ESBD_File_351190_111851-24-02-plans.pdf

PDF 2 MB Posted

Attached to
RFC 111851-24-02 HVAC Corrections & Controls Upgrade, LFK DHQ Admin.
Solicitation number
111851-24-02
Issued by
Angelina County, Lufkin City, Texas

About this file

This document is a Request for Bid (RFB) issued by the Texas Department of Transportation (TxDOT) Lufkin District for the HVAC Corrections & Controls Upgrade project at the Lufkin District Headquarters (DHQ) Administration Building located at 1805 N. Timberland Dr., Lufkin, TX 75901. The scope of work includes upgrading the Building Automation System (BAS) to a system capable of expansion, replacing sensors and devices, providing new network-level area controllers, field controllers, and low voltage wiring. The project is estimated to cost $250,000. A mandatory pre-bid meeting is scheduled for February 27, 2024, at 11:00 AM CT, and bids are due on April 3, 2024, at 1:00 PM CT. The contract will be awarded to the successful bidder, and no bids will be returned to the bidders.

The bid guaranty/bond requirement is $5,000. Pre-qualification of contractors is waived; however, the use of Historically Underutilized Businesses (HUBs) is mandated if the project estimate and/or contractor's estimate is greater than or equal to $100,000, and a HUB Subcontracting Plan (HSP) must be submitted with the proposal package. The Texas Department of Transportation reserves the right to reject any and all proposals.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

TXDOT - LUFKIN

DISTRICT OFFICE

BUILDING AUTOMATION UPGRADE

I N D E X OF D R A W I N G S 1805 N. TIMBERLAND DR

LUFKIN TEXASC0.01 COVER SHEET

M2.01 MECHANICAL PLAN

M2.02 MECHANICAL PLAN

CODES

2018 INTERNATIONAL MECHANICAL CODE

2020 NATIONAL ELECTRICAL CODE

2015 INTERNATIONAL ENERGY CONSERVATION CODE

2018 INTERNATIONAL FIRE CODE

2018 INTERNATIONAL BUILDING CODE

2018 INTERNATIONAL EXISTING BUILDING CODE

2018 INTERNATIONAL PLUMBING CODE

SCOPE OF WORK

· UPGRADE THE BUILDING AUTOMATION SYSTEM (BAS) TO A SYSTEM CAPABLE OF

EXPANSION, READING ADDITIONAL POINTS FROM THE TERMINAL UNITS AND

REPAIRING / REPLACING SENSORS AND DEVICES THAT ARE NO LONGER OPERATING OR

ARE GIVING FAULTY READINGS (SUCH AS THE TEMPERATURE SENSORS ON CHILLER-2).

· NEW BACNET OR MODBUS BASED PRIMARY NETWORK SERVER (THIS WILL USE THE

INTERNET TO PROVIDE ACCESS TO SYSTEM SETTINGS, ALARM MANAGEMENT,

GRAPHIC INTERFACE FOR THE BUILDING, AND SUPPORT THE NETWORK

CONTROLLERS).

· PROVIDE NEW NETWORK-LEVEL AREA CONTROLLERS FOR THE BUILDING, CENTRAL

PLANT, AND LAB BUILDING CAPABLE OF SUPPORTING BACNET/IP, BACNET MS/TP OR

MODBUS.

· NEW FIELD CONTROLLERS AT EACH MECHANICAL ROOM WITHIN THE FACILITY,

INCLUDING UPGRADE OF EXISTING CONTROL PANELS.

· REPLACE EXISTING UNIT CONTROLLERS, DAMPER AND VALVE ACTUATORS, SENSORS,

AND OTHER DEVICES.

· NEW LOW VOLTAGE/24VOLT WIRING OF EXISTING DEVICES, ENGINEERING, SEQUENCE

PROGRAMMING, AND GRAPHIC / INTERFACE COORDINATION.

· PRE-QUALIFIED BIDDERS INCLUDE THE FOLLOWING:

·· ALERTON - Climatec ·· SIEMENS - Digital Air Control, Inc ·· JOHNSON CONTROLS - Branch Office ·· RELIABLE CONTROLS - Unify Energy Solutions - Enviromatic ·· TRANE - Branch Office ·· DELTA - Team Solutions ·· DISTECH - Tekplan Solutions - Texas Air Systems - Climatec ·· CARRIER - iVu

P l o t t e d

D e c

P

M b y u s e r w m e i s t e r

S a v e d b y u s e r w m e i s t e r

C U s e r s w m e i s t e r A

C C

D o c s D

B R

I n c

T

X D

O T

L u f k i n

D

H Q

N i m b e r l a n d

D r

R e t r o f i t

H

V A

C

C o n t r o l s P r o j e c t

F i l e s D r a w i n g s C

C

O V

E R

S H

E E

T d w g

AutoCAD SHX Text V I C I N I T Y M A P

AutoCAD SHX Text E N L A R G E D B U I L D I N G M A P

AutoCAD SHX Text

CHECKED BY:

AutoCAD SHX Text

SHEET TITLE:

AutoCAD SHX Text

SHEET NUMBER:

AutoCAD SHX Text

PROJECT NUMBER:

AutoCAD SHX Text

DRAWN BY:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

REVISION:

AutoCAD SHX Text TXDOT LUFKIN DISTRICT OFFICE 1805 North Timberland Drive Lufkin, TX 75901

AutoCAD SHX Text

SEAL:

AutoCAD SHX Text 12/06/2023

AutoCAD SHX Text 230293.000

AutoCAD SHX Text No. / DATE / DISCRIPTION

AutoCAD SHX Text

01 12/04/2023 BID SET12/04/2023 BID SETBID SET

AutoCAD SHX Text

713.914.0888 v 713.914.0888 f 9990 Richmond Ave. South Bldg. Suite. 300 Houston, Texas 77042 TBPE Firm Registration NO. 2234

AutoCAD SHX Text

COVER SHEET

AutoCAD SHX Text

DBR

AutoCAD SHX Text

DBR

NORTH

P l o t t e d

D e c

P

M b y u s e r w m e i s t e r

S a v e d b y u s e r w m e i s t e r

C U s e r s w m e i s t e r A

C C

D o c s D c

T

X D f k i n

D m b e r l a n d

D r

R e t r o f i t

H

V A

C

C o n t r o l s P r o j e c t

F i l e s D r a w i n g s M d w g

NORTH

P l o t t e d

D e c

P

M b y u s e r w m e i s t e r

S a v e d b y u s e r w m e i s t e r

C U s e r s w m e i s t e r A

C C

D o c s D c

T

X D f k i n

D m b e r l a n d

D r

R e t r o f i t

H

V A

C

C o n t r o l s P r o j e c t

F i l e s D r a w i n g s M d w g

Sheets and Views
C0.01
M2.01.pdf
Sheets and Views
M2.01
M2.02.pdf
Sheets and Views
M2.02

File details come from the government source that posted it. Updated .