vienna RR\CAD\SHEET SETS\sheets\A04 BASEMENT NEW WORK PLN & RCP.dwg
AS NOTED
2'
GRAPHIC SCALE: 1/4" = 1'-0"
4' 0' 4' 8'
C
EN
TE
R
S
TR
EE
T
SO
U
TH
VI
EN
N A, V
IR
G
IN
IA
GRAPHIC SCALE
2 0 2' 4' 8
1/4" = 1'-0"
KEY PLAN
GENERAL NOTES
1. DEDUCT 1: DEDUCT ALL WORK FROM BASE BID FOR WOMEN & MEN'S BASEMENT
LEVEL RESTROOMS.
2. PROVIDE NEW PLUMBING FIXTURES, COORDINATE WITH MEP DRAWINGS FOR FULL
EXTENT OF NEW WORK.
3. PROTECT EDGES OF EXISTING FLOOR FINISHES FROM DAMAGE UNTIL NEW
FLOORING AND TRANSITION STRIPS ARE INSTALLED.
4. REFER TO INTERIOR ELEVATIONS FOR MORE INFORMATION.
5. PROVIDE NEW TOILET PARTITIONS. REFER TO COLOR SCHEDULE FOR MORE
INFORMATION.
6. PROVIDE TOILET ACCESSORIES, REFER TO FIXTURE SCHEDULE ON A07 FOR MORE
INFORMATION.
7. PAINT DIFFUSER AND RETURN GRILLES WITH P4
8. ALL EXISTING DOORS, HARDWARE AND FRAMES SHALL REMAIN.
9. REFER TO COLOR SCHEDULE AND FINISH SCHEDULE.
10. ALL DIMENSIONS SHALL BE FIELD VERIFIED.
11. PROVIDE SCHLUTER S1 ON ALL EXPOSED OUTSIDE CORNERS OF TILE.
14. REPLACE ALL EXISTING WALL MOUNTED 9"X9"ACCESS PANELS IN-KIND. ALL ACCESS
PANELS SHALL BE WHITE AND LOCKEABLE. FLUSH MOUNT WITH TILE.
15. PATCH AND PREPARE EXISTING WALL TO RECEIVE NEW WALL TILE.
16. PROVIDE TRANSITION, DOUBLE BEVELED, THRESHOLDS AT ALL RESTROOM ENTRIES.
CHANGES IN LEVEL BETWEEN 14" HIGH MINIMUM AND 12" HIGH MAXIMUMS SHALL BE
BEVELED WITH A SLOPE NOT STEEPER THAN 1:2.
LEGEND
PARTITION
NEW WORK KEY NOTE
2X4 LED LIGHT FIXTURE
2 X 2 CEILING DIFFUSER
12 X 6 EXHAUST GRILLE
EXISTING
TO REMAIN
TOILET PARTITION
KEY NOTES
NTS
PROJECT
AREA
BASEMENT
MEN & WOMEN RR NEW REFLECTED CEILING PLAN
1/4=1'-0" A04A04
BASEMENT
MEN'S RR NEW WORK ELEVATIONS
3/8"=1'-0" 3/A041/A04
BASEMENT
WOMEN'S RR NEW WORK ELEVATIONS
3/8"=1'-0" 4/A041/A04
FINISH SCHEDULE
XXX ROOM NAME AND NUMBERXXX
BW
WOMEN'S RESTROOM
B
A
NEW
WORK
2X2 CEILING RETURN
BW
WOMEN'S RESTROOM
BM
MEN'S RESTROOM
BM
MEN'S RESTROOM
1X4 WALL MOUNTED LED LIGHT FIXTURE
B
A
PREP CONCRETE TO RECEIVE NEW FINISHES. INSTALL FLOOR TILE T1.
PROVIDE NEW MIRROR M1, LAVATORY SINKS AND SOLID SURFACE
COUNTERS L1. REINSTALL SURFACE MOUNTED SOAP DISPENSER
TA3, AND FAUCETS. REFER TO INTERIOR ELEVATIONS ON A&B /A04
AND MEP DRAWINGS FOR MORE INFORMATION.
3 INSTALL TOILET SEAT COVER DISPENSER TS1.
REINSTALL SURFACE MOUNTED PAPER TOWEL
DISPENSER TA4.
NOT USED
PROVIDE NEW CEILING TILES C1 AND LED LIGHT
FIXTURES. REFER TO MEP FOR MORE INFORMATION.
1 1
3 3
4 4
5 5
XXX PLUMBING FIXTURE / ACCESSORY
7 PAINT BULKHEAD AND LIGHT COVE WITH P3.
ROOM NAMEROOM #
MEN'S
RESTROOMBM
FLOOR BASE CEILING
TILE
CLNG HEIGHT
T1
BASE
T2
SAT CEILING
TILES
C1/PNT
VARIES
COMMENTS
NORTH WALL SOUTH WALL EAST WALL WEST WALL
TILE/PAINT TILE/PAINT TILE/PAINT TILE/PAINT
ROOM NAMEROOM #
WOMEN'S
RESTROOMBW
FLOOR BASE CEILING
TILE
CLNG HEIGHT
T1
BASE
T2
VARIES
COMMENTS
NORTH WALL SOUTH WALL EAST WALL WEST WALL
TILE/PAINT TILE/PAINT TILE/PAINT TILE/PAINT
SEE ELEVATION T3/ P1
A04
GT VD
BS
M
T N W
W O
RK
P
LN
EL
EV
A
B
A
TA1
B
THERMO DETECTOR
FILLING STATION / DRINKING FOUNTAIN
2' 2'0 4'
3/8" = 1'-0"
REINSTALL SURFACE MOUNTED SANITARY NAPKIN
DISPOSAL TA2.
SAT CEILING TILES
A04 A07
A04 A07
SEE ELEVATION
10 PROVIDE T3 AS FIELD TILE , INSTALLED HORIZONTALLY.
11 PROVIDE ACCENT TILE T6, INSTALLED VERTICALLY,
CENTERED ON FIXTURE.
12 PROVIDE ACCENT TILE T5, INSTALLED VERTICALLY
CENTERED ON FIXTURE.
TYP.
TYP.
TYP.
TYP.
13 PROVIDE SCHLUTER S2 AS COVE TRIM ALONG ENTIRE
PERIMETER.
14 PROVIDE ACCENT TILE T4 ABOVE COUNTER.
TYP.
TYP.
TYP. 10
TYP.
T1 T1 T1U1U1
F1 F2
F3
TS1 TS1
TS1
F1 F2
M1
15 16
15 PROVIDE 3'-10" WIDE X 2'-6" HIGH, CUSTOM SHEET MIRROR M1.
INSTALLED CENTERED OVER COUNTER AT 3'-4" AFF.
16 PROVIDE 5'-0" WIDE X 2'-6" HIGH, CUSTOM SHEET MIRROR M1.
INSTALLED CENTERED OVER COUNTER AT 3'-4" AFF.
M1
TA1 TA1TA2
F3
TA1 L1 L1L1 L1
T3/ P1 T3/ P1
T3/ P1 T3/ P1 T3/ P1
SAT CEILING
TILES
C1/PNT
GYPSUM BOARD CEILING / BULKHEAD
INFILL PARTITION USING METAL STUDS @ 16" O.C. AND GYP. BD. WHERE
RECESSED PAPER TOWEL DISPENSER/ TRASH RECEPTACLE HAS BEEN
REMOVED. ALIGN INFILL WITH OUTER FACE OF EXISTING PARTITION.
TYP.
TYP.
TA1
F1
F2
F1
F2 6'-
8 3 /4
19'-8 3/16"
7'-10 1/2"
6'-
6 3
/4
7'-10 1/2"
6'-
6 3
/4
7'- 1"
19'-8 3/16"
Ø60" TYP.
ADA TURNING RADIUS @ 60"
z
7'-9"7'-9"7'-9"
7'-11"7'-11"7'-11"
TTT
METALBATHROOM SINK FAUCETCORALAISK-15182-4RA
1ST FLOOR
TOILET ROOM NEW WORK PLAN
1/4=1'-0" A05A05
B ow m an
C on su lti ng G ro up
L td
W or ld ga te
D riv e
S ui te
H er nd on
, V A
P ho ne
3)
-0
F ax
3)
-9
LE
VE
LS
B
AS
EM
EN
T, ST
, 2 N
D
TO
W
N
HA
LL
B
AT
HR
O O
M R
EN
O
VA
TI
O N
PROJECT NO
140339-01-003
09.23.2025
FILE NO
bo w m an
.c om
B ow m an
C on su lti ng G ro up
L td
S:\Projects\Active\Vienna RR\CAD\SHEET SETS\sheets\A05 1ST FLOOR NEW WORK PLN & RCP.dwg
AS NOTED
2'
GRAPHIC SCALE: 1/4" = 1'-0"
4' 0' 4' 8'
C
EN
TE
R
S
TR
EE
T
SO
U
TH
VI
EN
N A, V
IR
G
IN
IA
KEY PLAN
NTS
1ST FLOOR
TOILET ROOM RCP
1/4=1'-0" A05A05
1ST FLOOR
WOMEN'S RR NEW WORK PLAN
1/4=1'-0" A05A05
1ST FLOOR
WOMEN'S RR NEW WORK RCP
1/4=1'-0" A05A05
B
A
1ST FLOOR
TOILET ROOM NEW WORK ELEVATIONS
3/8"=1'-0" 3A051/A05
1ST FLOOR
WOMEN'S RR NEW WORK ELEVATIONS
3/8"1'-0" 4/A052/A05
1GN
TOILET ROOM
1W
WOMEN'S RESTROOM
1GN
TOILET ROOM
C
A
1W
WOMEN'S RESTROOM
GRAPHIC SCALE
2 0 2' 4' 8
1/4" = 1'-0"
KEY PLAN
GENERAL NOTES
1. PROVIDE NEW PLUMBING FIXTURES, COORDINATE WITH MEP DRAWINGS FOR FULL
EXTENT OF NEW WORK.
2. PROTECT EDGES OF EXISTING FLOOR FINISHES FROM DAMAGE UNTIL NEW
FLOORING AND TRANSITION STRIPS ARE INSTALLED.
3. REFER TO INTERIOR ELEVATIONS FOR MORE INFORMATION.
4. PROVIDE NEW TOILET PARTITIONS. REFER TO COLOR SCHEDULE FOR MORE
INFORMATION.
5. PROVIDE TOILET ACCESSORIES, REFER TO FIXTURE SCHEDULE ON A07 FOR MORE
INFORMATION.
6. PAINT ALL DIFFUSER AND RETURN GRILLES WITH P4.
7. ALL EXISTING DOORS, HARDWARE AND FRAMES SHALL REMAIN.
8. ALL DIMENSIONS SHALL BE FIELD VERIFIED.
9. DOORS AND FRAMES SHALL ONLY RECEIVE PAINT ON THE INTERIOR SIDE OF THE
RESTROOMS.
10. PROVIDE SCHLUTER S1 ON ALL EXPOSED OUTSIDE CORNERS.
13. REFER TO COLOR SCHEDULE AND FINISH SCHEDULE.
14. REINSTALL EXISTING THERMOSTAT AND WIRE MOLD.
14. REPLACE ALL EXISTING WALL MOUNTED 9"X9"ACCESS PANELS IN-KIND. ALL
ACCESS PANELS SHALL BE WHITE AND LOCKABLE. FLUSH MOUNT WITH TILE.
15. PATCH AND PREPARE EXISTING WALL TO RECEIVE NEW WALL TILE.
16. PROVIDE TRANSITION, DOUBLE BEVELED, THRESHOLDS AT ALL RESTROOM ENTRIES.
CHANGES IN LEVEL BETWEEN 14" HIGH MINIMUM AND 12" HIGH MAXIMUMS SHALL BE
BEVELED WITH A SLOPE NOT STEEPER THAN 1:2.
LEGEND
PARTITION
NEW WORK KEY NOTE
2X4 LED LIGHT FIXTURE
2 X 2 CEILING DIFFUSER
12 X 6 EXHAUST GRILLE
EXISTING
TO REMAIN
TOILET PARTITION
KEY NOTES
PROJECT
AREA
FINISH SCHEDULE XXX ROOM NAME AND NUMBERXXX
NEW
WORK
2X2 CEILING RETURN
1X4 WALL MOUNTED LED LIGHT FIXTURE
XXX PLUMBING FIXTURE / ACCESSORY
ROOM NAMEROOM #
GENDER
NEUTRAL RR1GN
FLOOR BASE CEILING
TILE
CLNG HEIGHT
T1
BASE
B1
EXIST. GYP
TO REMAIN
P3 7'-9"
COMMENTS
NORTH WALL SOUTH WALL EAST WALL WEST WALL
TILE TILE TILE TILE
ROOM NAMEROOM #
WOMEN'S
RESTROOM1W
FLOOR BASE CEILING
TILE
CLNG HEIGHT
T1
BASE
B1 7'-11"
COMMENTS
NORTH WALL SOUTH WALL EAST WALL WEST WALL
TILE TILE TILE TILE
T3 T3T3
T3 T3T3
A05
GT VD
1S T F
L N
EW
W O
RK
P
LA
N
EL
EV
A
B
A B 2'
2'
4'
3/8" = 1'-0"
INSTALL TOILET SEAT COVER DISPENSER TS1, REINSTALL
SURFACE MOUNTED SANITARY NAPKIN DISPOSAL TA2,
AND TOILET PAPER DISPENSER TA1.
REINSTALL SURFACE MOUNTED PAPER TOWEL
DISPENSER TA4.
PAINT CEILING WITH P3.
INFILL PARTITION USING METAL STUDS @ 16" O.C. AND GYP. BD. WHERE
RECESSED PAPER TOWEL DISPENSER/ TRASH RECEPTACLE HAS BEEN
REMOVED. ALIGN INFILL WITH OUTER FACE OF EXISTING PARTITION.
13 PROVIDE S2 SCHLUTER COVE TRIM ALONG ENTIRE
PERIMETER.
14 PROVIDE T4 ABOVE COUNTER AS AN ACCENT 1 TILE.
15 PROVIDE 1'-6" WIDE X 2'-6" HIGH, CUSTOM SHEET MIRROR M1.
INSTALL CENTERED OVER LAVATORIES AT 3'-4" AFF.
16 PROVIDE 3'-6" WIDE X 2'-6" HIGH, CUSTOM SHEET MIRROR M1.
INSTALL CENTERED OVER LAVATORY AT 3'-4" AFF.
PREP CONCRETE TO RECEIVE NEW FINISHES. INSTALL FLOOR TILE T1.
PROVIDE NEW MIRROR M1, LAVATORY SINKS AND SOLID SURFACE
COUNTERS L1. REINSTALL SURFACE MOUNTED SOAP DISPENSER
TA3, AND FAUCETS. REFER TO INTERIOR ELEVATIONS ON A&B /A04
AND MEP DRAWINGS FOR MORE INFORMATION.
TYP.
PROVIDE BABY CHANGING STATION CS1.
PROVIDE NEW MIRROR M1, WALL MOUNTED LAVATORY SINK L2.
REINSTALL SURFACE MOUNTED SOAP DISPENSER TA3, AND
FAUCETS. REFER TO INTERIOR ELEVATIONS ON A&B /A05 AND MEP
DRAWINGS FOR MORE INFORMATION.
PAINT MECHANICAL UNIT WITH ELECTROSTATIC PAINT P4.
A05 A07
TYP.
TYP.
T1
F3
C
B
TYP. 10
TYP.
TYP.
TYP.11
TYP.
TYP.14
TS1
F1
F2
TA1 TA2
TA3
TA4
TA3
TA4
L1 T1
SEE ELEVATION
SEE ELEVATION
EXIST. GYP
TO REMAIN
P3
TS1
TA1
A05 A07
GYPSUM BOARD CEILING / BULKHEAD
TYP.
17 PROVIDE P.LAM PL1 REMOVABLE APRON PANEL.
L1
TA3
PROVIDE T3 AS FIELD TILE , INSTALLED HORIZONTALLY.
PROVIDE ACCENT TILE T6, INSTALLED VERTICALLY,
CENTERED ON FIXTURE.
PROVIDE ACCENT TILE T5, INSTALLED VERTICALLY
CENTERED ON FIXTURE.
7'- 9"
9'-9"
7'- 9"
6'-6 15/16"
10'-1 3/4"
7'-
7'-
13'-10 1/2" 6'-2 1/8"
7'-
18 REPAIR EXISTING AREA AT EXISTING SLAB AND CORRUGATED
METAL AS REQUIRED PRIOR TO INSTALLING FLOOR FINISH.
2'-1" 8'- 5"
1X4 LED LIGHT FIXTURE
19 PROVIDE T3 AS FIELD TILE WITHIN ALL SIDES OF THE WINDOW WELL.
USE SCHLUTER S1 ON OUTSIDE CORNER OF PERIMETER OF
WINDOW. PAINT WINDOW MULLION USING P2.
2'-0"
ADA TURNING RADIUS @ 60"
Ø60" TYP.
z
7'-91
7'-111 2"
T
2ND FLOOR
TOILET ROOM NEW WORK PLAN
1/4=1'-0" A06A06
B ow m an
C on su lti ng G ro up
L td
W or ld ga te
D riv e
S ui te
H er nd on
, V A
P ho ne
3)
-0
F ax
3)
-9
LE
VE
LS
B
AS
EM
EN
T, ST
, 2 N
D
TO
W
N
HA
LL
B
AT
HR
O O
M R
EN
O
VA
TI
O N
PROJECT NO
140339-01-003
09.23.2025
FILE NO
bo w m an
.c om
B ow m an
C on su lti ng G ro up
L td
S:\Projects\Active\Vienna RR\CAD\SHEET SETS\sheets\A06 2ND FLOOR NEW WORK PLN & RCP.dwg
AS NOTED
2'
GRAPHIC SCALE: 1/4" = 1'-0"
4' 0' 4' 8'
C
EN
TE
R
S
TR
EE
T
SO
U
TH
VI
EN
N A, V
IR
G
IN
IA
KEY PLAN
NTS
2ND FLOOR
TOILET ROOM NEW WORK RCP
1/4=1'-0" A06A06
2ND FLOOR
MEN'S RR NEW WORK PLAN
1/4=1'-0" A06A06
2ND FLOOR
MEN'S RR NEW WORK RCP
1/4=1'-0" A06A06
B
A
2ND FLOOR
TOILET ROOM NEW WORK ELEVATIONS
3/8"1'-0" 5/A061/A06
2ND FLOOR
MEN'S NEW WORK ELEVATIONS
3/8"=1'-0" 6/A062/A06
2F
TOILET ROOM
2M
MEN'S RESTROOM
2F
TOILET ROOM 2M
MEN'S RESTROOM
B
A
GRAPHIC SCALE
2 0 2' 4' 8
1/4" = 1'-0"
KEY PLAN
GENERAL NOTES
1. DEDUCT 2: DEDUCT ALL WORK FROM BASE BID FOR WOMEN & MEN'S 2ND FLOOR
RESTROOMS.
2. PROVIDE NEW PLUMBING FIXTURES, COORDINATE WITH MEP DRAWINGS FOR FULL
EXTENT OF NEW WORK.
3. PROTECT EDGES OF EXISTING FLOOR FINISHES FROM DAMAGE UNTIL NEW
FLOORING AND TRANSITION STRIPS ARE INSTALLED.
4. REFER TO INTERIOR ELEVATIONS FOR MORE INFORMATION.
5. PROVIDE NEW TOILET PARTITIONS. REFER TO COLOR SCHEDULE FOR MORE
INFORMATION.
6. PROVIDE TOILET ACCESSORIES, REFER TO FIXTURE SCHEDULE ON A09 FOR MORE
INFORMATION.
7. PREP, PATCH AND REPAIR ALL GYPSUM WALLBOARD SURFACES TO RECEIVE NEW
PAINT.
8. PAINT ALL DIFFUSER AND RETURN GRILLES.
9. DOORS AND FRAMES SHALL ONLY RECEIVE PAINT ON THE INTERIOR SIDE OF THE
RESTROOMS.
10. ALL DIMENSIONS SHALL BE FIELD VERIFIED
11. ALL EXISTING DOORS, HARDWARE AND FRAMES SHALL REMAIN.
12. PROVIDE SCHLUTER S1 ON ALL EXPOSED OUTSIDE CORNERS.
13. REINSTALL EXISTING THERMOSTAT AND WIRE MOLD.
14. REPLACE ALL EXISTING WALL MOUNTED 9"X9"ACCESS PANELS IN-KIND. ALL
ACCESS PANELS SHALL BE WHITE AND LOCKABLE. FLUSH MOUNT WITH TILE.
16. PATCH AND PREPARE EXISTING WALL TO RECEIVE NEW WALL TILE.
16. PROVIDE TRANSITION, DOUBLE BEVELED, THRESHOLDS AT ALL RESTROOM ENTRIES.
CHANGES IN LEVEL BETWEEN 14" HIGH MINIMUM AND 12" HIGH MAXIMUMS SHALL BE
BEVELED WITH A SLOPE NOT STEEPER THAN 1:2.
LEGEND
PARTITION
NEW WORK KEY NOTE
2X4 LED LIGHT FIXTURE
2 X 2 CEILING DIFFUSER
12 X 6 EXHAUST GRILLE
EXISTING
TO REMAIN
TOILET PARTITION
KEY NOTES
PROJECT
AREA
FINISH SCHEDULE XXX ROOM NAME AND NUMBERXXX
NEW
WORK
2X2 CEILING RETURN
1X4 LED LIGHT FIXTURE
XXX PLUMBING FIXTURE / ACCESSORY
ROOM NAMEROOM #
TOILET ROOM2F
FLOOR BASE CEILING
TILE
CLNG HEIGHT
T1
BASE
S1
EXIST.
TO REMAIN
P3 7'-91
2"
COMMENTS
NORTH WALL SOUTH WALL EAST WALL WEST WALL
TILE/PAINT
T2
TILE/PAINT
T2
TILE/PAINT
SEE ELEVATION
TILE/PAINT
T2
ROOM NAMEROOM #
MEN'S
RESTROOM2M
FLOOR BASE CEILING
TILE
CLNG HEIGHT
T1
BASE
S1
EXIST.
TO REMAIN
P3 7'-111
2"
COMMENTS
NORTH WALL SOUTH WALL EAST WALL WEST WALL
TILE/PAINT TILE/PAINT TILE/PAINT TILE/PAINT
ROOF HATCH
T2 T2 SEE ELEVATION SEE ELEVATION
A
B
A
B
A06
GT VD
2N D
FL
N
EW
W
O
RK
EL
EV
INSTALL TOILET SEAT COVER DISPENSER TS1, REINSTALL SURFACE MOUNTED
SANITARY NAPKIN DISPOSAL TA2, AND TOILET PAPER DISPENSER TA1.
REINSTALL SURFACE MOUNTED PAPER TOWEL DISPENSER TA4.
PAINT CEILING WITH P3.
PROVIDE T4 ABOVE COUNTER AS AN ACCENT TILE.
PROVIDE 1'-6" WIDE X 2'-6" HIGH, CUSTOM SHEET MIRROR M1, INSTALLED
3'-4" AFF.
PROVIDE 3'-6" WIDE X 2'-6" HIGH, CUSTOM SHEET MIRROR M1.
INSTALL CENTERED TO THE LAVATORIES AT 3'-4" AFF.
PAINT MECHANICAL UNIT WITH ELECTROSTATIC PAINT P4.
PREP CONCRETE TO RECEIVE NEW FINISHES. INSTALL FLOOR TILE T1.
PROVIDE NEW MIRROR M1, LAVATORY SINKS AND SOLID SURFACE
COUNTERS L1. REINSTALL SURFACE MOUNTED SOAP DISPENSER
TA3, AND FAUCETS. REFER TO INTERIOR ELEVATIONS ON A&B /A06
AND MEP DRAWINGS FOR MORE INFORMATION.
PROVIDE NEW MIRROR M1, WALL MOUNTED LAVATORY SINK L2.
REINSTALL SURFACE MOUNTED SOAP DISPENSER TA3, AND FAUCETS.
REFER TO INTERIOR ELEVATIONS ON A&B /A06 AND MEP DRAWINGS FOR
MORE INFORMATION.
4 6
9 9
REINSTALL EXISTING SURFACE MOUNTED ROOF HATCH ACCESS
LADDER. PAINT LADDER AND INTERIOR SIDE OF ROOF HATCH WITH
P2. PAINT ROOF HATCH SHAFT WITH P3 WITH GLOSS FINISH.
17 INSTALL TOILET SEAT COVER DISPENSER TS1, AND
REINSTALL TOILET PAPER DISPENSER TA1.
TYP.
18 REINSTALL EXISTING THERMOSTAT. REFER TO MEP
DRAWINGS FOR MORE INFORMATION.
TYP.
TYP.
L1T1T1
U1 U1 L2L2
TYP.
TYP.
INFILL PARTITION USING METAL STUDS @ 16" O.C. AND GYP. BD. WHERE
RECESSED PAPER TOWEL DISPENSER/ TRASH RECEPTACLE HAS BEEN
REMOVED. ALIGN INFILL WITH OUTER FACE OF EXISTING PARTITION.
A05 A07
A05 A07
19 PROVIDE NEW SIGNAGE FOR TOILET ROOM. MATCH
BUILDING STANDARD.
PROVIDE SCHLUTER S2 AS COVE TRIM ALONG ENTIRE PERIMETER.
20 PROVIDE P.LAM PL1 REMOVABLE APRON PANEL.
TA4
2' 2'0 4'
3/8" = 1'-0"
PROVIDE T3 AS FIELD TILE , INSTALLED HORIZONTALLY.
PROVIDE ACCENT TILE T6, INSTALLED VERTICALLY, CENTERED ON FIXTURE.
PROVIDE ACCENT TILE T5, INSTALLED VERTICALLY CENTERED ON FIXTURE.
PROVIDE T3 AS FIELD TILE WITHIN ALL SIDES OF THE WINDOW WELL.
USE SCHLUTER S1 ON OUTSIDE CORNER OF PERIMETER OF
WINDOW. PAINT WINDOW MULLION USING P2.
GYPSUM BOARD CEILING / BULKHEAD
7'- 9"
9'-9"
7'- 9"
6'-8"
7'-
14'-6"
10'-1 7/8"
7'-
1/ 2"
2'-0"
ADA TURNING RADIUS @ 60"
Ø60" TY
P.
z
EXISTING TOILET PAPER
DISPENSER
SHEET MIRROR
CUSTOM SIZES
" M
AX
. T
O
RE
FL
EC
TIV
E
SU
RF
AC
E
EXISTING SIDE
WALL GRAB
36"
42"
EXISTING VERTICAL
GRAB BAR
CL
OF
WATER CLOSET
12"12"
FOW @ REAR OF TOILETFOW @ REAR OF TOILET
CL
40"
EXISTING SURFACE
MOUNTED SANITARY
NAPKIN DISPOSAL
TOILET SEAT COVER, METPAR CORP.
TSC-100
FINISH: STAINLESS STEEL
EXISTING SURFACE
MOUNTED SOAP
DISPENSER
EXISTING REAR
WALL GRAB
BABY CHANGING
STATION, KOALA
KARE, KB310-SSWM
FINISH: STAINLESS
STEEL, SURFACE
MOUNTED
3 4"
BO
TTO
M O
F
CL
O
SE
D
BE
D A.
F.F
CLFRONT
OF
W.C.
8"
HOOK, BOBRICK, B-9542,
FINISH: SATIN STAINLESS
STEEL, SURFACE MOUNTED
T.O. CLOTHES
HOOK MOUNT TO
AND CENTERED
HORIZONTALLY AT
ALL RESTROOM
DOORS
L1 L2T1
TA1 TA2
F3F2F1 TS1
TA3
M1
CS1
TA5
24" STANDARD
INSTALLATION
17" MAX ADA
INSTALLATION
U1WATERCLOSET
REFER TO MEP DWGS FOR
SPECIFICATIONS
URINAL
REFER TO MEP DWGS FOR
SPECIFICATIONS
FOW @ REAR OF TOILET
EXISTING SURFACE
MOUNTED PAPER
TOWEL DISPENSER
TA4
FOW
UNDER-MOUNT LAVATORY
REFER TO MEP DWGS FOR
SPECIFICATIONS
WALL MOUNT LAVATORY
REFER TO MEP DWGS FOR
SPECIFICATIONS
MOUNTING HEIGHTS
3/8"=1'-0" A08A08
B ow m an
C on su lti ng G ro up
L td
W or ld ga te
D riv e
S ui te
H er nd on
, V A
P ho ne
3)
-0
F ax
3)
-9
LE
VE
LS
B
AS
EM
EN
T, ST
, 2 N
D
TO
W
N
HA
LL
B
AT
HR
O O
M R
EN
O
VA
TI
O N
PROJECT NO
140339-01-003
09.23.2025
FILE NO
bo w m an
.c om
B ow m an
C on su lti ng G ro up
L td
S:\Projects\Active\Vienna RR\CAD\SHEET SETS\sheets\A07 SCHEDULES.dwg
AS NOTED
2'
GRAPHIC SCALE: 1/4" = 1'-0"
4' 0' 4' 8'
C
EN
TE
R
S
TR
EE
T
SO
U
TH
VI
EN
N A, V
IR
G
IN
IA
GRAPHIC SCALE
GENERAL NOTES
1. COORDINATE WITH MEP DRAWINGS FOR FULL EXTENT OF NEW WORK.
2. PROVIDE BLOCKING AS REQUIRED FOR ALL NEW AND REINSTALLED EXISTING
ACCESSORIES.
LEGEND
NTS
XXX NEW PLUMBING FIXTURE
AND ACCESSORY
KEY PLAN
2'-
REINSTALL EXISTING
FAUCET
SOLID SURFACE SS1 FINISH ON 12" EXT.
GRADE PLYWOOD
ACCENT TILE T4
L1 LAVATORY , REFER TO PLUMBING PLAN
P.LAM PL1 ON 34" TREATED PLYWOOD REMOVABLE APRON
PANEL W/Z-CLIPS MOUNTED TO 3x3 CLEAT EACH END
A07
SC
HE
DU
LE
S & D
ET
AI
LS
SECTION DETAIL
1/2"=1'-0" A07
2' 2'0 4'
3/8" = 1'-0"
4'2'01'
1/2" = 1'-0"
SECTION DETAIL
1/2"=1'-0" A07
2'-0 3/8"
9" CL
R.
MIRROR M1
ADHERED TO TILE
6" 2'-
EXISTING FAUCET
TILE - REFER TO ELEVATIONS FOR TILE
L2 WALL MOUNTED LAVATORY,
REFER TO PLUMBING PLAN
MIRROR M1
ADHERED TO TILE
6"
P-TRAP, REFER TO PLUMBING PLAN
P-TRAP WITH INSULATION, REFER
TO PLUMBING SHEETS
FLOOR TILE T1
CONC.3"X3"X1/4" STL. ANGLE W/ WELDED END PLATES. SECURE
AND PLATE W/ E.B. TO MASONRY PARTITIONS AND W/ LB. TO
MTL. STUD PARTITION
2X4 PRESSURE TREATED WD. 3'-0" O.C., MAX., CENTERED
BETWEEN SINKS & EACH END WALL
COVE TRIM S2
EXISTING PARTITION
NEW 2x PRESSURE TREATED WD, PAINTED P2. BLOCKING BETWEEN
EXISTING METAL STUD
FLOOR TILE T1
COVE TRIM S2
8"
EXISTING PARTITION
SEALANT ALONG ENTIRE
PERIMETER ON BOTH
SIDES OF S2 TRIM
SEALANT ALONG ENTIRE
PERIMETER ON BOTH
SIDES OF S2 TRIM
COMPLY WITH ALL APPLICABLE AWI STANDARDS
z m an
C on su lti ng G ro up
L td
W or ld ga te
D riv e
S ui te
H er nd on
, V A
P ho ne
3)
-0
F ax
3)
-9
LE
VE
LS
B
AS
EM
EN
T, ST
, 2 N
D
TO
W
N
HA
LL
B
AT
HR
O O
M R
EN
O
VA
TI
O N
PROJECT NO
140339-01-003
09.23.2025
FILE NO
bo w m an
.c om
B ow m an
C on su lti ng G ro up
L td
J:\T\140339-01-003 Town Hall Bathroom Reno Vienna\Drawings\CADD\ELEC\E00 COVER SHEET-ELEC.dwg
AS NOTED
C
EN
TE
R
S
TR
EE
T
SO
U
TH
VI
EN
N A, V
IR
G
IN
IA
12/12/2025PERMIT RESUBMITTAL1
DC JM
ELECTRICAL NOTES AND SPECIFICATIONS
DRAWING LIST
1. ALL WORK SHALL BE DONE IN CONFORMANCE WITH ALL LOCAL AND STATE CODES RULES AND REGULATIONS, THE LATEST ADOPTED JURISDICTIONAL CODES, AND OF THE AUTHORITY HAVING JURISDICTION.
2. OBTAIN AND PAY FOR ALL PERMITS, ALL FEES AND ALL TAXES.
3. IT IS THE INTENTION OF THE SPECIFICATIONS AND DRAWINGS TO CALL FOR FINISHED WORK, TESTED AND READY FOR OPERATION. WHENEVER THE WORD "PROVIDE" IS USED, IT SHALL MEAN "FURNISH AND INSTALL
COMPLETE AND READY FOR USE".
4. PROVIDE ALL LABOR, MATERIAL, EQUIPMENT, FIXTURES, SERVICES AND PERFORM ALL OPERATIONS REQUIRED FOR A COMPLETE AND SAFE INSTALLATION OF THE ELECTRICAL SYSTEMS AND RELATED WORK.
ELECTRICAL SYSTEMS AND EQUIPMENT SHALL IN GENERAL INCLUDE THE FOLLOWING:
4.A. GENERAL PROVISIONS FOR ELECTRICAL WORK
4.B. WIRING, DISTRIBUTION EQUIPMENT, RACEWAYS AND DEVICES
4.C. LIGHTING FIXTURES AND LAMPS
4.D. GROUNDING SYSTEM
4.E. TELEPHONE CONDUIT
4.F. MECHANICAL EQUIPMENT, MOTORS AND PLUMBING EQUIPMENT, WIRING AND CONDUIT
4.G. FIRE ALARM SYSTEM
4.H. INSTALLATION AND ALL CONNECTIONS.
5. PROVIDE ALL MATERIAL AND EQUIPMENT NOT INDICATED AS EXISTING IN THE CONTRACT DOCUMENTS. ALL MATERIAL SHALL BE NEW AND THE BEST PRODUCTS OF REPUTABLE MANUFACTURERS AND SHALL BE IN NEW
CONDITION AT ACCEPTANCE OF WORK.
6. PROVIDE A GUARANTEE TO COVER ALL MATERIALS, LABOR AND EQUIPMENT. GUARANTEE SHALL BE FOR A PERIOD OF ONE YEAR FROM THE DATE OF ACCEPTANCE BY THE OWNER. GUARANTEE SHALL COVER PAYMENT FOR ANY REPAIRS OR REPLACEMENTS CAUSED BY DEFECTIVE WORKMANSHIP OR FAULTY
MATERIALS WITHIN THE PERIOD COVERED BY THE GUARANTEE.
7. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH NECA-1 GOOD WORKMANSHIP IN ELECTRICAL
CONSTRUCTION.
8. THE CONTRACTOR SHALL WALK THE WORK SITE PRIOR TO BIDDING AND VERIFY EXISTING CONDITIONS.
DRAWINGS ARE DIAGRAMMATIC AND REPRESENT THE ENGINEERING ASSESSMENT AT THE TIME OF DESIGN.CIRCUITS SHOWN ARE BASED ON RECORD DRAWING AND FIELD CONDITIONS. CONDUIT SHALL NOT BE CONSIDERED AS DIRECT PATH STRAIGHT RUNS. THE CONTRACTOR SHALL EXPECT TO ROUTE CONDUIT AROUND EXISTING STRUCTURAL COMPONENTS AND ALL EQUIPMENT. THE CONTRACTOR SHALL PROVIDE REQUIRED PULL BOXES TO MAINTAIN NO MORE THAN FOUR 90 DEGREE EQUIVALENT BENDS IN EACH CONDUIT
RUN.
9. PROVIDE ALL SCAFFOLDING, RIGGING, HOISTING, AND SERVICES NECESSARY FOR ERECTION AND DELIVERY INTO THE PREMISES OF ANY EQUIPMENT AND APPARATUS, WHETHER FURNISHED BY THIS CONTRACT OR
OWNER, AND REMOVAL OF SAME FROM PREMISES WHEN NO LONGER REQUIRED.
10. INSTALL ALL WORK IN A NEAT AND ORDERLY MANNER, USING ONLY WORKMEN THOROUGHLY QUALIFIED IN
THE TRADE OR DUTIES THEY ARE TO PERFORM. ROUGH WORK WILL BE REJECTED.
11. UNLESS OTHERWISE REQUIRED BY TRADE CUSTOM OR SPECIFIED UNDER ANOTHER SECTION OF THE SPECIFICATIONS, CUTTING AND PATCHING SHALL BE DONE BY THE APPROPRIATE TRADE. PROVIDE SKETCHES
SHOWING THE LOCATIONS AND SIZES OF ALL OPENINGS, CHASES ETC. REQUIRED.
12. DO NOT CUT STRUCTURAL MEMBERS WITHOUT THE APPROVAL OF THE ARCHITECT/ENGINEER, AND ALL SUCH
CUTTING SHALL BE DONE IN MANNER DIRECTED BY HIM.
13. MAINTAIN CLEAN WORK AREA AT ALL TIMES DURING CONSTRUCTION.
14. TEST ALL LIGHTING, POWER, FIRE ALARM AND OTHER SYSTEMS. SYSTEMS SHALL OPERATE SATISFACTORILY
AS DESIGNED AND INTENDED. REPORT ANY DEFICIENCIES TO THE ARCHITECT/ENGINEER.
15. PROVIDE A FIELD-APPLIED WARNING LABEL ON EACH SWITCHBOARD, PANELBOARD, CONTROL PANEL, STARTER, VFD, AND MOTOR CONTROL CENTER TO WARN QUALIFIED PERSONS OF POTENTIAL ELECTRIC ARC
FLASH HAZARD, PER NEC 110.16.
16. GENERAL PROVISION FOR ELECTRICAL WORK:
16.A. DRAWINGS: ELECTRICAL DRAWINGS ARE CONSIDERED DIAGRAMMATIC AND INDICATE GENERAL
ARRANGEMENT OF WORK AND SYSTEMS. REFER TO ARCHITECTURAL DRAWINGS TO VERIFY
LOCATION OF EQUIPMENT, ETC. COORDINATE ROUGH-IN REQUIREMENTS AND INSTALLATION
REQUIREMENTS WITH OTHER TRADES.
16.B. QUALITY OF MATERIALS: NEW, BEST OF THEIR RESPECTIVE KIND, FREE FROM DEFECTS, AND LISTED
BY UNDERWRITERS LABORATORIES, INC. AND BEARING THEIR LABEL.
16.C. VOLTAGE CHARACTERISTICS: 277/480 VOLT AND 120/208 VOLT, 3 PHASE, 4 WIRE, 60 HERTZ WITH
GROUNDED NEUTRAL AS NOTED.
16.D. SHOP DRAWINGS:
16.D.1. SUBMIT ELECTRONIC SHOP DRAWINGS FOR ALL FIXTURES AND DEVICES. OBTAIN
APPROVAL BEFORE EQUIPMENT IS ORDERED, BUILT OR INSTALLED. CATALOGS,
PAMPHLETS, OR OTHER DOCUMENTS SUBMITTED TO DESCRIBE ITEMS FOR WHICH
APPROVAL IS BEING REQUESTED SHALL BE AS SPECIFIED AND IDENTIFICATION CATALOG,
PAMPHLET, ETC., OF ITEM SUBMITTED SHALL BE CLEARLY NAMED IN INK. DATA OF A
GENERAL NATURE AND FAXES WILL NOT BE ACCEPTED. SUBMITTAL SHALL INCLUDE
CONTRACTOR'S NAME AND NAME OF JOB.
16.D.1.a. LIGHTING FIXTURES 16.D.1.b. LIGHTING CONTROLS 16.D.1.c. WIRING DEVICES 16.D.1.d. WIRING DEVICE PLATES 16.D.1.e. BUILDING WIRE 16.D.1.f. DISTRIBUTION EQUIPMENT (PANEL BOARDS, TRANSFORMERS, ETC) 16.D.1.g. SAFETY SWITCHES 16.D.1.h. FIRE ALARM APPLIANCES AND PANELS 16.D.1.i. RGS, IMC, EMT, PVC CONDUIT
16.D.2. PROVIDE LIGHTING CONTROLS SHOP DRAWINGS THAT SHALL INCLUDE, BUT NOT LIMITED
TO, ALL THE FOLLOWING:
16.D.2.a. MANUFACTURER DATA SHEETS ON EACH PRODUCT TO BE USED INCLUDING:
16.D.2.a.a. CATALOG SHEETS AND SPECIFICATIONS.
16.D.2.a.b. RATINGS, CONFIGURATIONS, STANDARD WIRING DIAGRAMS, DIMENSIONS, COLORS, SERVICE CONDITION REQUIREMENTS, AND
INSTALLED FEATURES.
16.D.2.a.c. INSTALLATION INSTRUCTIONS.
16.D.2.a.d. WARRANTY INFORMATION.
16.D.2.b. PROVIDE WIRING DIAGRAMS AND DIMENSIONED FLOOR PLANS THAT
INCLUDE THE VARIOUS COMPONENTS OF THE SYSTEM SPECIFIED
INCLUDING:
16.D.2.b.a. COMPOSITE WIRING AND/OR SCHEMATIC DIAGRAM OF EACH CONTROL
CIRCUIT AS PROPOSED TO BE INSTALLED.
16.D.2.b.b. FLOOR PLANS THAT SHOW LOCATION OF ALL DEVICES, INCLUDING AT
MINIMUM SENSORS, LOAD CONTROLLERS, AND SWITCHES/DIMMERS
FOR EACH AREA ON REFLECTED CEILING PLANS.
16.D.2.b.c. FLOOR PLANS THAT SHOW THE DIFFERENT LIGHTING CONTROL ZONES
PER ROOM OR SPACE AS SHOWN ON THE LIGHTING PLANS, ENLARGED
PLANS, AND SEQUENCE OF OPERATIONS.
16.D.2.b.d. PROVIDE ROOM/SPACE DETAILS INCLUDING PRODUCTS AND SEQUENCE
OF OPERATION FOR EACH ROOM OR SPACE. ILLUSTRATE TYPICAL
ACCEPTABLE ROOM/SPACE CONNECTION TOPOLOGIES.
16.D.2.b.e. NETWORK RISER DIAGRAM INCLUDING FLOOR AND BUILDING LEVEL
DETAILS. INCLUDE NETWORK CABLE SPECIFICATION. ILLUSTRATE
POINTS OF CONNECTION TO INTEGRATED SYSTEMS. COORDINATE
INTEGRATION WITH MECHANICAL AND/OR OTHER TRADES.
16.E. INSTALL ALL NEW WORK WITH MINIMUM INTERFERENCE TO EXISTING FACILITIES.
16.F. VISIT SITE AND INSPECT EXISTING FACILITIES BEFORE BID IN ORDER TO ENSURE PROPER
EVALUATION OF WORKING CONDITIONS AND LOCATION OF EXISTING EQUIPMENT.
17. WIRING, DISTRIBUTION EQUIPMENT AND DEVICES:
17.A. CONDUCTORS: COPPER, IN ACCORDANCE WITH ASTM STANDARDS, SIZE REFERENCES AWG.
CONDUCTORS ARE BASED ON 90°C RATING. NO. 10 AND SMALLER - SOLID, THHN OR THHW 600 VOLT;
NO. 8 AND LARGER - STRANDED THHW OR THHN 600 VOLT. MINIMUM SIZE: NO. 12.
17.A.1. TYPE MC CABLE SHALL BE INTERLOCKED STEEL ARMOR WITH INSULATED GROUNDING
CONDUCTOR FOR BRANCH CIRCUITING AND FEEDERS, UP TO A MAXIMUM OF 20 AMPS PER
CIRCUIT, MAY BE SUBSTITUTED FOR CONDUCTORS IN CONDUIT. SUPPORT CABLE EVERY
6'-0" AND WITHIN 12" OUTLET AND IN ACCORDANCE WITH THE NEC. CABLE MUST BE
SUPPORTED IN A NEAT AND ORDERLY MANNER.
CONTRACTOR SHALL PROVIDE NEUTRAL CONDUCTOR IN SWITCH BOXES COMPLYING WITH NEC
404.2(C).
17.A.1. ALL CONDUCTORS SHALL BE IDENTIFIED BY COLOR AS INDICATED IN THE COLOR CODE
CHART.
COLOR CODE CHART
PHASE A PHASE B PHASE C NEUTRAL GROUND
120/208V BLACK RED BLUE WHITE GREEN
277/480V BROWN ORANGE YELLOW GRAY GREEN
17.B. RACEWAYS: (ROUTE CONCEALED BEHIND OR ABOVE BUILDING FINISHES UON)
17.B.1. ELECTRIC METALLIC TUBING (EMT), THIN WALL PIPE, GALVANIZED, MINIMUM 1/2" EXCEPT
AS NOTED OR REQUIRED FOR WIRING.
17.B.2. ALL FITTINGS AND COUPLINGS SHALL BE STEEL - CAST FITTINGS PROHIBITED.
17.B.3. BELOW GRADE: MINIMUM 1" SCHEDULE 40 PVC, RIGID GALVANIZED STEEL CONDUIT,
INTERMEDIATE METAL CONDUIT, EMT WITH COMPRESSION FITTINGS IS NOT ACCEPTABLE.
17.C. TERMINATIONS: ALL EQUIPMENT PROVIDED ON THE PROJECT, INCLUDING PANELBOARDS AND
DISCONNECT SWITCHES, SHALL HAVE MANUFACTURER TERMINATIONS RATED AT 75°C.
17.D. CIRCUIT BREAKERS: CIRCUIT BREAKERS SHALL BE MOLDED CASE, THERMAL-MAGNETIC
QUICK-MAKE, QUICK-BREAK, BOLT-ON TYPE WITH MANUALLY OPERATED INSULATED TRIP-FREE
HANDLE. MULTI-POLE TYPES WITH INTERNAL COMMON TRIP BAR. TERMINALS SUITABLE FOR
COPPER CONDUCTORS.
17.E. DISCONNECT SWITCHES: DISCONNECT SWITCHES SHALL BE HEAVY-DUTY, ENCLOSED SAFETY
SWITCHES AS MANUFACTURED BY SIEMENS. SWITCHES SHALL BE OF THE QUICK-MAKE,
QUICK-BREAK TYPE WITH INTERLOCKING COVERS AND STEEL BOXES OF THE TYPE ENCLOSURE
REQUIRED FOR EACH LOCATION. SQUARE D, CUTLER HAMMER WILL BE CONSIDERED. MATCH BASE
BUILDING DISTRIBUTION EQUIPMENT.
17.F. OUTLET BOXES: OUTLET BOXES SHALL BE RECESSED MOUNTED AND SHALL BE CODE GAUGE STEEL
AND OF SIZE REQUIRED FOR SPECIFIC CONDITIONS.
18. LIGHTING FIXTURES AND LAMPS:
18.A. PROVIDE COMPLETE SYSTEM OF LIGHTING FIXTURES, LAMPS, ACCESSORIES AND SUPPORTS AS
SPECIFIED AND SHOWN. FOR TYPES, REFER TO SCHEDULE.
18.B. COORDINATE THE LIGHTING FIXTURE LAYOUT WITH THE ARCHITECTURAL REFLECTED CEILING PLAN.
ALL LIGHTING FIXTURES MOUNTED IN OR ON LAY-IN CEILING TILES SHALL BE LOCATED IN CENTER
OF TILE UNLESS OTHERWISE APPROVED BY ARCHITECT.
19. GROUNDING SYSTEM:
19.A. EQUIPMENT: GROUND NON-CURRENT CARRYING METAL PARTS OF THE ELECTRICAL SYSTEM.
PROVIDE A SEPARATE GREEN INSULATED EQUIPMENT GROUNDING CONDUCTOR WITH ALL FEEDERS AND BRANCH CIRCUITS, SIZED IN ACCORDANCE WITH THE OVERPROTECTIVE DEVICE SERVING THAT
FEEDER OR BRANCH CIRCUIT.
20. DEMOLITION:
20.A. DEMOLITION DRAWINGS ARE BASED ON ARCHITECTURAL PLANS, EXISTING PLANS AND FIELD
SURVEY. COORDINATE DEMOLITION WORK WITH ALL DISCIPLINES TO AVOID CONFLICTS.
20.B. FOR PLAN LINETYPE DESIGNATIONS OF REMOVED, RELOCATED, EXISTING AND NEW DEVICES REFER
TO THE ELECTRICAL SYMBOLS LIST.
20.C. DEVICES BEYOND REMODELED AREAS OF THIS CONTRACT THAT ARE WIRED THROUGH OR FROM
OUTLETS TO BE REMOVED OR ABANDONED SHALL REMAIN AND REMAIN OPERABLE.
20.D. REMOVE ALL ACCESSIBLE EXISTING CONDUIT INCLUDING FITTINGS, MOUNTING DEVICES, MOUNTING HARDWARE ETC. NOT BEING USED. PROVIDE CONDUIT CAPS FOR ALL ABANDONED CIRCUITS THAT
ARE TO REMAIN.
20.E. THE CONTRACTOR SHALL REMOVE THE CONDUIT FEEDING DEMOLISHED RECEPTACLES AND
ELECTRICAL DEVICES THAT ARE FED FROM UNDER THE FLOOR SLAB OR ARE EMBEDDED IN A WALL NOT SCHEDULED TO BE DEMOLISHED TO 2" BELOW EXISTING FLOOR LEVEL OR WITH THE WALL.
20.F. REMOVE ALL EXISTING WIRE AND CABLE NOT BEING USED.
20.G. WHERE EXISTING ELECTRICAL DEVICES ARE SHOWN BEING REMOVED AND JUNCTION BOXES ARE
NOT BEING RE-USED, REMOVE EXISTING WIRE AND CABLE, PROVIDE BLANK COVERPLATE.
20.H. ITEMS TO BE SALVAGED FOR REUSE OR DELIVERY TO OWNER SHALL BE PROTECTED AND STORED IN CONDITIONED SPACE BY CONTRACTOR UNTIL REUSED OR TRANSFERRED TO OWNER. PROVIDE A TYPEWRITTEN INVENTORY TO OWNER INCLUDING ALL ELECTRICAL DEVICES BEING REMOVED: I.E.
FIXTURES, SWITCHES, ETC. ALL MATERIALS REMOVED UNDER DEMOLITION THAT ARE NOT
DESIGNATED TO BE RETURNED TO THE OWNER SHALL BE PROPERLY AND LEGALLY DISPOSED FROM
THE PROJECT SITE.
20.I. ALL DEMOLITION WORK SHALL BE SCHEDULED AND COORDINATED AT TIMES CONVENIENT TO THE
OWNER OR BUILDING MANAGEMENT.
21. INSTALLATION:
21.A. SECURE ALL SUPPORTS TO BUILDING STRUCTURE. SUPPORT HORIZONTAL RUNS OF CONDUIT NOT MORE THAN 10 FEET APART. RUN EXPOSED RACEWAYS PARALLEL WITH OR AT RIGHT ANGLES TO
WALLS.
21.B. CUT CONDUIT ENDS SQUARE, REAM SMOOTH AND DRAW UP TIGHT WITH CONDUIT COUPLINGS.
PROVIDE NYLON BUSHING AT ALL OPEN CONDUIT ENDS.
21.C. LEAVE WIRE SUFFICIENTLY LONG TO PERMIT MAKING FINAL CONNECTIONS.
21.D. SET BOXES SQUARE AND TRUE WITH BUILDING FINISH.
21.E. ALL BRANCH CIRCUIT WIRING, CONDUIT AND FEEDERS SHALL BE INSTALLED CONCEALED BEHIND
BUILDING FINISHES UNLESS OTHERWISE NOTED.
21.F. ALL TELEPHONE/DATA CIRCUIT WIRING, AND CONDUIT SHALL BE INSTALLED CONCEALED BEHIND
BUILDING FINISHES UNLESS OTHERWISE NOTED.
21.G. COORDINATE LIGHT SWITCH LOCATIONS WITH DOOR SWINGS. SWITCHES SHALL BE INSTALLED ON
LATCH SIDE OF DOOR AS CLOSE AS POSSIBLE TO FRAME.
21.H. PROVIDE PULL STRING IN ALL EMPTY CONDUITS.
21.I. JUNCTION AND PULL BOXES: LOCATED GENERALLY NOT EXPOSED IN FINISHED SPACES WHERE
NECESSARY, REROUTE CONDUITS OR MAKE OTHER ARRANGEMENTS FOR CONCEALMENT. PROVIDE
PULL BOXES WHEREVER NECESSARY TO FACILITATE PULLING OF WIRE. COVERS OF JUNCTION AND
PULL BOXES SHALL BE ACCESSIBLE. COORDINATE LOCATIONS WITH OTHER TRADES. PROVIDE
CAST METAL JUNCTION BOXES FOR EXTERIOR LOCATIONS.
21.J. PROVIDE ACCESS PANELS IN ALL INACCESSIBLE CEILING SPACES, AS REQUIRED, BY THE NEC.
21.K. MAINTAIN CODE REQUIRED CLEARANCES FOR DISTRIBUTION EQUIPMENT AND DEVICES IN ALL
LOCATIONS.
21.L. ALL WALL, FLOOR, CEILING OR ROOF PENETRATIONS SHALL BE PERPENDICULAR SO THEY CAN BE
PROPERLY CAULKED AND/OR FIRE SEALED TO MAINTAIN THE RATING OF THE ASSEMBLY OR A
MINIMUM 2-HOUR RATING PENETRATION.
21.M. THE CIRCUIT NUMBERS ARE FOR IDENTIFICATION ONLY. HOMERUNS OF SIMILAR SINGLE PHASE CIRCUITS MAY BE COMBINED IN ONE CONDUIT WITH A COMMON NEUTRAL. PROVIDE NEUTRAL FOR EACH GFI CIRCUIT. ONLY THREE SINGLE PHASE CIRCUITS (120V OR 277V) MAY BE COMBINED IN ANY
ONE CONDUIT. ON COMPLETION OF THE PROJECT, BALANCE THE PANEL LOAD UNDER NORMAL
OPERATING CONDITIONS. (MAXIMUM 10% DEVIATION BETWEEN PHASES).
21.N. 120 VOLT BRANCH CIRCUITS OVER 100 FEET FROM PANEL TO FIRST OUTLET SHALL HAVE
CONDUCTORS ONE SIZE LARGER THAN INDICATED WHETHER INDICATED IN THE PANEL SCHEDULE
OR NOT.
21.O. THE QUANTITY OF WIRES MAY NOT BE INDICATED FOR ALL CIRCUITS. ONLY THOSE WHERE CLARIFICATION IS NECESSARY ARE INDICATED. PROVIDE ALL WIRES NECESSARY FOR THE PROPER
FUNCTION OF THE SYSTEM WHETHER INDICATED ON PLANS OR NOT.
21.P. ALL EQUIPMENT, SUCH AS STARTERS, RELAYS, CONTACTORS, SWITCHES, PANELS, AND OTHER DISTRIBUTION EQUIPMENT SHALL HAVE IDENTIFICATION PLATES OF BLACK LAMINATED PLASTIC WITH 1/2" WHITE LETTERS. EQUIPMENT IDENTIFICATION SHALL MATCH THE CONTRACT DOCUMENTS.
21.Q. ELECTRICAL METALLIC TUBING SHALL BE USED FOR EMERGENCY AND LIFE SAFETY LOADS.
21.R. ALL PHASE LOADS ON PANELBOARDS (NEW AND EXISTING) THAT ARE PART OF THE SCOPE OF WORK
SHALL BE BALANCED AND MAXIMUM DIFFERENCE SHALL NOT EXCEED 10 PERCENT.
21.S. LABEL CIRCUIT NUMBERS IN BACK BOXES OF ALL DEVICES.
21.T. INSTALL DIGITAL LIGHTING CONTROL SYSTEM IN ACCORDANCE WITH APPROVED SHOP DRAWINGS
AND MANUFACTURER'S INSTRUCTIONS.
CO
VE
R
SH
EE
T
- E
LE
C
10/24/210/29/2512/19/25 z m an
C on su lti ng G ro up
L td
W or ld ga te
D riv e
S ui te
H er nd on
, V A
P ho ne
3)
-0
F ax
3)
-9
LE
VE
LS
B
AS
EM
EN
T, ST
, 2 N
D
TO
W
N
HA
LL
B
AT
HR
O O
M R
EN
O
VA
TI
O N
PROJECT NO
140339-01-003
09.23.2025
FILE NO
bo w m an
.c om
B ow m an
C on su lti ng G ro up
L td
J:\T\140339-01-003 Town Hall Bathroom Reno…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .