ESBD_521436_1780090813805_02. Specification.pdf
PDF 3 MB Posted
- Solicitation number
- 601330000046273
- Issued by
- Brazoria County, Amarillo City, Texas
About this file
This specification document pertains to a Texas state and local contract opportunity for equipment procurement. The document establishes technical requirements and performance standards for the products or services to be supplied under this contract. The specification details the functional requirements, quality standards, and operational parameters that all bidders must meet or exceed in their submissions. While the document does not explicitly state response deadlines, due dates, or award timelines within the specification itself, these dates would typically be found in the associated solicitation documents or request for proposals. Site visits and bidders' conferences, if applicable to this opportunity, would be communicated through separate solicitation notices. The contract term and any renewal options would be specified in the primary solicitation documents accompanying this specification.
The specification focuses on establishing clear technical benchmarks and performance criteria that all vendors must satisfy regardless of pricing considerations. Pricing terms, set-asides for small businesses or disadvantaged vendors, incumbent contractor information, and funding sources would be outlined in the main solicitation documents rather than in this technical specification. Any specific dollar amounts, budget allocations, and funding authorizations for this procurement would be detailed in the official request for proposals or invitation for bids. Bidders should reference the complete solicitation package to obtain all procurement details including timeline, budget parameters, and any applicable contract modifications or addenda.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| ESBD_521436_1780090903482_Bid Table 601330000046273.xlsx | XLSX spreadsheet | |
| Bid_notify_601330000046273.txt | TXT text file | |
| ESBD_521436_1780090886723_06. Exceptions Schedule.xlsx | XLSX spreadsheet | |
| ESBD_521436_1780090792450_01. RFO 601330000046273.pdf | ||
| ESBD_521436_1780090870808_05. Assumptions Schedule.xlsx | XLSX spreadsheet | |
| ESBD_521436_1780090829763_03. Execution of Offer.docx | DOCX document | |
| ESBD_521436_1780090851200_04. Texas Family Code Schedule.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SmartSensor Matrix
16–beam stop bar sensor The SmartSensor Matrix is a fi rst-of-its-kind stop bar presence detector designed for use at signalized intersections to detect vehicles with the reliability of radar and with all the advantages of non-intrusive detection.
˿ Matrix of 16 radars for two-dimen-sional coverage
˿ Tracks vehicles through a 90 de-gree fi eld of view that extends out 140 ft. (42.7 m)
˿ Includes Radar Vision technology to detect and track in two dimensions
˿ Reports real-time presence of both moving and stopped vehicles
˿ Standard detector-rack contact-closure interface
˿ Easy to install and operate ˿ Supports curved and angled lanes ˿ Compatible with Click 65x all-in-one cabinet interface device ˿ Automated manufacturing process
˿ Patented auto-confi guration process
˿ Patented Digital Wave Radar II technology
˿ Remote accessible for traffi c moni-toring and sensor management
˿ Flash upgradable ˿ Robust to changing temperature, light and weather conditions
78 E 1700 S, Provo, UT 84606, US � (801) 734-7200 � www.wavetronix.comWX-500-0071 1 of 13
Technical specifications Sensor outputs
| ˿ Real-time presence data across a 140-ft. (42.7-m) range |
| ˿ Maximum number of zones: 16 |
| ˿ Maximum number of channels: 16 |
| ˿ User-selectable zone to channel mapping |
| ˿ AND logic triggers the channel when all the selected zones are |
active
| ˿ OR logic used to combine multiple zones to a channel output |
| ˿ Channel output extend and delay functionality |
| ˿ Algorithms mitigate detections from wrong way or cross traffic |
| ˿ Fail-safe mode for contact closure outputs if communication is lost |
Detectable area
| ˿ Detection range: 6 to 140 ft. (1.8 to 42.7 m) |
| ˿ Field of view: 90º |
| ˿ Flexible lane configuration support including: |
| ̀ Up to 10 lanes |
| ̀ Curved lanes |
| ̀ Islands and medians |
System hardware ˿ A complete SmartSensor Matrix system includes the following hardware:
| ̀ A SmartSensor Matrix corner radar for each approach |
| ̀ Either a preassembled backplate or a cabinet interface |
device (the Click 600, 650 or 656) ̀ Contact closure input file cards (if using a preassembled backplate or Click 600): 2 or 4 channel, compatible with industry standard detector racks
Maintenance
| ˿ No cleaning or adjustment necessary |
| ˿ No battery replacement necessary |
| ˿ Recalibration is not necessary |
| ˿ Mean time between failures: 10 years (estimated based on |
manufacturing techniques)
Physical properties
| ˿ Weight: 4.2 lbs. (1.9 kg) |
| ˿ Physical dimensions: 13.2 in. × 10.6 in. × 3.3 in. (33.5 cm x 26.9 |
cm x 8.4 cm) ˿ Resistant to corrosion, fungus, moisture deterioration, and ultraviolet rays
| ˿ Enclosure: Lexan EXL polycarbonate |
| ˿ Outdoor weatherable: UL 746C |
| ˿ Watertight by NEMA 250 standard |
| ˿ NEMA 250 compliant for: |
| ̀ External icing (clause 5.6) |
| ̀ Hose down (clause 5.7) |
| ̀ 4X corrosion protection (clause 5.10) |
| ̀ Gasket (clause 5.14) |
| ˿ Withstands 5-ft. (1.5-m) drop |
| ˿ Connector: MIL-C-26482 |
| ˿ Rotational backplate for 360º of roll |
Electrical
| ˿ Power consumption: 9 W |
| ˿ Power supply voltage: 10–28 VDC * |
| ̀ Recommended power supply voltage: 12–24 VDC * |
| ˿ Onboard surge protection |
Ordering information SmartSensor Matrix
SS-225
Accessories 102-0416/102-0451 – Click 650/656 CLK-112/114 – Click 112/114 SS-704-xxx/705 – SmartSensor 6-conductor Cable SS-611 – SmartSensor Mount 101-0462 – Span Wire Mount SS-B01-0003/0005/0008 – Intersection Preassem-bled Backplate – AC SS-B01-0004/0006 – Intersection Preassembled Backplate – DC SS-B02-0002/0003 – Intersection Preassembled 19-inch Rack SS-710 – Sensor Cable Junction Box
Contact us 801.734.7200 sales@wavetronix.com www.wavetronix.com
* While the system works with supply voltages of up to 28 VDC, 24 VDC supplies are recommended; the excess is designed to allow some tolerance on the output of the supply.
To support 12 VDC battery systems, and if the cable is short enough, the sensor can accept a power supply as low as 10 VDC; however, if the cable exceeds ### ft. in length, the power supply must be at least 12 VDC.
Communication ports ˿ Two half-duplex RS-485 COM ports support:
| ̀ Dedicated detection communications |
| ̀ Configuration, verification or traffic display without disrupt- |
ing detection communications
| ˿ Firmware upgradability over any COM port |
| ˿ User configurable: |
| ̀ Response delay |
| ̀ Push port |
Radar design
| ˿ Operating frequency: 24.0–24.25 GHz (K-band) |
| ˿ Matrix of 16 radars |
| ˿ No manual tuning to circuitry |
| ˿ Uses frequency modulated continuous wave (FMCW) radar |
| ˿ No temperature-based compensation necessary |
| ˿ Bandwidth stable within 1% |
| ˿ Printed circuit board antennas |
| ˿ Antenna vertical 6 dB beam width (two-way pattern): 65° |
| ˿ Horizontal field of view: 90º |
| ˿ Antenna two-way sidelobes: -40 dB |
| ˿ Transmit bandwidth: 245 MHz |
| ˿ Un-windowed resolution: 2 ft. (0.6 m) |
| ˿ RF channels: 8 |
| ˿ Self-test for verifying hardware functionality |
| ˿ Diagnostics mode for verifying system functionality |
Configuration ˿ Automatic and manual configuration of lanes, stop bars and zones
| ˿ Lane positioning increment: 1 ft. (0.3 m) |
| ˿ Four-sided zones of any shape and size |
| ˿ Overlapping zones supported |
| ˿ Sensor reconfiguration without detection disruption supported |
| ˿ Graphical user interface with traffic pattern display |
| ˿ Counting and pulse channels supported |
| ˿ Supported operating systems: |
| ̀ Windows 7 |
| ̀ Windows 8 |
| ̀ Windows 10 |
| ˿ Software-supported functionality: |
| ̀ TCP/IP connectivity |
| ̀ Sensor configuration backup and restore |
| ̀ Backed-up sensor configurations can be viewed and |
edited ̀ Real-time traffic visualization for performance verification and traffic display
| ̀ Zone and channel actuation display |
| ̀ Virtual sensor connections for demonstration and training |
| ̀ Local or remote sensor firmware upgradability |
Operating conditions ˿ Accurate performance in:
| ̀ Rain up to 1 in. (2.5 cm) per hour |
| ̀ Freezing rain |
| ̀ Dry snowfall and moist snowfall |
| ̀ Wind |
| ̀ Dust |
| ̀ Fog |
| ̀ Changing temperature |
| ̀ Changing lighting (even direct light on sensor at dawn and |
dusk) ̀ Ice and dry snow buildup up to 0.2 in. (0.5 cm) on sensor front
| ˿ Ambient operating temperature: -40°F to 165°F (-40°C to 74°C) |
| ˿ Humidity: Up to 95% RH (non-condensing) |
Testing
| ˿ Tested under FCC CFR 47, part 15, section 15.249 |
| ˿ FCC certification on product label |
| ˿ FCC regulation-compliant for life of the sensor |
| ˿ Tested under IEC 61000-4-5 class 4 (lightning surge protection) |
| ˿ Tested under NEMA TS 2-2003 |
| ̀ Shock pulses of 10 g, 11 ms half sine wave |
| ̀ Vibration of 0.5 g up to 30 Hz |
| ̀ 300 V positive/negative pulses |
| ̀ Stored at -49ºF (-45ºC) for 24 hours |
| ̀ Stored at 185ºF (85ºC) for 24 hours |
| ̀ Operation at -29.2ºF (-34ºC) and 10.8 VDC |
| ̀ Operation at -29.2ºF (-34ºC) and 26.5 VDC |
| ̀ Operation at 165.2ºF (74ºC) and 26.5 VDC |
| ̀ Operation at 165.2ºF (74ºC) and 10.8 VDC |
Manufacturing
| ˿ Manufactured in the USA |
| ˿ Surface mount assembly |
| ˿ IPC-A-610C Class 2–compliant |
| ˿ Operational testing: |
| ̀ Sub-assembly test |
| ̀ 48-hour unit level burn-in |
| ̀ Final unit test |
˿ Unit test results available
Support
| ˿ Training and tech support available from Wavetronix |
| ˿ Wavetronix training includes: |
̀ Installation and configuration instruction to ensure accu-rate performance
| ̀ Classroom and in-field instruction |
| ̀ Knowledgeable trainers |
| ̀ Use of presentation materials |
| ̀ Virtual configuration using computer playback |
| ˿ Wavetronix tech support includes: |
̀ Technical representatives available for installation and configuration
̀ Ongoing troubleshooting and maintenance support
Documentation
| ˿ Instructional training guide |
| ˿ Comprehensive user guide |
| ˿ Installer quick-reference guide |
| ˿ User quick-reference guide |
| ˿ Certification documentation available upon request |
Warranty ˿ Two-year warranty against material and workmanship defects
(see SmartSensor Warranty datasheet for complete details)
The advertised detection accuracy of the company’s sensors is based on both external and internal testing, as outlined in each product’s specification document. Although our sensors are very accurate by industry standards, like all other sensor manufacturers we cannot guarantee perfection or assure that no errors will ever occur in any particular applications of our technology. Therefore, beyond the express Limited Warranty that accompanies each sensor sold by the company, we offer no additional representations, warranties, guarantees or remedies to our customers. It is recommended that purchasers and integrators evaluate the accuracy of each sensor to determine the acceptable margin of error for each application within their particular system(s).
Bid specifications
1.0 General. This item shall govern the purchase of aboveground radar presence detector (RPD) equivalent to the Wavetronix SmartSensor Matrix.
An RPD detects vehicles by transmitting electromagnetic radar signals through the air. The signals bounce off vehicles in their paths and part of the signal is returned to the RPD. The returned signals are then processed to determine traffic parameters.
RPDs are not affected by normal weather and environmental conditions such as rain, wind, dry snowfall, moist snowfall, dust, etc. They also do not require cleaning and can maintain performance over a wide range of ambient temperatures.
RPDs provide a non-intrusive means of detecting traffic. This property not only makes them safer to install but also more cost effective than sensors that require roadway modifications or placement.
2.0 Sensor outputs. The RPD shall present real-time presence data across a 140-ft. (42.7-m) range.
The RPD shall support a minimum of 16 zones.
The RPD shall support a minimum of 16 channels.
The RPD shall support user-selectable zone to channel mapping.
The RPD shall use AND logic to trigger channels when all selected zones are active.
The RPD shall use OR logic to combine multiple zones to a channel output, and shall have channel output extend and delay functionality.
The RPD algorithms shall mitigate detections from wrong way or cross traffic.
The RPD system shall have fail-safe mode capabilities for contact closure outputs if communication is lost.
3.0 Detectable area.
3.1 Detection range. The RPD shall be able to detect and report presence in lanes with boundaries as close as 6 ft. (1.8 m), measured laterally, from the RPD.
The RPD shall be able to detect and report presence in lanes located within the 140 ft. (42.7 m) arc, measured laterally, from the RPD.
3.2 Field of view. The RPD shall be able to detect and report presence for vehicles within a 90 degree field of view.
3.3 Lane configuration. The RPD shall be able to detect and report presence in up to 10 lanes.
The RPD shall be able to detect and report presence in curved lanes and areas with islands and medians.
4.0 System hardware. For each approach to be detected, one RPD corner radar shall be used.
4.1 Connectivity and surge. Each RPD shall be used with a preassembled backplate or a cabinet interface device.
If a traffic cabinet preassembled backplate, it shall have the following:
| • | AC/DC power conversion |
| • | Surge protection |
| • | Terminal blocks for cable landing |
| • | Communication connection points |
| • | The preassembled backplate for the RPD shall be a cabinet side mount or rack mount |
If a cabinet interface device, it shall be a single device that performs the following functions:
| • | Provide DC power to up to four connected sensors |
| • | Provide surge protection for those sensors |
| • | Communicate between the device and a connected computer |
| • | Communicate with contact closure devices and/or a traffic controller |
4.2 Contact closure input file cards. The RPD may use contact closure input file cards with 2 or 4 channel capabilities.
The contact closure input file cards for the RPD shall be compatible with industry standard detector racks.
5.0 Maintenance. The RPD shall not require cleaning or adjustment to maintain performance.
The RPD shall not rely on battery backup to store configuration information, thus eliminating any need for battery replacement.
Once the RPD is calibrated, it shall not require recalibration to maintain performance unless the roadway configuration changes.
The mean time between failures shall be 10 years, which is estimated based on manufacturing techniques.
6.0 Physical properties. The RPD shall not exceed 4.2 lbs. (1.9 kg) in weight.
The RPD shall not exceed 13.2 in. by 10.6 in. by 3.3 in. (33.5 cm x 26.9 cm x 8.4 cm) in its physical dimensions.
All external parts of the RPD shall be ultraviolet-resistant, corrosion-resistant, and protected from fungus growth and moisture deterioration.
6.1 Enclosure. The RPD shall be enclosed in a Lexan EXL polycarbonate.
The enclosure shall be classified “f1” outdoor weatherability in accordance with UL 746C.
The RPD shall be classified as watertight according to the NEMA 250 standard.
The RPD enclosure shall conform to test criteria set forth in the NEMA 250 standard for type 4X enclosures. Test results shall be pro-vided for each of the following type 4X criteria:
| • | External icing (NEMA 250 clause 5.6) |
| • | Hose-down (NEMA 250 clause 5.7) |
| • | 4X corrosion protection (NEMA 250 clause 5.10) |
| • | Gasket (NEMA 250 clause 5.14) |
The RPD shall be able to withstand a drop of up to 5 ft. (1.5 m) without compromising its functional and structural integrity.
The RPD enclosure shall include a connector that meets the MIL-C-26482 specification. The MIL-C-26482 connector shall provide contacts for all data and power connections.
7.0 Electrical. The RPD shall consume less than 10 W.
The RPD shall operate with a DC input between 10 VDC and 28 VDC.
The RPD shall have onboard surge protection.
8.0 Communication ports. The RPD shall have two communication ports, and both ports shall communicate independently and simultaneously.
Two independent communication ports allow one port to be used for configuration, verification and traffic monitoring without interrupting communications on the dedicated data port.
The RPD shall support the upload of new firmware into the RPD’s non-volatile memory over either communication port.
The RPD shall support the user configuration of the following:
| • | Response delay |
| • | Push port |
The communication ports shall support a 9600 bps baud rate.
9.0 Radar design. The RPD shall be designed with a matrix of 16 radars.
The matrix of 16 radars enables the sensor to provide detection over a large area and to discriminate lanes.
9.1 Frequency stability. The circuitry shall be void of any manual tuning elements that could lead to human error and degraded perfor-mance over time.
The RPD shall use frequency modulated continuous wave (FMCW) radar. All transmit modulated signals shall be generated by means of digital circuitry, such as a direct digital synthesizer, that is referenced to a frequency source that is at least 50 parts per million (ppm) stable over the specified temperature range, and ages less than 6 ppm per year. Any upconversion of a digitally generated modulated signal shall preserve the phase stability and frequency stability inherent in the digitally generated signal.
This specification ensures that, during operation, the RPD strictly conforms to FCC requirements and that the radar signal quality is maintained for precise algorithmic quality. Analog and microwave components within an RPD have characteristics that change with temperature variations and age. If the output transmit signal is not referenced to a stable frequency source, then the RPD is likely to experience unacceptable frequency variations which may cause it to transmit out of its FCC allocated band and thus will be non-compliant with FCC regulations.
The RPD shall not rely on temperature compensation circuitry to maintain transmit frequency stability.
Temperature-based compensation techniques have been shown to be insufficient to ensure transmit frequency stability. One reason this type of technique is not sufficient is that it does not compensate for frequency variations due to component aging.
The bandwidth of the transmit signal of the RPD shall not vary by more than 1% under all specified operating conditions and over the expected life of the RPD.
The bandwidth of an RPD directly affects the measured range of a vehicle. A change in bandwidth causes a direct error in the mea-sured range, i.e., a 5% change in bandwidth would cause a range error of 10 ft. (3 m) for a vehicle at 200 ft. (61 m). If the bandwidth changes by more than 1% due to seasonal temperature variations and component aging, then the RPD will need to be frequently reconfigured to maintain the specified accuracy.
9.2 Antenna design. The RPD antennas shall be designed on printed circuit boards.
Printed circuit board antennas eliminate the need for RF connectors and cabling that result in decreased reliability. Printed circuit antennas are less prone to physical damage due to their extremely low mass.
The vertical beam width of the RPD at the 6 dB points of the two-way pattern shall be 65 degrees or greater.
The antennas shall cover a 90 degree horizontal field of view.
The sidelobes in the RPD two-way antenna pattern shall be -40 dB or less.
Low sidelobes ensure that the performance from the antenna beam widths is fully achieved.
9.3 Resolution. The RPD shall transmit a signal with a bandwidth of at least 245 MHz.
The bandwidth of the transmit signal translates directly into radar resolution, which contributes directly to detection performance. For example, an RPD that transmits at a low bandwidth will have low radar resolution, which could cause it to count a single vehicle as two vehicles in adjacent lanes. As another example of the adverse effects of low radar resolution, the response from a sign or other radar target in the roadway may spill over into the lanes of travel and desensitize the radar. In order to achieve the specified detec-tion accuracy in a variety of conditions, the unwindowed radar resolution cannot be larger than 2 ft. (0.6 m) at the half-power level, which requires a bandwidth of 240 MHz. The high radar resolution reduces the problem of vehicle responses getting drowned out by brighter vehicles in adjacent lanes and improves performance for moving and stopped vehicles near roadway targets.
9.4 RF Channels. The RPD shall provide at least 8 RF channels so that multiple units can be mounted in the same vicinity without caus-ing interference between them.
9.5 Verification. The RPD shall have a self-test that is used to verify correct hardware functionality.
The RPD shall have a diagnostics mode to verify correct system functionality.
10.0 Configuration.
10.1 Auto-configuration. The RPD shall have a method for automatically defining traffic lanes, stop bars and zones without requiring user intervention. This auto-configuration process shall execute on a processor internal to the RPD and shall not require an external PC or other processor.
The auto-configuration process shall work under normal intersection operation and may require several cycles to complete.
10.2 Manual configuration. The auto-configuration method shall not prohibit the ability of the user to manually adjust the RPD configuration.
The RPD shall support the configuring of lanes, stop bars and detection zones in 1-ft. (0.3-m) increments.
When lanes have variable widths or have variable spacing (e.g. gore between lanes), precise resolution is necessary.
10.3 Windows-based software. The RPD shall include graphical user interface software that displays all configured lanes and the cur-rent traffic pattern using a graphical traffic representation.
A visual representation of traffic patterns allows an installer to quickly associate specific detections with corresponding vehicles, and it facilitates verification of RPD performance.
The RPD shall include the ability to do counting and pulse channels.
The graphical interface shall operate on Windows 7, Windows 8, and Windows 10 in the .NET framework.
The software shall support the following functionality:
| • | Operate over a TCP/IP connection |
| • | Give the operator the ability to save/back up the RPD configuration to a file or load/restore the RPD configuration from a file |
| • | Allow the backed-up sensor configurations to be viewed and edited |
| • | Provide zone and channel actuation display |
| • | Provide a virtual connection option so that the software can be used without connecting to an actual sensor |
| • | Local or remote sensor firmware upgradability |
11.0 Operating conditions. The RPD shall maintain accurate performance in all weather conditions, including rain, freezing rain, dry snow-fall, moist snowfall, wind, dust, fog and changes in temperature and light, including direct light on sensor at dawn and dusk. The RPD shall maintain accurate performance with ice and dry snow buildup on the sensor front.
RPD operation shall continue in rain up to 1 in. (2.5 cm) per hour.
The RPD shall be capable of continuous operation over an ambient temperature range of -40°F to 165.2°F (-40°C to 74°C).
The RPD shall be capable of continuous operation over a relative humidity range of 5% to 95% (non-condensing).
Dry snow and moist snow are terms defined by the International Hydrological Program of the United Nations in the publication “The Internation-al Classification For Seasonal Snow on the Ground.” Dry snow has a water volume content of 0% and moist snow has water content of less than 3%. Wet snow has higher fractional volumes of water and varying fractional volumes of air. Depending on the precipitation rate and the fraction-al volumes of ice, air, and water, the RPD shall be capable of continuous operation in wet snowfall. For example, with typical fractional volumes of ice, air, and water the RPD shall be capable of continuous operation in wet snowfall with a precipitation rate less than 1 in. per hour (2.5 cm) per hour. Furthermore, as instructed in the user documentation, the sensor should be installed with a down tilt for accurate detection. A down tilt alignment will also help shield the sensor front and minimize the possibility of dry, moist, and wet snow buildup in extreme weather conditions.
12.0 Testing.
12.1 FCC. Each RPD shall be certified by the Federal Communications Commission (FCC) under CFR 47, part 15, section 15.249 as an intentional radiator.
The FCC certification shall be displayed on an external label on each RPD according to the rules set forth by the FCC.
The RPD shall comply with FCC regulations under all specified operating conditions and over the expected life of the RPD.
The RPD shall be tested under IEC 61000-4-5 class 4 (lightning surge protection).
12.2 NEMA TS 2-2003 testing. The RPD shall comply with the applicable standards stated in the NEMA TS 2-2003 standard. Third-party test results shall be made available for each of the following tests:
| • | Shock pulses of 10 g, 11 ms half sine wave |
| • | Vibration of 0.5 g up to 30 Hz |
| • | 300 V positive/negative pulses applied at one pulse per second at minimum and maximum DC supply voltage |
| • | Cold temperature storage at -49°F (-45°C) for 24 hours |
| • | High temperature storage at 185°F (85°C) for 24 hours |
| • | Low temp, low DC supply voltage at -29.2°F (-34°C) and 10.8 VDC |
| • | Low temp, high DC supply voltage at -29.2°F (-34°C) and 26.5 VDC |
| • | High temp, high DC supply voltage at 165.2°F (74°C) and 26.5 VDC |
| • | High temp, low DC supply voltage at 165.2°F (74°C) and 10.8 VDC |
13.0 Manufacturing. The RPD shall be manufactured and assembled in the USA.
The internal electronics of the RPD shall utilize automation for surface mount assembly, and shall comply with the requirements set forth in IPC-A-610C Class 2, Acceptability of Electronic Assemblies.
The RPD shall undergo a rigorous sequence of operational testing to ensure product functionality and reliability. Testing shall include the following:
| • | Functionality testing of all internal sub-assemblies |
| • | Unit level burn-in testing of 48 hours’ duration or greater |
| • | Final unit functionality testing prior to shipment |
Test results and all associated data for the above testing shall be provided for each purchased RPD by serial number, upon request.
14.0 Support. The RPD manufacturer shall provide both training and technical support services.
14.1 Training. The manufacturer-provided training shall be sufficient to fully train installers and operators in the installation, configura-tion, and use of the RPD to ensure accurate RPD performance.
The manufacturer-provided training shall consist of comprehensive classroom labs and hands-on, in-the-field, installation and configu-ration training.
Classroom lab training shall involve presentations outlining and defining the RPD, its functions, and the procedures for proper opera-tion. These presentations shall be followed by hands-on labs in which trainees shall practice using the equipment to calibrate and configure a virtual RPD. To facilitate the classroom presentation and hands-on labs, the manufacturer-provided training shall include the following items:
| • | Knowledgeable trainer or trainers thoroughly familiar with the RPD and its processes |
| • | Presentation materials, including visual aids, printed manuals and other handout materials for each student |
| • | Computer files, including video and raw data, to facilitate the virtual configuration of the RPD |
| • | Laptop computers or Windows CE handheld devices with the necessary software, and all necessary cables, connectors, etc. |
| • | All other equipment necessary to facilitate the virtual configuration of the RPD |
Field training shall provide each trainee with the hands-on opportunity to install and configure the RPD at roadside. Training shall be such that each trainee will mount and align the RPD correctly.
14.2 Technical assistance. Manufacturer-provided technical support shall be available according to contractual agreements, and a technical representative shall be available to assist with the physical installation, alignment, and auto-configuration of each supplied
RPD. Technical support shall be provided thereafter to assist with troubleshooting, maintenance, or replacement of RPDs should such services be required.
15.0 Documentation. RPD documentation shall include an instructional training guide and a comprehensive user guide as well as an in-staller quick-reference guide and a user quick-reference guide.
Certification documentation shall be available upon request.
16.0 Warranty. The RPD shall be warranted free from material and workmanship defects for a period of two years from date of shipment.
The advertised detection accuracy of the company’s sensors is based on both external and internal testing, as outlined in each product’s specification document. Although our sensors are very accurate by industry standards, like all other sensor manufacturers we cannot guarantee perfection or assure that no errors will ever occur in any particular applications of our technology. Therefore, beyond the express Limited Warranty that accompanies each sensor sold by the company, we offer no additional representations, warranties, guarantees or remedies to our customers. It is recommended that purchasers and integrators evaluate the accuracy of each sensor to determine the acceptable margin of error for each application within their particular system(s).
Installation specifications
1.0 General. This item shall govern the installation of an aboveground radar presence detector (RPD) equivalent to the Wavetronix SmartSensor Matrix.
RPDs can provide accurate, consistent, and reliable presence detections provided they are installed properly. The requirements in this specification are intended to ensure proper RPD installation.
2.0 Mounting and installation.
2.1 Mounting assembly. The RPD shall be mounted directly onto a mounting assembly fastened to a mast arm, pole or other solid structure. In qualifying tethered (double) span wire intersections, the mounting assembly may be fasted to a hanger assembly that is affixed to the span wire.
The RPD mounting assembly shall provide the necessary degrees of rotation to ensure proper installation.
The RPD mounting assembly shall be constructed of weather-resistant materials and shall be able to support a 20-lb. (9.1-kg) load.
2.2 Mounting location. The RPD shall be mounted at a height that is within the manufacturer’s recommended mounting heights.
The RPD shall be mounted at an offset from the first lane that is consistent with the RPD’s minimum offset.
The RPD shall be mounted so that at least 20 feet along the farthest lane to be monitored is within the field view of the RPD.
The RPD shall be mounted with its cable connector down and shall be tilted so that the RPD is aimed at the center of the lanes to be monitored. Typically, the RPD is tilted off of vertical by 20–30 degrees.
The RPD shall be mounted on a vertical signal pole or on the horizontal mast arm, or, in qualifying tethered (double) span wire intersec-tions, on the span wire.
The RPD shall be mounted so that its field of view is not occluded by poles, signs or other structures.
RPDs that are mounted within 20 ft. (6.1 m) of each other or that are monitoring the same intersection shall be configured to operate on different RF channels regardless of the pointing direction of the RPDs.
It is recommended that the manufacturer be consulted to verify final RPD placement if the RPD is to be mounted near large planar surfaces (sound barrier, building, parked vehicles, etc.) that run parallel to the monitored roadway.
2.3 Cabling. The cable end connector shall meet the MIL-C-26482 specification and shall be designed to interface with the appropri-ate MIL-C-26482 connector. The connector backshell shall be an environmentally sealed shell that offers excellent immersion capa-bility. All conductors that interface with the connector shall be encased in a single jacket, and the outer diameter of this jacket shall be within the backshell’s cable O.D. range to ensure proper sealing. The backshell shall have a strain relief with enough strength to support the cable slack under extreme weather conditions. Recommended connectors are Cannon’s KPT series, and recommended backshells are Glenair Series 37 cable sealing backshells.
The cable shall be the Wavetronix SS-704-xxx or an equivalent cable that conforms to the following specifications:
| • | The RS-485 conductors shall be a twisted pair. |
| • | The RS-485 conductors shall have nominal capacitance conductor to conductor of less than 40 pF/ft. at 1 kHz. |
| • | The RS-485 conductors shall have nominal conductor DC resistance of less than 16.7 ohms/1000 ft. (304.8 m) at 68°F (20°C). |
| • | The power conductors shall be one twisted pair with nominal conductor DC resistance of less than 11.5 ohms/1000 ft. (304.8 m) at |
68°F (20°C).
• Each wire bundle or the entire cable shall be shielded with an aluminum/mylar shield with a drain wire.
The cable shall be terminated only on the two farthest ends of the cable.
The cable length shall not exceed 2000 ft. (609.6 m) for the operational baud rate of RS-485 communications (9.6 Kbps).
If 12 VDC is being supplied for the RPD then the cable length shall not exceed 110 ft. (33.5 m).
If 24 VDC is being supplied for the RPD then the cable length shall not exceed 600 ft. (182.9 m).
Both communication and power conductors can be bundled together in the same cable as long as the abovementioned conditions are met.
2.4 In-cabinet interface equipment. The RPD shall be installed using the Click 600, 650 or 656 cabinet interface device, a Wavetronix preassembled backplate, or an equivalent that provides input power surge suppression, sensor cable surge suppression, AC to DC power conversion (if necessary), and terminal blocks.
2.5 Lightning surge protection. The RPD has onboard surge protection; proper grounding is required for effective surge protection.
Consult the article titled Intersection Grounding Schematics in the knowledge base on the Wavetronix website for more information.
Appropriate lightning surge protection shall be installed in the traffic cabinet to protect the cabinet equipment. These lightning surge protection devices shall meet or exceed the IEC 61000-4-5 Class 4 specifications. The Wavetronix Click 222 and Click 65x devices both meet those standards. The lightning surge protection unit supplied shall be physically compatible with the cable provided.
2.6 Power supply. The RPD shall be installed using the Click 65x, the Click 202 or Click 204 (included on the Wavetronix preassem-bled backplate), or an equivalent AC to DC power converter that meets the following specifications:
The power converter shall be power rated at 48 W for temperatures less than 140°F (60°C) with a 5% power decrease for each degree Celsius increase up to 158°F (70°C).
The power converter shall operate in the temperature range of to -29.2°F to 165.2°F (–34°C to 74°C).
The power converter shall operate in the humidity range of 5% to 95% at 77°F (25°C) non-condensing.
The power converter shall accept an input voltage of 85 to 264 VAC or 120 to 370 VDC.
The power converter shall operate at an input frequency of 47 Hz to 63 Hz.
The power converter shall produce an output voltage of 24 VDC ±4%.
The power converter shall withstand a voltage across its input and output of 3 kV. The power converter shall withstand a voltage across its input and ground of 1.5 kV.
The power converter shall conform to safety standards UL 60950-1 and EN 60950-1 and be certified and tested to meet the limited power source requirement according to clause 2.5. Its output current shall be limited to a maximum current of 4A both under normal and single fault condition; with double/reinforced insulation between its input and output circuits.
The power converter shall conform to EMC standards EN 55022 Class B and EN 61000-3-2, 3.
In brown-out conditions (i.e. < 85 VAC input), the output voltage of the power converter shall be less than 1 VDC.
The terminal blocks shall be color-coded insulation displacement terminal blocks.
The terminal blocks shall be prewired to the other in-cabinet equipment so that no wiring other than cable terminations, connecting input power and connecting input file cards shall be required during installation.
2.7 Input file cards. The Click 114, Click 112 or an equivalent that meets the following specifications shall be used when using a preas-sembled backplate or Click 600:
The input file cards shall be compatible with 170, 2070, NEMA TS 1, and NEMA TS 2 style input racks.
The input file card shall translate data packets from the RPD into contact closure outputs.
The input file card shall support presence detection.
The input file card shall receive data packets over an RS-485 bus at a baud rate of 9600 bps.
The input file card shall autobaud and auto-detect an RPD over wired and wireless communication channels that have a maximum latency of 500 ms.
The input file card shall comply with the NEMA TS 2-1998 or newer Traffic Controller Assemblies with NTCIP Requirements (Section 2.8 specification).
SmartSensor Mount
Pole mount for SmartSensors The SmartSensor mount makes installation quick and easy by helping you securely mount any of the Wavetronix SmartSensors. Sturdily built of powder-coated aluminum for durability and weather-resistance, this mount can withstand whatever the elements throw at it.
˿ Two axes of rotation for horizontal and vertical positioning
˿ Mates with fixed and rotational backplates on the SmartSensor V, HD, Advance, and Matrix
˿ Symmetric hole pattern for flex-ibility in sensor attachment
˿ Two contact points for attachment to circular or non-circular poles
˿ On circular poles, another axis of rotation around the pole is avail-able
| ˿ Accepts ¾” banding |
| ˿ Heavy duty aluminum construction |
makes mount sturdy and long-lasting
˿ Powder coated for oxidization resistance, allowing mount to withstand the harshest weather conditions
˿ Supports a 20-lb. (9.1-kg) load
8 in.6 in.
13.61 in.
3.79 in.
78 E 1700 S, Provo, UT 84606, US • (801) 734-7200 • www.wavetronix.comWX-500-0072 1 of 3
Mounting
| ˿ Rotational axes: 2 |
| ̀ NOTE: SmartSensor Advance and SmartSensor Matrix are |
shipped with rotational backplate for third axis of rotation.
SmartSensor V and SmartSensor HD can be ordered with rotational backplate if third axis is required.
| ˿ Maximum load: 20 lbs. (9.1 kg) |
| ˿ Symmetric hole pattern that mates with fixed and rotational |
SmartSensor backplates
| ˿ Contact points with pole: 2 |
| ˿ Slotted for ¾-in. (1.9-cm) banding |
| ˿ Additional degree of movement achieved by using the |
360-0129
Construction
| ˿ Constructed of aluminum 0.1875 in. (0.48 cm) thick |
| ˿ 316 stainless steel hardware |
| ˿ Powder coated |
| ˿ Weight: 3 lbs. (1.36 kg) |
Ordering information SmartSensor Mount
SS-611
Accessories 360-0129 – SmartSensor Mount Knuckle
Contact us 801.734.7200 sales@wavetronix.com www.wavetronix.com
1.0 General. This item shall govern the purchase of a traffic sensor mounting assembly equivalent to the Wavetronix SmartSensor™ mount.
2.0 �Mounting. The mounting assembly shall provide at least two axes of rotation to ensure proper installation.
The mounting assembly shall be able to support at least a 20-lb. (9.1-kg) load.
The mounting assembly shall feature a symmetric hole pattern that mates with fixed and rotational SmartSensor backplates.
The mounting assembly shall have two contact points with the pole.
The mounting assembly shall be slotted for 3/4-in. (1.9-cm) banding.
3.0 Construction. The mounting assembly be constructed of 0.1875 in. (0.48 cm) thick or thicker aluminum with 316 stainless steel hardware.
The mounting assembly shall be powder coated for oxidation resistance.
The mounting assembly shall weigh 3 lbs. (1.36 kg).
SmartSensor 6-conductor Cable
WX-500-0074
Part No: SS-704-006
Physical properties
| ˿ Cable diameter: 0.41 in. (1.04 cm) |
| ˿ Jacket: 0.053-in. (1.3-mm) gray PVC |
| ˿ Wire gauges: |
| ̀ Power wires: 20 AWG |
| ̀ Comms wires: 22 AWG |
| ˿ Cable assembly shielded with aluminum/polyester shield |
| ˿ Pull tension: 35 lbs |
| ˿ Connector: |
| ̀ Meets MIL-C-26482 specification |
| ̀ Backshell is environmentally sealed |
| ̀ Backshell offers excellent immersion capability |
| ̀ All conductors that interface with the connector are en- |
cased in a single jacket ̀ Backshell has a strain relief with enough strength to sup-port the cable slack under extreme weather conditions.
Operating conditions ˿ Ambient operating temperature: up to 221°F (105°C) dry / 167°F
(75°C) wet
Connections
| ˿ RS-485 conductors: 2 twisted pairs |
| ˿ Power conductors: twisted pair |
| ˿ One tinned copper drain wire |
Power ˿ Power conductors: twisted pair with nominal conductor DC resistance of less than 11 ohms/1000 ft. (304.8 m) at 20°C
Communication ˿ RS-485 conductor nominal capacitance, conductor to conduc-tor: less than 40 pF/ft. at 1 kHz ˿ RS-485 conductor nominal conductor DC resistance: less than
16.7 ohms/1000 ft. (304.8 m) at 20°C
Testing
| ˿ RoHS compliant |
| ˿ Approvals: UL/cUL Type CMG |
| ˿ Flammability rating: FT4 |
| ˿ UV resistant: Yes (per UL 720 Hour Sunlight Resistance Test) |
| ˿ 600 Volt AWM style 2587 |
Support ˿ Extended support options available; contact a Wavetronix rep-resentative for more information ˿ Comprehensive user guide
Ordering information SmartSensor 6-conductor Cable (set length, connectorized) SS-704 — custom cable length
SS-704-006 (6-ft. cable)
SS-704-020 (20-ft. cable)
SS-704-040 (40-ft. cable)
SS-704-060 (60-ft. cable)
SS-704-080 (80-ft. cable)
SS-704-100 (100-ft. cable)
SmartSensor 6-conductor Cable (bulk spool, non-connectorized) SS-705 — custom cable length (sold in 100-ft.
increments)
101-0448 (500-ft./152.4-m spool)
SS-705-001 (1000-ft./304.8-m spool)
101-0558 (1500-ft./457.2-m spool)
SS-705-002 (5000-ft./1524-m spool)
Contact us 801.734.7200 sales@wavetronix.com www.wavetronix.com
SmartSensor 6-conductor Cable technical specifications
Sensor Cable Junction Box
Junction box for splicing cables The sensor cable junction box provides connection between the sensor’s pigtail cable and the homerun cable to the cabinet. This box’s nine terminal blocks eliminate the need to pull a connectorized cable from the sensor to the cabinet. Its small size allows for an in-line connection that will fit in a hand hole.
˿˿ NEMA type 4, 4x enclosure, providing a degree of protection against falling dirt, windblown dust, water, and ice
˿˿ Insulation displacement terminal blocks for quick wiring
˿˿ Small form factor for placement in traffic pole hand hole
˿˿ Cable grips for water resistance ˿˿ Same-side cable entry prevents cable path water trails from pooling on cable grip
˿˿ Nine terminal blocks means that the box can be used with cables with nine or fewer conductors and drains, namely the Wavetronix
SmartSensor 6-conductor cable and the 8-conductor cable
78 E 1700 S, Provo, UT 84606, US • (801) 734-7200 • www.wavetronix.comWX-500-0160 1 of 3
Physical
˿˿ Dimensions: 6 in. x 3.6 in. x 3.1 in. (15 cm x 9 cm 8 cm) ˿˿ Cable grip cable diameter: 0.2 in.–0.5 in. (5 mm–12.7 mm) ˿˿ Designed to meet IP 66 & NEMA 250 type 1, 3R, 4X, 6P, and
12 ratings ˿˿ Material: fiberglass ˿˿ 316 stainless steel backplate
Connector block ˿˿ 9 terminal blocks ˿˿ Connections: insulation displacement ˿˿ Nominal current IN: 17.5 A ˿˿ Nominal voltage UN: 500 V ˿˿ Maximum load current: 17.5 A ˿˿ Wire: 24–16 AWG
Ordering information Sensor Cable Junction Box
SS-710
Accessories SS-704 – SmartSensor 6-conductor Cable SS-706 – SmartSensor 8-conductor Cable SS-B01-0003/0005/0008 – Intersection Preassem-bled Backplate – AC
Contact us 801.734.7200 sales@wavetronix.com
1.0 General. This item shall govern the purchase of a junction box (JB) equivalent to the Wavetronix SmartSensor cable junction box.
2.0 �Physical. The JB shall not exceed 6.3 in. x 3.6 in. x 2.4 in. (16 cm x 9 cm x 6 cm) in its dimensions.
The JB’s cable grip shall allow for a cable with a diameter of 0.2 in.–0.5 in. (5 mm–12.7 mm).
The JB shall be designed to meet IP 66 & NEMA 250 type 1, 3R, 4X, 6P, and 12 ratings.
The JB shall be made of fiberglass and include a 316 stainless steel backplate.
3.0 Connector block. The JB shall have nine terminal blocks; these blocks’ connections shall employ insulation displacement technology.
The JB shall have a nominal current of 17.5 A and a nominal voltage of 500 V. Its maximum load current shall be 17.5 A. The JB shall accept wire ranging in size from 24–16 AWG.
SmartSensor Surge v2
Surge card allowing for SmartSensor connectivity The SmartSensor Surge card allows you to protect the Arc from surges when using the SmartSensor HD.
Easy to install and remove in the field, the card is secured directly into the back of the Arc. Moreover, it provides a convenient place to terminate the sensor cable while at the same time protecting from surges on that cable. If a surge occurs, don’t replace the whole Arc—just replace the card!
˿ Designed for use with the Arc in an installation with a SmartSensor HD and SmartSensor Matrix
˿ Protects the Arc and other cabinet equipment against surges on the sensor cable
˿ In case of surge, the card can be easily replaced, negating the need to replace the whole Arc or send the Arc in for repairs
˿ Quick and easy installation in the field requires only a slotted screwdriver
˿ Comes with terminal block plug needed to terminate sensor cable into card
˿ Multi-stage surge protection for data and DC power
| ˿ FCC-compliant |
| ˿ Complies with NEMA TS2-2003 |
environmental testing ˿ Surge immunity complies with IEC
61000-4-5 level 4 standard
DR127-150
27CG20 L
DR127-150
27CG20 L
DR127-150
27CG20 L
DR127-150
27CG20 L
SMARTSENSOR
1827 W 650 N, Springville, UT 84663, US • (801) 734-7200 • www.wavetronix.comWX-500-0446 Part No: 102-0562
SmartSensor Surge v2
WX-500-0446
Part No: 102-0562
Physical properties
| ˿ Dimensions: 4.8 in. × 2.7 in. × 1.1 in. (12.1 cm × 6.8 cm × 2.9 cm) |
| ˿ Weight: 0.251 lbs (0.11 kg) |
Operating conditions
| ˿ Ambient operating temperature: -29°F to 165°F (-34°C to 74°C) |
| ˿ Humidity: up to 95% RH |
Connections ˿ Port for pluggable terminal blocks, with included insulation displacement (IDC) terminal block plug
Surge protection ˿ DC power
| ̀ Clamping voltage: 28 VDC |
| ˿ RS-485 |
| ̀ Clamping voltage: 5 VDC |
| ˿ RS-232 |
| ̀ Clamping voltage: 12 VDC |
| ˿ Surge immunity sensor ports: IEC/EN 61000-4-5 level 4 |
Testing ˿ Complies with the applicable standards stated in the NEMA
TS2-2003 standard
| ˿ Shock pulses of 10 g, 11 ms half sine wave |
| ˿ Vibration of 0.5 Grms up to 30 Hz |
| ˿ 300 V positive/negative pulses applied at one pulse per second |
| ˿ Stored at -49ºF (-45ºC) for 24 hours |
| ˿ Stored at 185ºF (85ºC) for 24 hours |
| ˿ Operation at -29.2ºF (-34ºC) |
| ˿ Operation at 165.2ºF (74ºC) |
| ˿ FCC-compliant |
| ˿ Passes manufacturer’s test before shipping |
Support ˿ Extended support options available; contact a Wavetronix rep-resentative for more information ˿ Comprehensive user guide
Warranty ˿ Five-year warranty against material and workmanship defect
Ordering information SmartSensor Surge 102-0562
Contact us 801.734.7200 sales@wavetronix.com www.wavetronix.com
SmartSensor Surge technical specifications
Arc6
6-sensor cabinet interface device Part of the Expanse system, the Arc is all about convenience–providing power, surge protection, and communications for up to six sensors. Multiple Arc6 units can be placed on a single Ethernet network so that, through the Expanse software, you can see and configure all the sensors in your system right from your computer.
˿ Puts all connected Expanse or SmartSensor sensors on your Ethernet network, letting you access them from any connected computer via Expanse software
˿ SDLC port for communicating with compatible controllers
˿ RS-485 and Ethernet connections for onsite configuration and connection to other cabinet devices
˿ Accepts AC power, and passes that power on to up to six sensors
˿ Protects cabinets from surges on the sensor cable
˿ Arc Surge field-replaceable surge cards let you quickly get the device back in top condition after a surge event
˿ Can be set on a shelf or mounted on a cabinet wall or 19-inch rack
W A
N R
S-
LA
N
SD
LC
1827 W 650 N, Springville, UT 84663, US • (801) 734-7200 • www.wavetronix.comWX-500-0417 Part No: 102-0594
WX-500-0417
Part No: 102-0594
Physical properties
| ˿ Weight: 4.9 lbs. (2.2 kg) |
| ˿ Dimensions: 8.72 in. × 3.42 in. × 10.71 in. (22.14 cm × 8.6 cm × |
27.2 cm) ˿ Included components
| ̀ AC power cable |
| ̀ Ethernet cable |
| ̀ Three blank field replaceable surge card covers |
Operating conditions
| ˿ Ambient operating temperature: -29°F to 165°F (-34°C to 74°C) |
| ˿ Humidity: up to 95% RH |
Mounting
| ˿ Shelf-mount |
| ˿ Mounting brackets available for purchase |
| ̀ 19-in. rack mount bracket (2U height) |
| ̀ Side-mount strut channel bracket |
| ̀ Top/bottom-mount bracket |
Connections ˿ Power and surge
| ̀ AC input: IEC AC input |
| ̀ Power switch on back of device turns off power to device |
| ̀ Arc Surge field-replaceable surge cards protect the device |
from surges coming in on the sensor cable ˿ Ethernet
̀ 2 RJ-45 10/100 jacks on the front of the device for wired Ethernet communications to other Wavetronix devices, or for onsite configuration
̀ 1 RJ-45 10/100 jack on the front of the device for wired Ethernet communications to customer network
| ˿ SDLC |
| ̀ 1 SDLC port on the front of the device for connecting to |
SDLC-compatible controllers ˿ Serial
̀ 2 RJ-11 jacks on the front of the device for RS-485 com-munications
| ˿ Connections to sensor |
| ̀ Six slots on back of device for plugging in field-replace- |
able surge cards ̀ Field-replaceable surge cards provide a spot for termina-tion of sensor cables, as well as protecting the device from surges on that cable
Power
| ˿ AC power supply voltage: 120 VAC |
| ˿ AC frequency: 50–60 Hz |
| ˿ Max AC current: 6 A |
| ˿ Supports 6 sensors (up to 25 W each) |
Configuration ˿ Illuminated indicators show when data is being transmitted and received on the Ethernet, serial, SDLC and sensor ports
| ˿ ±5ppm real-time clock with super capacitor backup |
| ˿ Supports time synchronization from GPS, NTP, or real-time |
clock
Surge protection
| ˿ AC input surge immunity: IEC/EN 61000-4-5 level 3 |
| ˿ Sensor ports surge immunity: IEC/EN 61000-4-5 level 4; must |
be obtained by purchasing an FRS card (102-0480)
Testing ˿ Tested under FCC CFR 47, Part 15, Subpart B & ICES-003, Issue
6 + A1
| ˿ FCC certification on product label |
| ˿ FCC regulation–compliant for life of the sensor |
| ˿ Complies with the applicable standards stated in the NEMA |
Ordering information Arc6 102-0594
Optional accessories (sold separately) 102-0564 – Arc Surge v2 102-0562 – SmartSensor Surge v2 102-0537 – Arc Surge Expanse Link Spring Cage Connector Kit 102-0481 – Blank Cover for Arc Surge 102-0486 – Arc 19-inch Rack Bracket 102-0485 – Arc NEMA Side-mount Bracket 102-0487 – Arc Diamond Bracket 101-0463 – Expanse Link S Cable 5000’ spool 101-0464 – Expanse Link S Cable 1000’ spool 101-0465 – Expanse Link S Cable 500’ spool
Contact us 801.734.7200 sales@wavetronix.com www.wavetronix.com
Arc6 technical specifications
WX-500-0417
Part No: 102-0594
TS 2-2021 Standard
| ˿ Passes manufacturer’s test before shipping |
| ˿ Equipment labeling found on the bottom of the unit |
Support ˿ Extended support options available; contact a Wavetronix rep-resentative for more inoformation ˿ Comprehensive user guide
Warranty ˿ Five-year warranty against material and workmanship defect
SDLC Straight Cable
4-ft. male-to-male SDLC cable The SDLC straight cable can be used to add traffic devices to an SDLC bus in a NEMA TS-2 cabinet.
It can also be used in conjunction with the SDLC Hub, also available from Wavetronix, to increase the number of interconnected SDLC devices.
| ˿ Four feet in length |
| ˿ Two male connectors (15 pin) |
with clips for connecting to SDLC devices
˿ Cable rated to 300V RMS
Cable length 4 ft.
Male connector
Male connector
Any SDLC device Any SDLC device
663 Wavetronix Drive, Springville, UT 84663, US • (801) 734-7200 • www.wavetronix.comWX-500-0365 Part No: 310-0419
Wavetronix Page 1 of 2
SDLC Straight Cable
WX-500-0365
Part No: 310-0419
Physical properties
| ˿ Cable length: 4 ft. (1.2 m) |
| ˿ PVC jacket and insulation |
| ˿ Two male SDLC connectors (15 pin) |
| ˿ Connectors include clips |
Operating conditions ˿ Ambient operating temperature: -35°C to 105°C
Connections ˿ 5 twisted pairs 24 AWG stranded tinned copper conductors
Power ˿ Maximum operating voltage: 300V RMS
Support ˿ Extended support options available; contact a Wavetronix rep-resentative for more information
Ordering information SDLC Straight Cable 310-0419
Contact us 801.734.7200 sales@wavetronix.com www.wavetronix.com
SDLC Straight Cable technical specifications
Wavetronix Page 2 of 2
SDLC 4-port Hub
Hub for terminating SDLC cables The SDLC 4-port Hub provides a quick, easy way to connect multiple SDLC devices to one controller in a NEMA TS-2 cabinet. This hub can also be used in conjunction with the Wavetronix SDLC Y cable to allow one additional SDLC device.
˿ Four female SDLC ports (15 pin) allow for the connection of up to four devices
˿ Simplifies wiring within a cabinet;
simply connect your SDLC de-vices into the hub
˿ Four flanges…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .