Exhibit 10 - 1 Oct 20.pdf

PDF 104 KB Posted

Attached to
Job Order Contract - Minor Construction and Repair of Facilities
Solicitation number
W911S8-21-R-0003
Issued by

About this file

This solicitation notice is for a single-award Indefinite Delivery Indefinite Quantity Job Order Contract for real property sustainment, restoration, and modernization minor construction projects at Joint Base Lewis-McChord in Washington state. The contract has a one-year base period and four one-year option periods, with a total estimated value of $50 million. Task orders will range from $2,000 to $1 million. The North American Industry Classification System code is 236220 and the small business size standard is $39.5 million. Competition is limited to qualified 8(a) firms with a bona fide office in the Seattle District. The contract will be awarded on or around October 1, 2021 to support the U.S. Army Directorate of Public Works at Joint Base Lewis-McChord, Yakima Training Center, Fort Lawton Cemetery, and Fort Worden Cemetery.

View the file

Other files

File Type Posted
W911S8-21-R-0003 Amendment 0008.pdf PDF
Exhibit 39 - Coefficient Schedule rev 6 Aug 21.docx DOCX document
Exhibit 09 - 6 Aug 21.pdf PDF
Attachment 04 Notional Task Order Requirements - JOC W911S8-21-R-0003 JBLM rev. 6 Aug 2021.pdf PDF
W911S8-21-R-0003 Amendment 0007.pdf PDF
Attachment 05 Coefficient Development - JOC 6 Aug 2021.xlsx XLSX spreadsheet
JOC QAs with Consolidated Responses 12 Aug 2021.pdf PDF
Exhibit 01 - General Requirements - rev 6 Aug 21.pdf PDF
W911S8-21-R-0003-0006.pdf PDF
W911S8-21-R-0003-0005.pdf PDF
W911S8-21-R-0003-0004.pdf PDF
W911S8-21-R-0003 0003.pdf PDF
W911S8-21-R-0003 0002.pdf PDF
Exhibit 36 - Pierce Co WD - 2 Apr 21.pdf PDF
Exhibit 38 - Jefferson Co WD - 2 Apr 21.pdf PDF
W911S8-21-R-0003 0001.pdf PDF
Exhibit 35 - King Co WD - 2 Apr 21.pdf PDF
Exhibit 14 - 1 Oct 20.pdf PDF
Attachment 05 Coefficient Development - JOC 20201026.xlsx XLSX spreadsheet
Exhibit 21 - 1 Oct 20.pdf PDF
Exhibit 03 - 1 Oct 20.pdf PDF
Exhibit 12 - 1 Oct 20.pdf PDF
Exhibit 19 - 1 Oct 20.pdf PDF
Exhibit 37 - Yakima Co WD - 22 Jan 21.pdf PDF
Exhibit 23 - 1 Oct 20.pdf PDF
Exhibit 04 - 1 Oct 20.pdf PDF
Exhibit 08 - 1 Oct 20.pdf PDF
Exhibit 27 - 1 Oct 20.pdf PDF
Exhibit 22 - 1 Oct 20.pdf PDF
Exhibit 39 - 9 Oct 20.pdf PDF
Exhibit 07 - 1 Oct 20.pdf PDF
Attachment 03 Past Performance Questionnaire - JOC W911S8-21-R-0003 JBLM 20210202.pdf PDF
Exhibit 17 - 1 Oct 20.pdf PDF
Exhibit 24 - 1 Oct 20.pdf PDF
Exhibit 25 - 1 Oct 20.pdf PDF
Exhibit 33 - Mar 2014.pdf PDF
Exhibit 05 - 1 Oct 20.pdf PDF
Exhibit 35 - King Co WD - 26 Feb 21.pdf PDF
Exhibit 15 - 1 Oct 20.pdf PDF
Exhibit 34 - ENG Form 4288-R.xlsx XLSX spreadsheet
Exhibit 13 - 1 Oct 20.pdf PDF
Exhibit 26 - 1 Oct 20.pdf PDF
Attachment 01 Consent Letter - JOC W911S8-21-R-0003 JBLM 20201026.docx DOCX document
Exhibit 32 - 1 Oct 20.pdf PDF
Solicitation_W911S821R0003_Job Order Contract_JBLM_2 April 2021.pdf PDF
Exhibit 36 - Pierce Co WD - 29 Jan 21.pdf PDF
Exhibit 02 - 1 Oct 20.pdf PDF
Exhibit 16 - 1 Oct 20.pdf PDF
Attachment 04 Notional Task Order Requirements - JOC W911S8-21-R-0003 JBLM 20201026.pdf PDF
Exhibit 29 - 1 Oct 20.pdf PDF
Show 40 more

Latest 50 of 63 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SECTION 10 10 00 Page 1

SECTION 10 10 00

VISUAL COMMUNICATIONS SPECIALTIES

PART 1 GENERAL

1.1 REFERENCES

The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.

AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI)

ANSI Z97.1 (2004) Safety Glazing Materials Used in Buildings

ASTM INTERNATIONAL (ASTM)

ASTM B 221 (2006) Standard Specification for Aluminum and

Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and Tubes

ASTM C 1048 (2004) Standard Specification for Heat-Treated Flat

Glass - Kind HS, Kind FT Coated and Uncoated Glass

ASTM E 84 (2008a) Standard Test Method for Surface Burning

Characteristics of Building Materials

ASTM F 148 (2002; r 2007) Binder Durability of Cork Composition

Gasket Materials

ASTM F 152 (1995; R 2002) Tension Testing of Nonmetallic Gasket

Materials

ASTM F 793 (2007) Wall Covering by Durability Characteristics

1.2 SUBMITTALS

Government approval is required for submittals with a "G" designation;

submittals not having a "G" designation are for information only. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government. The following shall be submitted in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:

SD-03 Product Data

Visual Display Boards; G

Manufacturer's descriptive data and catalog cuts. Manufacturer's installation instructions, and cleaning and maintenance instructions.

For Fiberboard submit manufacturer documentation indicating type of recovered material and the percentage of such material that is recovered. Alternately, submit written justification of non-use per Section 01 62 35 RECYCLED/RECOVERED MATERIALS.

SECTION 10 10 00 Page 2

Submit manufacturer documentation demonstrating type and percentage of biobased content or written justification of non-use per Paragraph 2.5.

SD-04 Samples

Aluminum; G

Sections of frame, map rail, and chalk tray, and map hooks.

Porcelain Enamel; G

Section showing porcelain enamel coating, steel, core material and backing.

Materials; G

Section of core material showing the lamination of colored cork, natural cork, woven fabric, non-woven fabric, and vinyl wall covering. Sample of hardwood and plastic laminate finish, and glass type. Samples shall be minimum 4 by 4 inches and show range of color.

SD-07 Certificates

Visual Display Boards

Certificate of compliance signed by contractor attesting that visual display boards conform to the requirements specified.

1.3 VISUAL DISPLAY BOARDS

The term visual display board when used herein includes presentation boards, marker boards, tack boards, board cases, display track system and horizontal sliding units. Visual display boards shall be from manufacturer's standard product line.

1.4 DELIVERY, STORAGE AND HANDLING

Materials shall be delivered to the building site in the manufacturer's original unopened containers and shall be stored in a clean dry area with temperature maintained above 50 degrees F. Materials shall be stacked according to manufacturer's recommendations. Visual display boards shall be allowed to acclimate to the building temperature for 24 hours prior to installation.

1.5 WARRANTY

Manufacturer's standard performance guarantees or warranties that extend beyond a one year period shall be provided.

PART 2 PRODUCTS

2.1 COLOR

Finish colors for required items shall be as specified in Section 09 06 90

COLOR SCHEDULE.

SECTION 10 10 00 Page 3

2.2 MATERIALS

2.2.1 Porcelain Enamel

Marker board writing surface shall be composed of porcelain enamel fused to a nominal 28 gauge (0.0149 inches) thick steel, laminated to a minimum 1/4 inch thick core material with a steel or foil backing sheet. Writing surface shall be capable of supporting paper by means of magnets. Marker board surface for display track system may be a powder paint dry erase surface adhered to a nominal 18 gauge (0.0478 inches) thick steel.

2.2.2 Cork

Cork shall be a continuous resilient sheet made from soft, clean, granulated cork relatively free from hardback and dust and bonded with a binder suitable for the purpose intended. The wearing surface shall be free from streaks, spots, cracks or other imperfections that would impair its usefulness or appearance. The material shall be seasoned, and a clean cut made not less than 1/2 inch from the edge shall show no evidence of soft sticky binder.

2.2.2.1 Colored Cork

Colored cork shall be composed of pure cork and natural color pigments that are combined under heat and pressure with linseed oil. Colored cork shall be colored throughout and shall be washable. The burlap backing shall be deeply imbedded and keyed to the work sheet being partially concealed in it and meeting the requirements of ASTM F 148.

2.2.2.2 Natural Cork

Material shall be a single layer of pure grain natural cork without backing or facing. The color shall be light tan. The cork sheet shall have a tensile strength of not less than 40 psi when tested in accordance with ASTM F 152.

2.2.3 Woven Fabric

Fabric shall be plain weave. Fiber content shall be 100 percent polyester.

Minimum total weight shall be 16 oz. plus or minus 0.5 oz. per lineal yard.

Fabric shall have a Class A flame spread rating of 0-50 and smoke development rating of 0-450 in accordance with ASTM E 84.

2.2.4 Non-Woven Fabric

Fabric shall be non-woven and hooktape compatible. Fiber content shall be 100 percent polyester, 100 percent polyolefin or 100 percent nylon, backed.

Minimum total weight shall be 11 oz. plus or minus 0.5 oz. per lineal yard for 60 inch wide fabric. Fabric shall have a Class A flame spread rating of 0-50 and smoke development rating of 0-450 in accordance with ASTM E 84.

2.2.5 Vinyl Wall Covering

Vinyl wall covering shall conform to ASTM F 793, Category V. Vinyl wall covering shall have a Class A flame spread rating of 0-50 and smoke development rating of 0-450 in accordance with ASTM E 84.

SECTION 10 10 00 Page 4

2.2.6 Aluminum

Aluminum frame extrusions shall be alloy 6063-T5 or 6063-T6, conform to ASTM B 221, and be a minimum 0.06 inches thick. Exposed aluminum shall have an anodized, satin finish. Straight, single lengths shall be used wherever possible. Joints shall be kept to a minimum. Corners shall be mitered and shall have a hairline closure.

2.2.7 Hardwood

Exposed hardwood for frames, cabinets, and cases shall be oak, walnut or mahogany. Hardwood shall be provided with a durable factory-applied stain and lacquer finish of a type standard with the manufacturer.

2.2.8 Glass

Glass shall be comprised of tempered glass in accordance with ANSI Z97.1 and shall conform to ASTM C 1048, Kind FT (fully tempered), Condition A (uncoated), Type I, Class I (clear), thickness as specified.

2.3 PRESENTATION BOARD

The presentation board shall be a wall hung cabinet with lockable double doors or single door as indicated and shall have a projection screen, if indicated, that pulls down over the marker board writing surface in the cabinet interior. The doors shall be attached to cabinet with piano hinges and have a catch or closure to keep doors closed when not in use. The interior of the cabinet shall contain a porcelain enamel marker board writing surface with chalk tray, a flip chart that can be hung on an interior door panel, and fabric covered tack surface on the interior door panels. The cabinet shall be oak, walnut, mahogany, or plastic laminate (as indicated). The edge detailing shall be rectilinear. Dry erase markings shall be removable with a felt eraser or dry cloth without ghosting. Each unit shall come complete with an eraser and four different color compatible dry erase markers. Two keys shall be provided for each unit. The size shall be as shown in the drawings.

2.4 MARKERBOARD

Marker board shall have a porcelain enamel writing surface and a chalk tray.

Marker board shall be a factory assembled unit complete in one piece, without joints whenever possible. When marker board dimensions require delivery in separate sections, components shall be prefit at the factory, disassembled for delivery and jointed at the site. Frame shall be oak, walnut, mahogany, or aluminum as indicated. Chalk tray shall be the same material as the frame and extend the full length of the liquid marker board.

The marker board shall have a map rail, if indicated. The map rail with a tackable insert shall extend the full length of the liquid chalkboard, and shall have map hooks with clips for holding sheets of paper. Two map hooks shall be provided for each 4 foot of map rail. Dry erase markings shall be removable with a felt eraser or dry cloth without ghosting. Each unit shall come complete with an eraser and four different color compatible dry erase markers. The size shall be as shown in the drawings.

2.5 TACKBOARDS

SECTION 10 10 00 Page 5

If insulation board is made of composite panels (including composite fiberboard), it should comply with the following requirement:

Composite panels such as particleboard or medium density fiberboard shall comply with biobased content requirements established by the USDA's BioPreferred program unless the designer, requirements generator, or contractor determines that no biobased product can be obtained within the cost, performance, or availability requirements of the contract. If such determination of non-use is made, the contractor or subcontractor shall complete and submit the Joint Base Lewis-McChord Construction Green Procurement Exception Form. Using this form, the contractor shall specify the reason for exception (unreasonable price, inadequate performance, non-availability) and provide all associated information (including copies of all supporting evidence). This form is available from the contracting official or the Joint Base Lewis-McChord Green Procurement Program Coordinator (Building 1210, (253) 966-6466, LEWISPWGreenProcurement@conus.army.mil). The contractor shall submit the completed form via e-mail (with copies of supporting documents included) to the Contracting Officer's Representative. The contractor shall include the following address in the carbon copy ("cc") line of the e-mail:

LEWISPWGreenProcurement@conus.army.mil. The contractor shall keep attached file sizes to a minimum to avoid transmission errors associated with Joint Base Lewis-McChord security. If use of e-mail is not possible, the contractor shall coordinate the submission of these documents with the Contracting Officer's Representative and ask that they forward copies to the Joint Base Lewis-McChord Green Procurement Coordinator (Bldg 1210, 966- 6466). More information can be found at http://www.biopreferred.gov/ProposedAndFinalRegulations.aspx.

2.5.1 Cork

Tack board shall consist of a minimum 1/8 inch thick colored cork with burlap backing laminated to a minimum 3/8 inch thick insulation board or fiber board, and shall have an oak or aluminum frame as indicated. The size

2.5.2 Vinyl Covered

Tack board shall have a vinyl wall covering laminated to a minimum 1/8 inch thick cork laminated to a minimum 3/8 inch thick insulation board or fiberboard, and shall have an oak, aluminum frame as indicated. The size

2.5.3 Fabric Covered

Tack board shall have a woven or non-woven fabric covering laminated to a minimum 1/8 inch thick cork laminated to a minimum 3/8 inch thick insulation board or fiberboard, and shall have an oak or aluminum frame as indicated.

The size shall be as shown on the drawings.

2.6 CASE FOR BOARD UNIT

The case for the board unit shall be surface or recess mounted and have hinged minimum 3/16 inch thick or sliding minimum 1/4 inch thick tempered glass doors that are lockable. Case shall be aluminum or oak as indicated.

Mitered corners shall be reinforced for rigidity. Doors shall be equipped with continuous piano hinges. Door glass shall be framed with the case

SECTION 10 10 00 Page 6 material, and be reinforced at all corners. Door framing shall not depend upon the glass for rigidity. Multiple door cases shall have an elbow catch.

Sliding doors if indicated shall have aluminum "H" molding at top and bottom of case. The interior side of the back panel shall be tackable and shall be composed of a minimum 1/4 inch colored cork; a minimum 1/4 inch natural cork; or a vinyl wall covering laminated to a minimum 1/4 inch cork laminated to a minimum 1/4 inch fiberboard. Two keys shall be provided for each unit. The size shall be as shown on the drawings.

2.7 DISPLAY TRACK SYSTEM

This method of display shall be a flexible and interchangeable system that consists of lightweight presentation components suspended from a wall mounted, linear, horizontal track. Track shall have the number of levels indicated to attach components. Track shall allow attached components to slide horizontally. Presentation components shall be capable of being lifted from the track and being relocated to allow for reconfiguration.

Components shall be capable of being installed on the track without the use of tools for installation, removal, and reconfiguration. The presentation components shall consist of a retractable projection screen, tilted projection screen (top tilts forward), reversible panel with dry erase marker board on both sides, reversible panel with marker board on one side and woven fabric covered tack surface on the other, removable shelf, panel with adjustable flipchart, and display rail for setting presentation materials or a holder for displaying maps, presentation boards, drawings and other paper display materials up to a 1/8 inch thickness. Components shall be installed and located on track in accordance with manufacturer recommendations. Marker boards shall be provided with a marker tray.

Marker board surface shall accept magnets. Dry erase markings on the marker board shall be removable with a felt eraser or dry cloth without ghosting.

Each unit shall come complete with an eraser and four different color compatible dry erase markers. The sizes shall be as shown in the drawings.

Track and trim materials shall be standard products of the manufacturer.

2.8 HORIZONTAL SLIDING UNITS

The horizontal sliding unit shall be composed of a fixed back panel, sliding panels, an aluminum track assembly, and shall have a map rail and chalk tray. The unit shall have number of tracks indicated. The fixed back panel shall be marker board or tack board. The unit shall have marker board sliding panel and tack board sliding panels as shown. The track assembly and exposed members, including panel edging and chalk tray, shall be extruded aluminum. Frame assembly shall be reinforced at corners. Sliding panels shall be suspended from the top and shall slide over the aluminum track using molded nylon ball bearing rollers at the top of the track and nylon guide rollers at the bottom of the track to eliminate vibration and to provide quiet and smooth operation of the panels. Sliding panels shall have finger pulls at each end. The map rail shall have a tackable insert and extend the length of the horizontal sliding unit. The map rail shall have map hooks with clips for holding sheets of paper. Two map hooks shall be provided for each 4 foot of map rail. Chalk tray shall extend the full length of the horizontal sliding unit. Dry erase markings on the marker board shall be removable with a felt eraser or dry cloth without ghosting.

Each unit shall come complete with an eraser and four different color compatible dry erase markers. The size shall be as shown in the drawings.

SECTION 10 10 00 Page 7

2.9 COPYBOARD

The copy board shall be wall mounted, 120V, UL listed, and have a 2 sided rotating screen, and capability to save and print to a government furnished and government installed PC and printer. Copy board surface shall have grid lines and accept dry erase markers. Dry erase markings shall be removable with a felt eraser or dry cloth without ghosting. Copy board shall be PC ready. PC interface kit shall be provided for each PC ready unit. Copy boards shall be hardwired or have an electrical cord that plugs into an electrical wall outlet as indicated. Electrical work shall conform to requirements of Section 26 20 00 INTERIOR DISTRIBUTION SYSTEM. Each copy board shall come complete with an eraser and three different color compatible dry erase markers. The size shall be as shown in the drawings.

2.10 PROJECTION SCREEN

Wall, ceiling, or recessed mounted motorized projection screen shall have 120V motor that is lubricated for life, quick reversal type, has overload protector, integral gears, and preset accessible limit switches. Recessed mount projection screens shall have an operable closure door and access panel. Screen shall be flame retardant, mildew resistant, and glass beaded white matte with black masking borders tab tensioned. Tab tensioned screens shall have a vinyl surface that is stretchable. Bottom of screen fabric shall be weighted with metal rod. Roller shall be a rigid metal at least 3 inches in diameter mounted on sound absorbing supports. Motor will be end mounted or motor-in-roller design. Screen shall have a 3 position control switch to stop or reverse screen at any point. The switch shall be installed in a flush electrical box with cover plate, location(s) as shown on the electrical drawings. All conduit and wiring from the control switch to the projection screen shall be furnished and installed by the contractor.

Ceiling recessed case shall be extruded aluminum. Wall or ceiling mounted case shall be aluminum or steel. Screen shall be UL listed. The size

PART 3 EXECUTION

3.1 PLACEMENT SCHEDULE

Location and mounting height of visual display boards shall be as shown on the drawings.

Mounting height is defined as distance from finished floor to top of the display board frame.

3.2 INSTALLATION

Installation and assembly shall be in accordance with manufacturer's printed instructions. Concealed fasteners shall be used. Visual display boards shall be attached to the walls with suitable devices to anchor each unit.

The contractor shall furnish and install trim items, accessories and miscellaneous items in total, including but not limited to hardware, grounds, clips, backing materials, adhesives, brackets, and anchorages incidental to or necessary for a sound, secure, complete and finished installation. Installation shall not be initiated until completion of room painting and finishing operations. Visual display boards shall be installed in locations and at mounting heights indicated. Visual display boards shall be installed level and plumb, and if applicable doors shall be aligned and

SECTION 10 10 00 Page 8 hardware shall be adjusted. Damaged units shall be repaired or replaced by the contractor as directed by the Contracting Officer.

3.3 CLEANING

Writing surfaces shall be cleaned in accordance with manufacturer's instructions.

-- End of Section --

SECTION 10 14 01 Page 1

SECTION 10 14 01

EXTERIOR SIGNAGE

The publications listed below form a part of this specification to the

ALUMINUM ASSOCIATION (AA)

AA DAF-45 (2003) Designation System for Aluminum Finishes

AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI)

ANSI Z97.1 (2004) Safety Glazing Materials Used in Buildings

AMERICAN WELDING SOCIETY (AWS)

AWS C1.1M/C1.1 (2000; R 2006) Resistance Welding

AWS D1.1/D1.1M (2008) Structural Welding Code - Steel

AWS D1.2/D1.2M (2008) Structural Welding Code - Aluminum

ASTM A 1011/ (2008) Standard Specification for Steel, Sheet, and A 1011M Strip, Hot-Rolled, Carbon, Structural, High-Strength

Low-Alloy and High-Strength Low-Alloy with Improved Formability

ASTM A 123/A 123M (2008) Standard Specification for Zinc (Hot-Dip

Galvanized) Coatings on Iron and Steel Products

ASTM A 36/A 36M (2008) Standard Specification for Carbon Structural

Steel

ASTM A 653/A 653M (2008) Standard Specification for Steel Sheet, Zinc-

Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process

ASTM A 924/A 924M (2008a) Standard Specification for General

Requirements for Steel Sheet, Metallic-Coated by the Hot-Dip Process

ASTM B 108 (2006) Standard Specification for Aluminum-Alloy

Permanent Mold Castings

ASTM B 209 (2007) Standard Specification for Aluminum and

Aluminum-Alloy Sheet and Plate

ASTM B 221 (2006) Standard Specification for Aluminum and

SECTION 10 14 01 Page 2

ASTM B 26/B 26M (2005) Standard Specification for Aluminum-Alloy Sand

Castings

ASTM B 62 (2002) Standard Specification for Composition Bronze or Ounce Metal Castings

ASTM C 1036 (2006) Standard Specification for Flat Glass

ASTM D 3841 (1997e1; R 2008) Standard Specification for Glass

Fiber-Reinforced Polyester Plastic Panels

ASTM E 84 (2008a) Standard Test Method for Surface Burning

Characteristics of Building Materials

NATIONAL ASSOCIATION OF ARCHITECTURAL METAL MANUFACTURERS (NAAMM)

NAAMM AMP 500 (2006) Metal Finishes Manual

NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)

NFPA 70 (2007; AMD 1 2008) National Electrical Code - 2008 Edition

SOCIETY OF AUTOMOTIVE ENGINEERS INTERNATIONAL (SAE)

SAE AMS3611 (1994; Rev D; R 2003) Plastic Sheet, Polycarbonate

General Purpose

1.2 SUBMITTALS

Government approval is required for submittals with a "G" designation;

submittals not having a "G" designation are for information only. When used, a designation following the "G" designation identifies the office that

SD-02 Shop Drawings

Approved Detail Drawings; G

Drawings showing elevations of each type of sign; dimensions, details, and methods of mounting or anchoring; shape and thickness of materials; and details of construction. A schedule showing the location, each sign type, and message shall be included.

Modular Exterior Signage System

Manufacturer's descriptive data and catalog cuts.

Installation

Manufacturer's installation instructions and cleaning

SECTION 10 14 01 Page 3

Exterior Signage; G

Exterior signage schedule in electronic media with spread sheet format. Spread sheet shall include sign location, sign type, and message.

Submit manufacturer documentation indicating the type of recovered materials and the percentage of such material that is (1) recovered and (2) post-consumer recycled content. This includes plastic or steel posts and supports. Alternately, submit written justification of non-use per Section 01 62 35 RECYCLED/RECOVERED MATERIALS.

Concrete

Submit manufacturer documentation indicating the type of recovered material and the total percentage of such material that is recovered. Alternately, submit written justification of non-use per Section 01 62 35 RECYCLED/RECOVERED MATERIALS

Wind Load Requirements

Design analysis and supporting calculations performed in support of specified signage.

Exterior Signage; G

One 12 inch length of framing for illuminated signs. One sample of each type of sign. Each sample shall consist of a complete sign panel with letters and symbols. Samples may be installed in the work, provided each sample is identified and location recorded.

Three color samples for each material requiring color and 12 inch square sample of sign face color sample.

SD-10 Operation and Maintenance Data

Protection and Cleaning

Six copies of maintenance instructions listing routine maintenance procedures, possible breakdowns and repairs, and troubleshooting guides. The instructions shall include simplified diagrams for the equipment as installed.

1.3 GENERAL

All exterior signage shall be provided by a single manufacturer. Exterior signage shall be of the design, detail, sizes, types, and message content shown on the drawings, shall conform to the requirements specified, and shall be provided at the locations indicated. Signs shall be complete with lettering, framing as detailed, and related components for a complete installation. Recyclable materials, including concrete and posts/supports, shall conform to EPA requirements in accordance with Section 01 62 35

RECYCLED/RECOVERED MATERIALS.

1.4 WIND LOAD REQUIREMENTS

SECTION 10 14 01 Page 4

Exterior signage shall be designed to withstand 90 mph wind load.

1.5 CHARACTER PROPORTIONS AND HEIGHTS

Letters and numbers on indicated signs for handicapped-accessible buildings shall have a width-to-height ratio between 3:5 and 1:1 and a stroke-width-to-height ratio between 1:5 and 1:10. Characters and numbers on indicated signs shall be sized according to the viewing distance from where they are to be read. The minimum height is measured using an upper case letter "X".

Lower case characters are permitted.

1.6 QUALIFICATIONS

Signs, plaques, and dimensional letters shall be the standard product of a manufacturer regularly engaged in the manufacture of the products. Items of equipment shall essentially duplicate equipment that has been in satisfactory use at least 2 years prior to bid opening.

1.7 DELIVERY AND STORAGE

Materials shall be wrapped for shipment and storage, delivered to the jobsite in manufacturer's original packaging, and stored in a clean, dry area in accordance with manufacturer's instructions.

1.8 WARRANTY

beyond a one year period shall be provided.

1.9 EXTRA STOCK

The contractor shall provide extra interchangeable message panels and extra stock as indicated on the Delivery Order.

2.1 MODULAR EXTERIOR SIGNAGE SYSTEM

Exterior signage shall consist of a system of coordinated directional, identification, and regulatory type signs located where shown. Dimensions, details, materials, message content, and design of signage shall be as shown.

2.1.1 Free-Standing Base Mount Pylon/Monolith Type Signs

2.1.1.1 Framing

Interior framing shall consist of aluminum or galvanized steel, as indicated, tube columns welded to companion plates. Perimeter framing shall consist of aluminum or steel, as indicated, angle framing welded to the post and plate system as designed. Framing members shall be designed to permit access to electrical equipment and panel removal. Mounting shall be provided as shown. Framing members of steel shall be finished with semi-gloss baked enamel or two-component acrylic polyurethane. Openings shall be sealed from moisture and made tamper-proof.

SECTION 10 14 01 Page 5

2.1.1.2 Exterior Sheeting Panels

Modular panels shall be provided in sizes shown on drawings. Panels shall be fabricated a minimum of 0.090 inch thick aluminum steel or 0.125 inch thick fiberglass reinforced plastic (FRP) as indicated. Panels shall be heliarc welded to framing system. Top and end panels shall be removable and shall be secured by 3/16 inch socket head jack nuts. Finish for metal panels shall be semi-gloss baked enamel or anodized conforming to AA DAF-45.

2.1.1.3 Mounting

Mounting shall be provided by securing to concrete foundation as shown.

2.1.1.4 Finishes

Base finish shall be semi-gloss baked enamel or anodized conforming to AA DAF-45, as indicated. Metal panel system finish shall be baked enamel or two-component acrylic polyurethane or anodized conforming to AA DAF-45 as indicated.

2.1.2 Panel And Post/Panel Type Signs

2.1.2.1 Posts

One-piece aluminum or galvanized steel posts shall be provided with minimum

0.125 inch wall thickness. Posts shall be designed to accept panel framing system described. The post shall be designed to permit attachment of panel framing system without exposed fasteners. Caps shall be provided for each post.

2.1.2.2 Panel Framing System

Panel framing consisting of aluminum sections and interlocking track components shall be designed to interlock with posts with concealed fasteners.

2.1.2.3 Panels

Modular message panels shall be provided in sizes shown on drawings. Panels shall be fabricated a minimum of 0.125 inch aluminum. Panels shall be designed to be interchangeable. Panels with metal return sheeting shall have welded corners, ground smooth. Face panels shall be removable to provide access to electrical components.

2.1.2.4 Finishes

Post finish shall be semi-gloss baked enamel or anodized conforming to AA DAF-45. Metal panel system finish shall be baked enamel or two-component acrylic polyurethane or anodized conforming to AA DAF-45 as indicated.

2.1.2.5 Mounting

Permanent mounting shall be provided by embedding posts in concrete foundation as shown. If removable mounting is indicated, mounting shall be provided by a steel an aluminum sleeve flange embedded in concrete as shown.

SECTION 10 14 01 Page 6

2.1.3 Changeable Letter Directories

2.1.3.1 Frame and Trim

Aluminum alloy finish.

2.1.3.2 Header Plates

Header plate shall consist of background metal matching frame and having raised letters attached through the back or of acrylic with raised acrylic letters; or header plate shall consist of MP plastic with raised letters.

2.1.3.3 Door Glazing

Door glazing shall be clear safety or tempered glass minimum 1/4 inch thick.

2.1.3.4 Door Construction

Door frame shall be of same material and finish as surrounding frame.

Corners shall be mitered, and assembled with concealed fasteners. Hinges shall be standard with manufacturer, in finish to match frames and trim.

Glazing shall be set in frame with resilient glazing channels.

2.1.3.5 Door Locks

Door locks shall be manufacturer's standard and shall be keyed alike.

2.1.3.6 Fabrication

Frames and trim shall be assembled with corners and mitered to hairline fit, with no exposed fasteners. Removable changeable directory panel shall consist of 1/4 inch thick white acrylic with clear acrylic letter tracks backed with vinyl or corkboard covering backgrooved 1/4 inch on centers to receive letters.

2.1.3.7 Finishes

Post finish shall be semi-gloss baked enamel or anodized conforming to AA DAF-45. Metal panel system finish shall be baked enamel or two-component acrylic polyurethane or anodized conforming to AA DAF-45, as shown.

2.1.3.8 Mounting

Directories shall be mounted to supporting structures with concealed fasteners in accordance with manufacturer's instructions.

2.1.3.9 Changeable Letters

Changeable letters shall be upper-case or upper and lower-case helvetica medium. Tabbed vinyl letters and numbers shall be furnished in accordance with the Delivery Order.

2.2 ILLUMINATION

Concealed lighting shall be provided within panel framing members. Lighting shall be controlled by a photocell device. Top or back lighting shall be provided as indicated in the Delivery Order. Ballast shall be integrally

SECTION 10 14 01 Page 7 mounted, high power factor and rated for use down to minus 20 degrees F ambient starting temperature. Ballast and wiring within the sign shall be in metal raceways. Electrical equipment shall be UL or FM listed and comply with NFPA 70. Illumination shall be evenly distributed. A switch on the interior of the sign shall be provided to turn off power in the sign.

Switch shall be readily accessible when sign is open.

2.3 GRAPHICS FOR EXTERIOR SIGNAGE SYSTEMS

2.3.1 Graphics

See Delivery Order for graphics and message content. Typeface: Helvetica medium. Type size as indicated.

2.4 METAL PLAQUES

Design and location of plaques shall be as shown.

2.4.1 Cast Metal Plaques

2.4.1.1 Fabrication

Cast metal plaques shall have the logo, emblem and artwork cast in the technique indicated. Plaques shall be fabricated from materials indicated.

2.4.1.2 Size

Plaque size shall be as shown.

2.4.1.3 Border

Border shall be as indicated.

2.4.1.4 Background

Background texture shall be leather or fine pebble as indicated.

2.4.1.5 Mounting

Mounting shall be as indicated.

2.4.1.6 Finish

Finishes shall consist of as indicated

2.5 ALUMINUM ALLOY PRODUCTS

Aluminum alloy products shall conform to ASTM B 209 for sheet or plate, ASTM B 221 for extrusions and ASTM B 26/B 26M or ASTM B 108 for castings.

Aluminum extrusions shall be provided at least 1/8 inch thick and aluminum plate or sheet at least 16 gauge thick. Welding for aluminum products shall conform to AWS C1.1M/C1.1.

2.6 ANODIC COATING

Anodized finish shall conform to AA DAF-45 as follows:

SECTION 10 14 01 Page 8

Clear (natural) designation AA-M10-C22-A31, Architectural Class II 0.4 mil or thicker.

Integrated color anodized designation AA-M10-C22-A32, Architectural Class 0.4 to 0.7 mil.

Electrolytically deposited color - anodized designation AA-M10-C22-A34, Architectural Class II 0.4 to 0.7 mil.

2.7 ORGANIC COATING

Surfaces shall be cleaned, primed, and given a semi-gloss baked enamel or two-component acrylic polyurethane finish in accordance with NAAMM AMP 500, AMP 505, with total dry film thickness not less than 1.2 mils.

2.8 STEEL PRODUCTS

Structural steel products shall conform to ASTM A 36/A 36M. Sheet and strip steel products shall conform to ASTM A 1011/A 1011M. Welding for steel products shall conform to AWS D1.2/D1.2M.

2.9 CAST BRONZE

Components shall be fabricated with sharp corners, flat faces, and accurate profiles. Burrs and rough spots shall be removed and polished. Faces shall be finished to a uniform high luster. Cast bronze shall be in accordance with ASTM B 62.

2.10 VINYL SHEETING FOR GRAPHICS

Vinyl sheeting shall be 5 to 7 year premium type and shall be in accordance with the flammability requirements of ASTM E 84 and shall be a minimum 0.003 inch film thickness. Film shall include a precoated pressure sensitive adhesive backing, Class 1, or positionable pressure sensitive adhesive backing, Class 3.

2.11 GLASS

Glass shall be in accordance with ASTM C 1036, Type I, Class 1, Quality q3 and ANSI Z97.1.

2.12 FIBER-REINFORCED POLYESTER (FRP) PANELS

Fiber-reinforced polyester (FRP) shall be in accordance with ASTM D 3841, Type II, Grade 1, Class 124, as indicated.

2.13 ACRYLIC SHEET

Acrylic sheet shall be in accordance with the flammability requirements of ASTM E 84 and shall conform to ANSI Z97.1.

2.14 POLYCARBONATE SHEET

Polycarbonate sheet shall conform to SAE AMS3611.

2.15 ANCHORS AND FASTENERS

SECTION 10 14 01 Page 9

Exposed anchor and fastener materials shall be compatible with metal where applied and shall match in color and finish and shall be non-rusting, non-corroding, and non-staining. Exposed fasteners shall be tamper-proof.

2.16 SHOP FABRICATION AND MANUFACTURE

2.16.1 Factory Workmanship

Work shall be assembled in the shop, as far as practical, ready for installation at the site. Work that cannot be shop assembled shall be given a trial fit in the shop to ensure proper field assembly. Holes for bolts and screws shall be drilled or punched. Drilling and punching shall produce clean, true lines and surfaces. Welding to or on structural steel shall be in accordance with AWS D1.1/D1.1M. Welding shall be continuous along the entire area of contact. Exposed welds shall be ground smooth. Exposed surfaces of work shall have a smooth finish and exposed riveting shall be flush. Fastenings shall be concealed where practical. Items specified to be galvanized shall be by hot-dip process after fabrication if practical.

Galvanization shall be in accordance with ASTM A 123/A 123M and ASTM A 653/A 653M, as applicable. Other metallic coatings of steel sheet shall be in accordance with ASTM A 924/A 924M. Joints exposed to the weather shall be formed to exclude water. Drainage and weep holes shall be included as required to prevent condensation buildup.

2.16.2 Dissimilar Materials

Where dissimilar metals are in contact, or where aluminum is in contact with concrete, mortar, masonry, wet or pressure-treated wood, or absorptive materials subject to wetting, the surfaces shall be protected with a coat of asphalt varnish or a coat of zinc-molybdate primer to prevent galvanic or corrosive action.

2.16.3 Shop Painting

Surfaces of miscellaneous metal work, except nonferrous metal, corrosion resisting steel, and zinc-coated work, shall be given one coat of zinc-molybdate primer or an approved rust-resisting treatment and metallic primer in accordance with manufacturer's standard practice. Surfaces of items to be embedded in concrete shall not be painted. Upon completion of work, damaged surfaces shall be recoated.

2.17 COLOR, FINISH, AND CONTRAST

Color shall be in accordance with Section 09 06 90 COLOR SCHEDULE. Color listed is not intended to limit the selection of equal colors from other manufacturers. For buildings required to be handicapped-accessible, the characters and background of signs shall be eggshell, matte, or other non-glare finish. Characters and symbols shall contrast with their background -either light characters on a dark background or dark characters on a light background.

3.1 INSTALLATION

Signs, plaques, or dimensional letters shall be installed in accordance with approved manufacturer's instructions at locations shown on the approved

SECTION 10 14 01 Page 10 detail drawings. Circuits installed underground shall conform to the requirements of Section 33 70 02.00 10 ELECTRICAL DISTRIBUTION SYSTEM, UNDERGROUND. Steel conduits installed underground and illuminated signage mounted directly on buildings shall be in conformance with the requirements of Section 26 20 00 INTERIOR DISTRIBUTION SYSTEM. Signs shall be installed plumb and true at mounting heights indicated, and by method shown or specified. Signs mounted on other surfaces shall not be installed until finishes on such surfaces have been completed.

3.1.1 Anchorage

Anchorage and fastener materials shall be in accordance with approved manufacturer's instructions for the indicated substrate. Anchorage not otherwise specified or indicated shall include slotted inserts, expansion shields, and powder-driven fasteners when approved for concrete; toggle bolts and through bolts for masonry; machine carriage bolts for steel; lag bolts and screws for wood.

3.1.2 Protection and Cleaning

The work shall be protected against damage during construction. Hardware and electrical equipment shall be adjusted for proper operation. Glass, frames, and other sign surfaces shall be cleaned in accordance with manufacturer's instructions. After signs are completed and inspected, the contractor shall cover all project identification, directional, and other signs that may mislead the public. Covering shall be maintained until instructed to be removed by the Contracting Officer or until the facility is to be opened for business. Signs shall be cleaned, as required, at time of cover removal.

3.2 FIELD PAINTED FINISH

Miscellaneous metals and frames shall be field painted in accordance with Section 09 90 00 PAINTS AND COATINGS. Anodized metals, masonry, and glass shall be protected from paint. Finish shall be free of scratches or other blemishes.

SECTION 10 14 02 Page 1

SECTION 10 14 02

INTERIOR SIGNAGE

The publications listed below form a part of this specification to the extent referenced. The publications are referred to in the text by basic designation only.

AA PK-1 (2008) Pink Sheets: Designations and Chemical

Composition Limits for Aluminum Alloys in the Form of Castings and Ingot

AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA)

AAMA 2604 (2005) Voluntary Specification, Performance

Requirements and Test Procedures for High Performance Organic Coatings on Aluminum Extrusions and Panels

AMERICAN WELDING SOCIETY (AWS)

AWS D1.2/D1.2M (2008) Structural Welding Code - Aluminum

ASTM B 209 (2007) Standard Specification for Aluminum and

Aluminum-Alloy Sheet and Plate

ASTM B 221 (2006) Standard Specification for Aluminum and

ASTM C 1036 (2006) Standard Specification for Flat Glass

1.2 SUBMITTALS

Government approval is required for submittals with a "G" designation;

submittals not having a "G" designation are for information only. When used, a designation following the "G" designation identifies the office that

Detail Drawings; G

SECTION 10 14 02 Page 2

Drawings showing elevations of each type of sign, dimensions, details and methods of mounting or anchoring, shape and thickness of materials, and details of construction. A schedule showing the location, each sign type, and message shall be included.

Installation; G

Manufacturer's descriptive data, catalogs cuts, installation and cleaning instructions.

Interior Signage; G

One sample of each of the following sign types showing typical quality, workmanship and color. The samples may be installed in the work, provided each sample is identified and location recorded.

a. Directional sign.

b. Standard Room sign.

c. Changeable message strip sign.

Approved Manufacturer's Instructions; G Protection and Cleaning; G

Six copies of operating instructions outlining the step-by-step procedures required for system operation shall be provided. The instructions shall include simplified diagrams for the system as installed. Six copies of maintenance instructions listing routine procedures, repairs, and guides shall be provided. The instructions shall include the manufacturer's name, model number, service manual, parts list, and brief description of all equipment and their basic operating features. Each set shall be permanently bound and shall have a hard cover. The following identification shall be inscribed on the covers: the words "OPERATING AND MAINTENANCE INSTRUCTIONS", name and location of the facility, name of the contractor, and contract number.

1.3 GENERAL

Interior signage shall be of the design, detail, sizes, types, and message content shown on the drawings/attachments/signage placement schedule (as applicable), shall conform to the requirements specified, and shall be provided at the locations indicated. Signs shall be complete with lettering, framing as detailed, and related components for a complete installation. Signage shall be obtained from a single manufacturer with edges and corners of finished letterforms and graphics true and clean.

Submit manufacturer documentation indicating the type of recovered materials and the percentage of such material that is (1) recovered and (2) post-consumer recycled content. Alternately, submit written justification of non-use per Section 01 62 35 RECYCLED/RECOVERED MATERIALS

SECTION 10 14 02 Page 3

1.4 QUALIFICATIONS

Signs, plaques, and dimensional letters shall be the standard product of a manufacturer regularly engaged in the manufacture of such products and shall essentially duplicate signs that have been in satisfactory use at least 2 years prior to bid opening.

1.5 DELIVERY AND STORAGE

Materials shall be packaged to prevent damage and deterioration during shipment, handling, storage and installation. Product shall be delivered to the jobsite in manufacturer's original packaging and stored in a clean, dry area in accordance with manufacturer's instructions.

2.1 ROOM IDENTIFICATION/DIRECTIONAL SIGNAGE SYSTEM

2.1.1 Standard Room Signs

Signs shall consist of acrylic plastic 0.080 inch thickness minimum conforming to ANSI Z97.1 or laminated thermosetting Type MP plastic (three-ply melamine plastic laminate with phenolic core) and shall conform to the following:

Units shall be frameless. Corners of signs shall be as shown.

2.1.2 Changeable Message Strip Signs

Changeable message strip signs shall be of same construction as standard room signs to include a clear sleeve that will accept a paper or plastic insert identifying changeable text. The insert shall be prepared typewritten message photographically enlarged or used at actual size.

Sliding inserts or slide knobs that slide horizontally exposing different graphic information shall be provided as identified in the signage placement schedule and drawings

2.1.3 Type of Mounting For Signs

Extruded aluminum brackets shall be furnished for hanging, projecting, and double-sided signs. Surface mounted signs shall be mounted as shown.

2.1.4 Graphics

Signage graphics for modular signs shall conform to the Delivery Order.

2.1.5 Raised and Braille Characters and Pictorial Symbol Signs (Pictograms)

Raised and Braille characters and symbols are only required on signs that designate permanent rooms or spaces, including restrooms and room numbers.

They are not required for information or way-finding signs. Raised letters and numbers on signs must protrude 1/32 inch upper case, sans serif or simple serif type and shall be accompanied with Grade 2 Braille. Raised characters shall be at least 5/8 inch in height, but no higher than 2 inches. Pictograms shall be accompanied by the equivalent verbal description placed directly below the pictogram. The border dimension of

SECTION 10 14 02 Page 4 the pictogram shall be 6 inches minimum in height. Indicated accessible facilities shall use the international symbol of accessibility.

2.2 BUILDING DIRECTORIES

Building directories shall be lobby directories or floor directories, and shall be provided with a changeable directory listing consisting of the areas, offices and personnel located within the facility. Dimensions, details, and materials of sign and message content shall be as shown on the drawings.

2.2.1 Header Panel

Header panel shall be acrylic with raised acrylic letters.

2.2.2 Doors

2.2.2.1 Door Glazing

Door glazing shall be in accordance with ASTM C 1036, Type 1, Class 1, Quality 3, minimum 1/8 inch thick.

2.2.2.2 Door Construction

Extruded aluminum door frame shall be of same finish as surrounding frame.

Corners shall be mitered, and assembled with concealed fasteners. Hinges shall be standard with the manufacturer, in finish to match frames and trim.

Glazing shall be set in frame with resilient glazing channels.

2.2.2.3 Door Locks

Door locks shall be manufacturer's standard, and shall be keyed alike.

2.2.3 Fabrication

Extruded aluminum frames and trim shall be assembled with corners and mitered to a hairline fit, with no exposed fasteners.

2.2.4 Illuminated Units

Illuminated directory units shall have concealed internal lighting with rapid start fluorescent tube lamp, internal wiring, and lead at wire for connection. Electrical work shall comply with NFPA 70 and shall be UL or FM listed.

2.2.5 Changeable Letter/Message Strip Directory System

Directory shall consist of unit with felt grooved for changeable letters.

Design of unit shall be as shown in the drawings.

2.2.5.1 Construction

The directory shall be constructed of an aluminum 2 inch deep frame with satin black anodized finish. Unit shall be surface mounted. Unit shall have a 3 inch high header with lettering as shown. Unit shall have a 3/8 inch face lift off frame width. Door frame shall be aluminum with satin black.

SECTION 10 14 02 Page 5

2.2.5.2 Message Strips

Name strips shall be updatable by user with coupon book reordering and with 5 to 7 day delivery. Name strips shall be sized per manufacturer's standard.

2.3 PRESSURE SENSITIVE LETTERS

Ensure that edges and corners of finished letterforms and graphics are true and clean. Do not use letterforms and graphics with rounded positive or negative corners, nicked, cut, or ragged edges.

2.3.1 Typeface

Helvetica medium.

2.3.2 Size

As indicated.

2.4 ALUMINUM ALLOY PRODUCTS

Aluminum extrusions shall be at least 1/8 inch thick, and aluminum plate or sheet shall be at least 0.0508 inch thick. Extrusions shall conform to ASTM B 221; plate and sheet shall conform to ASTM B 209. Where anodic coatings are specified, alloy shall conform to AA PK-1 alloy designation 514.0.

Exposed anodized aluminum finishes shall be as shown. Welding for aluminum products shall conform to AWS D1.2/D1.2M.

2.5 ANODIC COATING

Anodized finish shall conform to AA DAF-45 as follows:

Clear (natural) designation AA-M10-C22-A31, Architectural Class II 0.4 mil or thicker.

Integral color anodized designation AA-M10-C22-A32, Architectural Class

0.4 to 0.7 mil.

Electrolytically deposited color-anodized designation AA-M10-C22-A34, Architectural Class II 0.4 to 0.7 mil.

2.6 ORGANIC COATING

Organic coating shall conform to AAMA 2604, with total dry film thickness not less than 1.2 mils.

2.7 FABRICATION AND MANUFACTURE

2.7.1 Factory Workmanship

Holes for bolts and screws shall be drilled or punched. Drilling and punching shall produce clean, true lines and surfaces. Exposed surfaces of work shall have a smooth finish and exposed riveting shall be flush.

Fastenings shall be concealed where practicable.

SECTION 10 14 02 Page 6

2.7.2 Dissimilar Materials

Where dissimilar metals are in contact, the surfaces will be protected to prevent galvanic or corrosive action.

2.8 COLOR, FINISH, AND CONTRAST

Color shall be in accordance with Section 09 06 90 COLOR SCHEDULE. Finish of all signs shall be eggshell, matte, or other non-glare finish as required in handicapped-accessible buildings.

Signs shall be installed plumb and true and in accordance with approved manufacturer's instructions at locations shown on the detail drawings.

Mounting height shall be 60 inch above the finish floor to the centerline of the sign. Distance from edge of door frame to edge of sign shall be as indicated on drawings. Required blocking shall be installed. Signs shall be installed on the wall adjacent to the latch side of the door. Where there is no wall space to the latch side of the door, including at double leaf doors, signs shall be placed on the nearest adjacent wall. Mounting location for such signage shall be so that a person may approach within 3 inches of signage without encountering protruding objects or standing within the swing of a door. Signs on doors or other surfaces shall not be installed until finishes on such surfaces have been installed. Signs installed on glass surfaces shall be installed with matching blank back-up plates in accordance with manufacturer's instructions.

3.1.1 Anchorage

Anchorage shall be in accordance with approved manufacturer's instructions.

Anchorage not otherwise specified or shown shall include slotted inserts, expansion shields, and powder-driven fasteners when approved for concrete;

toggle bolts and through bolts for masonry; machine carriage bolts for steel; lag bolts and screws for wood. Exposed anchor and fastener materials shall be compatible with metal where applied and shall have matching color and finish. Where recommended by signage manufacturer, foam tape pads may be used for anchorage. Foam tape pads shall be minimum 1/16 inch thick closed cell vinyl foam with adhesive backing. Adhesive shall be transparent, long aging, high tech formulation on two sides of the vinyl foam. Adhesive surfaces shall be protected with a 5 mil green flatstock treated with silicone. Foam pads shall be sized for the signage as per signage manufacturer's recommendations. Signs mounted to painted gypsum board surfaces shall be removable for painting maintenance. Signs mounted to lay-in ceiling grids shall be mounted with clip connections to ceiling tees.

3.1.2 Protection and Cleaning

The work shall be protected against damage during construction. Hardware and electrical equipment shall be adjusted for proper operation.

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .