ESBD_File_349129_Main_Suite 638 Buildout Set Drawing 1.4.24.pdf
PDF 834 KB Posted
- Attached to
- TWC Main 6th Floor Buildout
- Solicitation number
- 3202400134
- Issued by
- Travis County, Austin City, Texas
About this file
This document contains drawings and specifications for a buildout project at the 6th floor of the Texas Workforce Commission's (TWC) Main Building located at 101 East 15th Street in Austin, Texas. The project involves accommodating new staff and making the required office modifications, including demolition of existing walls, construction of new walls, installation of new doors and frames, mechanical and electrical work, and various finish updates. The drawings provide the details for the demolition, new construction plans, mechanical and electrical plans. General notes and specifications are included for the construction materials, finishes, and installation requirements. The project is being bid for the jurisdictions of Travis County and the City of Austin.
The bid documents do not contain any pricing terms, set asides, or information about incumbent contractors. The project appears to be funded by the TWC, but the specific funding sources and amounts are not provided. The documents indicate the contractor will be required to coordinate the work with existing building elements and systems, and follow all applicable laws, codes, and safety requirements.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| ESBD_File_349129_Addendum 1.docx | DOCX document | |
| ESBD_File_349129_Vendor TCs (10-25-23).pdf | ||
| ESBD_File_349129_UGC 7.22.pdf | ||
| ESBD_File_349129_3202400134 Solicitation.docx | DOCX document | |
| ESBD_File_349129_Main_Suite 638 Buildout Set_Addendum 01.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SHEET INDEX
REVISION # SHEET # DRAWING TITLE
A-0.00 COVER SHEET
A-0.01 GENERAL INFORMATION
A-0.02 FINISH SCHEDULE
A-1.00 DEMOLITION PLAN (ENLARGED)
A-2.00 NEW CONSTRUCTION PLAN (ENLARGED)
M-1.00 MECHANICAL PLAN (ENLARGED)
E-1.00 ELECTRICAL PLAN (ENLARGED)
TYPICAL ROOM FINISHES, U.N.O.
ACT-1
PT-1
RB-1
CPT-1
GENERAL NOTES
G1. ALL CONTRACTORS SHALL BE RESPONSIBLE FOR VISITING THE PROJECT SITE & HAVING ASCERTAINED PERTINENT LOCAL CONDITIONS, SUCH AS LOCATION, ACCESSIBILITY, & GENERAL CHARACTER OF THE SITE & BUILDING. ALL CONTRACTORS SHALL THOROUGHLY UNDERSTANDS THE
CHARACTER & EXTENT OF PROPOSED WORK WITHIN & ADJACENT TO THE SITE.
G2. GENERAL CONTRACTOR TO COORDINATE ALL BLOCKING; LAYOUT DIMENSIONS & PENETRATIONS AS REQUIRED.
G3. ALL CONSTRUCTION MATERIALS, FIXTURES, FINISHES, ETC. ARE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS.
G4. CONTRACTOR TO PROVIDE PRODUCT CERTIFICATES & SHOP DRAWINGS OF ALL MILLWORK/CASEWORK & SAMPLES OF FINISHES & ARCHITECTURAL
SPECIALTY ITEMS FOR APPROVAL.
G5. CONTRACTOR TO PROVIDE WOOD BLOCKING BEHIND ALL WALL MOUNTED ITEMS.
G6. THESE DRAWING SHALL NOT BE SCALED FOR CONSTRUCTION PURPOSES. IN THE EVENT OF AN INCORRECT OR AN OMISSION OF NECESSARY
DIMENSIONS, CONTRACTOR SHALL NOTIFY PROJECT MANAGER.
G7. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL DIMENSIONS PRIOR TO CONSTRUCTION & NOTIFY PROJECT MANAGER OF ANY
DISCREPANCIES THAT COULD EFFECT THE DESIGN AND FINISH OUT OF THE PROJECT.
G8. DO NOT SUSPEND ANY ITEMS FROM METAL ROOF DECKS, HORIZONTAL BRIDGING, X-BRACING, PIPES, CONDUITS, OR ANY OTHER WORK BY OTHER
TRADES.
G9. EACH CONTRACTOR SHALL COMPLY WITH ALL PROVISIONS OF ALL APPLICABLE LAWS CODES ORDERS OF PUBLIC OFFICIALS WITH JURISDICTION
FOR SAFETY, PERSON, AND/OR PROPERTY.
G10. VERIFY WITH MANUFACTURER OR SUPPLIER THE SIZE, LOCATION. AND CHARACTERISTICS OF ALL WORK AND EQUIPMENT THAT IS TO BE INSTALLED BY CONTRACTOR AND/OR OTHER CONTRACTORS & FURNISHED BY OWNER PRIOR TO ANY CONSTRUCTION PERTAINING TO THE SAME IS
BEGUN.
G11. WHERE MULTIPLE FINISHES ARE LISTED IN THE SAME ROOM, OR ON THE SAME WALL, REFER TO NEW CONSTRUCTION PLANS AND/OR ELEVATIONS
FOR APPLICATION.
G12. ELEC. SWITCH/OUTLET & COVER PLATE COLOR TO BE WHITE, U.N.O.
G13. REFER TO COVER SHEET FOR ALL TYPICAL ROOM FINISHES.
G14. ALL KEYED NOTES MAY NOT BE USED ON EVERY SHEET.
G15. THE PROJECT MANAGER IS TO BE NOTIFIED OF ALL CEILING HEIGHT CHANGES OR CONFLICTS THAT DO NOT COMPLY WITH THESE DRAWINGS.
G16. ALL WORKERS MUST BE SIGNED IN WITH SECURITY DAILY. THE CONTRACTOR, THEIR EMPLOYEES, & SUB-CONTRACTORS ARE CONFINE WORK ACTIVITY ONLY TO WORK AREAS AS NOTED. ALL OTHER AREAS WITHIN TWC FACILITIES ARE PROHIBITED.
G17. WORK WILL REQUIRE COORDINATION WITH EXISTING ELEMENTS; INCLUDING CARPET, LIGHT FIXTURES, HVAC DUCTS, WIRING, AND PIPING. SOME
ELEMENTS MAY REQUIRE RELOCATION TO ACCOMMODATE NEW CONSTRUCTION.
TYPICAL OFFICE
Texas Workforce Commission
BUILDING AREA KEY PLAN
AutoCAD SHX Text 101 East 15th Street Room 122 Austin, Texas 78778-0001 Phone (512) 463-6463 FAX (512) 463-4705
AutoCAD SHX Text Date
AutoCAD SHX Text Rev. No.
AutoCAD SHX Text A-0.00
AutoCAD SHX Text Project Name and Address:
AutoCAD SHX Text
COVER SHEET
AutoCAD SHX Text
PRINTED ON: 01/04/2024
AutoCAD SHX Text
MAIN BUILDING - 6TH FLOOR
AutoCAD SHX Text
101 EAST 15TH STREET
AutoCAD SHX Text
AUSTIN, TEXAS 78778-0001
SYMBOLS LEGENDABBREVIATIONS
A.D.A.
A.F.F.
ALUM.
CL
CLG
CLR
CG
CONC.
CONT.
CORR(S).
DIA
DIM
DWG
EA.
ELEV.
EQ.
EXP.
FIXT.
FLR
F.D.
F.E.
FIN. FL
FMS
GALV.
GYP.
HDWD
HVAC
IN.
INSUL.
INT.
MAX.
MTL.
MIN.
N.I.C.
N.T.S.
O.C.
O.H.
U.N.O.
OFCI
PREFAB.
PLYD
RCP
SCHED.
SIM.
SQ.
TYP.
W W/
W/O V.I.F.
VWC
VTC
AMERICANS WITH DISABILITIES ACT
ABOVE FINISHED FLOOR
ALUMINUM
CENTERLINE
CEILING
CLEAR
CORNER GUARD
CONCRETE
CONTINUOUS
CORRIDOR(S)
DIAMETER
DIMENSION
DRAWING
EACH
ELEVATION
EQUAL
EXPANSION
FIXTURE
FLOOR
FLOOR DRAIN
FIRE EXTINGUISHER
FINISHED FLOOR
FACILITY MANAGEMENT SYSTEM
GALVANIZED
GYPSUM BOARD
HARDWOOD
HEATING VENTILATION AIR CONDITIONING
INCH
INSULATION
INTERIOR
MAXIMUM
METAL
MINIMUM
NOT IN CONTRACT
NOT TO SCALE
ON CENTER
OPPOSITE HAND
UNLESS NOTED OTHERWISE
OWNER FURNISHED CONTRACTOR INSTALLED
PREFABRICATED
PLYWOOD
REFLECTED CEILING PLAN
SCHEDULED
SIMILAR
SQUARE
TYPICAL
WIDTH
WITH/
WITHOUT/
VERIFY IN FIELD
VINYL WALL COVERING
VINYL COMPOSITION TILE
NOTE:
1. ALL ABBREVIATIONS LISTED ABOVE MAY NOT BE USED ON
THIS PROJECT.
2. ABBREVIATIONS FOR FINISHES CAN BE FOUND ON THE
FINISH SCHEDULE.
CEILING FINISH
WALL FINISH
BASE FINISH
FLOOR FINISH
COUNTERTOP/CABINET FINISH
APPLICABLE KEYED NOTES
DENOTES EXTENT OF A
SPECIFIC WALL FINISH
REVISION TAG
SECTION/DETAIL TAG
ELEVATION TAGS
KEYED NOTE TAG;
RE: KEYED NOTES LEGEND
ON SAME SHEET
DEMOLITION NOTE TAG;
RE: DEMOLITION NOTES
LEGEND ON SAME SHEET
DOOR NUMBER TAG
GENERAL CONSTRUCTION NOTES
GC1. CONTRACTOR TO PROTECT ALL EXISTING SURFACES & EQUIPMENT AGAINST DAMAGE AND DUST. PROVIDE POLY BARRIERS & MAINTAIN NEGATIVE AIR ATMOSPHERE WITHIN CONTAINED WORK ARE AT ALL TIMES. A RAM BOARD PATH IS REQUIRED FROM ALL ELEVATORS TO WORKS SITE AND MUST
BE PUT DOWN AND TAKEN UP AT THE END OF EACH WORK SHIFT.
GC2. FINISHED WALLS TO MATCH EXISTING USING STANDARD ACCESSORIES; GALVANIZED STEEL OR ROLLED ZINC CORNERBEAD, 2" WIDE PAPER TAPE BEDDED WITH READY-MIXED, VINYL-BASED JOINT COMPOUND & FINISHED WITH READY-MIXED, VINYL-BASED JOINT COMPOUND TO LEVEL 4 FINISH.
GC3. PROVIDE INDIVIDUAL, PRINTED LABELS AT NEW RECEPTICLES & SWITCHES INDICATING THE CONNECTED CIRCUIT.
GC4. LABEL NEW, ABOVE CEILING JUNCTION BOXES, INDICATING THE CONNECTED CIRCUIT USING PERMANENT MARKER.
GC5. FIRE ALARM DEVICES TO BE HANDLED BY OTHERS.
GC6. CONTRACTOR TO PROVIDE BLANK FACEPLATES FOR UNUSED RECEPTACLES.
PAINT
P1. CONTRACTOR SHALL PROVIDE 0'-6"X0'-6" MOCK UPS OF EACH PAINT COLOR AND SEND TO PROJECT MANAGER TO CONFIRM EACH PRIOR TO
APPLICATION.
P2. MECHANICAL GRILLES AND WALL DIFFUSERS, ELECTRICAL PANELS, ACCESS PANELS, ETC. WHICH ARE EXPOSED IN FINISHED SPACES SHALL BE
PAINTED, IN PROPER PAINT FORMULATION, TO MATCH THE SURFACE ON WHICH THEY OCCUR.
P3. TYPICAL OVERALL PAINT FINISHES (U.N.O.):
WALLS: EGG SHELL/SATIN
TRIM: SEMI-GLOSS
CEILING: FLAT
CMU: SEMI-GLOSS
DOORS & FRAME: SEMI-GLOSS
P4. ALL TOILET WALLS, AND CEILING PAINTS SHALL BE WASHABLE, SEMI-GLOSS FINISH.
P5. CONTRACTOR TO ENSURE THAT PAINT FORMULATION IS APPROPRIATE TO SUBSTRATE WHICH IT IS APPLIED.
P6. ALL GYPSUM BOARD SOFFITS AND CEILINGS SHALL BE PAINTED PT-2 U.N.O. IN ELEVATIONS.
WOOD
W1. ALL HARDWOOD TO BE ALDER OR APPROVED EQUAL. IF ALDER IS UNAVAILABLE, SAMPLE OF ALTERNATE WITH STAIN APPLIED TO BE PROVIDED TO
PROJECT MANAGER.
W2. ALL WOOD DIMENSIONS SHOWN ARE NOMINAL.
W3. ALL STAIN GRADE CUSTOM MILLWORK TO BE WD-1, U.N.O.
TRIM
TR1. PROVIDE INSIDE AND OUTSIDE CORNER TRIM PIECES AT ALL COVE TILE BASE SPECIFICATIONS.
TR2. ALL HOLLOW METAL DOORS AND FRAMES SHALL BE PAINTED TO MATCH THE ADJACENT WALL COLOR IN PROPER PAINT FORMULATION U.N.O.
TR3. ALL VINYL OR RUBBER BASE SHALL BE ADHERED AT TOP, BOTTOM, AND ANY SEAMS.
TR4. ALL STANDING & RUNNING MILLWORK TRIM SHALL BE PAINTED PT-2, U.N.O.
FLOORING
F1. ALL FLOORING MATERIAL TRANSITIONS SHALL OCCUR AT CENTER OF OPENING DEPTH.
F2. ALL TRANSITIONS AT DOORS SHALL OCCUR AT CENTERLINE OF DOOR THICKNESS U.N.O.
F3. ALL VINYL AND FLOOR TILE PATTERNS SHALL BE CENTERED ON ROOM U.N.O. NOTED ON NEW CONSTRUCTION PLANS.
CASEWORK
C1. ALL EXPOSED INTERIOR SURFACED OF ALL CABINETRY TO BE FINISHED TO MATCH EXTERIOR, U.N.O.
C2. ALL SEMI-EXPOSED SURFACES TO BE CLEAR FINISH.
C3. ALL CABINETS WITH ADJUSTABLE SHELVES TO HAVE 6MM Ø HOLES AT 64MM ON CENTER VERTICALLY FOR SHELF SUPPORTS.
C4. ALL DRAWER GLIDES TO HAVE A MINIMUM 100 LBS CAPACITY AND FULL EXTENSION, U.N.O.
C5. ALL CABINETRY HINGES TO BE CONCEALED SELF CLOSING HINGES, U.N.O.
C6. HARDWARE PULLS AT ALL FRONT OF HOUSE COMMON AREAS:
EQ-1 (REFER TO LIST OF FINISHES FOR EXACT SPECIFICATION)
HARDWARE PULLS AT ALL BACK OF HOUSE COMMON AREAS:
EQ-2 (REFER TO LIST OF FINISHES FOR EXACT SPECIFICATION)
Texas Workforce Commission
AutoCAD SHX Text
PT-3
AutoCAD SHX Text
XX
AutoCAD SHX Text
CF-X.XX
AutoCAD SHX Text
XX
AutoCAD SHX Text
CF-X.XX
AutoCAD SHX Text
ENLARGED PLAN TAG
AutoCAD SHX Text
XX-X
AutoCAD SHX Text
XX-X
AutoCAD SHX Text
XX-X
AutoCAD SHX Text
XX-X
AutoCAD SHX Text
XX-X/XX-X
AutoCAD SHX Text X, X, X
AutoCAD SHX Text
XX/CF-X.XX
AutoCAD SHX Text 101 East 15th Street Room 122 Austin, Texas 78778-0001 Phone (512) 463-6463 FAX (512) 463-4705
AutoCAD SHX Text Date
AutoCAD SHX Text Rev. No.
AutoCAD SHX Text A-0.01
AutoCAD SHX Text Project Name and Address:
AutoCAD SHX Text
GENERAL INFORMATION
AutoCAD SHX Text
PRINTED ON: 01/04/2024
AutoCAD SHX Text
MAIN BUILDING - 6TH FLOOR
AutoCAD SHX Text
101 EAST 15TH STREET
FINISH SCHEDULE
DATE: 7 November 2023
REVISED: --
LEGEND:
ACT
CG
CPT
EQ
FT
FWP
GL
MR
Acoustical Ceiling Tile Corner Guard Carpet (BL OR Modular) Equipment Floor Tile Fabric Wrapped Panel Glass Mirror
PL
PT
RB
RV
SC
STC
TB
TR
Plastic Laminate Paint Rubber Base Reveal Sealed Concrete Stained Concrete Tile Base Trim
VCT
VF
VWC
WB
WC
WF
WP
WT
Vinyl Composition Tile Vinyl Flooring (Tile, Plank, Sheet, etc.)
Vinyl Wallcovering Wood Base Wood Finish Wood Floor Wall Protection Wall Tile
KEY DESCRIPTION MANUFACTURER STYLE COLOR REMARKS REVISIONS
EQ-1 Sensor Switch Acuity Controls LTH WSD-PDT-WH White Switches to be placed at height consistent with existing throughout. --
EQ-2 Duplex Receptacles Hubbell CR20WHI White
See Electrical Plans for locations. Provide wire mold raceways at existing walls to match existing. To be place 15" A.F.F.
high. Connect to existing circuits as required.
EQ-3 Return Air Grille Hart & Cooley RE5T Series Aluminum Eggcrate
Return Air Grille #45500 22"x22" w/ Extended Framing for 24"x24"
White RE: Mech. Plan - M-1.00 for locations. --
EQ-4 Air Diffuser Accord Ventilation 961WI - T-Bar Steel 3-Cone Fixed-Pattern
High Volume Diffuser w/ Insulation White RE: Mech. Plan - M-1.00 for locations. --
GYP Gypsum board Fiberrock VHI (Very High ImPACT) Abuse-Resistant -- --
PT-1 Field Paint PPG/Monarch -- 511-3
Abbey White -- --
PT-2 Trim Paint PPG COMMERCIAL -- AC-4524 Black-Brown -- --
RB-1 Rubber Base ROPPE 700 Series Toe 4"
P193
BLACK BROWN -- --
Texas Workforce Commission
AutoCAD SHX Text 101 East 15th Street Room 122 Austin, Texas 78778-0001 Phone (512) 463-6463 FAX (512) 463-4705
AutoCAD SHX Text Date
AutoCAD SHX Text Rev. No.
AutoCAD SHX Text A-0.02
AutoCAD SHX Text Project Name and Address:
AutoCAD SHX Text
FINISH SCHEDULE
AutoCAD SHX Text
PRINTED ON: 01/04/2024
AutoCAD SHX Text
MAIN BUILDING - 6TH FLOOR
AutoCAD SHX Text
101 EAST 15TH STREET
5B
665A
651 645
646A
630 634
4A
4B
COPY
ROOM
5C
5D
Texas Workforce Commission
BUILDING AREA KEY PLAN
KEY DEMOLITION NOTES
1. REMOVE AND SALVAGE EXISTING DOOR AND FRAME. PATCH AND
PAINT ALL EFFECTED SURFACE TO MATCH ADJACENT FINISHES.
2. DEMOLISH EXISTING WALLS, PATCH, AND PAINT ALL EFFECTED
SURFACE TO MATCH ADJACENT FINISHES AS NEEDED.
AutoCAD SHX Text 101 East 15th Street Room 122 Austin, Texas 78778-0001 Phone (512) 463-6463 FAX (512) 463-4705
AutoCAD SHX Text Date
AutoCAD SHX Text Rev. No.
AutoCAD SHX Text
SCALE: N/A
AutoCAD SHX Text Floor Plan - Main Building
AutoCAD SHX Text A-1.00
AutoCAD SHX Text
AutoCAD SHX Text
DEMOLITION PLAN (ENLARGED)
AutoCAD SHX Text
AutoCAD SHX Text 01/04/2024
AutoCAD SHX Text
MAIN BUILDING - 6TH FLOOR
AutoCAD SHX Text
101 EAST 15TH STREET
AutoCAD SHX Text
AUSTIN, TEXAS 78778-0001
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
665A
651 645
646A
630 634
4A
COPY
ROOM
5C
5D
5B
665A
651 645
646A
630 634
4A
COPY
ROOM
5C
5D
Texas Workforce Commission
BUILDING AREA KEY PLAN
KEYED CONSTRUCTION NOTES
AutoCAD SHX Text 23'-5"
AutoCAD SHX Text 11'-8"
AutoCAD SHX Text 13'-4"
AutoCAD SHX Text 17'-6"
AutoCAD SHX Text 33'-11"
AutoCAD SHX Text 13'-2"
AutoCAD SHX Text 8'-4"
AutoCAD SHX Text 11'-8"
AutoCAD SHX Text 7'-5"
AutoCAD SHX Text 11'
AutoCAD SHX Text 101 East 15th Street Room 122 Austin, Texas 78778-0001 Phone (512) 463-6463 FAX (512) 463-4705
AutoCAD SHX Text Date
AutoCAD SHX Text Rev. No.
AutoCAD SHX Text
AutoCAD SHX Text Floor Plan - Main Building
AutoCAD SHX Text
SCALE: N/A
AutoCAD SHX Text
1. PROVIDE & INSTALL 3'-0" X 7'-0" TIMELY, OR EQUAL, DARK BRONZE PRE-FINISHED KD DOOR FRAME AND SOLID CORE MOHAWK PROVIDE & INSTALL 3'-0" X 7'-0" TIMELY, OR EQUAL, DARK BRONZE PRE-FINISHED KD DOOR FRAME AND SOLID CORE MOHAWK DOOR IN BIRCH CLEAR. USE HAGER, OR EQUAL, 4.5X4.5 HINGES. USE BEST 7K SERIES GRADE CYLINDRICAL LOCK, THAT ACCEPTS BEST 7-PIN INTERCHANGEABLE CORES. USE AB-FUCTION 15D LEVELR, 626 FINISH. USE DOOR STOP TRI 1211 STOP 613. ALL COMPONENTS LEVELR, 626 FINISH. USE DOOR STOP TRI 1211 STOP 613. ALL COMPONENTS TO MATCH EXISTING. 2. PROVIDE & INSTALL 3'-0" X 7'-0" HOLLOW-METAL DOOR FRAME & 20-MINUTE FIRE RATED SOLID CORE WILSONART DOOR IN WILD CHERRY LAMINATE FINISH. USE HAGER, OR EQUAL, 4.5X4.5 HINGES. USE BEST 9K SERIES GRADE CYLINDRICAL LOCK, THAT ACCEPTS BEST 7-PIN INTERCHANGEABLE CORES. USE AB-ENTRY FUCTION 15D LEVELR, 613 FINISH. USE DOOR STOP TRI 1211 STOP 613. USE FALCON SC-81 FC CLOSURE RWPA IN DARK BRONZE. ALL COMPONENTS TO MATCH EXISTING. 3. CONSTRUCT NEW WALL UP TO DECK. USE 5/8" TYP. GYMSUM BOARD AND 3" 5/8 STUDS 16" O.C. ON TRACK ABOVE CEILING GRID TYP. GYMSUM BOARD AND 3" 5/8 STUDS 16" O.C. ON TRACK ABOVE CEILING GRID AND 3" 5/8 STUDS 16" O.C. ON TRACK ABOVE CEILING GRID AND TILE. PROVIDE MINIMUM R-11 FIBERGLASS BATT INSULATION. FIRE-TAPE & FLOAT USING VINYL BASED JOINT COMPOUND TO LEVEL LEVEL 4 FINISH. TEXTURE AND PAINT TO MATCH EXISTING ADJACENT SURFACES. TEXTURE AND PAINT TO MATCH EXISTING ADJACENT SURFACES. 4. CONSTRUCT NEW WALLS, UP TO EXISTING CEILING, USING GALVANIZED STEEL TRACK & STUDS @ 16" O.C., PROVIDE MINIMUM R-11 FIBERGLASS BATT INSULATION AND 5/8" TYPE X GYPSUM DRYWALL ON EITHER SIDE. TAPE & FLOAT USING VINYL BASED JOINT COMPOUND TO LEVEL 4 FINISH. TEXTURE AND PAINT TO MATCH EXISTING ADJACENT SURFACES. 5. INFILL DOOR CAVITY, MATCH WIDTH OF ADJACENT WALL USING 3-5/8" X 25 GAUGE GALVANIZED STEEL TRACK & STUDS @ 16" O.C., PROVIDE MINIMUM R-11 FIBERGLASS BATT INSULATION AND 5/8" TYPE X GYPSUM DRYWALL ON EITHER SIDE. TAPE & FLOAT USING VINYL BASED JOINT COMPOUND TO LEVEL 4 FINISH. TEXTURE AND PAINT TO MATCH EXISTING ADJACENT SURFACES. 6. PROVIDE & INSTALL SINGLE-WIDTH ROUGH IN JUNCTION BOX & 3/4" CONDUIT ABOVE CEILING LINE FOR VOICE & LAN LOCATIONS, CABELING BY OTHERS. PROVIDE WIRE MOLD RACEWAYS AT EXISTING WALLS, TO BE PLACED AT 15" A.F.F. HEIGHT. PROVIDE & INSTALL BLANK FACEPLATES. 7. PAINT ALL WALL SURFACES WITHIN ESTABLISHED WORK AREA. ONE COAT PRIME OF PVA PRIMER. FOR INTERIOR WALLS AND OFFICES: USE TWO COATS OF SHERWIN WILLIAMS FINISH COAT, PROMAR 200, ZERO VOC INTERIOR LATEX PAINT. FOR CORRIDOR WALLS: USE TWO SHERWIN WILLIAMS FINISH COAT, PROMAR 200, ZERO VOC INTERIOR LATEX PAINT. FOR CORRIDOR WALLS: USE TWO FINISH COAT, PROMAR 200, ZERO VOC INTERIOR LATEX PAINT. FOR CORRIDOR WALLS: USE TWO PROMAR 200, ZERO VOC INTERIOR LATEX PAINT. FOR CORRIDOR WALLS: USE TWO . FOR CORRIDOR WALLS: USE TWO COATES OF PPG FINISH COAT, SPEEDHIDE ZERO INTERIOR ZERO VOC LATEX PAINT. PPG FINISH COAT, SPEEDHIDE ZERO INTERIOR ZERO VOC LATEX PAINT. FINISH COAT, SPEEDHIDE ZERO INTERIOR ZERO VOC LATEX PAINT. PEEDHIDE ZERO INTERIOR ZERO VOC LATEX PAINT. 8. MOVE FIRE ALARM TO NEW WALL. TO BE DONE BY OTHERS. 9. CEILING HEIGHT TO MATCH EXISTING AT OFFICES AND OPEN OFFICE AREA. 10. INSTALL NEW BASEBOARD AT NEW OR REPAIRED WALLS.
AutoCAD SHX Text
NEW CONSTRUCTION PLAN (ENLARGED)
AutoCAD SHX Text A-2.00
AutoCAD SHX Text
PRINTED ON: 01/04/2024
AutoCAD SHX Text
MAIN BUILDING - 6TH FLOOR
AutoCAD SHX Text
101 EAST 15TH STREET
AutoCAD SHX Text
AUSTIN, TEXAS 78778-0001
AutoCAD SHX Text
FA
FA
665A
651 645
646A
630 634
4A
COPY
ROOM
5C
5D
5B
665A
651 645
646A
630 634
4A
COPY
ROOM
5C
5D
Texas Workforce Commission
LEGEND
EXISTING 24"x48" RECESSED LIGHT
BAR. ADJUST AS NEEDED.
EXISTING 24"x24" RECESSED LIGHT
BAR. ADJUST AS NEEDED.
EXISTING 24''X24''; SUPPLY DIFFUSER.
ADJUST AS NEEDED.
KEYED MECHANICAL NOTES
1. PROVIDE SUPPLY DIFFUSER, MANUAL VOLUME DAMPER, AND DUCT WORK. FLEXIBLE
DUCT WORK SHALL BE SUSPENDED FROM OVERHEAD STRUCTURE AND NOT REST ON LIGHT
FIXTURES. TAP INTO THE EXISTING DUCT WORK.
2. PROVIDE AND INSTALL 2'X2' TRANSFER GRILL FOR RETURN AIR AS PER THE REFLECTED
CEILING PLAN.
3. LIGHT FIXTURES CAN BE ADJUSTED AS NEEDED DURING CONSTRUCTION.
AutoCAD SHX Text 101 East 15th Street Room 122 Austin, Texas 78778-0001 Phone (512) 463-6463 FAX (512) 463-4705
AutoCAD SHX Text Date
AutoCAD SHX Text Rev. No.
AutoCAD SHX Text
AutoCAD SHX Text Floor Plan - Main Building
AutoCAD SHX Text
SCALE: N/A
AutoCAD SHX Text M-1.00
AutoCAD SHX Text
MECHANICAL PLAN (ENLARGED)
AutoCAD SHX Text
PRINTED ON: 01/04/2024
AutoCAD SHX Text
MAIN BUILDING - 6TH FLOOR
AutoCAD SHX Text
101 EAST 15TH STREET
665A
651 645
646A
630 634
4A
COPY
ROOM
5C
5D
5B
665A
651 645
646A
630 634
4A
COPY
ROOM
5C
5D
Texas Workforce Commission
GENERAL ELECTRICAL NOTES
1. THIS PLAN IS ISSUED WITH THE INTENT OF PROVIDING THE CONTRACTOR WITH
DESIGN INFORMATION AVAILABLE AT THIS PHASE. THIS PLAN DOES NOT COVER ALL
CONSTRUCTION ISSUES. ADDITIONAL INFORMATION WILL BE SUBMITTED
THROUGHOUT THE COURSE OF THE CONSTRUCTION PROCESS.
2. ELECTRICAL AND DATA CONNECTIONS TO BE AT 15" A.F.F. U.N.O.
LEGEND
DUPLEX ELEC.
RECEPTACLE
(EXISTING)
DUPLEX ELEC.
RECEPTACLE
DATA CONNECTION
SINGLE POLE
SWITCH
TV LOCATION
(EXISTING)
BUILDING AREA KEY PLAN
AutoCAD SHX Text 101 East 15th Street Room 122 Austin, Texas 78778-0001 Phone (512) 463-6463 FAX (512) 463-4705
AutoCAD SHX Text Date
AutoCAD SHX Text Rev. No.
AutoCAD SHX Text
AutoCAD SHX Text Floor Plan - Main Building
AutoCAD SHX Text
SCALE: N/A
AutoCAD SHX Text E-1.00
AutoCAD SHX Text
ELECTRICAL PLAN (ENLARGED)
AutoCAD SHX Text E
AutoCAD SHX Text
TV
AutoCAD SHX Text E
AutoCAD SHX Text
PRINTED ON: 01/04/2024
AutoCAD SHX Text
MAIN BUILDING - 6TH FLOOR
AutoCAD SHX Text
101 EAST 15TH STREET
AutoCAD SHX Text
AUSTIN, TEXAS 78778-0001
AutoCAD SHX Text E
AutoCAD SHX Text
TV
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
E
| Sheets and Views |
| LIVE_Main_A-0.00_COVER SHEET-A-0.00_11x17 |
| LIVE_Main_A-0.00_COVER SHEET-A-0.01_11x17 |
| LIVE_Main_A-0.00_COVER SHEET-A-0.02_11x17 |
| LIVE_Main_A-1.00_DEMOLITION PLAN ENLARGED-Tablet - 11X17 |
| live_Main__A-2.00_NEW CON PLAN-Layout1-Tablet - 11X17 - A |
| LIVE_Main_M-1.00_MECHANICAL PLAN ENLARGED-Layout1-Tablet - 11X17 |
| LIVE_Main_E-1.00_ELECTRICAL PLAN ENLARGED-Layout1-Tablet - 11X17 |
File details come from the government source that posted it. Updated .