About this file
This document is a Notice to Contractors for a Texas Department of Transportation (TxDOT) project to construct 30'x60' fabric salt sheds at two maintenance facility locations in the Paris District, specifically in Greenville, Texas and Mt. Vernon, Texas. The project, identified as RFC 011859-24-02 and 011859-24-03, has an estimated cost of $260,000 and requires a $5,000 bid guaranty/bid bond. A mandatory pre-bid meeting is scheduled for April 2, 2024 at 9:00 AM CT at the Greenville site, followed by site visits at 10:30 AM and 1:00 PM CT the same day. Requests for information are due by April 8, 2024, and bids are due by May 8, 2024 at 1:00 PM CT to the TxDOT state headquarters in Austin.
The project involves the construction of two fabric salt storage sheds, each 30'x60' in size, with concrete slabs and 8-foot walls. Bidders must bid on all items as specified in the plans and specifications. The contract will not be awarded to any contractor, firm, or subcontractor currently debarred from bidding on TxDOT projects. TxDOT reserves the right to reject any and all proposals. If the project estimate and/or contractor's estimate is $100,000 or greater, the use of Historically Underutilized Businesses (HUBs) is mandated, and a HUB Subcontracting Plan must be submitted with the proposal.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
GENERAL NOTES
1. WORK SHALL CONFORM TO THE CONSTRUCTION DOCUMENTS &
APPLICABLE BUILDING CODES (INCLUDING FEDERAL & STATE CODES,
ORDINANCES, REGULATIONS, ETC.) CONSTRUCTION DOCUMENTS
INCLUDE DRAWINGS & SPECIFICATIONS PLUS ANY ADDENDA TO THE
AFOREMENTIONED.
2. CONSTRUCTION DOCUMENTS ARE INTENDED TO INCLUDE ITEMS
NECESSARY TO CONVEY DESIGN INTENT OF THE WORK.
MANUFACTURERS' INSTRUCTIONS SHALL BE CONSIDERED AS PART OF
THE SPECIFICATIONS WHETHER INCLUDED OR NOT IN THE
SPECIFICATION MANUAL.
3. PERIODIC SITE VISITS BY OWNER'S REPRESENTATIVE SHALL NOT BE
CONSTRUED AS SUPERVISION OF MEANS, METHODS, TECHNIQUES,
SEQUENCES OR PROCEDURES FOR CONSTRUCTION, NOR IMPLY
RESPONSIBILITY FOR PROVIDING A SAFE PLACE FOR PERFORMANCE
OF WORK BY CONTRACTOR OR CONTRACTOR'S EMPLOYEES, OR
EMPLOYEES OF SUPPLIERS, OR FOR ACCESS, VISITS, USE, WORK,
TRAVEL, OR OCCUPANCY BY ANY PERSON.
4. CONTRACTOR IS RESPONSIBLE FOR CONTINUOUS SECURITY AT
AFFECTED OPENINGS FOR THE DURATION OF THE CONSTRUCTION
CONTRACT. COORDINATE SECURITY STATUS CHANGES W/ DISTRICT
REPRESENTATIVE PRIOR TO IMPLEMENTING CHANGES.
5. CONTRACTOR SHALL:
- VERIFY DIMENSIONS & FIELD CONDITIONS BEFORE PROCEEDING.
- NOTIFY TxDOT OF FIELD CONDITIONS REQUIRING DEVIATIONS
FROM CONSTRUCTION DOCUMENTS BEFORE THE CONSTRUCTION
OF ANY MODIFICATION.
- PROVIDE ADEQUATE BRACING & SHORING AS NECESSARY UNTIL
PERMANENT SUPPORTS & STIFFENERS ARE INSTALLED.
- IMMEDIATELY REPAIR OR REPLACE DAMAGED OR DEFECTIVE
WORK TO THE APPROVAL OF (AND AT NO ADDITIONAL COST TO)
THE OWNER
- NOTIFY OWNER AND/ OR TESTING AGENCY & APPROPRIATE
INSPECTORS AT CRITICAL CONSTRUCTION MILESTONES IN ORDER
TO OBTAIN NECESSARY APPROVALS & INSPECTIONS PRIOR TO
COMMENCEMENT OF SUBSEQUENT WORK.
- TAKE REASONABLE PRECAUTIONS FOR THE SAFETY OF, AND
PROVIDE REASONABLE PROTECTION TO PREVENT DAMAGE,
INJURY OR LOSS TO:
a) EMPLOYEES & ALL OTHER AFFECTED PERSONS
b) ALL WORK, MATERIALS & EQUIPMENT
c) OTHER PROPERTY AT SITE OR ADJACENT THERETO.
- UPON COMPLETION OF THE WORK, REMOVE MATERIALS, TOOLS &
EQUIPMENT AND LEAVE SITE IN A CONDITION ACCEPTABLE TO
OWNER.
Support Services Division / Facilities Planning & Management
COPYRIGHT 2020 TEXAS DEPTARTMENT OF TRANSPORTATION
6230 E. Stassney Ln.
Austin, TX 78744-3147
(512) 416-2257 c
VICINITY MAP
INDEX OF DRAWINGS
PROJECT:
Project Manager:
STRUCTURE:
G E
N E
R A
T E
D O
N
/1
/2
:4 :0
P
M U
T x D
O T
T
E M
P P
R O
J E
C T
S \C
P M
D A
P H
N E
H A
R R
IS
\0
P
A R
G re e n v ill e S a lt S h e d \G re e n v ill e
'x
' M u lti S it e
F A
B R
IC
S
A L T
S H
E D
.r v t
P A
R
IS
D
IS
T R
IC
T
M U
L T
I- S
IT
E
'x
' F A
B R
IC
S
A L
T S
H E
D S
DAPHNE HARRIS
(512) 765-3527 Daphne.Harris@TxDOT.GOV
PARIS DISTRICT MULTI-SITE
30'x60' FABRIC SALT SHEDS
A. M. Stone, P.E.
Phone: (512) 902-9922 E-mail: Amy.Stone@TxDOT.gov
Facilities Planning & Management Support Services Division, TxDOT 6230 E. Stassney Ln.
Austin, TX 78744
STRUCTURAL
S1.01 STRUCTURAL NOTES AND ESTIMATES QUANTITIES (GREENVILLE)
S1.02 STRUCTURAL NOTES AND ESTIMATES QUANTITIES (MT VERNON)
S2.01 FOUNDATION DETAILS
GENERAL SHEETS
G0.0 COVER SHEET
ARCHITECTURAL
A1.02 GREENVILLE MAINTENANCE FACILITY
A1.03 MT VERNON MAINTENANCE FACILITY
A2.01 PLANS AND ELEVATIONS
SHED: 1800 SQ. FT.
CONCRETE APRON: 300 SQ. FT.
TOTAL SQ. FT.: 2,100 SQ. FT.
SCOPE OF WORK:
WORK OF THE PROJECT INCLUDES THECONSTRUCTION OF A FABRIC STRUCTURE ROOF OVER A CAST IN PLACE CONCRETE FLOOR AND 8 ft. WALLS
AND FABRIC END WALL.
CONTRACTOR SHALL COORDINATE WITH OWNER FOR EXACT LOCATIONS OF BUILDINGS ON SITE.
BUILDING SUMMARY : BUILDING CODES :
INTERNATIONAL BUILDING CODE IBC - 2021 EDITION
WICHITA
FALLS
BEAUMONT
PARIS
ATLANTA
BRYAN
BROWNWOOD
AMARILLO
ABILENE
CHILDRESS
FORT
WORTH
CORPUS
CHRISTI
DALLAS
EL PASO
HOUSTON
LAREDO
LUBBOCK
LUFKIN
ODESSA
SAN
ANGELO
SAN
ANTONIO
YOAKUM
WACO
TYLER
PHARR
HUNT COUNTY, TXFRAKLIN COUNTY, TX
GREENVILLE MAINTENANCE FACILITY
Site #: 019064 Building #: 018189 Address: 3001 I-30 East, Greenville, TX 75402
Franklin County Project ID: 01-1859-24-02
MT VERNON MAINTENANCE FACILITY
Site #: 019021 Building #: 018188 Address: 104 East IH 30, Mt Vernon, TX 75457
Hunt County Project ID: 01-1859-24-03
MULTIPLE COUNTIES
SULPHUR
SPRINGS
GREENVILLE
MT VERNON
03/13/2024
GRADE TO
EXISTING GRADING
LIMITS OF
EXCAVATION
LIMITS OF CONSTRUCTION
COORDINATE WITH
OWNER'S REP.
B U
IL
D
IN
G
APRON
NOTES:
1. PROPOSED LOCATION. OF SALT STORAGE SHED IS APPROXIMATE.
2. CONTRACTOR TO COORDINATE DESIRED FINAL LOCATION WITH OWNER.
3. CONTRACTOR SHALL LOCATE UNDERGROUND UTILITIES BEFORE FINALIZING
LOCATON OF SALT STORAGE SHED.
4. EXISTING GRADE ELEVATION IS PRESUMED TO BE 7" BELOW FINISH FLOOR
ELEVATION AT BACK WALL WHICH IS REFERENCED AS 0'-0".
5. FINISH GRADE AT OUTSIDE EDGE OF BUILDING SLAB SHALL BE BELOW
FINISHED FLOOR ELEVATION.
6. GRADE AWAY FROM BUILDING TO MEET EXISTING GRADE TO A DISTANCE OF
4'-0" FROM FACE OF CONCRETE WALL AND EDGE OF CONCRETE APRON.
THIS DRAWING CREATED FOR PRODUCTION ON 22"x34" SHEET SIZE. DO NOT SCALE PRINTS.
