- Fence - Gate Installation - Humboldt
- Solicitation number
- Event 34101-13524
- Issued by
- Gibson County, Tennessee
About this file
This appears to be a project scope and diagram document from the Tennessee Department of Military for a fence and gate installation project in Humboldt, Gibson County, Tennessee. Without access to the actual contents of the PDF file, the only confirmed information is that this project involves the installation of a fence and gate with an estimated value under $334,000.00.
Due to the missing content of the file, additional details about pricing terms, specifications, installation requirements, diagrams, timelines, or other technical requirements cannot be accurately summarized.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Event 34101-13524 Page 1 of 2
Sourcing Event 34101-13524 State of Tennessee Military Department
3041 Sidco Drive Nashville, TN 37204
The State of Tennessee, Military Department Sourcing Event 34101-13524 is requesting your company to bid on installing a new fence and gates for this location, per the below scope of work and the attached.
Project Manager: Anthony McCalester Telephone Number: 615-767-0167 E-Mail Address: Anthony.mccalester@tn.gov
Facility: Army National Humboldt 15 Hadley Drive, Humboldt, TN 38343
Mandatory Site Visit – All bidders must attend site visit and sign in to provide a bid response.
The Contractor shall provide all labor, materials and equipment to complete job as specified below. Bid Price shall include all materials, equipment, and labor. Contractor will provide at time of bid with specs of brands that is consider superior or equal for approval.
Ornamental Security Fence Approved Model – Ameristar Impasse II – Gauntlet Style or approved equal, a spec sheet(s) shall be provided at time of bid submission.
- Install approximately 742 LF of 7’ tall security.
- Three-rail design
- 2.75” wide Pales
- 11 ga rails
- 12 ga I beam posts.
- Line post to be on 8’ centers, all posts set in concrete, minimum embed 36.”
- Black “Perma-Coat” finish with 15-year warranty
Ornamental Security Gate - Approved Model – Ameristar Passport IS – Gauntlet Style, Transport Traverse 11, or approved equal.
- Install (1) 30 LF cantilever 7’ tall security gate.
- Three-rail design
- Black “Perma-Coat” finish with 15-year warranty
Mower/Egress Gate chain link – PVC-coated Black Finish
- (1) 10’ Single swing gate on hinges that can be locked with pad lock
- Gate to match PVC-coated Black finish chain link fencing.
Chain Link Fence – PVC-coated Black Finish
- Install approximately 484 LF of 6’ tall with PVC-coated Black finish chain link fence.
- with (3) strands of barbed wire black in color, 12.5-gauge, 4-point barbs, max 5” o.c.
- 9-gauge fabric with 2” chain link mesh- PVC-coated Black finish.
- 3" WT/LG40 corner, end and pull posts. PVC-coated Black finish.
- 2" WT/LG40 weight line posts, PVC-coated Black finish.
- 1-5/8" diameter, 20-weight, top rail, PVC-coated Black finish.
- 7-gauge bottom tension wire, PVC-coated Black finish.
- Line post to be on 10’ centers, all posts set in concrete.
- Tie in new fencing to existing chain link fence post using all new mechanical ties and new barbed wire as needed.
Event 34101-13524 Page 2 of 2
- Selvages: Top and Bottom selvage twisted.
- Remove 90 feet of existing dilapidated fencing and posts and replace with new above stated listing, this has been added to total length. Adjust labor costs accordingly.
Access Controls – Furnish and install.
- Shall be compatible with existing AIPHONE system and tie in.
- (1) dual height gooseneck-stand with two access control pads with cameras
- Minimum 18” diameter concrete pad, embedded 24” in the ground, for gooseneck stand.
- Install a (120v or 240v) single phase circuit, from the nearest service panel in the facility to the gate operator with 1” fiberglass/HDPE or PVC conduit with pull string.
- Install 1” fiberglass/HDPE or PVC conduit for data communication from existing AIPHONE system to the access control pad/camera and operator with pull string.
- Fully integrate the existing system with new components; test & verify proper operation of controls.
- Install (2) protective 6” steel pipe bollards, concrete filled, painted safety yellow, embedded 3’ in the ground in minimum 12’diameter hole with concrete. Shall extend 48” above grade and be plumb in all directions.
- Conduits shall be bored under any concrete or asphalt surfaces.
Heavy Duty Gate Operators – Furnish and install.
Approved Model – Hy Security Slide Driver 15 for gates less than 1500lb or approved equal, a spec sheet(s) shall be provide at time of bid submission.
- 18” minimum concrete pad thickness, minimum 8” embedded in the ground
- All conduits set in concrete pad and concealed by the operator to prevent tampering.
- Install a (120v or 240v) single phase circuit, from the nearest service panel in the facility to the gate operator with 1” fiberglass/HDPE or PVC conduit with pull string.
- Install 1” fiberglass/HDPE or PVC conduit for data communication from existing AIPHONE system to the access control pad/camera and operator with pull string.
- (1) free egress detector loop, cut in existing asphalt pavement
- (1) reversing detector loop, cut in existing asphalt pavement
- Accessories to be installed.
o Internal solenoid lock kit o Fire & Emergency Access Lock Box (with manual release) and Click2enter.
Alternatives to Ameristar Impasse II Fence and Gates – If a vendor determines an equivalent to the Ameristar brand fencing can be provided, it shall be the responsibly of the vendor to provide documentation pointing out the comparison, any options and include notes and specs sheets, easily showing the product is superior to Ameristar Impasse II.
Contractor to verify all measurement and any underground utilities before digging on site.
11/4/24, 11:29 AM Google Earth https://earth.google.com/web/@35.82131063,-88.93677921,106.8459457a,334.45915578d,35y,0h,0t,0r/data=CgRCAggBOgMKATBCAggASg0I____________ARAA 1/1
76'
408'
338'
149'
98'
157'
Power Panel 330' from Gate OP
Data location 240' from Gate OP
Key Pad Location
10' Swing Gate for mower and egress
30' Gate Aprox 742' decorative fence Aprox 484' Black Chain Link 1 ea. 10 swing gate 1 ea. 30 Cant. Gate da02m33 Line da02m33 Line da02m33 Line da02m33 Line da02m33 Line da02m33 Line da02m33 Line da02m33 Line da02m33 Oval da02m33 Oval da02m33 Line da02m33 Line da02m33 Line da02m33 Line da02m33 Line da02m33 Oval da02m33 Line
Hy Security SlideDriver 15
| Humboldt drawings.pdf |
| dayton map 11-6 |
| Spec sheets |