EXHIBIT 6 PLANS~1.pdf
PDF 613 KB Posted
- Attached to
- Davis Slough three roofs replacement
- Solicitation number
- S-73000-00018265
- Issued by
- Coos County, Condon City, Oregon
About this file
This document is a site and roof plan set for the Oregon Department of Transportation (ODOT) Davis Slough Maintenance Station roof replacement project located at 61036 US-101, Coos Bay, Oregon 97420. The project scope involves roof replacement work across three buildings: Maintenance Building #01 (6,237 SF), Storage Building #04 (4,109 SF), and Electrical Storage Building #03 (1,488 SF). For Maintenance Building #01, the contractor must remove existing metal roofing panels and insulation, then install new metal roofing panels. For Electrical Storage Building #03, work includes removing existing metal panels and vapor barrier in Area #1 and installing new metal roofing panels with vapor barrier, while Areas #2 and #3 require new metal roofing panels only. Storage Building #04 requires removal of existing metal roofing panels and insulation with installation of new metal roofing panels over new condensation blanket insulation. The plans indicate a project number F40613 with a date of 09/30/26 and reference Franco as an associated entity.
The document establishes that contractors must conform to all applicable codes, laws, and ordinances, conduct a mandatory site visit prior to bidding, and submit any discrepancies or clarifications in writing before installation. All work and materials are the contractor's responsibility unless specifically noted as existing or provided by ODOT. The plans are schematic in nature, and contractors must supply all minor components and materials necessary for a complete and functional project. Substitution requests for basis of design products must be made during the bid process with ODOT's sole discretion determining acceptability. Equipment and materials must be installed per manufacturer's instructions, and the contractor must clean the entire work area upon project conclusion to the satisfaction of the ODOT Construction Project Manager.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| EXHIBIT 5 SPECIFICATIONS.docx | DOCX document | |
| ExhIbit 7 Additional Project Requirements.doc | DOC document | |
| 00018265 ITB.pdf | ||
| 00018625 Sample PI Contract.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
WALLOWA
UNION
UMATILLA
MORROW
GILLIAM
SHERMANWASCO
HOOD
RIVER
CLACKAMAS
MULTNOMAH
COLUMBIA
CLATSOP
TILLAMOOK
WASHINGTON
YAMHILL
POLK
LINCOLN
BENTON
LINN
MARION
LANE
DOUGLAS
COOS
CURRY
JOSEPHINE
JACKSON
KLAMATH
LAKE
HARNEY
MALHEUR
CROOK
JEFFERSON WHEELER
GRANT
BAKER
DESCHUTES
26 JOHN
DAY
THE
DALLES
PENDLETON
LA
GRANDE
BAKER
CITY
ONTARIO
BURNS
BEND
KLAMATH
FALLS
PORTLAND
SALEM
EUGENE
ROSEBURG
MEDFORD
COOS
BAY
NEWPORT
ASTORIA
FLORENCE
CORVALLIS
ALBANY
ASHLAND
LAKEVIEW
ODOT DAVIS SLOUGH
MAINTENANCE STATION
MAINTENANCE BUILDING #01
F4061301
STORAGE
BUILDING #04
F4061304
ELECTRICAL
STORAGE #03
F4061303
OREGON
COST HWY 101
REDUCED 50%
WHEN PRINTED
AT 11" x 17"
TH
IS
D R
AW
IN
G
IS
R
ED
U C
ED
IF
B O
R D
ER
IS
N O
T
/2
" x
2"
F40613
ODOT DAVIS SLOUGH MAINTENANCE STATION
ROOF REPLACEMENTS
61036 US-101, COOS BAY, OR 97420 3
09/30/26
FRANCO
ODOT DAVIS SLOUGH MAINTENANCE STATION
ROOF REPLACEMENTS
61036 US-101, COOS BAY, OR 97420
1. ALL WORK SHALL CONFORM TO APPLICABLE CODES, LAWS AND ORDINANCES OF THE JURISDICTION HAVING AUTHORITY.
2. DO NOT SCALE THE DRAWINGS.
3. CONTRACTOR SHALL MAKE A SITE VISIT AND EXAMINE EXISTING CONDITIONS PRIOR TO PROVIDING A BID. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF ODOT THROUGH A REQUEST FOR CLARIFICATION AS SET
FORTH IN THE BID DOCUMENTS.
4. CLARIFICATIONS SHALL BE REQUESTED IN WRITING PRIOR TO ANY INSTALLATION. INCORRECT INSTALLATIONS SHALL BE
CORRECTED AT NO ADDITIONAL COST TO ODOT.
5. ALL WORK SHOWN IS TO BE BY THE CONTRACTOR UNLESS SPECIFICALLY NOTED AS BEING BY ODOT OR BY OTHERS. ALL MATERIALS SHOWN ARE TO BE PROVIDED BY THE CONTRACTOR UNLESS SPECIFICALLY NOTED AS EXISTING OR
PROVIDED BY ODOT.
6. DRAWINGS ARE SCHEMATIC IN NATURE. MAJOR COMPONENTS AND EQUIPMENT ARE SHOWN ON THE DRAWINGS.
CONTRACTOR SHALL SUPPLY AND INSTALL ALL MINOR COMPONENTS AND MATERIALS NECESSARY TO PROVIDE A COMPLETE AND FUNCTIONAL PROJECT WHETHER OR NOT ALL SUCH COMPONENTS ARE NOTED IN THE DRAWINGS AND
SPECIFICATIONS.
7. PLANS AND SPECIFICATIONS CALL OUT SPECIFIC BASIS OF DESIGN PRODUCTS IN SOME LOCATIONS. SUBSTITUTION REQUESTS SHALL BE MADE DURING THE BID PROCESS. ODOT SHALL AT ITS SOLE DISCRETION DETERMINE THE ACCEPTABILITY OF SUBSTITUTIONS. NO SUBSTITUTIONS SHALL BE INSTALLED WITHOUT PRIOR WRITTEN APPROVAL FROM
THE ODOT CONSTRUCTION PROJECT MANAGER.
8. ALL EQUIPMENT AND MATERIALS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S PUBLISHED
INSTALLATION INSTRUCTIONS AND RECOMMENDATIONS.
9. CLEAN ENTIRE WORK AREA AT CONCLUSION OF PROJECT TO THE SATISFACTION OF THE ODOT PROJECT MANAGER.
GENERAL CONSTRUCTION NOTES
T101 TITLE SHEET
A101 SITE PLAN AND ROOF PLAN
A102 DETAILS
SHEET INDEX
0 200'
LOCAL VICINITY PLAN
SCALE: 1" = 200'
STATE VICINITY MAP
SCALE: N.T.S.
TITLE SHEET T101
DAVIS
SLOUGH
CODE INFORMATION:
S-1 OCCUPANCY
TYPE OF CONSTRUCTION: V-B
MAINTENANCE BUILDING: ±6,237 SF
STORAGE BUILDING: ±4,109 SF
ELECTRICAL BUILDING: ±1,488 SF
TO COOS BAY - 5.2 MILES
TO BANDON - 19 MILES
SCOPE OF WORK:
MAINTENANCE BLDG #01: REMOVE EXISTING METAL ROOFING PANELS AND
INSULATION. INSTALL NEW METAL ROOFING PANELS.
ELECTRICAL STORAGE BLDG #03: REMOVE EXISTING METAL PANEL AND
VAPOR BARRIER AS REQUIRED. INSTALL NEW METAL ROOFING PANELS AND
VAPOR BARRIER IN AREA #1. AREA #2 AND AREA #3 INSTALL NEW METAL
ROOFING PANELS.
STORAGE BLDG #04: REMOVE EXISTING METAL ROOFING PANELS AND
INSULATION. INSTALL NEW METAL ROOFING PANELS OVER NEW
CONDENSATION BLANKET INSULATION.
STORAGE BUILDING #04
F4061304
HAZMAT STORAGE
F4060306
OFFICE BLDG.
F4061308
MAINTENANCE
BUILDING #01
F4060301
ELECTRICAL
STORAGE #03
F4061303
PUMP HOUSE
F4061307
O
RE
G O
N
CO
AS
T
HW
Y
SAND
±24'
±62'
±80'±12'±21'
±60'
±28'
±100'
±8'
±23' ±30' ±46'
±26'
±22'
±14'
±13'
±24'
±50'
±6'
NOTE 2
NOTE 1
NOTE 2
NOTE 3NOTE 4
NOTE 5
NOTE 4
NOTE 5
NOTE 6
A102
A102
RIDGE CAP,
SEE DETAIL
A102
A102
A102
A102
A102
NOTE 7
A102
A102
A102
A102
A102
A102
A102
A102
A102
A102
A102
A102
NOTE 1
NOTE 8
AREA #1
AREA #1
AREA #2 AREA #3
SIM
NOTE 9
A102
A102
SIM
REDUCED 50%
WHEN PRINTED
AT 11" x 17"
TH
IS
D R
AW
IN
G
IS
R
ED
U C
ED
IF
B O
R D
ER
IS
N O
T
/2
" x
2"
F40613
ODOT DAVIS SLOUGH MAINTENANCE STATION
ROOF REPLACEMENTS
61036 US-101, COOS BAY, OR 97420 3
09/30/26
FRANCO
SITE PLAN AND ROOF PLAN A101
0 30'
SITE PLAN
SCALE: 1" = 30'
MAINTENANCE BUILDING ROOF PLAN #01
SCALE: 3/32" = 1'-0"
NOTE: EXISTING ROOF PENETRATIONS
TO REMAIN UNLESS OTHERWISE NOTED
IN THE DRAWINGS OR BY THE
CONSTRUCTION PROJECT MANAGER.
PROVIDE NEW WEATHERTIGHT SEALS
AT ALL PENETRATIONS.
ELECTRICAL STORAGE ROOF PLAN #03
SCALE: 3/32" = 1'-0"
STORAGE BUILDING ROOF PLAN #04
SCALE: 3/32" = 1'-0"
NOTES:
1. REMOVE RIDGE VENTS.
2. INSTALL INSULATED METAL PANELS.
3. INSTALL 1" SNAPLOCK STANDING
SEAM METAL PANELS OVER NEW
UNDELAYMENT.
4. INSTALL THOUGHT-THE-ROOF FASTER
STYLE METAL PANELS.
5. INSTALL 1" SNAPLOCK STANDING
SEAM METAL PANEL OVER NEW
UNDELAYMENT.
6. INSTALL THROUGH-THE-ROOF FASTER
STYLE METAL PANEL OVER NEW
BLANKET INSULATION.
7. REPLACE ALL GUTTERS AND
DOWNSPOUTS AROUND THE
MAINTENANCE BUILDING #01 ONLY.
8. REMOVE EXISTING VEHICLE EXHAUST
ROOF VENT AND RE-DUCT TO
SOUTHWEST WALL, INSTALL NEW
WEATHER PROTECTED WALL COVER.
9. FLASH ALL TRANSITIONS WEATHER
TIGHT.
CONTINUOUS "BIRD BLOCK"
PER IMP MFGR
3"
ROOF PANEL CLIP WITH
FASTENING PER IMP MFGR.
GUTTER HANGER
FASTENER PER IMP MFGR.
GUTTER
TRIM
BUTYL TAPE
SEALANT STRIP
UNDER GUTTER
STRAP
EXISTING
EAVE STRUT
EXISTING METAL WALL PANEL
OUTSIDE FOAM CLOSURE
TO FIT EXISTING METAL
WALL PANEL PROFILE
RAKE FASCIA
REMOVE STANDING SEAM
OVERLAP AS REQUIRED
STANDING SEAM TRIM
SUPPORT PER IMP MFGR.
POP RIVET PER
IMP MFGR.
FASTENING PER
IMP MFGR.
BUTYL TAPE SEALANT
PER IMP MFGR.
EXISTING PURLIN
BUTYL TAPE SEALANT
PER IMP MFGR.
EXISTING METAL
WALL PANEL
ROOF PANEL CLIP WITH
FASTENING PER IMP MFGR.
FASTEN PER IMP MFGR.
OUTSIDE CLOSURE
STRIP SET IN BUTYL
TAPE SEALANT AT
TOP AND BOTTOM
METAL CLOSURE SET
IN BUTYL TAPE
SEALANT AT TOP AND
BOTTOM
FASTENING
PER IMP MFGR.
FILL GAP CONTINUOUSLY
WITH TWO-PART
FOAMED-IN-PLACE
URETHANE
EXISTING
PURLIN, TYP.
BUTYL TAPE SEALANT
OUTSIDE RIDGE
INSIDE RIDGE
EXISTING
FRAMING
METAL ROOFING PER
NOTES ON A101
EAVE
FLASHING
EXISTING WOOD
FRAMING
NEW GUTTER,
WHERE REQUIRED
METAL ROOFING PER
NOTES ON A101
METAL
EDGE TRIM
NEW UNDERLAYMENT
CLOSURE
METAL ROOFING PER
NOTES ON A101
EAVE
FLASHING
EXISTING WOOD
FRAMING EXISTING GUTTER
NEW CONDENSATION
BLANKET INSULATION
EXISTING
FRAMING
NEW CONDENSATION
BLANKET INSULATION
METAL ROOFING PER
NOTES ON A101
METAL
EDGE TRIM
CLOSURE
REDUCED 50%
WHEN PRINTED
AT 11" x 17"
TH
IS
D R
AW
IN
G
IS
R
ED
U C
ED
IF
B O
R D
ER
IS
N O
T
/2
" x
2"
F40613
ODOT DAVIS SLOUGH MAINTENANCE STATION
ROOF REPLACEMENTS
61036 US-101, COOS BAY, OR 97420 3
09/30/26
FRANCO
DETAILS A102
ROOF EDGE DETAIL
SCALE: 3" = 1'-0"
3EAVE DETAIL
SCALE: 3" = 1'-0"
A102 A102
ROOF RIDGE DETAIL
SCALE: 3" = 1'-0"
A102
WOOD FRAME EAVE DETAIL
SCALE: 3" = 1'-0"
A102
WOOD FRAME ROOF EDGE DETAIL
SCALE: 3" = 1'-0"
A102
WOOD FRAME EAVE DETAIL
SCALE: 3" = 1'-0"
A102
WOOD FRAME ROOF EDGE DETAIL
SCALE: 3" = 1'-0"
A102
| F40613 - 03_DAVIS SLOUGH MS ROOF REPLACEMENTS_PLAN T101.pdf |
| F40613 - 03_DAVIS SLOUGH MS ROOF REPLACEMENTS_PLAN A101.pdf |
| F40613 - 03_DAVIS SLOUGH MS ROOF REPLACEMENTS_PLAN A102.pdf |
File details come from the government source that posted it. Updated .