G E
N E
R A
T E
D O
N
REVISIONS:
COPYRIGHT 2024c
Texas of Transportation Department
R
# DATE INITIALS
/1
/2
:4 :5
P
M U
T x D
O T
T
E M
P P
R O
J E
C T
S \C
P M
D A
P H
N E
H A
R R
IS
\0
P
A R
G re e n v ill e S a lt S h e d \G re e n v ill e
'x
' M u lti S it e
F A
B R
IC
S
A L T
S H
E D
.r v t
A1.02
CHECKED BY: RG
DATE ISSUED: 3/14/2024
DRAWN BY: JR
P A
R
IS
D
IS
T R
IC
T
M U
L T
I- S
IT
E
'x
' F
A B
R
IC
S A
L T
S H
E D
M u lt ip le L o c a ti o n s
S e e C o v e r
S h e e t
M U
L T
IP
L E
C O
U N
T
IE
S
P A
R
IS
D
IS
T R
IC
T
P R
O J E
C T
N o M u lt ip le I D s
S e e C o v e r
S h e e t
GREENVILLE MAINTENANCE FACILITY
1" = 80'-0"
SITE PLAN - AUSTIN NORTH
TRUE NORTH
3001 I-30 EAST, GREENVILLE, TX 75402
GRADE TO
EXISTING
GRADING
LIMITS OF
EXCAVATION
LIMITS OF
CONSTRUCTION
COORDINATE WITH
OWNER'S REP.
NOTES:
1. PROPOSED LOCATION. OF SALT STORAGE SHED IS APPROXIMATE.
2. CONTRACTOR TO COORDINATE DESIRED FINAL LOCATION WITH OWNER.
3. CONTRACTOR SHALL LOCATE UNDERGROUND UTILITIES BEFORE FINALIZING
LOCATON OF SALT STORAGE SHED.
4. EXISTING GRADE ELEVATION IS PRESUMED TO BE 7" BELOW FINISH FLOOR
ELEVATION AT BACK WALL WHICH IS REFERENCED AS 0'-0".
5. FINISH GRADE AT OUTSIDE EDGE OF BUILDING SLAB SHALL BE BELOW
FINISHED FLOOR ELEVATION.
6. GRADE AWAY FROM BUILDING TO MEET EXISTING GRADE TO A DISTANCE OF
4'-0" FROM FACE OF CONCRETE WALL AND EDGE OF CONCRETE APRON.
BUILDING
A P
R O
N
THIS DRAWING CREATED FOR PRODUCTION ON 22"x34" SHEET SIZE. DO NOT SCALE PRINTS.
G E
N E
R A
T E
D O
N
REVISIONS:
COPYRIGHT 2024c
Texas of Transportation Department
R
# DATE INITIALS
/1
/2
:4 :5
P
M U
T x D
O T
T
E M
P P
R O
J E
C T
S \C
P M
D A
P H
N E
H A
R R
IS
\0
P
A R
G re e n v ill e S a lt S h e d \G re e n v ill e
'x
' M u lti S it e
F A
B R
IC
S
A L T
S H
E D
.r v t
A1.03
CHECKED BY: RG
DATE ISSUED: 3/14/2024
DRAWN BY: JR
P A
R
IS
D
IS
T R
IC
T
M U
L T
I- S
IT
E
'x
' F
A B
R
IC
S A
L T
S H
E D
M u lt ip le L o c a ti o n s
S e e C o v e r
S h e e t
M U
L T
IP
L E
C O
U N
T
IE
S
P A
R
IS
D
IS
T R
IC
T
P R
O J E
C T
N o M u lt ip le I D s
S e e C o v e r
S h e e t
MT VERNON MAINTENANCE FACILITY
1" = 80'-0"
SITE PLAN - MT VERNON
TRUE NORTH
104 EAST IH 30, MOUNT VERNON, TX 75457
CONCRETE APRON
30' - 0"
30' - 0"
⌀6" BOLLARD
SEE DETAIL
S L O
P E
/8
0' - 0" 0' - 0"
BUILDING
-0' - 2"
0' - 0" 0' - 0"
-0'- 5"
TYP.
2' - 0"
-0'-3¾"-0'-3¾"
STRUCTURAL
CONCRETE SLAB
A2.013
A2.01
A2.01
A2.01
ARCHED FABRIC
ROOF SRUCTURE
SLOPE SLOPE
SLOPE SLOPE
TOP OF CONC.
8' - 0"
STEEL BOLLARD
REFER TO 4/S1.1
ARCHED FABRIC
STRUCTURE
AS SPECIFIED
INT. CLEARANCE
18' - 0"
APRON EDGE
-0' - 5"
TOP OF CONC.
8' - 0"
ARCHED FABRIC
STRUCTURE AS
SPECIFIED
SLOPE GRADE AWAY FROM BUILDING
USING SELECT FILL OR EXISTING
MATERIAL WHEN ALLOWABLE
STEEL BOLLARD REFER TO 4/S2.1
INT. CLEARANCE
18' - 0"
APRON EDGE
-0' - 5"
F.F.ELEV
0' - 0"
TOP OF LOUVER
16' - 0"
TOP OF CONC.
8' - 0"
36" x 36" FIXED LOUVER
AS SPECIFIED.
F.F.ELEV
0' - 0"
TOP OF CONC.
8' - 0"
INT. CLEARANCE
18' - 0"
STEEL BOLLARD
REFER TO 4/S1.1
ARCHED FABRIC
STRUCTURE
AS SPECIFIED
APRON EDGE
-0' - 5"
THIS DRAWING CREATED FOR PRODUCTION ON 22"x34" SHEET SIZE. DO NOT SCALE PRINTS.
G E
N E
R A
T E
D O
N
REVISIONS:
COPYRIGHT 2024c
Texas of Transportation Department
R
# DATE INITIALS
/1
/2
:4 :0
P
M U
T x D
O T
T
E M
P P
R O
J E
C T
S \C
P M
D A
P H
N E
H A
R R
IS
\0
P
A R
G re e n v ill e S a lt S h e d \G re e n v ill e
'x
' M u lti S it e
F A
B R
IC
S
A L T
S H
E D
.r v t
A2.01
CHECKED BY: AMS
DATE ISSUED: 3/14/2024
DRAWN BY: JR
P A
R
IS
D
IS
T R
IC
T
M U
L T
I- S
IT
E
'x
' F
A B
R
IC
S A
L T
S H
E D
M u lt ip le L o c a ti o n s
S e e C o v e r
S h e e t
M U
L T
IP
L E
C O
U N
T
IE
S
P A
R
IS
D
IS
T R
IC
T
P R
O J E
C T
N o M u lt ip le I D s
S e e C o v e r
S h e e t
PLANS AND ELEVATIONS
1/8" = 1'-0"
FLOOR PLAN
1/8" = 1'-0"
ROOF PLAN
1/8" = 1'-0"
FRONT
1/8" = 1'-0"
LEFT SIDE
1/8" = 1'-0"
REAR
1/8" = 1'-0"
RIGHT SIDE
CODES
1. Building Code: International Building Code 2021
2. Structural Concrete: Building Code Requirements for Reinforced Concrete, American Concrete Institute, ACI 318-19.
3. This construction is of a minor nature and does not require Special Inspections.
4. Apply two heavy coats of linseed oil to all exposed concrete surfaces.
DESIGN LOADS
1. Live Loads
a. Storage (minimum) 125 psf
b. Roof 20 psf
2. Snow Load
a. Ground Snow Load, Pg 5 psf ASCE 7-16
3. Wind Lateral Load on Structural Frame shall be based on the following:
a. Base Wind Speed 105 mph ASCE 7-16
b. Exposure C
c. Importance Factor 1.0
d. Internal Pressure Coefficient 0.55 (Partially enclosed)
4. Dead Loads include the self weight of the structural elements.
5. Foundation design based on publically available data. Design PI= 31
6. This construction is of a minor nature and does not require Special Inspections.
7. Seismic Design Parameter
RISK CATEGORY 2
SEISMIC IMPORTANCE FACTOR 1
SITE CLASS D
MAPPED SPECTRAL RESPONSE ACCELERATION: SS 0.116 AND
S1 0.062
SEISMIC DESIGN CATEGORY B
BASIC SEISMIC FORCE RESISTING SYSTEM ORDINARY PLAIN
CONCRETE SHEAR WALLS
DESIGN BASE SHEAR W*0.01 (SECTION 1.4, ASCE7)
SEISMIC RESPONSE COEFF, CS 0.01 (MINIMUM)
RESPONSE MODIFICATION FACTOR, R 1.5
ANALYSIS PROCEDURE USED, ELF
8 Rain Load
15 MIN INTENSITY= 7.78 IN/HR, 60 MIN INTENSITY= 3.58 IN/HR
BUILDING PAD PREPARATION
1. Site erosion and sediment control shall be the responsibility of the contractor. Contractor shall create an erosion and sediment control plan and submit to Owner for approval prior to beginning work.
a. All material to meet Filtrexx specifications.
b. Siltsoxx compost/soil/rock/seed fill to meet application requirements.
c. Siltsoxx is for minimum slopes. Greater slopes may require larger rock
d. Compost material to be dispersed on site, as determined by Owner.
2. Any import or select fill shall be an approved inorganic material, free of debris. Select fill material should have a maximum Plasticity Index (PI) of 17 and have a maximum particle size of three (3) inches.
3. Contractor shall locate and identify any underground utilities or obstructions in the vicinity of the building pad.
4. Existing asphalt and any soft/loose materials shall be stripped and removed from the proposed building footprint to allow for a uniform and level surface.
5. Following stripping operations, the floor slab area shall be excavated, as necessary, an additional 12 inches minimum below the building foundation.
The excavation areas shall extend a minimum of three (3) feet beyond the horizontal limits of the proposed building footprints.
6. Following excavation, the exposed subgrade areas shall be proof-rolled to expose any weak, soft, wet, or otherwise unsuitable soils that should be removed.
7. Following proof-rolling, the exposed subgrade soils shall be scarified to a depth of six (6) inches, moisture conditioned between -3 and +3 percentage points above optimum moisture content andcompacted to at least 95 percent of the maximum dry density as determined in accordance with Tex-114-E.
8. Following approval of the subgrade, the select fill shall be placed up to the desired final building pad elevation. In no case shall the select fill material be less than 12 inches thick. The select fill shall be placed in eight (8) inch maximum thick loose lifts. The select fill shall be moisture conditioned between -3 and +3 percentage points of optimum moisture content and compacted to a minimum of 95 percent of the maximum dry density as determined in accordance with Tex-113-E for gravelly select fill and Tex-114-E for select fill without gravel.
9. Provide a 10 mil polyolefin vapor retarder. Place vapor retarder in accordance with manufacturer's recommendation on top of select fill.
CAST IN PLACE CONCRETE
28 Day Strength Aggregate Size Slump Air W/C
3000 PSI 1"MAX 3"-5" 4.5% +/-1.5% 0.40 (MAX)
1. Alternate Concrete mixture shall meet the requirements of ACI 318 Table 19.3.2.1 "Requirements for concrete by exposure class" for exposure class C2 & F2 concrete.
2. Erection of the structure may not begin until concrete foundation has cured for a minimum of 7 days. heavy loads shall not be stockpiled on the slab until it has cured for a minimum of three days.
3. Holes left from wall forms shall be filled with a non shrink grout or approved material.
FOUNDATION
1. If bearing soils are softened by surface water intrusions during exposure or by desiccation, the unsuitable material shall be removed from the foundation excavation prior to placement of concrete.
2. Minimum allowable soil bearing pressure shall be 1500 psf. To be verified by the contractors geotechnical engineer.
CONCRETE REINFORCING
1. Reinforcing steel shall be in accordance with ASTM A615, Grade 60.
2. Detailing of reinforcing steel shall conform to the American Concrete Institute Detailing Manual.
3. All hooks and bends in reinforcing bars shall conform to ACI detailing standards unless noted otherwise.
4. In unscheduled beams and slabs, detail reinforcing as follows:
a. Lap top reinforcing bars at mid span.
b. Lap bottom reinforcing bars at the supports.
c. Lap reinforcement bars the standard lap length unless noted otherwise.
d. Provide standard hooks in top bars at cantilever and discontinuous ends of beams, walls and slabs.
e. Provide corner bars for all horizontal bars at the inside and outside faces of intersecting beams or walls. Corner bars are not required if horizontal bars are hooked.
5. Steel reinforcement shall not be stabbed into place
6. Welding of reinforcing steel will not be permitted.
6. Heat shall not be used in the fabrication or installation of reinforcement.
8. Reinforcing steel clear cover shall be as follows:
a. Grade beams and Slab 3" top, 3" bottom, 2" side (formed), 3" side (placed against earth)
b. Wall 2" top, 2" exterior side(formed), 3" interior side
CONCRETE FINISHES
1. Slab Finishes:
a. Apron Slab - Medium broom finish (parallel to the longer dimension of the apron)
b. Slab floor - Normal steel trowel finish per ACI 302.1 for class 5 floors
2. Wall Finish - Smooth finish
3. Smooth form facing materials only on exposed concrete walls.
THIS DRAWING CREATED FOR PRODUCTION ON 22"x34" SHEET SIZE. DO NOT SCALE PRINTS.
G E
N E
R A
T E
D O
N
REVISIONS:
COPYRIGHT 2024c
Texas of Transportation Department
R
# DATE INITIALS
/1
/2
:4
:0
P
M U
T x D
O T
T
E M
P P
R O
J E
C T
S \ C
P M
D A
P H
N E
H A
R R
IS
\ 0
P
A R
G re e n v ill e S a lt
S h e d \G re e n v ill e
'x
' M u lt iS it e F
A B
R
IC
S A
L T
S H
E D
.r v t
S1.01
CHECKED BY: AMS
DATE ISSUED: 3/14/2024
DRAWN BY: JR
P A
R
IS
D
IS
T R
IC
T
M U
L T
I- S
IT
E
'x
' F
A B
R
IC
S A
L T
S H
E D
M u lt ip le L o c a ti o n s
S e e C o v e r
S h e e t
M U
L T
IP
L E
C O
U N
T
IE
S
P A
R
IS
D
IS
T R
IC
T
P R
O J E
C T
N o M u lt ip le I D s
S e e C o v e r
S h e e t
STRUCTURAL NOTES AND ESTIMATES QUANTITIES (GREENVILLE)
STRUCTURAL NOTES
1/4" = 1'-0"
STRUCTURAL NOTES (GREENVILLE)
CODES
1. Building Code: International Building Code 2021
2. Structural Concrete: Building Code Requirements for Reinforced Concrete, American Concrete Institute, ACI 318-19.
3. This construction is of a minor nature and does not require Special Inspections.
4. Apply two heavy coats of linseed oil to all exposed concrete surfaces.
DESIGN LOADS
1. Live Loads
a. Storage (minimum) 125 psf
b. Roof 20 psf
2. Snow Load
a. Ground Snow Load, Pg 5 psf ASCE 7-16
3. Wind Lateral Load on Structural Frame shall be based on the following:
a. Base Wind Speed 105 mph ASCE 7-16
b. Exposure C
c. Importance Factor 1.0
d. Internal Pressure Coefficient 0.55 (Partially enclosed)
4. Dead Loads include the self weight of the structural elements.
5. Foundation design based on publically available data. Design PI= 31
6. This construction is of a minor nature and does not require Special Inspections.
7. Seismic Design Parameter
RISK CATEGORY 2
SEISMIC IMPORTANCE FACTOR 1
SITE CLASS D
MAPPED SPECTRAL RESPONSE ACCELERATION: SS 0.111 AND
S1 0.066
SEISMIC DESIGN CATEGORY B
BASIC SEISMIC FORCE RESISTING SYSTEM ORDINARY PLAIN
CONCRETE SHEAR WALLS
DESIGN BASE SHEAR W*0.01 (SECTION 1.4, ASCE7)
SEISMIC RESPONSE COEFF, CS 0.01 (MINIMUM)
RESPONSE MODIFICATION FACTOR, R 1.5
ANALYSIS PROCEDURE USED, ELF
8 Rain Load
15 MIN INTENSITY= 7.8 IN/HR, 60 MIN INTENSITY= 3.5 7 IN/HR
BUILDING PAD PREPARATION
1. Site erosion and sediment control shall be the responsibility of the contractor. Contractor shall create an erosion and sediment control plan and submit to Owner for approval prior to beginning work.
a. All material to meet Filtrexx specifications.
b. Siltsoxx compost/soil/rock/seed fill to meet application requirements.
c. Siltsoxx is for minimum slopes. Greater slopes may require larger rock
d. Compost material to be dispersed on site, as determined by Owner.
2. Any import or select fill shall be an approved inorganic material, free of debris. Select fill material should have a maximum Plasticity Index (PI) of 17 and have a maximum particle size of three (3) inches.
3. Contractor shall locate and identify any underground utilities or obstructions in the vicinity of the building pad.
4. Existing asphalt and any soft/loose materials shall be stripped and removed from the proposed building footprint to allow for a uniform and level surface.
5. Following stripping operations, the floor slab area shall be excavated, as necessary, an additional 12 inches minimum below the building foundation.
The excavation areas shall extend a minimum of three (3) feet beyond the horizontal limits of the proposed building footprints.
6. Following excavation, the exposed subgrade areas shall be proof-rolled to expose any weak, soft, wet, or otherwise unsuitable soils that should be removed.
7. Following proof-rolling, the exposed subgrade soils shall be scarified to a depth of six (6) inches, moisture conditioned between -3 and +3 percentage points above optimum moisture content andcompacted to at least 95 percent of the maximum dry density as determined in accordance with Tex-114-E.
8. Following approval of the subgrade, the select fill shall be placed up to the desired final building pad elevation. In no case shall the select fill material be less than 12 inches thick. The select fill shall be placed in eight (8) inch maximum thick loose lifts. The select fill shall be moisture conditioned between -3 and +3 percentage points of optimum moisture content and compacted to a minimum of 95 percent of the maximum dry density as determined in accordance with Tex-113-E for gravelly select fill and Tex-114-E for select fill without gravel.
9. Provide a 10 mil polyolefin vapor retarder. Place vapor retarder in accordance with manufacturer's recommendation on top of select fill.
CAST IN PLACE CONCRETE
28 Day Strength Aggregate Size Slump Air W/C
3000 PSI 1"MAX 3"-5" 4.5% +/-1.5% 0.40 (MAX)
1. Alternate Concrete mixture shall meet the requirements of ACI 318 Table 19.3.2.1 "Requirements for concrete by exposure class" for exposure class C2 & F2 concrete.
2. Erection of the structure may not begin until concrete foundation has cured for a minimum of 7 days. heavy loads shall not be stockpiled on the slab until it has cured for a minimum of three days.
3. Holes left from wall forms shall be filled with a non shrink grout or approved material.
FOUNDATION
1. If bearing soils are softened by surface water intrusions during exposure or by desiccation, the unsuitable material shall be removed from the foundation excavation prior to placement of concrete.
2. Minimum allowable soil bearing pressure shall be 1500 psf. To be verified by the contractors geotechnical engineer.
CONCRETE REINFORCING
1. Reinforcing steel shall be in accordance with ASTM A615, Grade 60.
2. Detailing of reinforcing steel shall conform to the American Concrete Institute Detailing Manual.
3. All hooks and bends in reinforcing bars shall conform to ACI detailing standards unless noted otherwise.
4. In unscheduled beams and slabs, detail reinforcing as follows:
a. Lap top reinforcing bars at mid span.
b. Lap bottom reinforcing bars at the supports.
c. Lap reinforcement bars the standard lap length unless noted otherwise.
d. Provide standard hooks in top bars at cantilever and discontinuous ends of beams, walls and slabs.
e. Provide corner bars for all horizontal bars at the inside and outside faces of intersecting beams or walls. Corner bars are not required if horizontal bars are hooked.
5. Steel reinforcement shall not be stabbed into place
6. Welding of reinforcing steel will not be permitted.
6. Heat shall not be used in the fabrication or installation of reinforcement.
8. Reinforcing steel clear cover shall be as follows:
a. Grade beams and Slab 3" top, 3" bottom, 2" side (formed), 3" side (placed against earth)
b. Wall 2" top, 2" exterior side(formed), 3" interior side
CONCRETE FINISHES
1. Slab Finishes:
a. Apron Slab - Medium broom finish (parallel to the longer dimension of the apron)
b. Slab floor - Normal steel trowel finish per ACI 302.1 for class 5 floors
2. Wall Finish - Smooth finish
3. Smooth form facing materials only on exposed concrete walls.
THIS DRAWING CREATED FOR PRODUCTION ON 22"x34" SHEET SIZE. DO NOT SCALE PRINTS.
G E
N E
R A
T E
D O
N
REVISIONS:
COPYRIGHT 2024c
Texas of Transportation Department
R
# DATE INITIALS
/1
/2
:4
:0
P
M U
T x D
O T
T
E M
P P
R O
J E
C T
S \ C
P M
D A
P H
N E
H A
R R
IS
\ 0
P
A R
G re e n v ill e S a lt
S h e d \G re e n v ill e
'x
' M u lt iS it e F
A B
R
IC
S A
L T
S H
E D
.r v t
S1.02
CHECKED BY: AMS
DATE ISSUED: 3/14/2024
DRAWN BY: JR
P A
R
IS
D
IS
T R
IC
T
M U
L T
I- S
IT
E
'x
' F
A B
R
IC
S A
L T
S H
E D
M u lt ip le L o c a ti o n s
S e e C o v e r
S h e e t
M U
L T
IP
L E
C O
U N
T
IE
S
P A
R
IS
D
IS
T R
IC
T
P R
O J E
C T
N o M u lt ip le I D s
S e e C o v e r
S h e e t
STRUCTURAL NOTES AND ESTIMATES QUANTITIES (MT VERNON)
STRUCTURAL NOTES
SLAB REINF.
SEE PLAN (TYP.)
EXTERIOR GRADE OR
RECYCLED ASPHALT. SLOPE
AWAY FROM BLDG. (TYP.)
SEE PLAN
F.F. ELEV =
2 (TWO) #4 CONT. AT 12"
O. C.
3" CL.
#4 AT 12" O. C.
2" CL.
(V A
R
IE
S W
IT
H
S L O
P
IN
G S
L A
B
M
IN
1' - 0"
CLEAN & ROUGHEN
CONCRETE SURFACE
AT CNSTR. JOINT
INTERFACE (TYP.)
#4 AT 12" O. C.
12"
24"
HYDROPHILIC CONT.
WATERSTOP (2" MIN
COVER)
COMPACTED
SELECT FILL SEE
FOUNDATION
NOTES ON S1.1 TYP.
(V A
R
IE
S
/4
M
IN
1' - 6"
3"
VAPOR BARRIER (TYP.)
SEE PLAN
8' - 0"
2 #6 CONT. TOP AND BOT W/#
3 STIRRUPS @ 12" O.C. (TYP.)
POINT OF ATTACHMENT
ROOF STRUCTURE BY
MANUFACTURER
1"
1" CHAMFER (TYP.)
1" CHAMFER (TYP.)
E M
B E
D
SEE A2.1
F.F. ELEV =
GR. BM. REINF. W/ TWO
#6 T&B, #3 STIRRUPS AT
12" O.C
1/8 / FT.SLOPE +/-
SLAB REINFORCEMENT
SEE PLAN
#4 AT 12" O. C.
12"
24"
VAPOR BARRIER (TYP.)
7" THICK CONC. APRON
1/2" JOINT FILLER (FIBER
BOARD OR EQUAL)
#4 AT 12" O. C.
EACH WAY TYP.
1/2" SMOOTH DOWEL X
1'-6" @ 24" O.C. GREASE
OR SHEATH ONE END
1' - 2"1' - 2"
VARIES
(SEE PLAN SHEET
1/A2.1)
F.F. ELEV =
TYP.
3" CL.
T Y
P
C L
S E
E P
L A
N
SLAB REINFORCEMENT
SEE PLAN
1' - 2"
GR. BM. REINF. W/ TWO #6 T&B
#3 STIRRUPS AT 12" O.C1
1' - 2"
3"
#4 AT 12" O. C.
EACH WAY TYP.
CONT. #4 BAR
7" THICK
CONCRETE APRON
1" CHAMFER
CORNER AND INTERSECTION
REINFORCING APPLIES TO
TOP AND BOTTOM AND
INTERMEDIATE BARS.
CORNER BARS SIZE SAME AS
MAIN REINFORCEMENT
12"
T Y
P"
T Y
P"
24"
12"
24"
CONCRETE APRON
BUILDING
SLAB
3" 30' - 0" 3"
30' - 0"
S2.01
S2.01
S2.01
S2.01
S2.01
S2.01
1" CHAMFER
(TYP.)
1" CHAMFER
(TYP.)
DO NOT POUR WALL UNTIL
CONNECTIONS FOR PRE-ENGINEERED
FABRIC SHED ARE INSTALLED
2' - 0"
7" SLAB
COMPACTED SELECT FILL
10 MIL VAPOR BARRIER
GENERAL NOTES
1. REFER TO SITE PLAN FOR BUILDING
LOCATION
2. U. N. O. ALL DIMENSIONS ON THIS SHEET
ARE FROM FACE OF CONCRETE, OR EDGE
OF CONCRETE SLOPE.
3. REFER TO SPECIFICATION SECTION 01 33
00- SUBMITTAL PROCEDURES FOR
ADDITIONAL SUBMITTAL INFORMATION AND
REQUIREMENTS.
4. ALL DETAILS ARE TYPICAL UNLESS NOTED
OTHERWISE. DETAILS SHALL APPLY TO ALL
SIMILAR AND LIKE CONDITIONS.
7" THICK CONCRETE SLAB ON GRADE
W/ #4 @ 12" O. C. EA WAY ON 3" HIGH
CHAIRS @ 42" O. C. EA WAY. PLACE
SLAB ON 10 MIL VAPOR BARRIER OVER
COMPACTED SELECT FILL.
6" SCHEDULE 40 STEEL
PIPE BOLLARD FILLED
WITH CONCRETE.
7" CONCRETE
APRON (FINAL)
CONCRETE FOOTING
(2) 1'-0" LONG #4 REBAR
THROUGH PIPE BOLLARD
(2 LOCATIONS TYP)
1/2" JOINT WITH
COMPRESSIBLE JOINT
SEALER
SEE PLAN
F.F. ELEV =
60" H HD POLYETHELENE
BOLLARD COVER W/ TWO
RED STRIPES AT TOP,
EQUAL TO: GRAINGER,
ITEM # 4GRE6
1' - 6"
THIS DRAWING CREATED FOR PRODUCTION ON 22"x34" SHEET SIZE. DO NOT SCALE PRINTS.
G E
N E
R A
T E
D O
N
REVISIONS:
COPYRIGHT 2024c
Texas of Transportation Department
R
# DATE INITIALS
/1
/2
:4 :0
P
M U
T x D
O T
T
E M
P P
R O
J E
C T
S \C
P M
D A
P H
N E
H A
R R
IS
\0
P
A R
G re e n v ill e S a lt S h e d \G re e n v ill e
'x
' M u lti S it e
F A
B R
IC
S
A L T
S H
E D
.r v t
S2.01
CHECKED BY: AMS
DATE ISSUED: 3/14/2024
DRAWN BY: JR
P A
R
IS
D
IS
T R
IC
T
M U
L T
I- S
IT
E
'x
' F
A B
R
IC
S A
L T
S H
E D
M u lt ip le L o c a ti o n s
S e e C o v e r
S h e e t
M U
L T
IP
L E
C O
U N
T
IE
S
P A
R
IS
D
IS
T R
IC
T
P R
O J E
C T
N o M u lt ip le I D s
S e e C o v e r
S h e e t
FOUNDATION DETAILS
3/4" = 1'-0"
FOOTING AND WALL DETAIL
3/4" = 1'-0"
EXTERIOR GRADE BEAM
3/4" = 1'-0"
INTERIOR GRADE BEAM
3/4" = 1'-0"
CONCRETE APRON DETAIL
3/4" = 1'-0"
TYP. CORNER AND INTERSECTION REINFORCEMENT
1/8" = 1'-0"
FOUNDATION PLAN
3/4" = 1'-0"
SLAB DETAIL
3/4" = 1'-0"
BOLLARD W.SLEEVE @CONC. (TYP.)
| Sheets |
| A1.02 - GREENVILLE MAINTENANCE FACILITY |
| A1.03 - MT VERNON MAINTENANCE FACILITY |
| A2.01 - PLANS AND ELEVATIONS |
| G0.0 - COVER SHEET |
| S1.01 - STRUCTURAL NOTES AND ESTIMATES QUANTITIES (GREENVILLE) |
| S1.02 - STRUCTURAL NOTES AND ESTIMATES QUANTITIES (MT VERNON) |
| S2.01 - FOUNDATION DETAILS |
File details come from the government source that posted it. Updated .