This document is a notice for a State and Local contract opportunity issued by the Texas Department of Transportation (TxDOT) for Fencing & Security Upgrades in the Atlanta District. The project includes furnishing, installing, and programming access control, card readers, door hardware, gate operators, fencing, and security cameras across 7 sites in several counties. The estimated cost of the project is $2,564,450. A mandatory pre-bid meeting and site visits are scheduled for August 1-2, 2023, with bids due on September 5, 2023 at 1:00 PM CT. The contract award will be made by the Texas Transportation Commission, typically scheduled on the last Thursday of each month. The use of a HUB Subcontracting Plan is required as the project estimate exceeds $100,000.

Pricing for the contract will be based on the submitted bids. This is an open competitive bid, and there are no set-asides or incumbent information provided. The project is funded by TxDOT, and bidders must comply with all applicable state laws and regulations. Additional details on the specific products, services, quantities, and technical requirements are provided in the contract documents.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ATLANTA DISTRICT (7 SITES)

FENCING & SECURITY UPGRADE

SCOPE OF WORK

Support Services Division / Facilities Planning & Management 6230 E. Stassney Lane Austin, Texas 75744

Project Manager Joseph Alexander

(512) 662-3591 joseph.alexander@txdot.gov

ATLANTA DISTRICT (19)

PROJECT ID# 19-470424501

TEXARKANA AEM FACILITY

520 Sowell Ave, TEXARKANA, TX 75501 SITE

NO. 199790, BOWIE COUNTY

PROJECT ID# 19-470424502

NEW BOSTON MNT FACILITY

406 MCCOY BLVD., NEW BOSTON, TX 75570

SITE NO. 199791, BOWIE COUNTY

PROJECT ID# 19-470424503

MOUNT PLEASANT AEM FACILITY

2210 FERGUSON RD, MT. PLEASANT, TX 75455

SITE NO. 199794, TITUS COUNTY

PROJECT ID# 19-470424504

DAINFERFIELD MNT FACILITY

US 259 NORTH, DAINGERFIELD, TX 75638

SITE NO. 199698, MORRIS COUNTY

PROJECT ID# 19-470424505

GILMER AEM FACILITY

2433 US-271, GILMER, TX 75644

SITE NO. 199617, UPSHUR COUNTY

PROJECT ID# 19-470424506

MARSHALL AEM FACILITY

300 E. LOOP 390 NORTH, MARSHALL, TX 75670

SITE NO. 199040, HARRISON COUNTY

PROJECT ID# 19-470424507

LINDEN MNT FACILITY

689 STATE HWY 8, LINDEN ,TX 75563

SITE NO. 199004, CASS COUNTY

GENERAL NOTES:

1. Work shall conform to the construction documents & all applicable building codes (including federal & state codes, ordinances, regulations, etc.) Construction documents include all drawings, specifications, addenda, standard conditions, and contract agreement.

2. Construction Documents are intended to include items necessary to convey design intent of the work. Manufacturers' instruction shall be considered as part of the specifications whether included or not in the specification manual.

3. Periodic site visits by Owner's Representative shall not be constructed as supervision of means, methods, techniques, sequences or procedures for constriction, nor imply responsibility for providing a safe place for performance of work by contractors, subcontractors, employees of suppliers.

4. The Details designated as "Typical Details" apply generally to the drawings in all areas where conditions are similar to those described in the details.

5. Contractor shall be responsible to abide by all OSHA Standards.

6. Contractor Shall:

Verify dimensions & field conditions before proceeding.

Notify Architect or Owner of field conditions requiring deviations from construction documents prior to any modifications.

Provide adequate bracing & shoring as necessary until permanent supports are installed.

Repair or replace damaged or defective work to the approval of the Owner, at no additional cost to the Owner.

Notify Owner at critical construction milestones in order to obtain necessary approvals & inspections prior to commencement of subsequent work.

COVER SHEET

Dated: 07/10/2023

This Project Includes furnish, install, and program access control, card readers, electrified locksets, door position sensors, gate releases, control panels, intercoms, access control cabling, gate operators, surge protection, card reader pedestals, and CCTV. Demolition of existing chain-link fencing and gates, clearing of trees, bush and vines, furnish and install new link fencing with top rail 3 strand barb wires and grounding.

Furnish and install cantilever gates, V track gates, gate operators with safeties, safety loops and associated safety devices. Install TXDOT furnished pedestals & pedestal base. Furnish and install concrete pedestal base foundation, pedestal card readers, intercoms, CCTV and required surge protection, control and power wiring.

PROJECT ID# 19-4704240501

DRAWING INDEX

DRAWING # DRAWING DESCRIPTION

TY 0.1

DEVICE LEGEND & KEYED NOTES

DF TY 1.0

SITE PLAN

DF TY 1.1

ADMIN

GL TY 1.0

SITE PLAN

GL TY 1.1

ADMIN

GL TY 1.2

SHOP

LN TY 1.0

SITE PLAN

LN TY 1.1

ADMIN

DRAWING INDEX

DRAWING # DRAWING DESCRIPTION

MR TY 1.0

SITE PLAN

MR TY 1.1

ADMIN

MR TY 1.2

SHOP/WRHS

MR TY 1.3

STORAGE

MP TY 1.0

SITE PLAN

MP TY 1.1

ADMIN

MP TY 1.2

SHOP

NB TY 1.0

SITE PLAN

NB TY 1.1

ADMIN

SITE PLAN

TX TY 1.0

ADMIN

TY 5.1

CANTILEVER GATE DETAILS

TY 5.5

PERSONNEL GATE DETAILS

TY 5..6 GATE OPERATOR DETAILS

DRAWING INDEX

DRAWING # DRAWING DESCRIPTION

PEDESTAL DETAILS

TY 5.8

PEDESTAL BASE DETAILS

TY 5.9

BOLLARD, TRENCH &

UERGROUND JBOX DETAILS

TY 5.10

CANTILEVER GATE CONCRETE

TROUGH

TY 5.11 CHAIN LINK V TRACK GATE AND

V TRACK CONCRETE TROUGH

TY 6.0

DOOR CABLING DETAIL

TY 6.1 DOOR SCHEDULE DETAIL

TY 6.2 DOOR SCHEUDLE DETAIL

TY 6.3

DOOR SCHEDULE DETAIL

TY 6.8

DOOR SCHEDULE DETAIL

TY 6.11 DOOR SCHEDULE DETAIL

TY 6.12 DOOR SCHEDULE DETAIL

TY 6.13

DOOR SCHEDULE DETAIL

TY 6.14 DOOR SCHEDULE DETAIL

DRAWING INDEX

DX 0.01

Xref T:\SSD_FM_PROJECTS\ATL_19\ATL(19)_SECURITY PROJECTS\ATLANTA FY 18-19 SECURITY PROJECTS\01_DESIGN\XREFS\X_REVITTLBLK CARTHAGE.dwg

Support Services Division / Facilities Planning & Management

Date: 7/10/8023

Drawn by: JA/DM

Checked by: JA/DM

No. Description Date

Copyright © 2015 Texas Department of Transportation

Texas Department of Transportation 125 E. 11th Street Austin, Texas 78701-2483

A

TL

A N

TA

D

IS

TR

IC

T

(7 S

IT

ES

FE

N C

IN

G

S

EC

U

R

IT

Y U

PG

R

A D

E P

R O

J E

C T

1, 2, 3, 4, 5, 6, REV 1

REV 2

REV 3

REV 4

REV 5

REV 6

REV 7

REV 8

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

6230 E. STASSNEY LANE, AUSTIN, TEXAS 78744

TY 5.7

COVER COVER SHEET

TX TY 1.1

DMARTYNO

Line

NVR

SWH CCURE ULTRA CONTROLLER

GLASS BREAK DETECTOR - SEE KEY NOTE 2

CARD READER

DESCRIPTIONSYMBOL

DEVICE LEGEND

SWH CCURE EDGE HOFFMAN CONTROLLER

MINI DOME CAMERA - SEE KEY NOTES 9 & 15

CR

GB

INTERIOR CEILING MOUNTED SPEAKER

GR GATE RELEASE BUTTON

PB PANIC CALL BUTTON

CR

LR

INTERCOM (WEATHERPROOF)IC

CARD READER (LONG RANGE) - SEE PEDESTALS

X KEYED NOTE

I

MONITOR & VIDEO DECODER

DOR DOOR RELEASE BUTTON

NETWORK VIDEO RECORDER

IS

S L STROBE LIGHT EXTERIOR (WEATHER PROOF)

P PEDESTAL - REFERNCE KEY NOTE 9, 10 & 11

GATE OPERATOR - REFERENCE NOTE 13

B BOLLARD - REFERNCE KEY NOTE 12

KEY NOTES

FURNISH, INSTALL, CONNECT AND PROGRAM TO CCURE SYSTEM

CONTACTS TO ALL EXTERIOR DOORS, OVERHEAD GARAGE DOORS,

ROOF HATCH DOORS, PERSONNEL GATES AND VEHICLE GATES.

FURNISH, INSTALL, CONNECT AND PROGRAM TO CCURE SYSTEM GLASS

BREAK DETECTORS TO COVER ALL EXTERIOR GLASS UP TO 10FT ABOVE

OUTSIDE GROUND COVER.

FURNISH, INSTALL, CONNECT AND PROGRAM TO CCURE SYSTEM INTERIOR

SPEAKER/SPEAKERS. EXTERIOR STROBE AND PRE-RECORDED SOUNDER

FOR INTRUSION DETECTION. COORDINATE STROBE LIGHT LOCATION WITH

TXDOT PROJECT MANAGER.

3 FURNISH AND INSTALL NVR(S), CAMERA(S), MONITOR(S). COORDINATE

FINAL LOCATION WITH TXDOT PROJECT MANAGER

5 NOT USED

DISCONNECT AND REMOVE EXISTING DOOR HARDWARE, MAG LOCKS,

DOOR RELEASE BUTTON AND ASSOCIATED EQUIPMENT.

FURNISH, INSTALL DOOR HARDWARE AND MFG RECOMMENDED POWER

SUPPLY AS INDICATED AT LOCATION IN DRAWING . CONNECT TO CARD

ACCESS. INSURE PROPER OPERATION IS RESTORED.

REPLACE EXISTING iSTAR PRO AND EX PANELS, POWER SUPPLIES, AND

DEVICE POWER SUPPLIES WITH LIFESAFETY POWER FLEXPOWER MODEL

FP0150/250-2D8E8S AND SWH ULTRA SE BOARDS OR APPROVED EQUAL.

REUSE EXISTING SWH I/O BOARDS . PROVIDE A MINIMUM OF 20% CARD

READER SPACE FOR FUTURE AND 20% INPUTS AND OUTPUTS AVAILABLE

FOR FUTURE NEEDS

REPLACE XX EXISTING SWH-4000 AND SWH 4100 READERS WITH WALL

MOUNT HID® 920PHRNEK00005 RP40-H MULTI-CLASS SE OR MULLION

MOUNT HID® 900PHRNEK00005 RP10-H MULTI-CLASS SE AT APPROVED

LOCATIONS. FIELD VERIFY LOCATIONS FOR BIDDING AND INSTALLATION.

NEW READERS TO BE FLUSH MOUNTED TO WALL. READER

CONNECTIONS TO BE SOLDERED AND HEAT SHRINKED AT EXTERIOR

READER LOCATIONS. DISCONNECT AND REMOVE 2 EA INTRUSION

READER FROM WALL AT PANEL AND FROM PROGRAMMING. FURNISH

AND INSTALL BLANK COVER MATCH EXISTING PLATE COLORS.FIELD

VERIFY LOCATIONS FOR BIDDING AND INSTALLATION FIELD VERIFY

LOCATIONS FOR BIDDING AND INSTALLATION

OPTION A: INSTALL TXDOT FURNISHED CARD READER PEDESTAL AND

BASE. REMOVE ALL EXISTING GATE READERS. CONNECT NEW TXDOT

PROVIDED PEDESTAL TO EXISTING GATE OPERATOR AND EXIT LOOPS.

FURNISH AND INSTALL ALL SAFETY DEVICES TO BE UL 325

COMPLIANT,TWO INDEPENDENT SAFETY ENTRAPMENT PROTECTION

DEVICES MUST BE INSTALLED AT EACH ENTRAPMENT.

FURNISH, INSTALL AND PROGRAM ALL ASSOCIATED EQUIPMENT .

OPTION B: INSTALL TXDOT FURNISHED CARD READER PEDESTAL AND

BASE. REMOVE ALL EXISTING GATE READERS. CONNECT NEW TXDOT

PROVIDED PEDESTAL TO EXISTING GATE OPERATOR AND EXIT LOOPS.

FURNISH AND INSTALL ALL SAFETY DEVICES TO BE UL 325

COMPLIANT,TWO INDEPENDENT SAFETY ENTRAPMENT PROTECTION

DEVICES MUST BE INSTALLED AT EACH ENTRAPMENT.

FURNISH, INSTALL AND PROGRAM ALL ASSOCIATED EQUIPMENT.

OPTION C: INSTALL TXDOT FURNISHED CARD READER PEDESTAL AND

BASE. REMOVE ALL EXISTING GATE READERS. CONNECT NEW TXDOT

PROVIDED PEDESTAL TO EXISTING GATE OPERATOR AND EXIT LOOPS.

FURNISH AND INSTALL ALL SAFETY DEVICES TO BE UL 325

COMPLIANT,TWO INDEPENDENT SAFETY ENTRAPMENT PROTECTION

DEVICES MUST BE INSTALLED AT EACH ENTRAPMENT.

FURNISH, INSTALL AND PROGRAM ALL ASSOCIATED EQUIPMENT.

12 FURNISH AND INSTALL BOLLARD - REFER TO DRAWING TY 5.9 DETAIL 3

FURNISH AND INSTALL NEW GATE OPERATOR: MFG; LIFTMASTER INSL24UL

OR IHS24UL GATE OPERATOR. 120 VOLT SINGLE PHASE. FURNISH, INSTALL

NEW SAFETY LOOPS AND SAFETY DEVICES TO COMPLY WITH UL 325

CLASS IV COMPLIANCE. FURNISH AND INSTALL CARD READER TO OUTSIDE

OF CABINET. CONNECT AND PROGRAM GATE INTO EXISTING CCURE.

EXPAND CCURE SYSTEM AS REQUIRED. PERFORM UTILITY SCAN OF SAW

CUT AND TRENCHING AREA IN DRIVE. SAW CUT DRIVE AND TRENCH FROM

GATE OPERATOR TO BUILDING. FURNISH AND INSTALL 2 EA (1-1/4" ELECT &

2" COMM) CONDUITS FROM GATE OPERATOR TO BUILDING. ELECTRICAL

CONDUIT AT BLDG TO ELECTRICAL PANEL 1-1/4" EMT WITH RAIN TIGHT

FITTINGS (2 EA #10 THHN AND 1 EA #12 GROUND. FURNISH AND INSTALL

NEW 2 POLE 20 AMP BREAKER FOR GATE OPERATOR. COMM CONDUIT

SHALL BE EXTENDED TO INTERIOR ROOF JOIST.

TRENCH SHALL BE CAPPED WITH 6" MINIMUM CONCRETE.

ELECTRICAL WORK SHALL BE PERFORMED BY A LICENSED MASTER

ELECTRICIAN WITH THE STATE OF TEXAS.

REMOVE TREES, BUSHES AND VINES 2'FT FEET ON EACH SIDE OF TXDOT

PROPERTY FENCE LINE. WHEN EXISTING FENCE LINE BORDERS ANOTHER

PROPERTY, CLEAR ONLY ON TXDOT SIDE. COORDINATE WITH TXDOT

PROJECT MANAGER. FIELD VERIFY DISTANCES FOR BIDDING AND

INSTALLATION

KEY NOTES

DEMO AND DISPOSE OF EXISITNG FENCE, POSTS, 3 STRAND BARBED

WIRE & ASSOCIATED HARDWARE. BACKFILL AND COMPACT POST HOLES

BELOW GRADE. FIELD VERIFY FOR BIDDING AND INSTALLATION.

19 REMOVE AND DISPOSE OF EXISTING VEHICLE GATES.

FURNISH AND INSTALL 6' FT 9 GAUGE CHAIN LINK FENCE WITH TOP

RAIL AND 3 STRAND BARBED WIRE. FIELD VERIFY DISTANCES FOR

BIDDING AND INSTALLATION.

FURNISH AND INSTALL ORNAMENTAL FENCE 7' FT HEIGHT 3 RAIL. MFG

AMERISTAR MONTAGE COMMERCIAL INVINCIBLE OR APPROVED EQUAL.

FIELD VERIFY DISTANCE FOR BIDDING AND INSTALLATION.

FURNISH AND INSTALL 9 GAUGE CORE AND 8 GAUGE FINISH, 6' FT BLACK

VINYL COATED GALVANIZED CHAIN LINK FENCE WITH TOP RAIL AND

3 STRAND BARBED WIRE. FIELD VERIFY DISTANCES FOR BIDDING AND

INSTALLATION.

DEMO AND DISPOSE OF EXISTING 3 STRAND BARBED WIRE. FURNISH AND

INSTALL NEW TOP RAIL. FURNISH AND INSTALL NEW 3 STAND BARBED

WIRE. REPLACE ALL DAMAGED OR RUSTED EXTENSION ARMS FOR

3 STRAND BARBED WIRE. FIELD VERIFY DISTANCES AND QUANTITIES FOR

BIDDING AND INSTALLATION.

DEMO EXISTING PEDESTAL(S), BOLLARD(S) AND CONCRETE PAD(S).

FURNISH AND INSTALL NEW TOP RAIL, EXTENSION ARMS FOR 3 STRAND

BARBED WIRE AND 3 STRAND WIRE. FIELD VERIFY DISTANCES FOR

BIDDING AND INSTALLATION.

25 FURNISH AND INSTALL NEW TOP RAIL. FIELD VERIFY DISTANCES FOR

BIDDING AND INSTALLATION.

FURNISH AND INSTALL 6' FT DENSITY POLYETHYLENE 2" BOTTOM LOCK

PRIVACY SLATS. FIELD VERIFY DISTANCES FOR BIDDING AND

INSTALLATION.

27 FURNISH AND INSTALL 6' FT 9 GAUGE CHAIN LINK CANTILEVER GATE

WITH 3 STRAND BARBED WIRE. REFER TO DRAWING TY 5.1

28 FURNISH AND INSTALL CONCRETE TROUGH FOR CANTILEVER (CHAIN LINK

OR ORNAMENTAL) GATES. REFER TO DRAWING TY 5.10

29 FURNISH AND INSTALL 6' FT 9 GAUGE CHAIN LINK V-TRACK GATE WITH

3 STRAND BARBED WIRE. REFER TO DRAWING TY 5.11

30 FURNISH AND INSTALL CONCRETE TROUGH FOR CHAIN LINK V-TRACK

GATE. REFER TO DRAWING TY 5.11

FURNISH AND INSTALL NEW PERSONNEL GATE, CARD READER (MULLION

MOUNT HID® 90PHRNEK00005 RP10-H MULTI-CLASS SE MULLION MOUNT),

ELECTRIFIED CYLINDRICAL LEVER SET WITH REX, DOOR CONTACT AND

GATE CLOSURE. REFER TO DRAWING TY 5.5.

FURNISH INSTALL 3/4" SCHEDULED 40 PVC FROM PERSONNEL GATE TO

BUILDING AND 3/4" EMT WITH RT CONNECTORS INTERIOR OF BUILDING TO

NEAREST CCURE PANEL AND LOCKING POWER SUPPLY.

FURNISH AND INSTALL NEW TOP RAIL, EXTENSION ARMS FOR 3 STRAND

BARBED WIRE AND 3 STARNDED BARBED WIRE. FIELD VERIFY DISTANCES

FOR BIDDING AND INSTALLATION.

FURNISH AND INSTALL ORNAMENTAL 7' FT HEIGHT CANTILEVER GATES.

MFG: AMERISTAR MONTAGE COMMERCIAL INVINCIBLE 3 RAIL OR

APPROVED EQUAL. CONNECT TO NEW GATE OPERATOR.

DEVICE LEDGEND

& KEY NOTES

TY 0.1

SITE SECURITY SYSTEM

UPGRADE AND

INSTALLATION PROJECT

Facilities Planning & Management

Date: 7/10/2023

Drawn by: JA/DM

Checked by: JA/DM

No. Description Date

Copyright © 2015 Texas Department of Transportation

Texas Department of Transportation 125 E. 11th Street Austin, Texas 78701-2483

TE

XA

S D

EP

AR

TM

EN

T O

F

TR

AN

SP

O R

TA

TI

O N

SE

C

U R

IT

Y

SY

ST

EM

S

U

PG

R

AD

E

REV 1

REV 2

REV 3

REV 4

REV 5

REV 6

REV 7

REV 8

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

SWH CCURE EDGE LIFESAFETY CONTROLLER

CAM

FURNISH AND INSTALL 1 EA VIKING MODEL E-30-EQP, VKWEX5 BACKBOX.

FURNISH AND INSTALL NEW SINGLE SENSOR CAMERA. VERIFY LOCATION

AND MOUNTING APPLICATIONS/HARDWARE WITH TXDOT PM.

FURNISH AND INSTALL MAX STOP FENCE TO MANUFACTURER

SPECIFICATION. FIELD VERIFY EXISTING CONFIGURATION AND DISTANCES

FOR BIDING AND INSTALLATION .

FURNISH AND INSTALL NEW MULTI-SENSOR CAMERA. VERIFY LOCATION

AND MOUNTING APPLICATIONS/HARDWARE WITH TXDOT PM.

DMARTYNO

Text Box

MON

DMARTYNO

Stamp

DMARTYNO

Text Box

DMARTYNO

Stamp

DMARTYNO

Text Box

DMARTYNO

Oval

DMARTYNO

Rectangle

DMARTYNO

Text Box

DMARTYNO

Text Box

DMARTYNO

Polygon

DMARTYNO

Text Box

DMARTYNO

Text Box

DMARTYNO

Polygon

DMARTYNO

Text Box P

DMARTYNO

Oval

DMARTYNO

Rectangle

DMARTYNO

Rectangle

Rectangle

SOWELL LN. / MALL DR.

Facilities Planning & Management

Date: 7/10/2023

Drawn by: JA/DM

Checked by: JA/DM

No. Description Date

Copyright © 2015 Texas Department of Transportation

Texas Department of Transportation 125 E. 11th Street Austin, Texas 78701-2483

A T

L A

N T

A

D

I S

T R

I C

T

(7

S

TI

ES

FE

N

C

IN

G

S E

C U

R I T

Y

U

P G

R A

D E

T E

X A

R K

A N

A

A

R E

A

E

N G

I N

E E

R

M

A I N

T E

N A

N C

E F

A C

I L I T

Y

S

O W

E L L

A

V E

N U

E

T

E X

A R

K A

N A

T

X

P R

O J E

REV 1

REV 2

REV 3

REV 4

REV 5

REV 6

REV 7

REV 8

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

AutoCAD SHX Text

TX TY 1.0

AutoCAD SHX Text

SITE PLAN

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text P

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text P

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

DMARTYNO

Text Box

GENERAL NOTE:

CONTRACTOR TO INSTALL NEW FIBER FROM MAIN ADMIN BUILDING TO BACK GATE TO RUN CCURE PANEL, TWO CAMERAS AND TWO INTERCOMS.

DMARTYNO

Stamp

DMARTYNO

Text Box NOTE: CONTRACTOR TO VERIFY EXISTING SAFETY LOOPS AND SAFETY DEVICES IN ACCORDANCE WITH CONTRACT DOCUMENTS.

DMARTYNO

Text Box

TX TY 1.0

Facilities & Planning Management

Date: 7/10/2023

Drawn by: JA/DM

Checked by: JA/DM

No. Description Date

Copyright © 2015 Texas Department of Transportation

Texas Department of Transportation 125 E. 11th Street Austin, Texas 78701-2483

A T

L A

N T

A

D

I S

T R

I C

T (7

S

IT

ES

FE

N

C

IN

G

S E

C U

R I T

Y

U

P G

R A

D E

T E

X A

R K

A N

A

A

R E

A

E

N G

I N

E E

I N

T E

N A

N C

E F

A C

I L I T

Y

S

O W

E L L

A

V E

N U

E

T

E X

A R

K A

N A

T

X

P

O J E

REV 1

REV 2

REV 3

REV 4

REV 5

REV 6

REV 7

REV 8

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

GR

PB

GR

AutoCAD SHX Text

%%UCONFERENCE

AutoCAD SHX Text

AutoCAD SHX Text

%%UMAINT CLERK

AutoCAD SHX Text

AutoCAD SHX Text

%%UMAINT FOREMAN

AutoCAD SHX Text

AutoCAD SHX Text

%%URECEPTION

AutoCAD SHX Text

AutoCAD SHX Text

%%URES ENGR OFFICE

AutoCAD SHX Text

AutoCAD SHX Text

%%UDRAFTING

AutoCAD SHX Text

AutoCAD SHX Text

%%UCONFERENCE

AutoCAD SHX Text

AutoCAD SHX Text

%%UMEN

AutoCAD SHX Text

AutoCAD SHX Text

%%UWOMEN

AutoCAD SHX Text

AutoCAD SHX Text

%%UMECH

AutoCAD SHX Text

AutoCAD SHX Text

%%UHALLWAY

AutoCAD SHX Text

AutoCAD SHX Text

TX TY 1.1

AutoCAD SHX Text

ADMIN

AutoCAD SHX Text 6.3

AutoCAD SHX Text

DOR

AutoCAD SHX Text

MON

AutoCAD SHX Text

CR

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 6.3

AutoCAD SHX Text 6.3

AutoCAD SHX Text I

AutoCAD SHX Text

IS

AutoCAD SHX Text 6.3

AutoCAD SHX Text

CR

AutoCAD SHX Text

CR

AutoCAD SHX Text

CR

DMARTYNO

Text Box

NVR

DMARTYNO

Text Box

CAM

DMARTYNO

Text Box

CAM

DMARTYNO

Rectangle

DMARTYNO

Text Box

GENERAL NOTES:

CONTRACTOR TO VERIFY EXISTING (CAMERAS, INTERDOMS, GATE RELEASE BUTTONS,DOOR RELEASE BUTTON & PANIC BUTTON) OPERATIONAL PER CONTRACT DOCUMENTS. CONTRACTOR TO REPAIR AS NECESSARY.

DMARTYNO

Text Box

TX TY 1.1

DMARTYNO

Text Box

EXISTING TO REMAIN

DMARTYNO

Rectangle

DMARTYNO

Text Box

EXISTING TO REMAIN

SUNSET ST.

S.

M cC O

Y

BL

VD

Facilities Planning & Management

Date: 7/10/2023

Drawn by: JA/DM

Checked by: JA/DM

No. Description Date

Copyright © 2015 Texas Department of Transportation

A

TL

A N

TA

D

IS

TR

IC

T

(7 S

IT

ES

FE

N C

IN

G

S

E C

U R

IT

Y

U P

G R

A D

E

N E

W B

O S

TO

N

M A

IN

TE

N A

N C

E F

A C

IL

IT

Y

M cC O

Y B

LV

D

N E

W B

O S

TO

N

, T X

O

JE

C T

REV 1

REV 2

REV 3

REV 4

REV 5

REV 6

REV 7

REV 8

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

DMARTYNO

Text Box

DMARTYNO

Text Box

NB TY 1.0

DMARTYNO

Text Box

GENERAL NOTE:

CONTRACTOR TO VERIFY GATE, DEVICES AND WIRING INSTALLED AND OPERATIONAL. CONTRACTOR TO REPLACE OR REPAIR AS NECESSARY TO BE IN COMPLIANCE WITH CONTRACT DOCUMENTS.

DMARTYNO

Stamp

DMARTYNO

Stamp

DMARTYNO

Text Box

EXISTING PEDESTAL AND BOLLARDS TO REMAIN. REFERENCE GENERAL NOTE THIS SHEET.

DMARTYNO

NB TY 1.1

Drawn by: JA/DM

Checked by: JA/DM

No. Description Date

Copyright © 2015 Texas Department of Transportation

A

TL

A N

TA

D

IS

TR

IC

T

(7 S

IT

ES

FE

N C

IN

G

S

E C

U R

IT

Y

U P

G R

A D

E

N E

W B

O S

TO

N

M A

IN

TE

N A

N C

E F

A C

IL

IT

Y

M cC O

Y B

LV

D

N E

W B

O S

TO

N

, T X

O

JE

C T

REV 1

REV 2

REV 3

REV 4

REV 5

REV 6

REV 7

REV 8

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

GR

PB

S L

IC

Facilities Planning & Management

ADMIN

DMARTYNO

Text Box

NVR

DMARTYNO

Text Box

CAM

DMARTYNO

Text Box

CAM

DMARTYNO

Text Box

IS

DMARTYNO

Text Box

GB

DMARTYNO

Text Box

GENERAL NOTE:

CONTRACTOR TO VERIFY ALL DEVICES AND WIRING INSTALLED AND OPERATIONAL. CONTRACTOR TO REPLACE OR PROVIDE DEVICES AND WIRING AS NECESSARY TO BE IN COMPLIANCE WITH THE CONTRACT DOCUMENTS.

E L S

Y

V E

Facilities Planning & Management

Date: 7/10/2023

Drawn by: JA/DM

Checked by: JA/DM

No. Description Date

Copyright © 2015 Texas Department of Transportation

Texas Department of Transportation 125 E. 11th Street Austin, Texas 78701-2483

A T

L A

N T

A

D

I S

T R

I C

T

(7

S

IT

ES

FE

N

C

IN

G

S E

C U

R I T

Y

U

P G

R A

D

. P L E

A S

A N

T

A

R E

A

E

N G

I N

E E

I N

T E

N A

N C

E F

A C

I L I T

Y

F

E R

G U

S O

N

R

O A

D

M

O U

N

E

A S

A N

T

T

X

O J E

REV 1

REV 2

REV 3

REV 4

REV 5

REV 6

REV 7

REV 8

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

MP TY 1.0

SITE PLAN

AutoCAD SHX Text

MP TY 1.0

AutoCAD SHX Text

SITE PLAN

AutoCAD SHX Text P

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text P

AutoCAD SHX Text

AutoCAD SHX Text

DISTRICT TO FABRICATE ADDITIONAL MOUNT ON PEDESTAL TO ACCOMODATE 2 CARD READERS

AutoCAD SHX Text P

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

DMARTYNO

Text Box

NOTE: REMOVE 20'FT SECTION OF EXISTING FENCE & POSTS.

FOR TXDOT ACCESS TO EMPLOYEE PARKING AREA.

DMARTYNO

Rectangle

DMARTYNO

Line

DMARTYNO

Pencil

DMARTYNO

Pencil

Drawn by: JA/DM

Checked by: JA/DM

No. Description Date

Copyright © 2015 Texas Department of Transportation

Texas Department of Transportation 125 E. 11th Street Austin, Texas 78701-2483

A T

L A

N T

A

D

I S

T R

I C

T

(7

S

IT

ES

FE

N

C

IN

G

S E

C U

R I T

Y

U

P G

R A

T.

P

L E

A S

A N

T

A

R E

A

E

N G

I N

E E

I N

T E

N A

N C

E F

A C

I L I T

Y

F

E R

G U

S O

N

R

O A

D

M

O U

E

A S

A N

T

T

X

O J E

REV 1

REV 2

REV 3

REV 4

REV 5

REV 6

REV 7

REV 8

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

S L

GR

PB

IC

MP TY 1.1

ADMIN

AutoCAD SHX Text

%%UMEETING ROOM

AutoCAD SHX Text

AutoCAD SHX Text

%%UCORRIDOR

AutoCAD SHX Text

AutoCAD SHX Text

%%UWOMEN

AutoCAD SHX Text

AutoCAD SHX Text

%%UMEN

AutoCAD SHX Text

AutoCAD SHX Text

%%UMECH

AutoCAD SHX Text

AutoCAD SHX Text

%%UDRAFTING ROOM

AutoCAD SHX Text

AutoCAD SHX Text

%%UOFFICE

AutoCAD SHX Text

AutoCAD SHX Text

%%UOFFICE

AutoCAD SHX Text

AutoCAD SHX Text

%%URES ENGR

AutoCAD SHX Text

AutoCAD SHX Text

%%URECEPTION

AutoCAD SHX Text

AutoCAD SHX Text

%%UMAINT FOREMAN

AutoCAD SHX Text

AutoCAD SHX Text

%%UMAINT CLERK

AutoCAD SHX Text

AutoCAD SHX Text

MP TY 1.1

AutoCAD SHX Text

ADMIN

AutoCAD SHX Text 6.3

AutoCAD SHX Text

DOR

AutoCAD SHX Text

MON

AutoCAD SHX Text

CR

AutoCAD SHX Text I

AutoCAD SHX Text

IS

AutoCAD SHX Text 6.1

AutoCAD SHX Text

CR

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

DELETED

DMARTYNO

Text Box

NVR

DMARTYNO

Text Box

CAM

DMARTYNO

Text Box

CAM

DMARTYNO

Text Box

IS

DMARTYNO

Text Box

GB

DMARTYNO

Text Box

GENERAL NOTES:

Existing Access Control Headend Panel/Enclosure to remain.

New Life Safety Enclosure, CCure Panel, GCM Boardssupplied by TxDOT.

Existing 120V Power wiring from electrical panel to CCure Panel to remain.

Contractor to Furnish and Install New SWH CCure ACM Board.

Contractor to Furnish and Install New Batteries.

Contractor to Furnish and Install New Termination Clips.

Contractor to Demo Existing Control wiring and dispose.

Facilities Planning& Management

Date:7/10/2023

Drawn by: JA/DM

Checked by: JA/DM

No. Description Date

Copyright © 2015 Texas Department of Transportation

Texas Department of Transportation 125 E. 11th Street Austin, Texas 78701-2483

A T

L A

N T

A

D

I S

T R

I C

T

FE

N

C

IN

G

S E

C U

R I T

Y

U

P G

R A

D E

M T

. P L E

A S

A N

T

A

R E

A

E

N G

I N

E E

I N

T E

N A

N C

E F

A C

I L I T

Y

F

E R

G U

S O

N

R

O A

D

M

O U

E

A S

A N

T

T

X

P R

O J E

REV 1

REV 2

REV 3

REV 4

REV 5

REV 6

REV 7

REV 8

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

S L

S L MP TY 1.2

SHOP / WHSE

AutoCAD SHX Text

%%USHOP AREA

AutoCAD SHX Text

AutoCAD SHX Text

%%ULOCKER

AutoCAD SHX Text

AutoCAD SHX Text

%%USTOCK

AutoCAD SHX Text

AutoCAD SHX Text

%%UOIL RM

AutoCAD SHX Text

AutoCAD SHX Text

%%USTOCK

AutoCAD SHX Text

AutoCAD SHX Text

%%UEQUIPMENT STORAGE

AutoCAD SHX Text

AutoCAD SHX Text

%%UMATERIAL STORAGE

AutoCAD SHX Text

AutoCAD SHX Text

%%ULABORATORY

AutoCAD SHX Text

AutoCAD SHX Text

%%UENGR STO

AutoCAD SHX Text

AutoCAD SHX Text

%%UDUST RM

AutoCAD SHX Text

AutoCAD SHX Text

%%UEQUIPMENT STORAGE

AutoCAD SHX Text

AutoCAD SHX Text

%%UMUD & GREASE TRAP

AutoCAD SHX Text

AutoCAD SHX Text

MP TY 1.2

AutoCAD SHX Text

SHOP/WHSE

AutoCAD SHX Text 6.1

AutoCAD SHX Text

CR

AutoCAD SHX Text 6.1

AutoCAD SHX Text

CR

AutoCAD SHX Text 6.1

AutoCAD SHX Text

CR

AutoCAD SHX Text 6.1

AutoCAD SHX Text

CR

AutoCAD SHX Text 6.1

AutoCAD SHX Text

CR

AutoCAD SHX Text I

AutoCAD SHX Text

IS

AutoCAD SHX Text I

AutoCAD SHX Text I

AutoCAD SHX Text

IS

AutoCAD SHX Text

IS

AutoCAD SHX Text

IS

AutoCAD SHX Text

AutoCAD SHX Text

DMARTYNO

Text Box

IS

DMARTYNO

Text Box

GB

DMARTYNO

Text Box

GENERAL NOTES:

SHOP BUILDING:

Existing Access Control Headend Panel/Enclosure to remain.

New Life Safety Enclosure, CCure Panel, ACM Board supplied by TxDOT.

Existing 120V Power wiring from electrical panel to CCure Panel to remain.

Contractor to Furnish and Install New SWH CCure GCM Board.

Contractor to Furnish and Install New Batteries.

Contractor to Demo Existing Control wiring and dispose.

EQUIPMENT BUILDING:

Existing Access Control Headend Panel/Enclosure to remain.

New Life Safety Enclosure, CCure Panel, ACM & GCM Boards supplied by TxDOT.

Existing 120V Power wiring from electrical panel to CCure Panel to remain.

Contractor to Furnish and Install New Batteries.

Contractor to Demo Existing Control wiring and dispose.

DMARTYNO

Text Box 6.3

DMARTYNO

Text Box 6.3

DMARTYNO

Text Box 6.1

DMARTYNO

Text Box 6.1

DMARTYNO

6.1

U.S. HWY. 259

CO. RD. 4101

Facilities Management

Date: 7/10/2023

Drawn by: JA/DM

Checked by: JA/DM

No. Description Date

Copyright © 2015 Texas Department of Transportation

Texas Department of Transportation 125 E. 11th Street Austin, Texas 78701-2483

A T

L A

N T

A

D

I S

T R

I C

T

(7

S

IT

ES

FE

N

C

IN

G

S E

C U

R I T

Y

U

P G

R A

I N

G E

R F

I E

I N

T E

N A

N C

E

F

A C

I L

I T

Y U

S

O

R T

H

D

A I N

G E

R F

I E

L D

T

X

O

J E

REV 1

REV 2

REV 3

REV 4

REV 5

REV 6

REV 7

REV 8

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

AutoCAD SHX Text P

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text P

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

DFTY 1.0

AutoCAD SHX Text

SITE PLAN

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

DMARTYNO

Text Box

DMARTYNO

Text Box

DF TY 1.0

DMARTYNO

Text Box

DMARTYNO

Text Box

DMARTYNO

Stamp

DMARTYNO

Stamp

DMARTYNO

Text Box

DMARTYNO

Text Box

DMARTYNO

Line

DMARTYNO

Text Box

DMARTYNO

Line

DMARTYNO

Line

DMARTYNO

Line

DMARTYNO

Line

DMARTYNO

Line

DMARTYNO

Line

DMARTYNO

Line

DMARTYNO

Line

DMARTYNO

Line

DMARTYNO

Line

DMARTYNO

Text Box NOTE: DEMO AND DISPOSE OF ALL EXISTING PATHWAYS FROM BUILDING TO GATE OPERATOR TO PEDESTAL AND PATCH ACCORDINGLY.

I

S

L

Facilities Management

Date: 7/10/2023

Drawn by: JA/DM

Checked by: JA/DM

No. Description Date

A T

L A

N T

A

D

I S

T R

I C

T

(7

S

IT

ES

FE

N

C

IN

G

S E

C U

R I T

Y

U

P G

R A

I N

G E

R F

I E

I N

T E

N A

N C

E

F

A C

I L I T

Y U

S

R T

H

D

A I N

G E

R F

I E

L D

T

X

O J E

-4

REV 1

REV 2

REV 3

REV 4

REV 5

REV 6

REV 7

REV 8

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

IS

DF TY 1.1

ADMIN

CR

GR

PB

DOR

MON

3 4

IC

CR

CR

CR

CR

CR

6.3

6.3

6.3

6.3

6.2

CR

6.3

GB

DMARTYNO

Text Box

CR

DMARTYNO

Text Box

NVR

DMARTYNO

Text Box

CAM

DMARTYNO

Text Box

CAM

DMARTYNO

Line

DMARTYNO

Text Box

GENERAL NOTES:

Existing 120V Power wiring from electrical panel to CCure Panel to remain.

U

S

H

W

Y

Facilities Management

Date:7/10/2023

Drawn by:JA/DM

Checked by: JA/DM

No. Description Date

C A

D F

I L E

T

S

S D

F

M P

R O

J E

C T

S S

F

C

I L I T

I E

S A

T L

A

T L S

E C

U R

I T

Y

P

R O

J E

C T

S A

T L A

N T

A

F

Y

S

E C

U R

I T

Y

P

R O

J E

C T

S D

E S

I G

N C

A D

F

Y

G

I L M

E R

G

I L M

T

E

P

L A

N d w g

P l o t t e d

W e d

O c t

A

M

B y c f a r r e l l

Copyright © 2015 Texas Department of Transportation

Texas Department of Transportation 125 E. 11th Street Austin, Texas 78701-2483

A T

L A

N T

A

D

I S

T R

I C

T

(7

S

IT

ES

FE

N

C

IN

G

S E

C U

R I T

Y

U

P G

R A

G

L M

E

A

E

N G

I N

E E

I N

T E

N A

N C

E

F

A C

I L I

U

S

G

I L M

E R

T

X

P R

O J E

-4

REV 1

REV 2

REV 3

REV 4

REV 5

REV 6

REV 7

REV 8

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

AutoCAD SHX Text P

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text P

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

GL TY 1.0

AutoCAD SHX Text

SITE PLAN

AutoCAD SHX Text

AutoCAD SHX Text

DMARTYNO

Text Box

GL TY 1.0

DMARTYNO

Text Box

DMARTYNO

Text Box

DMARTYNO

Text Box

DMARTYNO

Text Box

DMARTYNO

Stamp

DMARTYNO

Stamp

DMARTYNO

Text Box

DMARTYNO

Text Box

DMARTYNO

Text Box

DMARTYNO

Text Box

DMARTYNO

Text Box

DMARTYNO

Text Box

DMARTYNO

Text Box

DEMO AND DISPOSE OF ALL EXISTING PATHWAYS FROM BUILDING TO GATE OPERATOR TO PEDESTAL AND PATCH ACCORDINGLY.

GL TY 1.1

ADMIN

S L

6.3 6.1

6.3 6.1

6.8

I

IS

CR

GR

PB

DOR

MON

CR

CR

CR

CR

CR

IC

Facilities Management

Date: 7/10/2023

Drawn by: JA/DM

Checked by: JA/DM

No. Description Date

Copyright © 2015 Texas Department of Transportation

Texas Department of Transportation 125 E. 11th Street Austin, Texas 78701-2483

A T

L A

N T

A

D

I S

T R

I C

T

(7

S

IT

ES

FE

N

C

IN

G

S E

C U

R I T

Y

U

P G

R A

L

M E

R

A

R E

A

E

N G

I N

E E

I N

T E

N A

N C

E

F

A C

I L

I

L

M E

R

T

X

P R

O J E

-4

REV 1

REV 2

REV 3

REV 4

REV 5

REV 6

REV 7

REV 8

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

3 4

GB6.3

DMARTYNO

Text Box

DMARTYNO

Line

DMARTYNO

Line

DMARTYNO

Text Box

NVR

DMARTYNO

Text Box

CAM

DMARTYNO

Text Box

CAM

DMARTYNO

Text Box

GENERAL NOTES:

Existing Access Control Headend Panel/Enclosure to remain.

New Life Safety Enclosure, CCure Panel, ACM & GCM Boards supplied by TxDOT.

Existing 120V Power wiring from electrical panel to CCure Panel to remain.

Contractor to Furnish and Install New Batteries.

Contractor to Furnish and Instal New Termination Clips.

GL TY 1.2

SHOP

Facilities Management

Date: 7/10/2023

Drawn by: JA/DM

Checked by: JA/DM

No. Description Date

Copyright © 2015 Texas Department of Transportation

Texas Department of Transportation 125 E. 11th Street Austin, Texas 78701-2483

A T

L A

N T

A

D

I S

T R

I C

T

(7

S

IT

ES

FE

N

C

IN

G

S E

C U

R I T

Y

U

P G

R A

D E

G I L M

E

A

E

N G

I N

E E

I N

T E

N A

N C

E

F

A C

I L I

U

S

G

I L M

E R

T

X

P R

O J E

REV 1

REV 2

REV 3

REV 4

REV 5

REV 6

REV 7

REV 8

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

6.3

CRCR CR

6.1 6.11

S L

IS

GB

Date:7/10/2023 Drawn by: JA/DM

Checked by: JA/DM

No. Description Date

Copyright © 2015 Texas Department of Transportation

Texas Department of Transportation 125 E. 11th Street Austin, Texas 78701-2483

A T

L A

N T

A

D

I S

T R

I C

T

(7

S

IT

ES

FE

N

C

IN

G

S E

C U

R I T

Y

U

P G

R A

D E

M A

R S

H A

E

A

E

N G

I N

E E

I N

T E

N A

N C

E

F

A C

I L

I

E

L

O O

P

R

H

R

S H

A L

L

T

X

P R

O J E

REV 1

REV 2

REV 3

REV 4

REV 5

REV 6

REV 7

REV 8

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

MR TY 1.0

SITE PLAN

AutoCAD SHX Text

MR TY 1.0

AutoCAD SHX Text

SITE PLAN

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text P

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text P

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

DMARTYNO

Text Box

DMARTYNO

Text Box

DMARTYNO

Text Box

DMARTYNO

Text Box

DMARTYNO

Text Box

DMARTYNO

Line

DMARTYNO

Line

DMARTYNO

Text Box NOTE: PERSONNEL GATE TO REMAIN, CONTRATOR TO MODIFY AND ADJUST. CONTRACTOR TO PROVIDE NEW HARDWARE.

DMARTYNO

Text Box

DMARTYNO

Line

DMARTYNO

Text Box

DMARTYNO

Text Box

GENERAL NOTE:

DEMO AND DISPOSE OF ALL EXISTING PATHWAYS FROM BUILDING TO GATE OPERATOR TO PEDESTAL AND PATCH ACCORDINGLY.

DMARTYNO

Rectangle

DMARTYNO

Line

Stamp

MR TY 1.1

ADMIN

Facilities Planning & Management

Date: 7/10/2023

Drawn by: JA/DM

Checked by: JA/DM

No. Description Date

Copyright © 2015 Texas Department of Transportation

Texas Department of Transportation 125 E. 11th Street Austin, Texas 78701-2483

A T

L A

N T

A

D

I S

T R

I C

T

(7

S

IT

ES

FE

N

C

IN

G

S E

C U

R I T

Y

U

P G

R A

D E

M A

R S

H A

L L

A

R E

A

E

N G

I N

E E

I N

T E

N A

N C

E

F

A C

I L I

E

L O

N

O R

R

S H

A L L

T

X

O

J E

REV 1

REV 2

REV 3

REV 4

REV 5

REV 6

REV 7

REV 8

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

3 4

GR

PB

DOR

MON

S L

CR

IC

I

IS

CR

CR

CR

GB

AutoCAD SHX Text 6.3

AutoCAD SHX Text 6.1

AutoCAD SHX Text 6.1

AutoCAD SHX Text 6.1

DMARTYNO

Text Box

NVR

DMARTYNO

Text Box

CAM

DMARTYNO

Text Box

CAM

DMARTYNO

Text Box

GENERAL NOTES:

Existing Access Control Headend Panel/Enclosure to remain.

New Life Safety Enclosure, CCure Panel, ACM & GCM Boards supplied by TxDOT.

Existing 120V Power wiring from electrical panel to CCure Panel to remain.

Contractor to Furnish and Install New Batteries.

MR TY 1.2

SHOP

Facilities Planning & Management

Date: 7/10/2023

Drawn by: JA/DM

Checked by: JA/DM

No. Description Date

Copyright © 2015 Texas Department of Transportation

Texas Department of Transportation 125 E. 11th Street Austin, Texas 78701-2483

A T

L A

N T

A

D

I S

T R

I C

T (7

S

IT

ES

FE

N

C

IN

G

S E

C U

R I T

Y

U

P G

R A

D E

M A

R S

H A

L L

A

R E

A

E

N G

I N

E E

I N

T E

N A

N C

E

F

A C

I L I

E

L O

N

O R

R

S H

A L L

T

X

O

J E

REV 1

REV 2

REV 3

REV 4

REV 5

REV 6

REV 7

REV 8

/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

S L

CR

CR

CR

CR

CR CR

I

IS

CR

GB

AutoCAD SHX Text 6.1

AutoCAD SHX Text 6.8

AutoCAD SHX Text 6.1

AutoCAD SHX Text 6.1

AutoCAD SHX Text 6.1

AutoCAD SHX Text 6.1

AutoCAD SHX Text 6.1

DMARTYNO

Text Box

GENERAL NOTES:

Existing Access Control Headend Panel/Enclosure to remain.

New Life Safety Enclosure, CCure Panel, ACM & GCM Boards supplied by TxDOT.

Existing 120V Power wiring from electrical panel to CCure Panel to remain.

Contractor to Furnish and Install New Batteries.

Contractor to Furnish and Install New Termination Clips.

Contractor to Demo Existing Control wiring and dispose.

DMARTYNO

Text Box 6.3

DMARTYNO

Text Box 6.3

DMARTYNO

Text Box 6.3

DMARTYNO

Text Box 6.3

DMARTYNO

Text Box 6.1

DMARTYNO

Text Box 6.8

DMARTYNO

6.1

MR TY 1.3

STORAGE

CR

I

IS

S L

Facilities Planning & Management

Date: 7/10/2023

Drawn by: JA/DM

Checked by: JA/DM

No. Description Date

Copyright © 2015 Texas Department of Transportation

Texas Department of Transportation 125 E. 11th Street Austin, Texas 78701-2483

A T

L A

N T

A

D

I S

T R

I C

T

(7

S

IT

ES

FE

N

C

IN

G

S E

C U

R I T

Y

U

P G

R A

D E

M A

R S

H A

E

A

E

N G

I N

E E

I N

T E

N A

N C

E

F

A C

I L

I

E

L

O O

P

R

R

S H

A L

L

T

X

O

J E

REV 1

REV 2

REV 3

REV 4

REV 5

REV 6

REV 7

REV 8

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

GB

AutoCAD SHX Text 6.1

DMARTYNO

Text Box

GENERAL NOTES:

Existing Access Control Headend Panel/Enclosure to remain.

New Life Safety Enclosure, CCure Panel, ACM Board supplied by TxDOT.

Existing 120V Power wiring from electrical panel to CCure Panel to remain.

Contractor to Furnish and Install Additional SWH CCure GCM Board and Power Supplies.

Contractor to Furnish and Install New Batteries.

Contractor to Furnish and Install New Termination Clips.

Contractor to Demo Existing Control wiring and dispose.

DMARTYNO

Line

DMARTYNO

Line

DMARTYNO

Text Box NOTE: CONTRACTOR TO INSTALL CONDUIT PATHWAY AND CABLING FROM STORAGE BUILDING CCURE PANEL TO SHOP BUILDING TO SWITCH FOR NETWORK.

Drawn by: JA/DM

Checked by: JA/DM

No. Description Date

Copyright © 2015 Texas Department of Transportation

Texas Department of Transportation 125 E. 11th Street Austin, Texas 78701-2483

A T

L A

N T

A

D

I S

T R

I C

T

(7

S

IT

ES

FE

N

C

IN

G

S E

C U

R I T

Y

U

P G

R A

N

D E

N

M

A I N

T E

N A

N C

E

F

A C

I L I T

Y

S

T A

W

I N

D E

N

T

X

P R

O J E

REV 1

REV 2

REV 3

REV 4

REV 5

REV 6

REV 7

REV 8

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

LN TY 1.0

SITE PLAN

AutoCAD SHX Text

ADMIN BUILDING

AutoCAD SHX Text

LN TY 1.0

AutoCAD SHX Text

SITE PLAN

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text P

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text P

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

MAN GATE

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

MOVE GATE BACK TO THE END OF BUILDING

AutoCAD SHX Text

AutoCAD SHX Text

DMARTYNO

Line

DMARTYNO

Text Box

DMARTYNO

Line

DMARTYNO

Line

DMARTYNO

Line

DMARTYNO

Pencil

DMARTYNO

Line

DMARTYNO

Text Box

DMARTYNO

Text Box

DMARTYNO

Text Box

DMARTYNO

Text Box

NOTE: DEMO EXISTING CONCRETE TROUGH

DMARTYNO

Text Box

DEMO AND DISPOSE OF ALL EXISTING PATHWAYS FROM BUILDING TO GATE OPERATOR TO PEDESTAL AND PATCH ACCORDINGLY.

Drawn by: JA/DM

Checked by: JA/DM

No. Description Date

Copyright © 2015 Texas Department of Transportation

Texas Department of Transportation 125 E. 11th Street Austin, Texas 78701-2483

A T

L A

N T

A

D

I S

T R

I C

T

(7

S

IT

ES

FE

N

C

IN

G

S E

C U

R I T

Y

U

P G

R A

LI

D E

N

M

A I N

T E

N A

N C

E

F

A C

I L

I T

Y

S

T A

W

N

D E

N

T

X

P R

O J E

REV 1

REV 2

REV 3

REV 4

REV 5

REV 6

REV 7

REV 8

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

S L

GR

PB

IC

LN TY 1.1

ADMIN

IS

GB

NVR

AutoCAD SHX Text

EQUIPMENT

AutoCAD SHX Text %%uSTORAGE

AutoCAD SHX Text

AutoCAD SHX Text %%uTOOL STORAGE

AutoCAD SHX Text

AutoCAD SHX Text %%uMATERIAL STORAGE

AutoCAD SHX Text

AutoCAD SHX Text %%uEQUIPMENT STORAGE

AutoCAD SHX Text

AutoCAD SHX Text %%uWASH

AutoCAD SHX Text

AutoCAD SHX Text %%uSHOP

AutoCAD SHX Text

AutoCAD SHX Text %%uLOCKER

AutoCAD SHX Text

AutoCAD SHX Text %%uSTOCK

AutoCAD SHX Text

AutoCAD SHX Text %%uRECEPT

AutoCAD SHX Text

AutoCAD SHX Text %%uOFFICE

AutoCAD SHX Text

AutoCAD SHX Text %%uOFFICE

AutoCAD SHX Text

AutoCAD SHX Text %%uVEST

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text %%uMEETING

AutoCAD SHX Text

AutoCAD SHX Text

LN TY 1.1

AutoCAD SHX Text

ADMIN

AutoCAD SHX Text 6.2

AutoCAD SHX Text 6.2

AutoCAD SHX Text 6.2

AutoCAD SHX Text 6.1

AutoCAD SHX Text 6.1

AutoCAD SHX Text 6.3

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

DOR

AutoCAD SHX Text

MON

AutoCAD SHX Text

AutoCAD SHX Text I

AutoCAD SHX Text

AutoCAD SHX Text

IS

AutoCAD SHX Text

IS

AutoCAD SHX Text

IS

AutoCAD SHX Text

CR

AutoCAD SHX Text

CR

AutoCAD SHX Text

CR

AutoCAD SHX Text

CR

AutoCAD SHX Text

CR

AutoCAD SHX Text

CR

DMARTYNO

Line

DMARTYNO

Line

DMARTYNO

Line

DMARTYNO

Text Box

CAM

DMARTYNO

Text Box

CAM

DMARTYNO

Line

DMARTYNO

Rectangle

DMARTYNO

Text Box

GENERAL NOTES:

Existing Access Control Headend Panel/Enclosure to remain.

New Life Safety Enclosure, CCure Panel, ACM & GCM Boards supplied by TxDOT.

Existing 120V Power wiring from electrical panel to CCure Panel to remain.

Contractor to Furnish and Install Additional SWH CCure ACM Board.

Contractor to Furnish and Install New Batteries.

GATE POST

CATCH

LATCH

EQUAL GATE PANELS

2.375" O.D. TOP &

BOTTOM. MEMBERS

DIAG. MEMBERS

2 1/2" O.D. SAFETY POST

4" GATE POST 4" GATE POST

GATE FRAME MEMBERS

GATE POST GATE POST

FENCE POST

ELEVATION

PLAN VIEW

TRACK AND

ROLLER ASSEMBLY

AT TOP AND

BOTTOM OF GATE.

TRACK & ROLLER

TOP ROLLERBARBED WIRE

ELEVATION ELEVATION

PLANPLAN

FABRIC & BOTTOM

STRETCHER

FABRIC &

4 GATE SECTION

SCALE: N.T.S.5 ASSEMBLY

SCALE: N.T.S.

6 ASSEMBLY

SCALE: N.T.S.

7 END POST DETAIL

SCALE: N.T.S.

8 GATE SECTION

SCALE: N.T.S

SCALE:9 END POST

N. T. S.

SCALE:10 END POST

N. T. S.

SCALE:11 BRACE RAIL

N. T. S.SCALE:14 TOP RAIL

N. T. S.

SCALE:13 LINE POST

N. T. S.

SCALE:12 LINE POST

N. T. S.

SCALE:15 TENSON WIRE

N. T. S.

SCALE:16 BAR BAND

N. T. S.

SCALE:17 TOP RAIL

N. T. S.

CORNER OR

FENCE/GATE DETAILS

CHAIN LINK & CANTILEVER

TY5.1SCALE:1 STANDARD CANTILEVER SLIDING GATE.

NTS

GATE TO HAVE 1 58" STIFFENER RAIL ADDED ON INTERNAL

SIDE OF FENCE. RUNNING THE ENTIRE LENGTH OF GATE

PER UL 325 CODE GATE -FABRIC ENTIRE LENGTH OF GATE

Facilities Management

Date 7 10 3

Drawn by

Checked by

No. Description Date

Copyright © 2015 Texas Department of Transportation

REV 1

REV 2

REV 3

REV 4

REV 5

REV 6

REV 7

REV 8

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

6230 STASSNEY LANE

AUSTIN, TEXAS 75744

SITE SECURITYSYSTEM

UPGRADE AND

INSTALLATION PROJECT

TE

XA

S D

EP

AR

TM

EN

T O

F

TR

AN

SP

O R

TA

TI

O N

SE

C

U R

IT

Y

SY

ST

EM

S

U

PG

R

AD

E

TY 5.1 8

/ T

Y 5.

/ T

Y 5.

TY

.1

TY

.1

GENERAL NOTE:

INSTALL PLUGS AT OPEN PIPE ENDS;

GATE, FENCE & PEDESTALS. (TYPICAL)

ALL POSTS

SEE 16 / TY 5.1

6 / TY 5.1

INSTALL FENCE POSTS

EQUALLY SPACED

INSTALL FENCE POSTS

EQUALLY SPACED

DMARTYNO

Rectangle

DMARTYNO

Line

DMARTYNO

Text Box

REFERENCE

DETAIL 2 / TY5.1

DMARTYNO

Text Box Bottom of Rail

DMARTYNO

Line

DMARTYNO

Text Box

DMARTYNO

Text Box 5"max.

DMARTYNO

Text Box

FENCE, POST AND FOOTINGS DETAIL

DMARTYNO

Text Box

DMARTYNO

Line

DMARTYNO

Oval

DMARTYNO

Text Box

DMARTYNO

Text Box

DETAIL 17 / TY5.1

DMARTYNO

Text Box

THIS DRAWING CREATED FOR PRODUCTION ON 22"x34" SHEET SIZE. DO NOT SCALE PRINTS.

COPYRIGHT 2021c

P R

O

JE

C T

N O

-1

9-

-0

T

X

C O

U N

T Y

T Y

LE

R

D

IS

T R

IC

T

ISSUED: 12/0 /2022

DRAWN BY:

CHECKED BY:

REVISIONS:

N O

R

TH

T

YL

ER

M

N T

FA

C

IL

IT

Y

- F

EN

C

IN

G

G

A

TE

S

N or th

N or th ea st L oo p

3, T

YL

ER

, T

X

SM

IT

H C

O U

TY

TY

LE

R

D

IS

TR

IC

T

- 1

PR

O

JE

C T

N O

. 1 0-

-2 3-

DMARTYNO

Text Box

SCALE: N.T.S

DMARTYNO

Text Box

SCALE: N.T.S

DMARTYNO

Text Box

SCALE: N.T.S

DMARTYNO

Text Box

SCALE: N.T.S.

DMARTYNO

Text Box

3 / TY5.5

DMARTYNO

Text Box

4 / TY5.5

DMARTYNO

Text Box

DETAIL 7 / TY5.5

DMARTYNO

SCALE: N.T.S.

(2) 1'-0" LONG #5 STEEL

REINFORCING THROUGH

PIPE BOLLARD

CONCRETE FOOTING

2" JOINT WITH

COMPRESSIBLE

JOINT FILLER.

ASPHALT PAVEMENT

(VERIFY SURFACE FINISHING)

1'

4"4"

3" DIA. HOT DIP GAL.

STEEL PIPE BOLLARD

FILLED WITH CONCRETE.

COORDINATE LOCATION

OF GATE OPEARTORS

POST WITH G1 AND G2

4' -0

2'

6"

3 GATE OPERATOR POST DETAIL

SCALE: N.T.S.

2 GATE OPERATOR & ACCESS CONTROL ENCLOSURE DETAIL

SCALE: N.T.S.

3R

NEMA 3R DISCONNECT

MOUNTED ON GATE

OPERATOR CABINET

LIFTMASTER INSL24UL OR IHSL24UL

GATE OPERATOR 120 1 PROVIDE

OPTIONAL HEATER AND GROUNDED

DUPLEX OUTLET

OPERATOR POSTS

SEE DETAIL 3/TY5.6

INSTALL ACCESS CONTROL ENCLOSURE

(PART NO. HOFFMAN WF3LP) EITHER SIDE BY

SIDE (SHOWN) OR STACKED TOP & BOTTOM

(NOT SHOWN). COORDINATE WITH TXDOT PM.

INSTALL ALL ACCESS, CAMERA, INTERCOM

EQUIPMENT (CCURE EDGE PANEL, CCTV AND

GATE READER POWER SUPPLIES, FIBER,

NETWORK JUNCTIONS) INSIDE ACCESS

CONTROL ENCLOSURE.

PROVIDE UNISTRUT CROSS BRACE TO

SUPPORT CONDUITS.

0-373'

GATE OPERATOR

WIRING SCHEDULE

#10

3R

UGE UGE UGE UGE UGE UGE UGE

UVD UVD UVD UVD UVD UVD UVD UVD UVD

UVD UVD UVD UVD

U V

D

TXDOT

NETWORK

SWITCH

POWER

PANEL

BLDG.

PROVIDE SEPERATE PULL BOXES FOR

POWER AND COMMUNICATION SPACED

NOT TO EXCEED BOXES EVERY 150'

1 GATE OPERATOR AND PEDESTAL RISER

SCALE: N.T.S.

374'-537' #8

538'-852' #6

UVD UVD UVD UVD

U V

D

2" PVC w/ DIRECT BURRIAL CABLE

1-1/4" PVC

TRANSITION TO EMT INSIDE BUILDING

TRANSITION TO PLENUM RATED

CABLE OR 2" EMT INSIDE BUILDING

J

J

STUB UP RMC INTO LB. TRANSITION TO

EMT FOR WALL PENETRATION.

SEAL CONDUIT PENTRATIONS.

1-1/4" PVC 2" PVC w/ DIRECT BURRIAL CABLE GATE OPERATOR

DETAILS

TY5.6

SITE SECURITY SYSTEM

UPGRADE AND

INSTALLATION PROJECT

Facilities Management

Scale

Date 7 10 3

Drawn by

Checked by

No. Description Date

Copyright © 2015 Texas Department of Transportation

REV 1

REV 2

REV 3

REV 4

REV 5

REV 6

REV 7

REV 8

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

6230 STASSNEY LANE

AUSTIN, TEXAS 75744

TE

XA

S D

EP

AR

TM

EN

T O

F

TR

AN

SP

O R

TA

TI

O N

SE

C

U R

IT

Y

SY

ST

EM

S

U

PG

R

AD

E

ACCESS

CONTROL

ENCLOSURE

LIFT MASTER GATE OPERATOR AND

CCURE (HOFFMAN) ENCLOSURE

JALEXAND

Text Box TxDOT no longer allows any non-TxDOT switches, either stand-alone or connected to TxDOT network.

All outdoor field devices (iStar Edge, cameras, intercoms) shall connect directly to TxDOT switch inside the building. Security contractor shall provide an access control equipment enclosure adjacent to (and connected to) the gate controller enclosure. This ACS enclosure will house: Ccure iStar Edge and power supply, Network drops from building, POE injectors (if needed), fiber equipment (if needed), patch cables to pedestal. NVR shall connect to TxDOT switch for recording. HDMI cable shall not be attached to NVR to provide video to monitor. Video decoder shall connect to TxDOT switch to provide video to monitor.

DMARTYNO

Text Box

COORDINATE LOCATION OF GATE OPERATOR POSTS PER MANUFACTURER REQUIREMENTS

DMARTYNO

Line

DMARTYNO

Line

DMARTYNO

Text Box

DMARTYNO

Text Box

DMARTYNO

Text Box

DMARTYNO

Text Box

DMARTYNO

Line

DMARTYNO

Line

OPTION - A OPTION - B

OPTION - C

PEDESTAL NOTES

FURNISH AND INSTALL, OUTDOOR MINI DOME CAMERAS.

FURNISH AND INSTALL LONG RANGE PROXIMITY CARD READERS. FURNISH

AND MOUNT CARD READERS TO ACRYLIC PLATE WITH NYLON BOLTS.

FURNISH AND INSTALL INTERCOMS. FURNISH AND MOUNT INTERCOMS TO

ACRYLIC PLATE WITH NYLON BOLTS

INSTALL TXDOT PROVIDED CARD READER PEDESTAL.

INSTALL TXDOT PROVIDE PEDESTAL BASE.

FURNISH NYLON BOLTS, WASHERS AND NUTS MOUNT ACRYLIC PLATE TO

BACK BOX

FURNISH AND INSTALL KNOX BOX MODEL 3502 KEY SWITCH, COORDINATE

KEYING WITH LOCAL AHJ. COORDINATE MOUNTING DIRECTION WITH TXDOT

REPRESENATIVE

PEDESTAL DETAIL

TY5.7

SITE SECURITY SYSTEM

UPGRADE AND

INSTALLATION PROJECT

Facilities Management

Date: 7/10/2023

Drawn by: JA/DM

Checked by JA/DM

No. Description Date

C A

D F

I L

E

T

S

S D

F

M

P R

O J E

C T

S

C A

D

S E

C U

R I T

Y

S

H E

E T

S T

Y

T

Y

T

Y

T

Y

T

E

O

P

R

I S

E R

P

E D

E S

T A

L

D

E T

A I L

S

P

E D

E S

T A

L

B

A S

E d w g l o t t e d

S a t

M a r

A

M

B y

C

F A

R R

E L

L

Copyright © 2015 Texas Department of Transportation

Texas Department of Transportation 125 E. 11th Street Austin, Texas 78701-2483

T E

X A

S

D

E P

A R

T M

E N

T

O

F

T

R A

N S

P O

R T

A T

I O

N

S E

C U

R I T

Y

S

Y S

T E

G

R A

D E

REV 1

REV 2

REV 3

REV 4

REV 5

REV 6

REV 7

REV 8

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

FURNISH AND INSTALL PEDESTAL GROUNDING, 5/8"X7' COPPERWELD

GROUND ROD CONNECT TO PEDESTAL GROUND WIRE AD GROUNDLUG IN

BASE. BURNDY COPPER #KPA4C SCRULUG AND TIN PLATED NUT AND

BOLT OR BURNDY COPPER #KC20 SERVIT ATTACHED TO GROUNDING LUG

#4 GROUND CABLE ATTACHED TO GROUND ROD.

DMARTYNO

Text Box

CAP OFF ALL OPEN HOLES

DMARTYNO

Text Box

DMARTYNO

Text Box

DMARTYNO

Line

DMARTYNO

Line

DMARTYNO

Line

DMARTYNO

Line

DMARTYNO

Line

DMARTYNO

Line

DMARTYNO

Text Box

DMARTYNO

Line

DMARTYNO

Line

DMARTYNO

Line

DMARTYNO

Rectangle

DMARTYNO

Text Box

OPTION C

CONTRATOR TO CUT OFF TOP OF TXDOT SUPPLIED PEDESTAL AND CAP

DMARTYNO

Line

DMARTYNO

Line

DMARTYNO

Line

DMARTYNO

Rectangle

DMARTYNO

Line

PEDESTAL BASE

DETAIL

TY5.8

SITE SECURITY SYSTEM

UPGRADE AND

INSTALLATION PROJECT

Support Services Division Facilities Planning & Management

Date: 07/10/2023

Drawn by: JA/DM

Checked by: JA/DM

No. Description Date

Copyright © 2015 Texas Department of Transportation

REV 1

REV 2

REV 3

REV 4

REV 5

REV 6

REV 7

REV 8

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

4', 5', 6'

6230 STASSNEY LANE

AUSTIN, TEXAS 75744

TE

XA

S D

EP

AR

TM

EN

T O

F

TR

AN

SP

O R

TA

TI

O N

SE

C

U R

IT

Y

SY

ST

EM

S

U

PG

R

AD

E

SCALE:

ELECTRICAL-VOICE DATA PAVED AREAS TYPICAL1 NOT TO SCALE

REPAIR ALL ASPHALT AND/OR CONCRETE

EXISTING GRADE

CONCRETE 3000 P.S.I. COMPRESSIVE

STRENGTH REQUIRED FOR FEEDERS.

SLOPE TRENCH WALLS OR SHORING AS

REQUIRED PER SPECIFICATIONS. SHORING

SHALL BE USED WHERE NECESSARY TO

STAY WITHIN CLEARING LIMITS.

PIPING AS SPECIFIED DIAMETER

PER PLAN (NOTE: PIPING BURIED IN

THE SAME TRENCH SHALL BE 4"

APART MINIMUM). PIPING TO BE SCH 80

IN PAVED AREAS

EXCAVATED MATERIAL COMPACTED

TO AT LEAST EXISTING DENSITY, OR

96% PROCTOR, WHICHEVER IS GREATER.

YELLOW WARNING TAPE WITHIN

12" OF TOP OF TRENCH24

" M

IN

3" 3"

3" D 3"

SCALE:

ELECTRICAL-VOICE DATA UNPAVED AREAS TYPICAL2 NOT TO SCALE

" M

IN

D3"

3" 3"

YELLOW WARNING TAPE WITHIN

12" OF TOP OF TRENCH

GRANULAR PIPE EMBEDMENT ("SAND")

AS DEFINED BY ASTM C-33.

PIPING AS SPECIFIED DIAMETER

PER PLAN (NOTE: PIPING BURIED IN

THE SAME TRENCH SHALL BE 4"

APART MINIMUM). PIPING TO BE SCH

40 IN UNPAVED AREAS

EXCAVATED MATERIAL COMPACTED

TO AT LEAST EXISTING DENSITY, OR

96% PROCTOR, WHICHEVER IS GREATER.

3"

SLOPE TRENCH WALLS OR SHORING AS

REQUIRED PER SPECIFICATIONS. SHORING

SHALL BE USED WHERE NECESSARY TO

STAY WITHIN CLEARING LIMITS.

MOUND

EXISTING GRADE

SCALE:

QUAZITE 11"X 18" BOX W/INTEGRAL BOTTOM4 NOT TO SCALE. OR TXDOT APPROVED EQUAL

(2) 1'-0" LONG #5 STEEL

REINFORCING THROUGH

PIPE BOLLARD

CONCRETE FOOTING

2" JOINT WITH

COMPRESSIBLE

JOINT FILLER.

ASPHALT PAVEMENT

(VERIFY SURFACE FINISHING)

24"

8"8"

8" DIA. HOT DIP GAL.

STEEL PIPE BOLLARD

FILLED WITH CONCRETE.

4' -0

3'

-0

6"

SCALE:3 BOLLARD DETAIL

NONE

FOR 15,000 LBS. & COVER RATED FOR 8,000 LBS.

NEW UNDERGROUND PULLBOX FOR BELOW GRADE SERVICE,

POLYMER/CONCRETE TYPE EQUAL TO QUAZITE #PG SERIES

W/ COVER "ELECTRIC". BOX LOAD RATED

SCALE:

GROUND BOX5 NOT TO SCALE

32"

CONDUITS WI COUPLING

RMC CONDUITS 3" ABOVE

PEA GRAVEL BEDDING,

MINIMUM 3" DEEP, STUB

18"

19 7/8"

GRAVEL BED

TERMINATE ALL NEW

23"

NEW SCH ## CONDUITS

13"

36"

TY5.9

SITE SECURITY SYSTEM

UPGRADE AND

INSTALLATION PROJECT

Facilities Management

Date 7 10 3

Drawn by

Checked by

No. Description Date

Copyright © 2015 Texas Department of Transportation

TE

X

A S

D E

P A

R

TM

E N

T O

F

TR

A N

S P

O R

TA

TI

O N

S E

C U

R

IT

Y S

Y S

TE

M

S U

P G

R A

D E

REV 1

REV 2

REV 3

REV 4

REV 5

REV 6

REV 7

REV 8

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

6" 6"

BOLLARD & PEDESTAL DETAIL

NOT TO SCALE

1/2-IN Joint w/ Compressible Filler (Only when cast against concrete)

Finish Grade Surface

(4)pcs. 12-IN long #5 Reinforcing Steel installed perpendicular through pipe bollard. (Typical at Top & Bottom.)

Top of Pedestal Shaft may vary pending existing grade.

Shaft Height 4', 5' or 6' *Pending penetrometer soil reading, reference table sheet TY5.8

4'-0"

3'-0"

2'-0"

3"

1'-6"

6230 STASSNEY LANE

AUSTIN, TEXAS 75744

TE

XA

S D

EP

AR

TM

EN

T O

F

TR

AN

SP

O R

TA

TI

O N

AT

LA

N

TA

D

IS

TR

IC

T

SE

C U

R

IT

Y

SY

ST

EM

U

PG

R

AD

E

DMARTYNO

Text Box

DMARTYNO

Text Box

DMARTYNO

Rectangle

DMARTYNO

Line

DMARTYNO

Line

DMARTYNO

Line

DMARTYNO

Text Box 26 1/2" CL Pedestal to CL to Bollards

DMARTYNO

Line

DMARTYNO

Rectangle

DMARTYNO

Line

DMARTYNO

Line

DMARTYNO

Text Box PROVIDE HIGH DENSITY POLYETHYLENE BOLLARD COVER, GRAINGER #32NC72 OR APPROVED EQUAL

DMARTYNO

Text Box 6" DIA. HOT DIP GAL. STEEL PIPE BOLLARDS FILLED WITH 3000 PSI CONCRETE, DOME CONCRETE TOP OF BOLLARD. FIELD VERIFY BOLLARD LOCATION WITH TXDOT PM

DMARTYNO

Text Box

4'-0" FROM FINISH GRADE TO TOP OF BOLLARD AND CENTERLINE OF CARD READER

DMARTYNO

Line

DMARTYNO

Line

2' -6

SECURITY

FENCE

SLOPE

CONCRETE 1/8"

PER FOOT TO

DRAIN

1' -6

6"

6"

2/TY5.10

2'-0"

CONCRETE

CURB REFER TO

SITE PLAN

CONCRETE

CURBS

3/

TY

5.

CONCRETE

OR ASPHALT

PAVING

GATE SUPPORT POST,

FIELD VERIFY

LOCATION - TYPICAL

FIELD VERIFY

STARTING POINT

OF TROUGH -

TYPICAL

SECURITY

FENCE

FENCE

CANTILEVERED GATE

GATE SUPPORT POST

GRADE VARIES

CONCRETE

TROUGH

6" 6"

VA

RI

ES

" M

IN

.-F

IE

LD

V

ER

IF

Y

6" (T

YP

#4 DOWELS @ 12" O.C.

(TYP.)

COMPACTED SELECT

FILL (TYP.)

GRADE VARIES (TYP.)

2'-6"

1'-6"

#3 DOWELS @ 12" O.C.

(TYP.)

2"

1' -0

6"

VA

RI

ES

6" (T

YP

#3 DOWELS @ 12" O.C.

(TYP.)

COMPACTED SELECT

FILL (TYP.)

GRADE VARIES (TYP.)

VARIES

SLOPE

CONCRETE 1/8"

PER FOOT TO

DRAIN

#4 DOWELS @ 12" O.C.

(TYP.)

2"

CANTILIVER GATE CONCRETE TROUGH DETAILS

TY5.10

4 CANT L ERED GATE ASSEMBLY

SCALE: N.T.S.3 STEEL REINFORCING

SCALE: N.T.S.2 STEEL REINFORCING

SCALE: N.T.S.

1 PLAN VIEW OF CONCRETE TROUGH

SCALE: N.T.S.

Facilities Management

Date 7 10 3

Drawn by

Checked by

No. Description Date

Copyright © 2015 Texas Department of Transportation

REV 1

REV 2

REV 3

REV 4

REV 5

REV 6

REV 7

REV 8

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

XX/XX/XXXX

TROUGH

6230 STASSNEY LANE

AUSTIN, TEXAS 75744

SITE SECURITYSYSTEM

UPGRADE AND

INSTALLATION PROJECT

TE

XA

S D

EP

AR

TM

EN

T O

F

TR

AN

SP

O R

TA

TI

EC

U

R

IT

Y

SY

ST

EM

S U

PG

R

AD

E

DMARTYNO

Text Box

GATE POSTS INSTALLED WITHIN TROUGH.

DMARTYNO

NOTE: TROUGH DETAIL TYPICAL FOR ORNAMENTAL OR CHAINLINK CANTILEVER GATES

UPPER GUIDE ASSEMBLY. REF. DETAIL 3

FI

EL

D

VE

RI

RY

2' -0

2' -0

GRASS AREA

FIELD VERIFY

FIELD VERIFY FIELD VERIFY

ASPHALT

PAVING

FIELD VERIFY

V-GROOVE

TRACK

V-GROOVE TRACK

12" THICK CONC. PAD @ GATE AREA

TYPE F CONCRETE (4200 psi) REINFORCING #4 @ 4 " O.C.

CONCRETE CURBS

FIELD VERIFY

OUTSIDE

SECURED SIDE

SECURITY

FENCE

SLIDING GATE

5/

TY

5.

VARIES GATE

GATE OPERATOR

REFER TO TY5.6

SECURITY

FENCE

SLIDING GATE

POST (TYP)

FIELD VERIFY FIELD VERIFY

CONC. CURB AND GUTTER

FIELD VERIFY

FI

EL

D

VE

RI

FY

CONC. CURB AND

GUTTER FIELD VERIFY

CONC. CURB AND

GUTTER FIELD VERIFY

6/

TY

5.

11GRASS AREA

FIELD VERIFY

GRASS AREA

FIELD VERIFY

BARB ARM

UPPER GUIDE

ASSEMBLY

SLIDING GATE

3'-0"

3' -6

3'

-0

6"

ASPHALT

PAVING

POST (TYP.)

BOTH SIDES

2 3/8" DIA. SCH. 40 GALV

STEEL PIPE @

PERIMETER GATE FRAME

6" V-GROVE WHEEL

2 DIA. SCH. 40 GALV.

STEEL PIPE @

VERTICAL UPRIGHTS

12' INTERIOR

UPPER GUIDE BRACKET

4" O.D. POST

NON-MARRING 12 58 "

GUIDE WHEEL

3/8" CONCRETE

ANCHOR (TYP.)

6"

2'

GRADE VARIES

2 3/8" DIA. SCH. 40 GALV. STEEL

PIPE @ PERIMETER GATE FRAME

2" W x 4" L x 1 12" H GALV.

CHANNEL WELDED TO PROTECTIVE

COVER AND STEEL PIPE GATE FRAME

GALV. STEEL

PROTECTIVE COVER

6" V-GROOVE

WHEEL

V- SHAPED GALVANIZED

STEEL ANGLE TRACK

WELDED TO GALV. STEEL

CHANNEL W / 3/8" x 3" ANCHORS

TOP AND BOTTOM TENSION BAR @

PERIMETER OF GATE PIPE FRAME

TO ATTACH GALV. WIRE MESH

2" DIA. SCH. 40

GALV. STEEL PIPE @

VERTICAL UPRIGHTS2" GALV. WIRE MESH FABRIC

CATCHER

COMPANION

GATE FRAME

SLIDING GATE POST

7' -6

6'

-0

1'-0"

6" 2'

-6

2' -0

VARIES2'-0"

LINE

POSTS

V-GROOVE WHEEL

(TYP.) REFER TO

DTL. 5/TY5.11

2" DIA. SCH. 40 GALV.

STEEL PIPE @

PERIMETER GATE FRAME

3' -6

6" CONCRETE

CURBS

8" DIA. TRUSS ROD

WITH TURNBUCKLE

2'-0"

3' -6

6"

BARBED

WIRE

2" MESH GALV.

WIRE FABRIC

GROUNDING,

REFER TO

FENCE SPECS

BARB ARM (TYP.)

AT GATE

BOTTOM OF FENCE

FABRIC TO CLEAR

TOP OF CONCRETE

CURB

2" DIA. SCH. 40 GALV.

STEEL PIPE @ PERIMETER

GATE FRAME

V-GROOVE TRACK

GATE

POST

FOUNDATION

BEYOND

1" x 2" SCH 40 GALV

(TYP.)

SLIDING GATE

POST (TYP.)HORIZONTAL

BRACE RAIL

SLIDING GATE

POST (TYP.)

SCALE:1 PLAN VIEW OF V TRACK SECURITY GATE

NTS

SCALE:2 STANDARD ROLLING GATE DETAIL

NTS

SCALE:3 UPPER GUIDE ASSEMBLY

NTS SCALE:4 CATCH ASSEMBLY

NTS

SCALE:5 V-GROOVE WHEEL ASSEMBLY & CONCRETE TROUGH

NTS

Support Services Division Facilities Planning & Management

Date: 07/10/2023

Drawn by: JA/DM

Checke…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .